• 제목/요약/키워드: Self-Diagnostic

검색결과 339건 처리시간 0.039초

PDA 기반의 차량 진단신호의 원격 계측 (Remote Measurement for Automobile′s ECU Diagnostic Signals based on the PDA)

  • 윤여흥;서지원;이현호;권대규;이영춘
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.279-282
    • /
    • 2002
  • In this paper, we present a new method for monitoring of ECU's self diagnostic signals of vehicle without wire. In order to measure the ECU's self diagnostic signals, the interfaced circuit is designed to communicate ECU and a designed display terminal according to the ISO, SAE regulation of communication protocol standard. A 80C196KC processor is used for communicating ECU's self diagnostic signals and the results are sent to PDA monitoring system. Software on PDA is developed to monitor the ECU's self diagnostic signals using the Embedded Visual C++ compiler in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self diagnostic signals are verified to monitor ECU's state. At the same time, the information to fix the vehicle's problem can be shown on the developed PDA software. The possibility for remote measurement of ECU self diagnostic signal using PDA is also verified through the developed systems and algorithms.

  • PDF

자동차 ECU 자기진단 신호의 원격계측 시스템 (Remote Measuring System for Automobile′s ECU Self Diagnostic Signal)

  • 정진호;윤여흥;이영춘;권대규;이성철
    • 한국정밀공학회지
    • /
    • 제19권5호
    • /
    • pp.159-167
    • /
    • 2002
  • In this paper. we present a new method for monitoring of ECU's self diagnostic signals of vehicle without wire. In order to measure the ECU's self diagnostic signals, the interfaced circuit is designed to communicate ECU and designed terminal according to the IOS, SAE regulation of communication protocol standard. Micro-processor 80C196KC is used for communicating ECU's self diagnositc signals and the results are sent to the wireless terminal and PC monitoring system. Wireless terminal is also developed by 80C196KC, LCD, RF module, and keypad. The command from the keypad is sent to ECU through RF module and the result show on the Graphic LCD in real time. Software on PC is developed to monitor the ECU's self diagnostic signals using the Visual C++ complier in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self diagnostic signals are verified to monitor both ECU and portable terminal state. At the same time, the information to fix the vehicle's problem can be shown on the developed software. The possibility for remote measurement of ECU self diagnostic signal is verified through the developed systems and algorithms.

Remote Measurement of ECU Self-Diagnostic Signal based on the Windows CE

  • Lee, Seong-Cheol;Yun, Yeo-Hung;Se, Ji-Won;Kwon, Tae-Kyu;Lee, Young-Chun;Jang, Bong-Choon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.68.2-68
    • /
    • 2002
  • The purpose of this paper is to monitor ECU's self-diagnostic signal without wire. In order to measure the ECU's self-diagnostic signal, the interfaced circuit is developed to communicate ECU with a designed display terminal according to the ISO, SAE regulation of communication protocol standard. An 80C196KC processor is used for communicating ECU's self-diagnostic signal and communication data are sent to PDA monitoring system that is based on the Windows CE. Software on PDA is developed to monitor the ECU's self-diagnostic signal in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self-diagnostic signals are verified to mo...

  • PDF

DEVELOPMENT OF A MAJORITY VOTE DECISION MODULE FOR A SELF-DIAGNOSTIC MONITORING SYSTEM FOR AN AIR-OPERATED VALVE SYSTEM

  • KIM, WOOSHIK;CHAI, JANGBOM;KIM, INTAEK
    • Nuclear Engineering and Technology
    • /
    • 제47권5호
    • /
    • pp.624-632
    • /
    • 2015
  • A self-diagnostic monitoring system is a system that has the ability to measure various physical quantities such as temperature, pressure, or acceleration from sensors scattered over a mechanical system such as a power plant, in order to monitor its various states, and to make a decision about its health status. We have developed a self-diagnostic monitoring system for an air-operated valve system to be used in a nuclear power plant. In this study, we have tried to improve the self-diagnostic monitoring system to increase its reliability. We have implemented three different machine learning algorithms, i.e., logistic regression, an artificial neural network, and a support vector machine. After each algorithm performs the decision process independently, the decision-making module collects these individual decisions and makes a final decision using a majority vote scheme. With this, we performed some simulations and presented some of its results. The contribution of this study is that, by employing more robust and stable algorithms, each of the algorithms performs the recognition task more accurately. Moreover, by integrating these results and employing the majority vote scheme, we can make a definite decision, which makes the self-diagnostic monitoring system more reliable.

