• 제목/요약/키워드: Selected Station Analysis

검색결과 332건 처리시간 0.031초

An Analysis of Wind Field around the Air Quality Monitoring Station in the Urban Area by Using the Envi-met Model (Envi-met 모델을 이용한 도심지역 대기오염측정망 주변의 바람장 분석)

  • Kim, Min-Kyoung;Lee, Hwa Woon;Dou, Woo-Gon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • 제18권9호
    • /
    • pp.941-952
    • /
    • 2009
  • The urban microscale wind field around the air quality monitoring station was investigated in order to check how a building complex influences it. For this study as the high density areas Jwa-dong and Yeonsan-dong monitoring sites in Busan were chosen. As the direction of inflow which is perpendicular to the building of the monitoring station was expected to cause the considerable variation of the wind field, that direction was selected. The model Envi-met was used as the diagnostic numerical model for this study. It is suitable for this investigation because Envi-met has the microscale resolution. After simulating it, on the leeward side around a building complex the decrease of flow velocity and some of vortexes or circulation area were discovered. In addition, on the edge of the top at the building and at the back of the building the upward flow was developed. If the sampling hole of monitoring site were located in this upward flow, it would be under the influence of upward flow from the near street.

Estimation of Drought Rainfall According to Consecutive Duration and Return Period Using Probability Distribution (확률분포에 의한 지속기간 및 빈도별 가뭄우량 추정)

  • Lee, Soon Hyuk;Maeng, Sung Jin;Ryoo, Kyong Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.1103-1106
    • /
    • 2004
  • The objective of this study is to induce the design drought rainfall by the methodology of L-moment including testing homogeneity, independence and outlier of the data of annual minimum monthly rainfall in 57 rainfall stations in Korea in terms of consecutive duration for 1, 2, 4, 6, 9 and 12 months. To select appropriate distribution of the data for annual minimum monthy rainfall by rainfall station, the distribution of generalized extreme value (GEV), generalized logistic (GLO) as well as that of generalized pareto (GPA) are applied and the appropriateness of the applied GEV, GLO, and GPA distribution is judged by L-moment ratio diagram and Kolmogorov-Smirnov (K-S) test. As for the annual minimum monthly rainfall measured by rainfall station and that stimulated by Monte Carlo techniques, the parameters of the appropriately selected GEV and GPA distributions are calculated by the methodology of L-moment and the design drought rainfall is induced. Through the comparative analysis of design drought rainfall induced by GEV and GPA distribution by rainfall station, the optimal design drought rainfall by rainfall station is provided.

  • PDF

A Systems Engineering Approach to Ex-Vessel Cooling Strategy for APR1400 under Extended Station Blackout Conditions

  • Saja Rababah;Aya Diab
    • Journal of the Korean Society of Systems Engineering
    • /
    • 제19권2호
    • /
    • pp.32-45
    • /
    • 2023
  • Implementing Severe Accident Management (SAM) strategies is crucial for enhancing a nuclear power plant's resilience and safety against severe accidents conditions represented in the analysis of Station Blackout (SBO) event. Among these critical approaches, the In-Vessel Retention (IVR) through External Reactor Vessel Cooling (IVR-ERVC) strategy plays a key role in preventing vessel failure. This work is designed to evaluate the efficacy of the IVR strategy for a high-power density reactor APR1400. The APR1400's plant is represented and simulated under steady-state and transient conditions for a station blackout (SBO) accident scenario using the computer code, ASYST. The APR1400's thermal-hydraulic response is analyzed to assess its performance as it progresses toward a severe accident scenario during an extended SBO. The effectiveness of emergency operating procedures (EOPs) and severe accident management guidelines (SAMGs) are systematically examined to assess their ability to mitigate the accident. A group of associated key phenomena selected based on Phenomenon Identification and Ranking Tables (PIRT) and uncertain parameters are identified accordingly and then propagated within DAKOTA Uncertainty Quantification (UQ) framework until a statistically representative sample is obtained and hence determine the uncertainty bands of key system parameters. The Systems Engineering methodology is applied to direct the progression of work, ensuring systematic and efficient execution.

