• 제목/요약/키워드: Seismic performance test

검색결과 886건 처리시간 0.027초

원자력 전기기기 부품의 내진성능 확인을 위한 진동대 실험 (Shaking Table Test to Verify the Seismic Performance of Nuclear Electric Components)

  • 장성진;전법규;박동욱;김성완
    • 한국지진공학회논문집
    • /
    • 제28권3호
    • /
    • pp.141-147
    • /
    • 2024
  • Earthquakes of magnitude 3.0 or greater occur in Korea about 10 times on average yearly, and the number of earthquakes occurring in Korea is increasing. As many earthquakes have recently occurred, interest in the safety of nuclear power plants has increased. Nuclear power plants are equipped with many cabinet-type control facilities to regulate safety facilities, and function maintenance is required during an earthquake. The seismic performance of the cabinet is divided into structural and functional performances. Structural performance can be secured during the design procedure. Functional performance depends on the vibration performance of the component. Therefore, it is necessary to confirm the seismic performance of the components. Generally, seismic performance is confirmed through seismic simulation tests. When checking seismic performance through seismic simulation tests, it is difficult to determine the effect of frequency and maximum acceleration on an element. In this paper, shaking table tests were performed using various frequencies and various maximum accelerations. The seismic performance characteristics of the functions of electrical equipment components were confirmed through tests.

Performance Evaluation of Seismic Stopper using Structural Analysis and AC156 Test Method

  • Ryu, Hyun-su
    • 해양환경안전학회지
    • /
    • 제26권3호
    • /
    • pp.277-285
    • /
    • 2020
  • Recently, studies have been actively conducted on seismic design and improvement of the seismic performance of bridges, buildings, factories, and plants. In particular, heavy items that are being manufactured or waiting to be shipped from factories (such as generators, engines, and boilers) must be equipped with seismic stoppers to prevent them from moving or falling during an earthquake. Seismic stoppers should be suitably determined by the size and weight of these heavy items; however, they have no general design standard. In this study, structural analyses and seismic tests were conducted to evaluate the performance of newly designed seismic stoppers. Structural analysis was performed on three stopper models to estimate the external load at which the yield stress of the material was not exceeded. Based on the analysis results, a seismic test of the stopper was carried out in accordance with the AC156 test method. Finally, product specifications for all three seismic stopper models were determined and their static/dynamic load performance was evaluated.

석고 패널이 부착된 천장 시스템의 내진성능 평가를 위한 3축 진동실험 (Triaxial Shake Table Test about Seismic Performance of Ceiling System with Gypsum Panels)

  • 박해용;전법규;김재봉;김민욱
    • 대한건축학회논문집:구조계
    • /
    • 제35권10호
    • /
    • pp.143-153
    • /
    • 2019
  • In this study, a full scale 3-axes shake table test for M-bar and T-bar type ceilings commonly used in the country was conducted. Through damage inspection during the test, seismic performance of ceilings according to variables, such as clearance between wall mold and ceiling as well as existence of facilities, was evaluated. A test frame consisted of square hollow section members was used for the shake table test. The experimental method was performed as a fragility test using required response spectrum described in ICC-ES AC156. In the case of architectural nonstructural component that contain ceilings, it mainly is evaluated the performance by post-test visual inspection. For the evaluation of seismic performance of ceilings, this study classified and defined damaged items for targeted ceiling system referring to illustrative damage according to nonstructural performance levels accordance with ASCE 41 and previous studies. And proposed illustrative damage items classification was utilized to compare the degree of the damage according to experimental variables. The experiment results confirmed that differences in boundary conditions due to the clearance at wall mold and the installation of facilities had a significant effect on the seismic performance of the ceiling.

