• Title/Summary/Keyword: Semi-floor

Search Result 99, Processing Time 0.026 seconds

A Study on Crack Reduction Method in open Section of Down-Up Underground Construction Method Affected by Earth Pressure (토압 영향을 받는 Down-Up 지하공사 공법의 오픈 구간 균열 저감 방안 연구)

  • Shim, Hak-Bo;Jeon, Hyun-Soo;Seok, Won-Kyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.196-197
    • /
    • 2021
  • The underground method can be divided into Top-Down, Semi-Top-Down, Up-Up and Down-Up methods according to the construction order of the upper and lower structures. Among them, the Down-Up method proceeds with the construction of the first floor and its lower floors, and when the foundation is completed, the vertical members of the basement are sequentially completed from the foundation and the above-ground floor is constructed. In this paper, the crack reduction method around the open section of the Down-Up method affected by earth pressure was analyzed and divided into design and construction parts.

  • PDF

Efficient Analysis of Shear Wall Strustures with Pilotis considering the in-plane stiffness of the floor slabs (바닥슬래브의 면내강성을 고려한 필로티 구조물의 효율적인 거동분석)

  • Kim Hyun-Su;Kim Hye-Sook;Kim Hyun-Jung;Lee Dong-Guen
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.865-872
    • /
    • 2006
  • Recently, many apartment buildings in the shear wall system often has pilotis in the lower story to meet the architectural needs. If the lateral force resisting system consists of shear walls supported by columns and beams. the discontinuity at the lowest level with pilotis results in the vertical irregularity with strength and stiffness. So, there are needs to be considered tile analysis and design about column and beam bellow shear walls and the behavior and stress condition of structure by stiffness change being generated at shear walls. The purpose of this paper is to investigate the behavior of shear wall structures with pilotis using the floors modeled as rigid diaphragm or semi rigid diaphragm. Through analyses, after estimating values of the story drift, natural period, stress condition of shear walls and the forces of column, we inferred how the behavior of shear wall structures with pilotis was influenced by the floor stiffness.

  • PDF

The Architectural Structure of Seonjeong-jeon in Changdeok Palace as a Ceremonial Hall (창덕궁 선정전의 의례 공간적 건축 구조)

  • Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.29 no.2
    • /
    • pp.39-52
    • /
    • 2020
  • Seonjeong-jeon, the semi-great hall in Changdeok Palace, was constructed in a highly formal and conservative style and accommodated official ceremonies. However, the contemporary modification of the building has distorted or eliminated features including the two side doors on the front, the floor coverings, and the throne base (Jwa-tap) that consisted the most significant part of the throne. Seonjeong-jeon originally had three doors that stood between each pair of columns on the front side, respectively. The courtiers accessed the building through the side doors, while the central door was exclusively designated for the king. However, the renovation in 1999 ignored the political context of the architectural form of the building and changed the side doors into windows, damaging the traditional structure inherited from the early Joseon Dynasty. Although the building currently has traditional wooden floor structure (Woomul-maru), it was originally covered with square brick tiles (Bang-jeon) before the Japanese occupation, following the customs of early Joseon Dynasty. The throne was placed to the north of the central door and consisted of the throne base and a decorative roof (Dang-ga). A canvas (Jang-ja), which featured the royal symbolic painting of Sun, Moon, and Five Peaks, was also installed between the two columns that connected the base and the roof. Nevertheless, only the columns and the blank canvas remain nowadays after the removal of the base.

The Tentative Plans of Middle-rise Traditional Houses (Han-ok) Located on Seoun-dong in Urban Area of Cheongju, Korea (중층형 생활한옥 모델시안 연구 - 청주 서운동의 사례를 중심으로 -)