Energy saving control system of wireless base station utilizing natural air-conditioning (자연공조를 활용한 무선기지국 Energy절감 제어시스템)

  • Ryu, Gu-Hwan;Kwon, Chang-Hee
    • Journal of Digital Convergence
    • /
    • 제17권10호
    • /
    • pp.223-232
    • /
    • 2019
  • With the development of the information communication industry, the size of the communication device has been reduced to a system that generates a large amount of heat. Therefore, since the amount of heat generated by the wireless equipment is large in the wireless base station, the energy consumption is continuously consumed and the failure of the wireless base station may occur. Therefore, in this study, The study was analyzed. As a research method, we performed base station with a lot of calorific value and electric charge. We selected 25 base stations and obtained data for two weeks. To ensure reliability, the room temperature was kept constant at $27^{\circ}C$, and the control system was installed and equiped for two weeks to obtain the date analysis. In order to calculate the test results in the study method, the instrument was used with a computer, a digital thermometer, and dust measurement. For the date analysis, we conducted a research study on 25 wireless basestations before and after the installation of Control Sysetm.

Air Pollution Tolerance and Heavy Metal Accumulation of Selected Tree Species at Swamp Forest Research Station, Onne, Rivers State

  • Rosemary Egodi Ubaekwe;Victoria Amarachi Okpara;Uzoma Darlington Chima
    • Journal of Forest and Environmental Science
    • /
    • 제40권3호
    • /
    • pp.227-240
    • /
    • 2024
  • Trees improve air quality through the accumulation of air pollutants in their leaves; however, the responses of different tree species to air pollution varies. Hence, this study evaluated the responses to air pollution of selected tree species in the Swamp Forest Research Station, Onne. Ten tree species (Cola pachycarpa, Khaya grandifoliolia, Irvingia gabonensis, Garcinia kola, Chrysophyllum albidum, Treculia africana, Dacryodes edulis, Tectonia grandis, Gmelina aborea, and Nauclea diderrichii) were selected based on their abundance in the area. Leaves were collected from all sides in 3 replicates for each tree species. Laboratory analysis was carried out using standard procedures. Portable Multi Gas Detector was used to determine the concentrations of air pollutants. One-way analysis of variance was employed to test for significant difference (p≤0.05) in biochemical parameters among the tree species while Pearson's correlation was utilized to determine the level of association between different biochemical parameters and APTI; heavy metals and APTI. Results showed high concentration of PM10, CO, moderate concentration of NO2, PM2.5, and VOC, and low concentration of ground O3. Heavy metals - Cadmium, Mercury, Lead, Nickel and Copper were all present in the tree species at varying rates. There were significant differences in the biochemical parameters and APTI values. C. pachycarpa exhibited the highest APTI value (89.88), while D. edulis had the lowest APTI value (8.24). C. pachycarpa, K. grandifoliolia, C. albidum, G. kola, T. africana, and N. diderrichii were identified as tolerant tree species to air pollution. G. aborea, T. grandis, and I. gabonensis were considered intermediate tolerant species, while D. edulis was the only tree species sensitive to air pollution. Ascorbic Acid, Chlorophyll, Hg and Ni had positive correlations with APTI; Cd and Cu had negative association with APTI at the 0.05 significance level. C. pachycarpa, T. africana, K. grandifoliolia, C. albidum, N. diderrichii and G. kola, are recommended for planting in pollution-prone areas.

Estimation of Additive and Dominance Genetic Variances in Line Breeding Swine

  • Ishida, T.;Kuroki, T.;Harada, H.;Fukuhara, R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2001
  • Additive and dominance genetic variances were estimated for purebred Landrace selected with line breeding from 1989 to 1995 at Miyazaki Livestock Experiment Station, Kawaminami Branch. Ten body measurements, two reproductive traits and fifteen carcass traits were analyzed with single-trait mixed model analysis. The estimates of narrow-sense heritabilities by additive model were in the range of 0.07 to 0.46 for body measurements, 0.05 to 0.14 for reproductive traits, and 0.05 to 0.68 for carcass traits. The additive model tended to slightly overestimate the narrow-sense heritabilities as compared to the additive and dominance model. The proportion of the dominance variance to total genetic variance ranged from 0.11 to 0.91 for body measurements, 0.00 to 0.65 for reproductive traits, and 0.00 to 0.86 for carcass traits. Large differences among traits were found in the ratio of dominance to total genetic variance. These results suggested that dominance effect would affect the expression of all ten body measurements, one reproductive trait, and nine carcass traits. It is justified to consider the dominance effects in genetic evaluation of the selected lines for those traits.

