• Title/Summary/Keyword: Selective design

Search Result 594, Processing Time 0.028 seconds

A PN-code Acquisition method Using Array Antenna Systems for CDMA2000 1x (CDMA2000 1x용 배열 안테나 시스템에서 PN 동기 획득 방법)

  • Jo, Hee-Nam;Yun, Yu-Suk;Choi, Seung-Won
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.8 s.338
    • /
    • pp.33-40
    • /
    • 2005
  • This paper presents a structure of the searcher using a diversity in array antenna systems operating in the cdma2000 1x signal environments. The new technique exploits the fact that the In-phase and quadrature components of interferers can respectively be viewed as an independent gaussian noise at each antnna element in most practical cdma signal environments. The proposed PN acquisition scheme is a singles-dwell PN acquisition system consisting of two stages, that is, the searching stage and the verification stage. The searching stage independently correlates the receiver multiple signals with PN generator of each antenna element for obtaining the synchronous energy at the entire region. Then, the searching results of each antenna element are non-coherently combinind. The verification stage compares the searching energy with the optimal threshold, which is predesigned in the lock detector, and decides whether the acquisition is successful or fail. In this paper, we analyzed the effect of tile diversity order to determine the mean acquisition time. In general, it is known that the mean acquisition time significantly decrease as the number of antenna elements increases. But, as the diversity order goes up, the enhancement of the performance is saturated. Therefore, to decrease the mean acquisition time of the searcher, we must design the optimal array antenna systems by considering the operating SNR range of the receiver, the probability of detection $P_D$ and that of false alarm $P_{FA}$ . The Performance of the proposed PN acquisition scheme is analyzed in frequency selective Rayleigh fading channels. In this paper, the effect of the number of antenna elements on PN acquisition scheme is shown according to the probability of detection $P_D$ and that of false alarm $P_{FA}$.

Systematic Review of the Cause of Drug-Induced Liver Injuries in Korean Literature (약인성 간손상의 원인물질에 관한 국내연구의 체계적 고찰)

  • Yun, Young-Ju;Shin, Byung-Cheul;Lee, Myeong-Soo;Cho, Sung-Il;Park, Jae-Hyeon;Lee, Hye-Jung
    • The Journal of Korean Medicine
    • /
    • v.30 no.2
    • /
    • pp.30-45
    • /
    • 2009
  • Background: The safety of herbal products is an important issue in Korea. It is more complicated because of the concomitant use of conventional western drugs and herbal medicine, including prescribed medicine, folk herbs and food supplements. Although both western and traditional Korean medical doctors have studied on the safety of HMP, their results did not show relevant or consistent conclusions because of the poor quality of studies, including bias. Objectives: The aim of this study was to review the studies in Korea related to drug induced liver injury (DILI) systematically. We tried to estimate the proportion of causative materials of DILI and evaluate the clinical difference of DILIs from different materials. Methods: Systematic searches were performed on MedRIC and MEDLIS in Korea. The extraction of data as well as selective screening of the studies was carried out independently by two of the authors. There were no restrictions on the types of publication, including grey literature. Results: Twenty-one articles were included. Of them only 7 adapted prospective design and only 6 were published in peer-reviewed journals. The proportion of conventional drugs associated with hepatotoxic injuries in all DILI ranged from 15.8% to 83.3% and that of herbal medicine was from 28.9% to 44.7%. However, the criteria for herbal medicine were not clearly defined and concomitant medications were not fully investigated in most studies. There were limited objective data in the clinical differences of liver injuries from different materials and their results were conflicting. Conclusions: The causality assessments regarding DILI of herbal medicine were not performed properly and causative materials were misclassified in most of the studies published in Korea. These make the safety issue still ambiguous because of the limitations and lack of objectivity of the studies. More rigorous studies are required for clearly addressing these conflicting issues with cooperative investigation between traditional Korean and western medicine.

