• Title/Summary/Keyword: Self Noise

Search Result 575, Processing Time 0.029 seconds

A Study on the Possibility of the Earthquake Detection based on Telluric Current Monitoring (지전류 모니터링 기반 지진 감지 가능성 연구)

  • Noh, Myounggun;Lee, Heuisoon;Ahn, Taegyu;Jun, Seokang;Chung, Hojoon
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.3
    • /
    • pp.107-115
    • /
    • 2019
  • Recently, since earthquakes have happened frequently in Gyeongju and Pohang areas in Korea, the earthquake detection research gets lots of attention. Geophysical monitoring data have been changed during the earthquake activity because the huge amount of energy is accumulated. The change of telluric current can be predicted by both of piezoelectric and electrokinetic effects before or during the earthquake occurrence, and if the change value exceeds the conventional telluric current noise, we can measure changes in the electric field associated with earthquakes. In this study, we have self-developed and verified the system that can monitor the telluric current. In order to verify our telluric current monitoring system, we installed lines of 40 m (E-W direction) and 28 m (N-S direction) on the site in Pohang. The telluric currents were sampled at 1 kHz for about a month. We have compared and analyzed the data of earthquake signals and electrical noises based on the earthquakes that occurred during the monitoring period. We have monitored if there were significant signals related to the earthquake on measured time series data. Through this study, we will suggest the direction of continuous research in the future.

Wideband Receiver Module for LADAR Using Large Area InGaAs Avalanche Photodiode (대면적 APD를 이용한 LADAR용 광대역 광수신기)

  • Park, Chan-Yong;Kim, Dug-Bong;Kim, Chung-Hwan;Kwon, Yongjoon;Kang, EungCheol;Lee, Changjae;Choi, Soon-Gyu;La, Jongpil;Ko, Jin Sin
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • In this paper, we report design, fabrication and characterization of the WBRM (Wide Band Receiver Module) for LADAR (LAser Detection And Ranging) application. The WBRM has been designed and fabricated using self-made APD (Avalanche Photodiode) and TIA (Trans-impedance Amplifier). The APD and TIA chips have been integrated on 12-pin TO8 header using self-made ceramic submount and circuit. The WBRM module showed 450 ps of rise time, and corresponding 780 MHz bandwidth. Furthermore, it showed very low output noise less than 0.8 mV, and higher SNR than 15 for 150 nW of MDS(Minimum Detectable Signal). To the author's knowledge, this is the best performance of an optical receiver module for LIDAR fabricated by 200 um InGaAs APD.

A Strategic Quality Initiative and Its Opportunities to Improve Healthcare Environment (진료환경개선을 위한 우선적 전략과제 설정 및 그 적용)

  • Tark, Kwan-Chul;Park, Hyun-Ju;Park, Chang-Il;Kang, Jin-Kyung
    • Quality Improvement in Health Care
    • /
    • v.5 no.2
    • /
    • pp.324-334
    • /
    • 1998
  • Background : Strategic planning is an organizationwide or systemwide, ongoing look into the future usually of 2~3 years, based on objective analysis of the current environment and trends, but it can incorporate both short-term and long-term goals. The strategic planning process includes external analysis, internal analysis, issue analysis, development of mission, vision and values, and lastly development of organizational goals and objectives. As a part of the strategic quality planning process, certain service lines, important organizationwide functions, or key processes supporting these functions can be prioritized to expedite and roll out certain strategic goals. This is called strategic quality initiatives. Methods : We organized a quality improvement team, a subgroup of 21st century vision planning corps of our medical center, and pursued QI activities for improvement of healthcare environment, particularly in the admission setting. We developed a strategic quality initiative based on the results of patient satisfaction surveys, and carried out functions of self-directed work team. Results : The strategic goal was to be the benchmark for peer group hospitals in Korea for providing cost-effective best-practice. The QI team included 3 medical doctors, 1 nurse, 1 social worker, and 1 QI consultant as well as many operational members to support services and quality initiatives met every Tuesday for 18 weeks. Outcome objectives were to improve patient satisfaction score. The issues included in the objectives were comfort, temperature, noise, cleanliness of the admission wards, quality and education of patient meals, matters regarding the admission process, and an appurtenant facility such as restaurant or convenience store. Every issue was discussed and recommendations, conclusions and opportunities were implemented. Conclusions : By developing a strategic quality initiative as a part of the strategic quality planning process, and pursuing a self-directed work team, certain sen/ice lines, important organizationwide functions, or key processes supporting these functions can be improved effectively within a short period. Strategic quality initiatives serve to support, or roll out, certain strategic goals that are relevant to performance improvement and development of specific measurable outcome objectives, and associated performance measure for each initiative. Each strategic quality initiative should include a statement of intent outcome objectives, and performance measures. We will come back with follow up of the strategic quality initiative, for improvement of healthcare environment, and results of patient satisfaction re-survey.

