• Title/Summary/Keyword: Semi-Adjustable Articulator

Search Result 13, Processing Time 0.025 seconds

A study on the difference of movement between Semi adjustable articulator and Oral in vivo (반조절성교합기와 구강에서의 운동 오차에 대한 비교 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.53-59
    • /
    • 2006
  • The movement range on the semi adjustable articulator and the movement range in an oral were measured. And then I studied to analyze the gap. I got wax records by the movement on the semi adjustable articulator, the movement in an oral. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the semi adjustable articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the semi adjustable articulator although it did not finish in an oral. When the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the semi adjustable articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are appeared to be straight. Therefore dental prosthesisses were made by the semi adjustable articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the semi adjustable articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the semi adjustable articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The difference in the range of movement is considered as the gap that is made because the movement only can be occurred as straight in the semi adjustable articulator. 3. When the dental technician understand mandibular movement and articulator deficiencies, they can attain proficiency in use of the articulator and reduce the gap.

  • PDF

A STUDY ON THE DIFFERENCE OF THE SAGITTAL CONDYLAR GUIDANCE BY SEMI-ADJUSTABLE ARTICULATOR AND AXIOGRAPH (반조절성교합기와 Axiograph를 이용한 전방시상과로각 차이에 관한 연구)

  • Park, Geon-Ho;Lee, Sung-Bok;Bak, Jin;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.696-705
    • /
    • 2007
  • Statement of problem: In the Protar articulator, the models are almost parallel with the Camper's plane. The ultrasonic-based ARCUSdigma system is basis for the determination of dynamic function parameters with so-called "articulator related registration". Purpose: The purpose of this study was to compare the sagittal condylar guidance angles found by use of the wax protrusive records in a semi-adjustable articulator(KaVo Protar 7) with those found by use of the Axiograph (ARCUSdigma). 83 volunteers with intact dentition participated in this study after obtainment of informed consent. Material and method: The sagittal condylar guidance angles were measured and estimated statistically by semi-articulator and Axiograph. All the readings were in degrees. No control was used in this project. To test whether there was a significant difference between the 2 independent samples, paired t-test and Kruskal-Wallis test were carried out(p=.05). Results: 1. The mean results for the wax protrusive records were as follow: right side (32.65 degrees, SD 16.48); left side (33.27 degrees, SD 17.49). 2. The mean results for the Axiograph were as follow: right side (32.26 degrees, SD 7.00); left side (33.07 degrees, SD 7.58). 3. There was no statistical difference on the wax protrusive records and Axiograph(p>0.05). Conclusion: Both methods of wax protrusive records and Axiograph are clinically acceptable for measuring the sagittal condylar guidance angles in semi-adjustable articulators.

A comparative study to measure the condylar guidance by the radiographic and clinical methods

  • Shreshta, Pragya;Jain, Veena;Bhalla, Ashu;Pruthi, Gunjan
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.153-157
    • /
    • 2012
  • PURPOSE. The study was conducted to compare the radiographic and clinical methods of measuring the horizontal condylar guidance (HCG) values. MATERIALS AND METHODS. The condylar guidance was measured using the radiographic (CT scan) and three clinical methods i.e. the wax protrusive records, Lucia jig record and intraoral central bearing device in 12 patients aged between 20-40 years irrespective of sex. The records were taken and transferred on the semi-adjustable articulator to record the HCG values. The CT scan was taken for 3D reconstruction of the mid facial region. Frankfort horizontal plane (FHP) and a line extending from the superior anterior most point on the glenoid fossa to the most convex point on the apex of articular eminence (AE) was marked on the CT scan. An angle between these two lines was measured on both right and left sides to obtain condylar inclination angle. Three interocclusal protrusive wax and jig records were taken and transferred to the semi adjustable articulator. Three readings were recorded on each side. Similarly the records were taken and transferred to the same articulator using the intra oral central bearing device to record the readings. RESULTS. The statistical analysis showed insignificant differences in the HCG values between the right and left sides [(P=.589 (CT), P=.928 (wax), P=.625 (jig), P=.886 (tracer)]. The clinical methods provided low Pearsons correlation values [(R = 0.423 (wax), R = 0.354 (jig), R = 0.265 (tracer)] for the right as well as the left sides when compared with the CT values. Among the clinical methods, jig and wax method showed strong level of association which is statistically significant while the intra-oral tracer showed weak association with the other two methods. CONCLUSION. The right and left HCG values were almost similar. The CT scan showed higher HCG values than the clinical methods and among the clinical methods, values obtained from all the methods were comparable.