Application of WMS Model for Runoff Analysis of Miho Stream Basin (미호천 유역의 유출해석을 위한 WMS 모형의 적용)

  • Ahn, Sang-Jin;Lee, Moo-Kyeong;Jun, Kye-Won;Yeon, In-Sung
    • Journal of Korea Water Resources Association
    • /
    • 제37권11호
    • /
    • pp.929-938
    • /
    • 2004
  • In this study, Miho stream basin(Seokhwa water level gauging station) In Geum river, Flood control main station of Geum River Flood Control Office, is selected. Hydrologic topographical informations are calculated using WMS which is hydrologic analysis software coupled with GIS Method, and flood analysis is accomplished by HEC-1 included In WMS. To calculate the effective rainfall CN values of SCS are used. Clark, Snyder and SCS methods are selected respectively to derive unit hydrograph. This study shows the applicability of GIS techniques to runoff simulation in ungauged basin by comparing with actual measured flood hydrograph. As a results, Snyder(Tulsa) method and Clark (Herby) method is suitable to Miho stream basin. But Snyder(Tulsa) method is suitable more than Clark(Herby) method. And according to the degree of urbanization, the peak discharge has increased and the peak time has tended to decrease.

Identification of hydrogen flammability in steam generator compartment of OPR1000 using MELCOR and CFX codes

  • Jeon, Joongoo;Kim, Yeon Soo;Choi, Wonjun;Kim, Sung Joong
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1939-1950
    • /
    • 2019
  • The MELCOR code useful for a plant-specific hydrogen risk analysis has inevitable limitations in prediction of a turbulent flow of a hydrogen mixture. To investigate the accuracy of the hydrogen risk analysis by the MELCOR code, results for the turbulent gas behavior at pipe rupture accident were compared with CFX results which were verified by the American National Standard Institute (ANSI) model. The postulated accident scenario was selected to be surge line failure induced by station blackout of an Optimized Power Reactor 1000 MWe (OPR1000). When the surge line failure occurred, the flow out of the surgeline was strongly turbulent, from which the MELCOR code predicted that a substantial amount of hydrogen could be released. Nevertheless, the results indicated nonflammable mixtures owing to the high steam concentration released before the failure. On the other hand, the CFX code solving the three-dimensional fluid dynamics by incorporating the turbulence closure model predicted that the flammable area continuously existed at the jet interface even in the rising hydrogen mixtures. In conclusion, this study confirmed that the MELCOR code, which has limitations in turbulence analysis, could underestimate the existence of local combustible gas at pipe rupture accident. This clear comparison between two codes can contribute to establishing a guideline for computational hydrogen risk analysis.

시스템다이내믹스를 활용한 인력 수급 계획 모형 설계

  • Jeong, Jae-Rim;Jeon, So-Yeon;Gwak, Mi-Ae;Yeon, Seung-Jun
    • Proceedings of the Korean System Dynamics Society
    • /
    • 한국시스템다이내믹스학회 2007년도 춘계학술대회 발표논문집
    • /
    • pp.113-129
    • /
    • 2007
  • Due to criminal aspects spreading nation wide, their intelligence level increasing and becoming digitalized, the citizens' interest in and desire for crime security have increased. Until now, the preceding researches have been focused on finding the specific variables that have direct effects on the demand for police manpower through regression analysis and attempted to predict number of needs. However, there have never been any researches producing the accurate number of demands for crimes and human resources needed for each work load. Therefore, this research have analyzed each police station functions by interviewing the persons in charge and selected the main duty for each functions. From this, by using the method of system dynamics, this research was able to predict the standard number of manpower needed for each police station functions. Also, by making a model for each 235 police stations, the best efficient employment plan for police stations and district agencies have been further discussed based on the computer simulation results.

  • PDF

Selection of Measuring Sensors for Reactor Vessel Internals Comprehensive Vibration Assessment Program in Advanced Power Reactor 1400 (APR1400 원자로 내부구조물 종합진동평가 측정센서 선정)

  • Ko, Do-Young;Lee, Jae-Gon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.433-438
    • /
    • 2010
  • Reactor vessel internals comprehensive vibration assessment program(RVI CVAP) is one of the necessary tests to ensure the safety of nuclear power plants. RVI CVAP of U.S. Nuclear Regulatory Commission Regulatory Guide 1.20(U.S. NRC R.G. 1.20) consists of the analysis, measurement, and inspection. One of the core technologies of the measurement program for RVI CVAP is to select suitable sensors. We analyzed RVI design data of Palo Verde nuclear generating station(U.S.) and Yonggwang nuclear generating station(Korea) and investigated measuring sensors used in both of them; moreover, we investigated sensors used for measurement of RVI CVAP for the last 20 years throughout the world. Based on these results, we selected the most suitable sensors for RVI CVAP in Advanced Power Reactor 1400(APR1400).

  • PDF