  • PDF

Development of Automatized Quantitative Analysis Method in CT Images Evaluation using AAPM Phantom (AAPM Phantom을 이용한 CT 영상 평가 시 자동화된 정량적 분석 방법 개발)

  • Noh, Sung Sun;Um, Hyo Sik;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.163-173
    • /
    • 2014
  • When evaluating the spatial resolution images and evaluation of low contrast resolution using CT standard phantom, and might present a automated quantitative evaluation method for minimizing errors by subjective judgment of the evaluator be, and try to evaluate the usefulness. 120kVp and 250mAs, 10mm collimation, SFOV(scan field of view) of 25cm or more than, exposure conditions DFOV(display field of view) of 25cm, and were evaluated the 24 passing images and 20 failing images taken using a standard reconstruction algorithm by using the Nuclear Associates, Inc. AAPM CT Performance Phantom(Model 76-410). Quantitative evaluation of low contrast resolution and spatial resolution was using an evaluation program that was self-developed using the company Mathwork Matlab(Ver. 7.6. (R2008a)) software. In this study, the results were evaluated using the evaluation program that was self-developed in the evaluation of images using CT standard phantom, it was possible to evaluate an objective numerical qualitative evaluation item. First, if the contrast resolution, if EI is 0.50, 0.51, 0.52, 0.53, as a result of evaluating quantitatively the results were evaluated qualitatively match. Second, if CNR is -0.0018~-0.0010, as a result of evaluating quantitatively the results were evaluated qualitatively match. Third, if the spatial resolution, as a result of using a image segmentation technique, and automatically extract the contour boundary of the hole, as a result of evaluating quantitatively the results were evaluated qualitatively match.

Dynamic Analysis and Evaluation of a Microgyroscope using Symmetric 2DOF Planar Resonator (대칭형 2자유도 수평 공진기를 이용한 마이크로 자이로스코프의 동특성 해석 및 평가)

  • Hong, Yoon-Shik;Lee, Jong-Hyun;Kim, Soo-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Conventional microgyroscopes of vibrating type require resonant frequency tuning of the driving and sensing modes to achieve high sensitivity. These tuning conditions depend on each fabricated microgyroscopes, even though the microgyroscopes are identically designed. A new micromachined resonator, which is applicable to microgyroscopes with self-toning characteristics, is presented. Since the laterally driven two degrees of freedom (2DOF) resonator was designed as a symmetric structure with identical stiffness in two orthogonal axes, the resonator is applicable to vibrating microgyroscopes, which do not need mode tuning. A dynamic model of the resonator was derived considering gyroscopic application. The dynamic model was evaluated by experimental comparison with fabricated resonators. The microgyroscopes were fabricated using a simple 2-mask-process of a single polysilicon layer deposited on an insulator layer. The feasibility of the resonator as a vibrating microgyroscopes with self-tuning capability is discussed. The fabricated resonators of a particular design have process-induced non-uniformities that cause different resonant frequencies. For several resonators, the standard deviations of the driving and sensing frequencies were as high as 1232Hz and 1214Hz, whereas the experimental average detuning frequency was 91.75Hz. The minimum detuned frequency was 68Hz with $0.034mVsec/^{\circ}$ sensitivity. The sensitivity of the microgyroscopes was low due to process-induced non-uniformity; the angular rate bandwidth, however, was wide. This resonator could be successfully applicable to a vibrating microgyroscopes with high sensitivity, if improvements in uniformity of the fabrication process are achieved. Further developments in improved integrated circuits are expected to lower the noise level even more.

  • PDF

Effects of Cognitive Impairment on Self-reported Hearing Handicap in Older Adults with Early-stage Presbycusis (초기 노인성 난청자에서 인지장애가 일상생활 듣기 어려움에 미치는 영향)

  • Lee, Soo Jung
    • 한국노년학
    • /
    • v.38 no.1
    • /
    • pp.1-14
    • /
    • 2018
  • Everyday hearing handicap caused by presbycusis ultimately reduces quality of life in older adults. The aim of this study was to explore effects of cognitive impairment on self-reported hearing handicap in older adults with early-stage presbycusis. We compared K-HHIE scores between 40 elderly subjects with mild cognitive impairment (MCI) and age- and hearing-threshold matched 40 cognitively normal elderly (CNE) subjects. The results are as follows: 1) The MCI group scored significantly higher than the CNE group on the social/situational and emotional sections, and in total. 2) The MCI group scored significantly higher than the CNE group on all four subscales, and the most significant group difference was on the first subscale relating to interpersonal relationships and social handicaps. 3) Both groups scored highest on the item 8 (problems hearing whispering sounds) and item 15 (problems hearing TV or radio sounds). Besides those two items, the MCI group also scored high on the item 21 (problems hearing in a restaurant), item 6 (problems hearing when attending a party), item 3 (avoiding groups of people), and item 20 (personal or social restrictions). Our findings suggest that, among older adults with early-stage presbycusis, older adults with cognitive impairment tend to report greater everyday hearing handicap than their peers with normal cognitive function. Especially, they show significant problems hearing in background noise or multi-talker situations, which cause social restrictions and social/emotional loneliness.