  • PDF

Design of a Band-Stop Filter for UWB Application (UWB용 대역 저지 필터 설계)

  • Roh Yang-Woon;Hong Seok-Jin;Chung Kyung-Ho;Jung Ji-Hak;Choi Jae-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.2 s.105
    • /
    • pp.89-94
    • /
    • 2006
  • A compact microstrip band-selective filter for ultra-wideband(UWB) radio system is proposed. The filter combines the traditional short-circuited stub highpass filter and coupled resonator band-stop filter on both sides of the mitered 50-ohm microstrip line. To realize the pseudo-highpass filtering characteristic over UWB frequency band(3.1 GHz to 10.6 GHz), a distributed highpass filter scheme is adopted. Three coupled resonators are utilized to obtain the band stop function at the desired frequency band. By meandering the coupled resonators, there is $29\;\%$ size reduction in footprint compared to the traditional band-stop filter using L-shaped resonators. The measured results show that the filter has a wide passband of $146.7\;\%$(2.1 GHz to 10.15 GHz) with low insertion loss and the stop band of $10.04\;\%$(5.2 GHz to 5.75 GHz) for 3-dB bandwidth. The measured group delay is less than 0.7 ns within the passband except the rejection band.

Real-time Nucleic Acid Sequence Based Amplification (Real-time NASBA) for Detection of Norovirus

  • Lee, In-Soo;Choi, Dong-Hyuk;Lim, Jae-Won;Cho, Yoon-Jung;Jeong, Hye-Sook;Cheon, Doo-Sung;Bang, Hye-Eun;Jin, Hyun-Woo;Choi, Yeon-Im;Park, Sang-Jung;Kim, Sung-hyun;Lee, Hye-Young;Kim, Tae-Ue
    • Biomedical Science Letters
    • /
    • v.17 no.3
    • /
    • pp.191-196
    • /
    • 2011
  • Noroviruses (noroV) are the major cause of nonbacterial gastroenteritis in humans worldwide. Since noroV cannot yet be cultured in vitro and their diagnosis by electron microscopy requires at least $10^6$ viral particles/g of stool a variety of molecular detection techniques represent an important step towards the detection of noroV. In the present study, we have applied real-time nucleic acid sequence-based amplification (real-time NASBA) for simultaneous detection of NoroV genogroup I (GI) and genogroup II (GII) using standard viral RNA. For real-time NASBA assay which can detected noroV GI and GII, a selective region of the genes encoding the capsid protein was used to design primers and genotype-specific molecular beacon probes. The specificity of the real-time NASBA using newly designed primers and probes were confirmed using standard viral RNA of noroV GI and GII. To determine the sensitivity of this assay, serial 10-fold dilutions of standard viral RNA of noroV GI and GII were used for reverse transcription polymerase chain reaction (RT-PCR) and real-time NASBA. The results showed that while agarose gel electrophoresis could detect RT-PCR products with 10 pg of standard viral RNA, the real-time NASBA assay could detect 100 fg of standard viral RNA. These results suggested that the real-time NASBA assay has much higher sensitivity than conventional RT-PCR assay. This assay was expected that might detect the viral RNA in the specimens which could have been false negative by RT-PCR. There were needed to perform real-time NASBA with clinical specimens for evaluating accurate sensitivity and specificity of this assay.

An Agroclimatic Data Retrieval and Analysis System for Microcomputer Users(CLIDAS) (퍼스컴을 이용한 농업기후자료 검색 및 분석시스템)

  • 윤진일;김영찬
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.3
    • /
    • pp.253-263
    • /
    • 1993
  • Climatological informations have not been fully utilized by agricultural research and extension workers in Korea due mainly to inaccessbilty to the archived climate data. This study was initiated to improve access to historical climate data gathered from 72 weather stations of Korea Meteorological Administration for agricultural applications by using a microcomputer-based methodology. The climatological elements include daily values of average, maximum and minimum temperature, relative humidity, average and maximum wind speed, wind direction, evaporation, precipitation, sunshine duration and cloud amount. The menu-driven, user-friendly data retrieval system(CLIDAS) provides quick summaries of the data values on a daily, weekly and monthly basis and selective retrieval of weather records meeting certain user specified critical conditions. Growing degree days and potential evapotranspiration data are derived from the daily climatic data, too. Data reports can be output to the computer screen, a printer or ASCII data files. CLIDAS can be run on any IBM compatible machines with Video Graphics Array card. To run the system with the whole database, more than 50 Mb hard disk space should be available. The system can be easily upgraded for further expansion of functions due to the module-structured design.