  • Kim, Chan Gu;Kim, Tai Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.2
    • /
    • pp.21-28
    • /
    • 2022
  • Focusing on the creation of a new han ok, especially a mid-rise hybrid-structured Han-ok, this study proposes a middle-rise (four-story) Han-ok on one and two lots located in Seoun-dong, the existing Han-ok intensive housing site in downtown Cheongju. 1) In terms of layout and function, according to the existing L-shaped Han-ok corresponding to the road and the direction, the parking lots and shops on the 1st floor, the business facility on the 2nd floor, the Han-ok on the 3rd and 4th floors are placed. There are yards, open roof yards, and semi-open Daecheong(大廳, main hall), which can be shared by residents. 2) In terms of structure and form, one or two floors (some 3 floors) are 5.4m square and 5.4×6.6m modules of the RC(Reinforced Concrete) group, and the upper floor reflects the 2.7m module, size and shape of the existing Han-ok. By extending the outer wall of the RC group in the lower floors (1st to 3rd floors) to the wooden exterior of the upper floors (2nd to 4th floors), it is attempted to avoid the awkward appearance of the RC group being exposed to wooden structures. And it is also attempted to reflect the wooden shape and design elements through the elevation elements such as horizontal windows, corner windows, picture frames, and vertical slits. 3) In environmental control and facilities, it is attempted to smooth the ventilation of the building by forming a vertical upward airflow from the dark space of the low floor to the positive of the upper floor. This doubles the effect through a vertical rise of cold air generated in a narrow alleyway, piloti parking lot, and the various voids. In addition to the Daecheong and Numaru(loft) of Han ok, the rooftop yard, the terrace, and the balcony, horizontal natural ventilation is generated through divided doors and transom windows.

Semi-active damped outriggers for seismic protection of high-rise buildings

  • Chang, Chia-Ming;Wang, Zhihao;Spencer, Billie F. Jr.;Chen, Zhengqing
    • Smart Structures and Systems
    • /
    • v.11 no.5
    • /
    • pp.435-451
    • /
    • 2013
  • High-rise buildings are a common feature of urban cities around the world. These flexible structures frequently exhibit large vibration due to strong winds and earthquakes. Structural control has been employed as an effective means to mitigate excessive responses; however, structural control mechanisms that can be used in tall buildings are limited primarily to mass and liquid dampers. An attractive alternative can be found in outrigger damping systems, where the bending deformation of the building is transformed into shear deformation across dampers placed between the outrigger and the perimeter columns. The outrigger system provides additional damping that can reduce structural responses, such as the floor displacements and accelerations. This paper investigates the potential of using smart dampers, specifically magnetorheological (MR) fluid dampers, in the outrigger system. First, a high-rise building is modeled to portray the St. Francis Shangri-La Place in Philippines. The optimal performance of the outrigger damping system for mitigation of seismic responses in terms of damper size and location also is subsequently evaluated. The efficacy of the semi-active damped outrigger system is finally verified through numerical simulation.

Controlling the lateral displacement of building with external lever by using of MR damper

  • Takin, Kambiz;Hashemi, Behrokh Hosseini;Nekooei, Masoud
    • Earthquakes and Structures
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • This article is all about using the MR damper with an external lever system for mitigation torsional and transitional lateral displacements by using of PID control algorithm. The torsional modes are so destructive and can be varied during an earthquake therefore, using a semi-active control system mostly recommended for them. In this paper the corner lateral displacement of each floor obtains and then it equivalents in a solid member and it connects to an MR damper, which relies to a rigid structure to reduce the response. An MR damper is a semi-active control system, which can absorb a lot of energy by injecting current to it. This amount of current is very low and needs low power supply, but it increases the amount of damper force, rather than inactive systems like viscous dampers. This paper will show the appropriate algorithm for current injection into MR damper when the eccentricity of the load is changed by using of Bouc-Wen and Bingham's methods and illustrates the coincidence of them.

Issues in offshore platform research - Part 1: Semi-submersibles

  • Sharma, R.;Kim, Tae-Wan;Sha, O.P.;Misra, S.C.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.2 no.3
    • /
    • pp.155-170
    • /
    • 2010
  • Availability of economic and efficient energy resources is crucial to a nation's development. Because of their low cost and advancement in drilling and exploration technologies, oil and gas based energy systems are the most widely used energy source throughout the world. The inexpensive oil and gas based energy systems are used for everything, i.e., from transportation of goods and people to the harvesting of crops for food. As the energy demand continues to rise, there is strong need for inexpensive energy solutions. An offshore platform is a large structure that is used to house workers and machinery needed to drill wells in the ocean bed, extract oil and/or natural gas, process the produced fluids, and ship or pipe them to shore. Depending on the circumstances, the offshore platform can be fixed (to the ocean floor) or can consist of an artificial island or can float. Semi-submersibles are used for various purposes in offshore and marine engineering, e.g. crane vessels, drilling vessels, tourist vessels, production platforms and accommodation facilities, etc. The challenges of deepwater drilling have further motivated the researchers to design optimum choices for semi-submersibles for a chosen operating depth. In our series of eight papers, we discuss the design and production aspects of all the types of offshore platforms. In the present part I, we present an introduction and critical analysis of semi-submersibles.