A comparative study to measure the sagittal condylar inclination using mechanical articulator, virtual articulator and jaw tracking device

  • Liya Ma;Fei Liu;Jiansong Mei;Jiarui Chao;Zhenyu Wang;Jiefei Shen
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.1
    • /
    • pp.11-21
    • /
    • 2023
  • PURPOSE. To compare the sagittal condylar inclination (SCI) in dentate individuals measured by the different methods with mechanical articulator (MA), virtual articulator (VA), and a jaw tracking device (JTD) system. MATERIALS AND METHODS. A total of 22 healthy dentate participants were enrolled in this study. For MA workflow, the SCI was obtained by a semi-adjustable articulator with protrusive interocclusal records. The SCI was also set on a VA by aligning intraoral scan (IOS) with cone beam computed tomography (CBCT) and facial scan (FS), respectively. These virtual workflows were conducted in a dental design software, namely VAIOS-CBCT and VAIOS-FS. Meanwhile, a JTD system was also utilized to perform the measurement. Intraclass correlation was used to assess the repeatability within workflows. The bilateral SCI values were compared by Wilcoxon matched-pairs signed rank test for each workflow, and Kruskal-Wallis test and post hoc p-value Bonferroni correction were used to compare the differences among four workflows. The agreement of VAIOS-CBCT, VAIOS-FS, and JTD compared with MA was evaluated by Bland-Altman analysis. RESULTS. Intraclass correlation of the SCI revealed a high degree of repeatability for each workflow. There were no significant differences between the left and right sides (P > .05), except for VAIOS-CBCT (P = .028). Significant differences were not found between MA and VAIOS-FS (P > .05). Bland-Altman plots indicated VAIOS-CBCT, VAIOS-FS, and JTD were considered to substitute MA with high 95% limits of agreement. CONCLUSION. The workflow of VAIOS-FS provided an alternative approach to measure the SCI compared with MA.

Occlusal rehabilitation of posterior fixed prostheses: A clinical report

  • Yeo In-Sung;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.313-318
    • /
    • 2001
  • Masticatory function is more important than esthetics in posterior fixed restoration. The usual technique-mounting the casts on a semi-adjustable articulator, etc. -cannot make all patients satisfied with their restorations. For example, functionally generated path technique can be an easier and more satisfactory method in the restoration of group function. These clinical reports describe various approaches for occlusal restoration of relatively simple posterior fixed protheses according to patients occlusal patterns. The 3-unit bridge restoration is one of the most popular treatment options in prosthodontics. Because dentists have much experiences of it, they restore a missing span of one tooth mechanically, that is, without special consideration. While esthetics is important in making an anterior 3-unit fixed prostheses, mastication is more focused on in posterior 3-unit bridge restoration. Many dentists are concerned about various aspects in esthetics, such as morphology of the tooth, value, chroma, hue, translucency, surface texture, etc. But they do not usually consider various methods to restore occlusion. They treat one-tooth-missing area in a similar way in spite of patients having variety of occlusal patterns. Three cases are presented here in 3 or 4-unit bridge restoration. They show some methods to restore patients' occlusal patterns.

  • PDF

DETERMINATION OF ESTHETIC REFERENCE PLANE FOR SEMI-ADJUSTABLE ARTICULATORS (반조절성 교합기의 심미적 기준 평면에 관한 연구)

  • Hwang, Hie-Seong;Jeon, Young-Chan;Jung, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.448-456
    • /
    • 1996
  • The purpose of this study is to evaluate suitable anterior reference point similar to esthetic reference plane of the patient while transferring the suitable facebow. So those who live in Pusan with the normal occlusal relationship were chosen as subjects. The esthetic reference planes determined by the participants themselves and the superior reference line (anterior reference point) in Hanau & Denar articulator were compared with F-H plane in the standard lateral cephalogram. The results were as follows. 1. The angle between the esthetic reference plane and F-H plane was $2.81{\pm}5.7^{\circ}$. 2. The reference line, 43mm from Beyron point to the edge of the upper incisor, was the reference plane that had the closest paralleled relationship with the esthetic reference plane. 3. Transferring with ear piece type face-bow, the anterior reference point that showed the esthetic reference plane was 17mm below orbitale or 43mm above, the edge of the upper incisor.