지구과학 수업에서 진단 및 형성평가 활용을 위한 스마트 맞춤 평가(SPA) 시스템의 개발 및 효과 (Development and Effects of Smart Personalized Assessment(SPA) System for Using of Diagnostic and Formative Assessment in Earth Science Classes)

  • 손준호;김종희
    • 대한지구과학교육학회지
    • /
    • 제9권1호
    • /
    • pp.1-14
    • /
    • 2016
  • The purpose of this study is to develop SPA system using diagnostic and formative assessment in earth science classes in order to discuss its effect on learning achievement and self-directed learning attitude. For this purpose, we developed total management system, app for teachers, and app for students. This research was practiced to 76 students in 5th grade. The results are as follows. Firstly, the group taking a class used by app for diagnostic and formative assessment had an effect of improving learning achievement. However, as for learning achievement long term endurance test, the group taking a class using app for diagnostic and formative assessment had no effect. Secondly, the group taking a class using apps for diagnostic and formative assessment had an effect of improving learners' self-directed learning attitude. As for self-directed long-term endurance test, the group taking a class using app for diagnostic and formative assessment had an effect. In conclusion, I hope that this SPA system might apply to the science classes as it is a system that will satisfy the needs of both teachers and students, giving much needed feedback to students.

원자력발전소 안전필수시스템 고장허용능력에 대한 자가진단기능 저하 영향 분석 (The Effect of the Fault Tolerant Capability due to Degradation of the Self-diagnostics Function in the Safety Critical System for Nuclear Power Plants)

  • 허섭;황인구;이동영;최헌호;김양모;이상정
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1456-1463
    • /
    • 2010
  • The safety critical systems in nuclear power plants should be designed to have a high level of fault tolerant capability because those systems are used for protection or mitigation of the postulated accidents of nuclear reactor. Due to increasing of the system complexity of the digital based system in nuclear fields, the reliability of the digital based systems without an auto-test or a self-diagnostic feature is generally lower than those of analog system. To overcome this problem, additional redundant architectures in each redundant channel and self-diagnostic features are commonly integrated into the digital safety systems. The self diagnostic function is a key factor for increasing fault tolerant capabilities in the digital based safety system. This paper presents an availability and safety evaluation model to analyze the effect to the system's fault tolerant capabilities depending on self-diagnostic features when the loss or erroneous behaviors of self-diagnostic function are expected to occur. The analysis result of the proposed model on the several modules of a safety platform shows that the improvement effect on unavailability of each module has generally become smaller than the result of usage of conventional models and the unavailability itself has changed significantly depending on the characteristics of failures or errors of self-diagnostic function.

RF 모듈을 이용한 ECU 자기진단 신호의 원격 계측 (Remote Measurement for ECU Self Diagnostic Signal by RF Module)

  • 정진호;이영춘;윤여흥;권대규;이우열;이성철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.231-234
    • /
    • 2001
  • OBD-II regulations are already effective in many countries. The California Air Resources Board(CARB) first issued regulations in 1985 for the 1988 model year, known as OBD-I, and required the vehicle's engine management computer to warn the driver by means of a dash-mounted light if a malfunction occurred in either the oxygen sensor, the exhaust gas recirculation(EGR) valve or the evaporative emission system purge solenoid, and to store information on troubles that have no recurrent characteristics. This paper presents two methods of wireless monitoring OBD signal, which is one of the ECU output for self diagnostic measurement. RF module is used to monitor ECU's Self diagnostic signal remotely. Two kinds of measurement systems which are based on micro-controller(80C196KC) for portable detection and PC for sever are considered for receiving the RF signal. Therefore, possibility of real-time monitoring of ECU's self diagnostic signal remotely is verified on this paper.