Characteristics of Factory Architecture in Semi-industrial Area of Seong-su - A Case Study Factory Building Permits in 2010s - (성수동 준공업지역 공장건축물의 건축행위 특성에 관한 연구 - 2010년대 건축행위 허가 및 신고 사례를 중심으로 -)

  • Yang, Yoo-sang;Park, So-Hyun
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.12
    • /
    • pp.145-156
    • /
    • 2018
  • This study explores changes of industrial scales and building activities in the semi-industrial area of Seoul's Seong-su, responding to the shifts of industrial structures and policies in the Korean society. The purpose of this study is to investigate patterns of construction activities of factory buildings in the Seong-su semi-industrial area by analyzing changes in industrial facilities. As a result of the analysis, the change of the factory building area come out from the recent survey implies the possibility of entrepreneurial inflow as much and the new constructions and some remodeling cases which are characterized by complexity seem to correspond to the industrial structure. However, it is unreasonable to believe that this phenomenon is a mainstream movement involving small-scale factory buildings and companies. This is because there are aspects that are not included in this movement, such as changing the use of buildings without accompanying physical changes. On the other hand, compared to various movements of individual companies in response to the industrial structure, the physical plan suggests a limited alternative centering on the floor area ratio and the building area ratio. This means that the efforts to attract and grow the power of knowledge based-industry through the designation of the Industrial Development Promotion District in part of the case sites, overlook the natural change through remodeling and reuse of existing buildings. In addition, considering the fact that the production space of industrial use can be greatly influenced by the behavior of users compared to general buildings such as residential and commercial, it is necessary to pay attention to various phenomena occurring in the area more locally than the uniform supply policy. Based on these findings, this study contributes to illuminate the legal system related to building act in the Seong-su semi-industrial area and the potential direction of architectural suggestions in related policies and researches.

Effect of Semi-Dry Anaerobic Digestion Using Dairy Cattle Manure and Pig Slurry (젖소 분과 돈분 슬러리를 이용한 반 건식 혐기소화 효과)

  • Jeong, Kwang-Hwa;Kim, Jung-Kon;Lee, Dong-jun;Lee, Dong-Hyun;Jeon, Jung-Hwan
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.2
    • /
    • pp.85-93
    • /
    • 2018
  • Semi-dry anaerobic digestion experiment using dairy cattle manure collected from dairy cattle house was conducted to analyze efficiency of biogas production. As a first experiment, Biochemical Methane Potential (BMP) test was carried out according to certain ratio of sample mixtures: dairy cattle manure, pig slurry, and mixture of dairy cattle manure and pig slurry. The amount of methane accumulated during BMP test period was high in the experimental groups containing dairy cattle manure. As a second experiment, semi-dry anaerobic digestion experiment was carried out using only the dairy cattle manure collected from floor of the dairy cattle house. Judging from the experimental results, the optimum hydraulic retention time (HRT) of semi-dry anaerobic digestion for dairy cattle manure containing 13% of TS was 25 days. The amount biogas generated from the semi-dry anaerobic digestor with the TS of 13% of the dairy cattle manure ranged from 1.36~1.50v/v-d and the average was 1.44v/v-d. The optimum HRT of the semi-dry anaerobic digestor for dairy cattle manure containing TS of 15% and the semi-dry anaerobic digestor for dairy cattle manure containing TS of 17% was the same as 30 days. The amount biogas generated from the semi-dry anaerobic digestor with the TS of 15% of the dairy cattle manure ranged from 1.42~1.52v/v-d and the average was 1.47v/v-d. The amount biogas generated from the semi-dry anaerobic digestor with the TS of 17% of the dairy cattle manure ranged from 1.50~1.61v/v-d and the average was 1.55v/v-d.