  • PDF

Positional deviation between CBCT-based digital facebow transfer and analog facebow transfer: case series (CBCT 기반 디지털 안궁이전과 아날로그 안궁이전의 위치 편차: 증례보고)

  • Myung Hyun Park;Keunbada Son;Hwi-Gyun Ahn;Du-Hyeong Lee;So-Yeun Kim;Kyu-Bok Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.176-185
    • /
    • 2023
  • Facebow transfer is essential for accurately mounting a dental cast onto a semi-adjustable articulator. The precision of traditional analog facebow transfer is influenced by both the accuracy of the equipment used and the skill level of the operator. Considering that substantial positional deviations can adversely affect the quality of a fabricated dental prosthesis; it is critical to assess the positional accuracy of casts mounted using analog facebow transfer. This case report evaluates the linear and angular deviations of the occlusal plane for maxillary casts mounted through both analog facebow transfer and cone-beam computed tomography-based methods. The findings indicate that analog facebow transfer produced a linear deviation ranging from 3 to 16 mm and an angular deviation of the occlusal plane between 5 to 7 degrees. This case report confirms that, across two patients, analog facebow transfer can result in varying degrees of positional deviation, thereby potentially leading to inaccuracies in the fabrication of dental prostheses. These results suggest that, in clinical practice, the use of analog facebow transfer may yield significant deviations during the process of mounting maxillary casts.

Comparison of condylar displacement between three biotypological facial groups by using mounted models and a mandibular position indicator

  • Ponces, Maria Joao;Tavares, Jose Pedro;Lopes, Jorge Dias;Ferreira, Afonso Pinhao
    • The korean journal of orthodontics
    • /
    • v.44 no.6
    • /
    • pp.312-319
    • /
    • 2014
  • Objective: Facial-type-associated variations in diagnostic features have several implications in orthodontics. For example, in hyperdivergent craniofacial types, growth imbalances are compensated by displacement of the condyle. When diagnosis and treatment planning involves centric relation (CR), detailed knowledge of the condylar position is desirable. The present study aimed to measure condylar displacement (CD) between CR and maximum intercuspation in three facial types of an asymptomatic orthodontic population. Methods: The study was conducted in 108 patients classified into three groups of 36 individuals each (27 women and 9 men; mean age, 20.5 years), based on the following facial patterns: hyperdivergent, hypodivergent, and intermediate. To quantify CD along the horizontal and vertical axes, the condylar position was analyzed using mounted casts on a semi-adjustable articulator and a mandibular position indicator. The Student t-test was used to compare CD between the groups. Results: Vertical displacement was found to be significantly different between the hyperdivergent and hypodivergent groups (p < 0.0002) and between the hyperdivergent and intermediate groups (p < 0.0006). The differences in horizontal displacement were not significant between the groups. In each group, vertical CD was more evident than horizontal displacement was. Conclusions: All facial types, especially the hyperdivergent type, carried a significantly high risk of CD. Therefore, the possibility of CD should be carefully evaluated and considered in the assessment of all orthodontic cases in order to accurately assess jaw relationships and avoid possible misdiagnosis.

Full mouth rehabilitation of a patient with occlusal plane discrepancy with milling machine for clinic (진료실용 밀링머신을 이용한 교합평면 부조화 환자의 완전 구강 회복술)

  • Park, Ji-Man
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.2
    • /
    • pp.68-78
    • /
    • 2016
  • Recently, digital technology has become increasingly prevalent in the dental clinic. Using a milling machine for clinic, it is possible to produce provisional restoration inside the clinic. This can promote large clinical cases such as full mouth rehabilitation with the help of a tabletop scanner, which is capable of semi-adjustable articulator equipment, and a powerful dental CAD software with excellent user convenience. In this case report, a full-mouth rehabilitation was done with digital technology to a 55 year-old female patient, who has lost vertical dimension through the attrition, and has got inclined occlusal plane with unplanned and repeated dental reconstruction. Through the design and milling of the provisional restoration in the clinic and the duplication of these provisionals by double scanning technique, a good functional and esthetic result could be achieved.