A Study on the Bending and Seismic Performance of High Performance Cold Forming Composite Beam

  • Choi, Young Han;Kim, Sung Bae;Hong, Hyung Ju;Kim, Sang Seup
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1772-1783
    • /
    • 2018
  • Nowadays, the researches about composite structure system are being implemented in various fields, and many steel structures are designed based on that. In this study, the bending and seismic performance of the newly developed high-performance cold forming composite beam are evaluated by several experiments. As a result of the bending performance test, the bending moment of beam was increased stably depending on the depth and plate thickness of beam, and it is considered that the bending moment can be evaluated by the equation of a composite beam design. As a result of the seismic performance test, it was verified that sufficient seismic performance was obtained despite the increase of a negative moment rebar and depth of beam. In addition, the nominal bending moment has obtained the strength above the plastic bending moment, and also the plastic rotation angle has satisfied the requirement of composite intermediate moment frame.

Seismic behavior of simplified electrical cabinet model considering cast-in-place anchor in uncracked and cracked concretes

  • Bub-Gyu Jeon;Sung-Wan Kim;Sung-Jin Chang;Dong-Uk Park;Hong-Pyo Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4252-4265
    • /
    • 2023
  • In the case of nuclear power plants near end of their design life, a reassessment of the performance of safetyrelated equipment may be necessary to determine whether to shut down or extend the operation of the power plant. Therefore, it is necessary to evaluate the level of performance decline due to degradation. Electrical cabinets, including MCC and switchgear, are representative safety-related equipment. Several studies have assessed the degradation and seismic performance of nuclear power plant equipment. Most of those researches are limited to individual components due to the size of safety-related equipment and test equipment. However, only a few studies assessed the degradation performance of electrical cabinets. The equipment of various nuclear power plants is anchored to concrete foundations, and crack in concrete foundations is one of the most representative of degradation that could be visually confirmed. However, it is difficult to find a study for analysis through testing the effect of cracks in concrete foundations on the response of electrical cabinet internal equipment fixed by anchors. In this study, using a simple cabinet model considering cast-in-place anchor in uncracked and cracked concretes, a tri-axial shaking table tests were performed and the seismic behavior were observed.

원형 실물 철근 콘크리트 교각의 철근 상세에 따른 내진성능 평가 (Seismic Performance Evaluation of Circular RC Bridge Piers with Various Steel Type)

  • 정영수;박진영;이재훈;조대연;이대형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.965-970
    • /
    • 2001
  • The object of this research is to evaluate the seismic performance of existing RC bridge piers that were constructed before the adoption of the seismic design provision of Korea Bridge Design Specification in 1992. In this research, adopted test parameters were limited ductile design or non-seismic design, aspect ratio, confinement steel type, loading pattern, lap-spliced ratio for longitudinal reinforcement. This study has been performed to verify the effect of test parameter by quasi-static test. Quasi-static test has been done to investigate the physical seismic performance of RC bridge piers, such as lateral force-displacement hysteretic curve, envelope curve etc. It has been observed that seismic performance of lap-spliced test specimen, non-seismically designed specimens, was significantly reduced.

  • PDF

내진설계 되지 않은 공동주택의 진동대 실험에 의한 내진성능 평가 (Shaking Table Test for Seismic Performance Evaluation of Non-Seismic Designed Wall-Type Apartment)

  • 정란;이정우;박태원
    • 콘크리트학회논문집
    • /
    • 제18권6호
    • /
    • pp.721-728
    • /
    • 2006
  • 지진은 구조물에 막대한 피해를 발생시키는 것으로 보고되고 있으나, 우리나라에 내진설계규정이 도입되기 전인 1988년 이전에 설계된 건물은 이에 대한 대책이 없다. 특히 공동주택의 경우 지진저항요소가 없는 구조물이 다수 있는 것으로 조사되었다. 이러한 구조물에 대하여 내진성능의 정도를 파악하고, 성능지수가 부족한 구조물에 대해서는 적절한 보강이 이루어져야 할 것이다. 본 연구에서는 이전의 연구에서 범용 구조해석 프로그램인 MIDAS를 이용하여 모델 구조물의 내진성능을 평가하여 얻어진 내진성능의 부족함을 기초로 5층 규모의 철근콘크리트 벽식 구조물에 상사법칙을 적용하고, 진동대 실험을 수행하여 국내외 규준에 의한 모델 구조물의 내진성능을 평가하였다. 진동대 실험의 경우 실험의 공간적 제약으로 인하여 원형 구조물에 대한 실험을 할 수 없어, 구조물의 원형크기를 상사법칙에 의하여 필요한 규모로 축소하여 제작하였다. 성능수준을 평가해 본 결과 내진설계가 수행되지 않은 구조물은 PGA 등급 0.2g의 지진에 대하여 사용한계수준의 내진성능을 나타내었으며 허용층간변위를 평가해 본 결과 0.2g의 지진등급까지만 허용한계수준의 층간변위를 나타내어 내진성능에 대한 보강이 필요할 것으로 판단되었다.

