• Title/Summary/Keyword: Self-ligating brackets

Search Result 16, Processing Time 0.021 seconds

A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type

  • Lee, Souk Min;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.45 no.1
    • /
    • pp.13-19
    • /
    • 2015
  • Objective: This study aimed to compare the frictional force (FR) in self-ligating brackets among different bracket-archwire angles, bracket materials, and archwire types. Methods: Passive and active metal self-ligating brackets and active ceramic self-ligating brackets were included as experimental groups, while conventional twin metal brackets served as a control group. All brackets were maxillary premolar brackets with 0.022 inch [in] slots and a $-7^{\circ}$ torque. The orthodontic wires used included 0.018 round and $0.019{\times}0.025$ in rectangular stainless steel wires. The FR was measured at $0^{\circ}$, $5^{\circ}$, and $10^{\circ}$ angulations as the wire was drawn through the bracket slots after attaching brackets from each group to the universal testing machine. Static and kinetic FRs were also measured. Results: The passive self-ligating brackets generated a lower FR than all the other brackets. Static and kinetic FRs generally increased with an increase in the bracket-archwire angulation, and the rectangular wire caused significantly higher static and kinetic FRs than the round wire (p < 0.001). The metal passive self-ligating brackets exhibited the lowest static FR at the $0^{\circ}$ angulation and a lower increase in static and kinetic FRs with an increase in bracket-archwire angulation than the other brackets, while the conventional twin brackets showed a greater increase than all three experimental brackets. Conclusions: The passive self-ligating brackets showed the lowest FR in this study. Self-ligating brackets can generate varying FRs in vitro according to the wire size, surface characteristics, and bracket-archwire angulation.

ORIGINAL ARTICLE - Adhesion of Streptococcus mutans and Streptococcus sobrinus to different types of self-ligating brackets

  • Yang, Pil-Seung;Yu, Yoon-Jeong;Cha, Jung-Yul;Hwang, Chung-Ju
    • The Journal of the Korean dental association
    • /
    • v.50 no.7
    • /
    • pp.394-406
    • /
    • 2012
  • Objective: The adhesion capabilities of different types of self-ligating brackets were measured with respect to Streptococcus mutans and Streptococcus sobrinus. Methods: Five types of self-ligating brackets (Clippy-C; Mini Clippy; Clarity-SL; Speed; Damon 3) were used for the experiment group and composite resin brackets (Spirit-MB), metal brackets (Victory) and polycrystalline alumina brackets (Clarity) were used for the control group. In order to assess adhesion of bacteria to the brackets, the brackets were cultured for 3, 6 and 24 hours in media containing bacteria and 20% sucrose. Results: There was no statistic difference in adhesion amount of Streptococcus mutans and Streptococcus sobrinus according to the types of brackets. A total adhesion amount according to bracket type was different. An extended incubation time increased adhesion amount. Observation under scanning electron microscope showed that Streptococcus sobrinus adhered more to Clippy-C and Victory rather than to Clarity-SL. Conclusions: Clarity-SL, a self-ligating esthetic bracket was confirmed to show lower bacterial adhesion to cariogenic bacteria, Streptococcus mutans and Streptococcus sobrinus group than other self-ligating brackets or conventional brackets, which suggests that proper use of self-ligating esthetic brackets might even be better in preventing tooth surface decalcification.

Clinical considerations with self-ligating brackets (자가결찰브라켓을 이용한 교정 치료의 임상적 고려사항)

  • Kim, Hoon;Kim, Kwang-Yoo;Kang, Yoon-Goo;Kim, Seong-Hun;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.474-482
    • /
    • 2006
  • Self-ligating brackets have a permanently installed movable component to entrap the archwire which reduces much of the friction created by conventional ligation. Therefore, it allows for rapid tooth movement and shorter overall treatment time. Due to these advantages, interest in self-ligating brackets is increasing. In this report, several practical considerations for using self-ligating brackets are given to appreciate and maximize their benefits. It is thought that self-ligating brackets make shorter and more efficient treatment possible.

Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study

  • Chen, Huizhong;Han, Bing;Xu, Tianmin
    • The korean journal of orthodontics
    • /
    • v.49 no.1
    • /
    • pp.21-31
    • /
    • 2019
  • Objective: This study was performed to explore the effect of different bracket, archwire, and ligature combinations on resistance to sliding (RS) and rotational control in first-order angulation. Methods: Three types of brackets (multi-level low friction [MLF], self-ligating, and conventional brackets) coupled with four nickel-titanium archwires (0.012, 0.014, 0.016, and 0.018-inch diameter) and two stainless steel ligatures (0.20 and 0.25 mm) were tested in different first-order angulations ($0^{\circ}$, $2^{\circ}$, $4^{\circ}$, $6^{\circ}$, $8^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$) by using an Instron universal mechanical machine in the dry state at room temperature. RS value was evaluated and compared by one-way ANOVA. Results: Under the same angulation, the RS values showed the following order: conventional brackets > MLF brackets > self-ligating brackets. The RS was the highest for conventional brackets and showed a tendency to increase. The RS for MLF brackets coupled with thinner archwires and ligatures showed a similar tendency as the RS for the self-ligating bracket. In contrast, the RS for MLF brackets coupled with thicker archwires and ligatures increased like that for conventional brackets. MLF brackets showed the greatest range of critical contact angles in first-order angulation. Conclusions: The RS in first-order angulation is influenced by bracket design, archwire, and ligature dimension. In comparison with self-ligating and conventional brackets, MLF brackets could express low friction and rotational control with their greater range of critical contact angles.