  • PDF

Validation of an HPLC Method for the Pharmacokinetic Study of Glipizide in Human (글리피짓 체내동태 연구를 위한 혈청 중 글리피짓의 HPLC 정량법 검증)

  • Cho, Hea-Young;Lee, Hwa-Jeong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.3
    • /
    • pp.137-142
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of glipizide in human serum was validated and applied to the pharmacokinetic study of glipizide. Glipizide and internal standard, tolbutamide, were extracted from human serum by liquid-liquid extraction with benzene and analyzed on a Nova Pak $C_{18}\;60{\AA}$ column with the mobile phase of acetonitrile-potassium dihydrogen phosphate (10 mM, pH 3.5) (4:6, v/v). Detection wavelength of 275 nm and flow rate of 0.7 ml/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^3$ factorial design using a fixed glipizide concentration (500 ng/ ml) with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 10-1000 ng/ml with correlation coefficient greater than 0.999. The lower limit of quantitation using 0.5 ml of serum was 10.0 ng/ml, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 82.6 to 105.0% for glipizide with overall precision (% C.V.) being 1.13-13.20%. The percent recovery for human serum was in the range of 85.2 93.5%. Stability studies showed that glipizide was stable during storage, or during the assay procedure in human serum. The peak area and retention time of glipizide were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of glipizide in human serum samples for the pharmacokinetic studies at three different laboratories, demonstrating the suitability of the method.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Fexofenadine in Human (테르페나딘 체내동태 연구를 위한 혈청 중 펙소페나딘의 HPLC 정량법 개발 및 검증)

  • Cho, Hye-Young;Kang, Hyun-Ah;Kim, Yoon-Gyoon;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.6
    • /
    • pp.437-443
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of a major metabolite of terfenadine, fexofenadine, in human serum was developed, validated, and applied to the pharmacokinetic study of terfenadine. Fexofenadine and internal standard, haloperidol were extracted from human serum by liquid-liquid extraction with acetonitrile and analyzed on a $Symmetry^{TM}$ C8 column with the mobile phase of 1% triethylamine phosphate (pH 3.7)-acetonitrile (67:33, v/v, adjusted to pH 5.6 with triethylamine). Detection wavelength of 230 nm for excitation, 280 nm for emission and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed fexofenadine concentration (50 ng/mL) with respect to its peak area and retention time. In addition, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 10-500 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 10 ng/mL, which was sensitive enough for the pharmacokinetic studies of terfenadine. The overall accuracy of the quality control samples ranged from 95.70 to 114.58% for fexofenadine with overall precision (% C.V.) being 3.53-14.39%. The relative mean recovery of fexofenadine for human serum was 90.17%. Stability studies (freeze-thaw, short-term, extracted serum sample and stock solution) showed that fexofenadine was stable during storage, or during the assay procedure in human serum. However, the storage at $-70^{\circ}C$ for 4 weeks showed that fexofenadine was not stable. The peak area and retention time of fexofenadine were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of fexofenadine in human serum samples for the pharmacokinetic studies of orally administered Tafedine tablet (60 mg as terfenadine) at three different laboratories, demonstrating the suitability of the method.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Etodolac in Human (에토돌락 체내동태 연구를 위한 혈청 중 에토돌락의 HPLC 정량법 개발 및 검증)