  • PDF

공과대학 신입생의 자기주도학습준비도와 수학기초학력평가성적 및 대학수학학업성취도 관계 연구 (A Study of Relationship between SDLR, the Score of Mathematics Diagnostic Assesment and Achievement in College Mathematics of Engineering Students)

  • 이경희;권혁홍
    • 공학교육연구
    • /
    • 제16권1호
    • /
    • pp.54-63
    • /
    • 2013
  • This study aims to investigate relationships among self-directed learning readiness [SDLR], prerequisite mathematics test score and achievement level in college mathematics. For this purpose, the adjusted SDLRS (self-directed learning readiness scale) of Guglielmino's model, the score of mathematics diagnostic assesment and first semester college mathematics score among 424 freshmen students of engineering department of D university in 2011 were used and analyzed. Research results are as follows: Firstly, freshmen of engineering department had average level of SDLR, though they showed relative low level of self-direction, passion and time control ability. Secondly, considering SDLR with the mathematics diagnostic assesment score (3 groups: high, middle, low), there were no statistically significant differences. Thirdly, concerning SDLR according to the achievement level in college mathematics, a group which acquired good achievement showed higher level of SDLR compared with middle or lowachievement group. Differences among three groups were statistically significant. Lastly, there were affirmative relationships between SDLR, mathematics diagnostic assesment score and achievement in college mathematics. Furthermore, mathematics diagnostic assesment score and achievement level in college mathematics were found to be the most closely related. Based on the results, we suggest strategies to elevate SDLR of engineering department students and improve their achievement in college mathematics.

화병 임상진료지침 III. (화병의 진단과 평가) (Clinical Guidelines for Hwabyung III. (Diagnosis and Assessment of Hwabyung))

  • 정인철;최우창;이상룡
    • 동의신경정신과학회지
    • /
    • 제24권spc1호
    • /
    • pp.23-36
    • /
    • 2013
  • Objectives : The purpose of this guideline is to show the evidence-based guidelines of diagnosis and evaluation of Hwabyung by the synthesis and organization of existing research contents. Methods : We investigated the existing research on the concept of Hwabyung. Further, we investigated the diagnostic tools, self-diagnostic method, symptoms assessment tools, oriental medical diagnostic methods, treatment evaluation tools and other testing methods of Hwabyung. Results : There was a Hwabyung diagnostic interview schedule (HIBDS) in the standardized measure for the diagnosis of Hwabyung. In the symptoms assessment tools of Hwabyung, there was a self-report measurement tool of Hwabyung and measurement tool of Hwabyung to be evaluated by the interviewer. In the oriental medical diagnostic method, there was an instrument of pattern identification for Hwabyung. In the treatment assessment tool, there was an instrument of oriental medical evaluation for Hwabyung. In addition, MMPI, SCL-90R, Zung's self-rating anxiety scale (SAS), Zung's self-rating depression scale (SDS), State-Trait Anger Expression Inventory (STAXI) and etc. can be used for the diagnosis and assessment of Hwabyung. Conclusions : We expect 'Clinical Guidelines for the Treatment of Hwabyung' to be useful for the diagnosis and assessment of Hwabyung.

Self-Diagnostic Signal Monitoring System of KWP2000 Vehicle ECU using Bluetooth

  • Choi, Kwang-Hun;Lee, Hyun-Ho;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.132-137
    • /
    • 2004
  • On-Board Diagnostic(OBD) systems are in most cars and light trucks on the load today. During the 1970's and early 1980's manufacturers started using electronic means to control engine functions and diagnose engine problems. The CARB's diagnostic requirements to meet EPA emission standards have been designated as OBD with a goal of monitoring all of the emissions-related components, as well as the chassis, body, accessory devices and the diagnostic control network of the vehicle for proper operation. In this paper, we present a remote measurement system for the wireless monitoring of diagnosis signal and sensors output signals of ECU adopted KWP2000, united the OBD communication protocol, on OBD-compliant vehicle using the wirless communication technique of Bluetooth. In order to measure the ECU signals, the interface circuit is designed to communicate ECU and designed terminal wirelessly according to the ISO, SAE regulation of communication protocol standard. A microprocessor S3C3410X is used for communicating ECU signals. The embedded system's software is programmed to measure the ECU signals using the ARM compiler and ANCI C based on MicroC/OS kernel to communicate between bluetooth modules using bluetooth stack. The diagnostic system is developed using Visual C++ MFC and protocol stack of bluetooth for Windows environment. The self-diagnosis and sensor output signals of ECU is able to monitor using PC with bluetooth board connected in serial port of PC. The algorithms for measuring the ECU sensor output and self-diagnostic signals are verified to monitor ECU state. At the same time, the information to fix the vehicle's problem can be shown on the developed monitoring software. The possibility for remote measurement of self-diagnosis and sensor signals of ECU adopted KWP2000 in embedded system verified through the developed systems and algorithms.

  • PDF