Surface analysis of metal clips of ceramic self-ligating brackets

  • Kim, Kyung Sook;Han, Se Jik;Lee, Tae-Hee;Park, Tae-Joon;Choi, Samjin;Kang, Yoon-Goo;Park, Ki-Ho
    • The korean journal of orthodontics
    • /
    • v.49 no.1
    • /
    • pp.12-20
    • /
    • 2019
  • Objective: The aim of this study was to analyze the surface composition, roughness, and relative friction of metal clips from various ceramic self-ligating brackets. Methods: Six kinds of brackets were examined. The control group (mC) consisted of interactive metal self-ligating brackets while the experimental group (CC, EC, MA, QK, and WA) consisted of interactive ceramic self-ligating brackets. Atomic force microscopy-lateral force microscopy and scanning electron microscopy-energy-dispersive X-ray spectroscopy were used to analyze the surface of each bracket clip. Results: All the clips in the experimental groups were coated with rhodium except for the QK clip. The results showed that the QK clip had the lowest average roughness on the outer surface, followed by the MA, EC, WA, and CC clips. However, the CC clip had the lowest average roughness on the inner surface, followed by the QK, WA, MA, and EC clips. The QK clip also had the lowest relative friction on the outer surface, followed by the MA, EC, CC, and WA clips. Likewise, the CC clip had the lowest relative friction on the inner surface, followed by the QK, WA, MA, and EC clips. Conclusions: The surface roughness and relative friction of the rhodium-coated clips were generally higher than those of the uncoated clips.

Mandibular changes during initial alignment with SmartClip self-ligating and conventional brackets: A single-center prospective randomized controlled clinical trial

  • Celikoglu, Mevlut;Bayram, Mehmet;Nur, Metin;Kilkis, Dogan
    • The korean journal of orthodontics
    • /
    • v.45 no.2
    • /
    • pp.89-94
    • /
    • 2015
  • Objective: To test the null hypothesis that SmartClip self-ligating brackets are more effective than conventional brackets for initial mandibular alignment and identify influential factors. Methods: Fifty patients were randomly allocated to two equal treatment groups by using an online randomization program: self-ligating group (SmartClip brackets) and conventional group (Gemini brackets). The archwire sequence was standardized. Changes in anterior irregularity index, intercanine width, and intermolar width were assessed on plaster models at 8th and 16th weeks. Changes in incisor position and inclination were assessed on lateral cephalometric radiographs at 16 weeks. Intragroup and intergroup comparisons were performed with paired t-test and Student's t-test, respectively. Multiple linear regression was performed to identify variables affecting improvement in anterior ambiguity. Results: Data of 46 patients were analyzed; those missing an appointment (n = 2) or showing bracket breakage (n = 2) were excluded. Incisor inclination (p < 0.05), intercanine width (p < 0.05), and intermolar width (p > 0.05) increased at 8 and 16 weeks in both the groups; no significant intergroup differences were noted (p > 0.05). Initial anterior irregularity index and intercanine width change were significantly associated with improvement in anterior irregularity (p < 0.001). Conclusions: The null hypothesis was rejected. Bracket type has little effect on improvement in anterior ambiguity during initial mandibular alignment.

Randomized controlled clinical trial of oral health-related quality of life in patients wearing conventional and self-ligating brackets

  • Othman, Siti Adibah;Mansor, Noorhanizar;Saub, Roslan
    • The korean journal of orthodontics
    • /
    • v.44 no.4
    • /
    • pp.168-176
    • /
    • 2014
  • Objective: The aim of this randomized controlled clinical trial was to compare oral health-related quality of life (OHRQoL) of patients treated with conventional, active self-ligating (ASL), and passive self-ligating (PSL) brackets in different therapeutic phases. Methods: Sixty patients (mean age 18.3 years; 29 males and 31 females) requiring orthodontic treatment were randomly and equally assigned to receive conventional (Victory Series), ASL (In-Ovation R), or PSL (Damon 3MX) brackets. OHRQoL was measured with a self-administered modified 16-item Malaysian version of the Oral Health Impact Profile for immediate (soon after the visit) and late (just before the subsequent visit) assessments of the bonding and activation phases. Data were analyzed with the Kruskal-Wallis and chi-square tests. Results: The PSL and ASL groups showed more immediate and late impacts in the bonding phase, respectively; the conventional group was affected in both the assessments. The first activation phase had similar impacts in the groups. After the second activation, the conventional group showed more immediate impacts, whereas the PSL and ASL groups had more late impacts. The commonly affected domains were "physical disability," "functional limitation," "physical pain," and "psychological discomfort." No significant differences in the prevalence and severity of immediate and late impacts on OHRQoL of the patients were noted in any therapeutic phase. Conclusions: No bracket system seems to ensure superior OHRQoL. This information could be useful for explaining the therapeutic phases, especially the initial one, and selecting the optimal bracket system based on the patient's preference.