  • Cho, Hea-Young;Kang, Hyun-Ah;Moon, Jai-Dong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.4
    • /
    • pp.265-271
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of etodolac in human serum was developed, validated, and applied to the pharmacokinetic study of etodolac. Etodolac and internal standard, ibuprofen were extracted from human serum by liquid-liquid extraction with hexane/isopropanol (95:5, v/v) and analyzed on a Luna C18(2) column with the mobile phase of 1% aqueous acetic acid-acetonitrile (4:6, v/v). Detection wavelength of 227 nm and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^3$ factorial design using a fixed etodolac concentration $(1\;{\mu}g/mL)$ with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of $0.05-40\;{\mu}g/mL$ with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 0.05 ${\mu}g/mL$, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 92.00 to 110.00% for etodolac with overall precision (% C.V.) being 1.08-10.11%. The percent recovery for human serum was in the range of 76.73-115.30%. Stability studies showed that etodolac was stable during storage, or during the assay procedure in human serum. The peak area and retention time of etodolac were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of etodolac in human serum samples for the pharmacokinetic studies of orally administered Lodin XL tablet (400 mg as etodolac) at three different laboratories, demonstrating the suitability of the method.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Fenoprofen in Human (페노프로펜 체내동태 연구를 위한 혈청 중 페노프로펜의 HPLC 정량법 개발 및 검증)

  • Cho, Hye-Young;Kang, Hyun-Ah;Kim, Yoon-Gyoon;Sah, Hong-Kee;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.6
    • /
    • pp.423-429
    • /
    • 2005
  • A selective and sensitive reversed-phase HPLC method for the determination of fenoprofen in human serum was developed, validated, and applied to the pharmacokinetic study of fenoprofen calcium. Fenoprofen and internal standard, ketoprofen, were extracted from human serum by liquid-liquid extraction with diethyl ether and analyzed on a Luna C18(2) column with the mobile phase of acetonitrile-3 mM potassium dihydrogen phosphate (32:68, v/v, adjusted to pH 6.6 with phosphoric acid). Detection wavelength of 272 nm and flow rate of 0.25 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed fenoprofen concentration $(2\;{\mu}g/mL)$ with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of $0.05-100\;{\mu}g/mL$ with correlation coefficients greater than 0.999. The lower limit of quantification using 1 mL of serum was $0.05\;{\mu}g/mL$, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 92.27 to 109.20% for fenoprofen with overall precision (% C.V.) being 5.51-11.71 %. The relative mean recovery of fenoprofen for human serum was 81.7%. Stability (freeze-thaw, short and long-term) studies showed that fenoprofen was not stable during storage. But, extracted serum sample and stock solution were allowed to stand at ambient temperature for 12 hr prior to injection without affecting the quantification. The peak area and retention time of fenoprofen were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of fenoprofen in human serum samples for the pharmacokinetic studies of orally administered Fenopron tablet (600 mg as fenoprofen) at three different laboratories, demonstrating the suitability of the method.

Simulation of Rare Earth Elements Removal Behavior in TRU Product Using HSC Chemistry Code (HSC Chemistry 코드를 이용한 TRU 생성물 중의 희토류 원소 제거 거동 모사)

  • Paek, Seungwoo;Lee, Chang Hwa;Yoon, Dalsung;Lee, Sung-Jai
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.207-215
    • /
    • 2020
  • The feasibility of rare earth (RE) removal process via oxidation reactions with UCl3 was investigated using the HSC Chemistry code to reduce the concentrations of RE in transuranic (TRU) products. The composition and thermodynamic data of TRU and RE elements contained in the reference spent fuel were examined. The reactivity was evaluated by calculating equilibrium data considering oxidation reactions with UCl3. Both RE removal rate and TRU recovery rate were evaluated for the two cases, wherein TRU products with different RE concentrations were used. When TRU products were reacted with UCl3, selective oxidation was driven by the difference in the Gibbs free energy of each element. The calculation results imply that the TRU/RE ratio of the final product can be increased by removing RE elements while maintaining the maximum recovery rate of TRU, which is accomplished by controlling the amount of UCl3 injected. Since the results of this study are based on thermodynamic equilibrium data, there are many limitations to apply to the actual process. However, it is expected to be used as an important data for the process design to supply the TRU product of pyroprocessing to SFR's fuel demanding low RE concentrations.