A Modified Decision-Directed LMS Algorithm (수정된 DD LMS 알고리즘)

  • Oh, Kil Nam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.3-8
    • /
    • 2016
  • We propose a modified form of the decision-directed least mean square (DD LMS) algorithm that is widely used in the optimization of self-adaptive equalizers, and show the modified version greatly improves the initial convergence properties of the conventional algorithm. Existing DD LMS regards the difference between a equalizer output and a quantization value for it as an error, and achieves an optimization of the equalizer based on minimizing the mean squared error cost function for the equalizer coefficients. This error generating method is useful for binary signal or a single-level signals, however, in the case of multi-level signals, it is not effective in the initialization of the equalizer. The modified DD LMS solves this problem by modifying the error generation. We verified the usefulness and performance of the modified DD LMS through experiments with multi-level signals under distortions due to intersymbol interference and additive noise.

Implement of Hand Gesture Interface using Ratio and Size Variation of Gesture Clipping Region (제스쳐 클리핑 영역 비율과 크기 변화를 이용한 손-동작 인터페이스 구현)

  • Choi, Chang-Yur;Lee, Woo-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.121-127
    • /
    • 2013
  • A vision based hand-gesture interface method for substituting a pointing device is proposed in this paper, which is used the ratio and size variation of Gesture Region. Proposed method uses the skin hue&saturation of the hand region from the HSI color model to extract the hand region effectively. This method can remove the non-hand region, and reduces the noise effect by the light source. Also, as the computation quantity is reduced by detecting not the static hand-shape recognition, but the ratio and size variation of hand-moving from the clipped hand region in real time, more response speed is guaranteed. In order to evaluate the performance of the our proposed method, after applying to the computerized self visual acuity testing system as a pointing device. As a result, the proposed method showed the average 86% gesture recognition ratio and 87% coordinate moving recognition ratio.

A Fuzzy Neural Network Model Solving the Underutilization Problem (Underutilization 문제를 해결한 퍼지 신경회로망 모델)

  • 김용수;함창현;백용선
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.11 no.4
    • /
    • pp.354-358
    • /
    • 2001
  • This paper presents a fuzzy neural network model which solves the underutilization problem. This fuzzy neural network has both stability and flexibility because it uses the control structure similar to AHT(Adaptive Resonance Theory)-l neural network. And this fuzzy nenral network does not need to initialize weights and is less sensitive to noise than ART-l neural network is. The learning rule of this fuzzy neural network is the modified and fuzzified version of Kohonen learning rule and is based on the fuzzification of leaky competitive leaming and the fuzzification of conditional probability. The similarity measure of vigilance test, which is performed after selecting a winner among output neurons, is the relative distance. This relative distance considers Euclidean distance and the relative location between a datum and the prototypes of clusters. To compare the performance of the proposed fuzzy neural network with that of Kohonen Self-Organizing Feature Map the IRIS data and Gaussian-distributed data are used.

  • PDF

Observation of the Earth's Magnetic field from KOMPSAT-1

  • Hwang, Jong-Sun;Kim, Sung-Yong;Lee, Seon-Ho;Min, Kyung-Duck;Kim, Jeong-Woo;Lee, Su-Jin
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1236-1238
    • /
    • 2003
  • The Earth's total magnetic field was extracted from on board TAM (Three Axis Magnetometer) observations of KOMPSAT-1 satellite between June 19th and 21st, 2000. In the pre-processing, the TAM's telemetry data were transformed from ECI (Earth Centered Inertial frame) to ECEF (Earth Centered Earth Fixed frame) and then to spherical coordination, and self-induced magnetic field by satellite bus itself were removed by using an on-orbit magnetometer data correction method. The 2-D wavenumber correlation filtering and quadrant-swapping method were applied to the pre-processed data in order to eliminate dynamic components and track-line noise, respectively. Then, the spherical harmonic coefficients are calculated from KOMPSAT-1 data. To test the validity of the TAM's geomagnetic field, Danish/NASA/French ${\phi}$rsted satellite's magnetic model and IGRF2000 model were used for statistical comparison. The correlation coefficient between ${\phi}$rsted and TAM is 0.97 and IGRF and TAM is 0.96. It was found that the data from on board magnetometer observations for attitude control of Earth-observing satellites can be used to determinate the Earth's total magnetic field and that they can be efficiently used to upgrade the global geomagnetic field coefficients, such as IGRF by providing new information at various altitudes with better temporal and spatial coverage.

  • PDF