Frictional property comparisons of conventional and self-ligating lingual brackets according to tooth displacement during initial leveling and alignment: an in vitro mechanical study

  • Kim, Do-Yoon;Lim, Bum-Soon;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.46 no.2
    • /
    • pp.87-95
    • /
    • 2016
  • Objective: We evaluated the effects of tooth displacement on frictional force when conventional ligating lingual brackets (CL-LBs), CL-LBs with a narrow bracket width, and self-ligating lingual brackets (SL-LBs) were used with initial leveling and alignment wires. Methods: CL-LBs (7th Generation), CL-LBs with a narrow bracket width (STb), and SL-LBs (In-Ovation L) were tested under three tooth displacement conditions: no displacement (control); a 2-mm palatal displacement (PD) of the maxillary right lateral incisor (MXLI); and a 2-mm gingival displacement (GD) of the maxillary right canine (MXC) (nine groups, n = 7 per group). A stereolithographic typodont system and artificial saliva were used. Static and kinetic frictional forces (SFF and KFF, respectively) were measured while drawing a 0.013-inch copper-nickel-titanium archwire through brackets at 0.5 mm/min for 5 minutes at $36.5^{\circ}C$. Results: The In-Ovation L exhibited lower SFF under control conditions and lower KFF under all displacement conditions than the 7th Generation and STb (all p < 0.001). No significant difference in SFF existed between the In-Ovation L and STb for a 2-mm GD of the MXC and 2-mm PD of the MXLI. A 2-mm GD of the MXC produced higher SFF and KFF than a 2-mm PD of the MXLI in all brackets (all p < 0.001). Conclusions: CL-LBs with narrow bracket widths exhibited higher KFF than SL-LBs under tooth displacement conditions. CL-LBs and ligation methods should be developed to produce SFF and KFF as low as those in SL-LBs during the initial and leveling stage.

Effects of self-ligating brackets and other factors influencing orthodontic treatment outcomes: A prospective cohort study

  • Jung, Min-Ho
    • The korean journal of orthodontics
    • /
    • v.51 no.6
    • /
    • pp.397-406
    • /
    • 2021
  • Objective: The purpose of this study was to evaluate the effects of self-ligating brackets (SBs) and other factors that influence orthodontic treatment outcomes. Methods: This two-armed cohort study included consecutively treated patients in a private practice. The patients were asked to choose between SBs and conventional brackets (CBs); if any patient did not have a preference, he or she was randomly allocated to the CB or SB group. All patients were treated using an identical archwire sequence. Evaluated parameters were as follows: treatment duration, number of bracket failures, poor oral hygiene, poor elastic wear, extraction, use of orthodontic mini-implants (OMI), OMI failure, American Board of Orthodontics (ABO) Discrepancy Index (DI), arch length discrepancy, and ABO Cast-Radiograph Evaluation (CRE) score. Stepwise regression analysis was performed to generate the equation for prediction of the CRE. Results: The final sample comprised 134 patients with an average age of 22.73 years. The average DI, CRE, and treatment duration were 21.81, 14.25, and 28.63 months, respectively. Analysis of covariance showed a significant difference in CRE between the CB and SB groups after adjusting for the effects of confounding variables. Stepwise regression analysis using four variables, namely extraction, SB use, poor elastic wear, and additional appliance use, could explain only 25.2% of the variance in the CRE. Conclusions: Although the CRE was significantly better for CBs than for SBs, the clinical significance of this result seems to be limited. Extraction, SB use, poor elastic wear, and additional appliance use may have significant effects on treatment outcomes.

In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment

  • Cordasco, Giancarlo;Giudice, Antonino Lo;Militi, Angela;Nucera, Riccardo;Triolo, Giuseppe;Matarese, Giovanni
    • The korean journal of orthodontics
    • /
    • v.42 no.4
    • /
    • pp.218-224
    • /
    • 2012
  • Objective: To investigate the resistance to sliding (RS) in self-ligating and conventional ligation bracket systems at 5 different second-order bracket angulations by using low-stiffness alignment wires in a 3-bracket experimental model and to verify the performance of the main RS components in both systems when these wires are used. Methods: Interactive self-ligating brackets with closed and open slides were used for the self-ligating (SL) and conventional ligation (CL) groups, respectively; elastomeric ligatures (1 mm inner diameter) were used in the latter system. The alignment wire used was 0.014 inch heat-activated NiTi (austenitic finish temperature set at $36^{\circ}C$ by the manufacturer). A custom-made testing machine was used to measure frictional resistance. Tests were repeated 5 times at every angulation simulated. All data were analyzed statistically. Results: The RS increased significantly with increasing angulation in both SL and CL groups (p < 0.0001). However, the RS values were significantly higher at every angulation (p < 0.0001) in the CL group. Conclusions: Despite the relevance of the binding phenomenon, ligation forces predominantly affect the RS when lowstiffness alignment wires are used.