Experimental study on seismic performance of reinforced concrete frames retrofitted with eccentric buckling-restrained braces (BRBs)

  • Yang, Yong;Liu, Ruyue;Xue, Yicong;Li, Hui
    • Earthquakes and Structures
    • /
    • 제12권1호
    • /
    • pp.79-89
    • /
    • 2017
  • As a new type of energy dissipation component with excellent mechanical performance, the Buckling-Retrained Braces (BRBs) were gradually applied in retrofitting and improving seismic performance of reinforced concrete structures in China. In order to investigate the seismic performance of reinforced concrete structures retrofitted with BRBs, quasi-static test of two single-bay and 3-story reinforced concrete frames specimens was conducted and introduced in this paper. Two 1/2 scaled specimens were designed to reflect real prototype structure. For comparison, one control specimen was designed without BRBs, and the other specimen was retrofitted with BRBs. And particularly, for the specimen retrofitted with BRBs, the BRBs were eccentric layout instead of usually concentric or x-shaped layout, aiming to be more suitable for large-span frames. In the test, the failure mode, carrying capacity, deformability, ductility and energy dissipation ability of both two specimens were investigated. Based on the test results of the measured hysterical curves, skeleton curves, the seismic performances such as bearing capacity, plastic deformability, energy dissipation ability and ductility of two specimens were fully studied. And from the test results, it was indicated that the specimen retrofitted with BRBs showed much better seismic performance than the control specimen without BRBs, and the BRBs could effectively improve the seismic performance of the reinforced concrete frame. For the specimen retrofitted with BRBs, the BRBs firstly yielded before the beam-ends and the column-ends, and an expected yielding process or yielding mechanism as well as good seismic performance was obtained. For the specimens without BRBs, though the beam-ends yielded prior to the column-ends, the seismic performance was much poor than that of the specimen with BRBs.

EPFT 강관기둥으로 보강된 콘크리트 기둥의 내진성능실험 (Seismic Performance Test of Concrete Column Reinforced with EPFT)

  • 김유성;이준호;김기철
    • 한국공간구조학회논문집
    • /
    • 제22권3호
    • /
    • pp.73-80
    • /
    • 2022
  • Unlike the CFT retrofit method, The EPFT retrofit method, which fills the steel tube with engineering plastic, does not require a separate concrete forming work and is a lightweight seismic Retrofit Method. In this study, an prototype model of the EPFT was proposed, and to analyze the seismic performance, an independent specimens and a reinforced concrete column were fabricated to conduct a seismic performance test. As a result of loading test of the independent specimens, the strength was increased compared to the steel tube column without internal filling, and the ductility ratio did not significantly increase due to the falling off of the weld. As a result of loading test of the concrete reinforcement specimen, the strength, ductility ratio, and energy dissipation were increased, and the number of cracks by loading step decreased compared to the non-reinforced specimen.

Shake table test of Y-shaped eccentrically braced frames fabricated with high-strength steel

  • Lian, Ming;Su, Mingzhou
    • Earthquakes and Structures
    • /
    • 제12권5호
    • /
    • pp.501-513
    • /
    • 2017
  • To investigate the seismic performance of Y-shaped eccentrically braced frames fabricated with high-strength steel (Y-HSS-EBFs), a shake table test of a 1:2 scaled three-story Y-HSS-EBF specimen was performed. The input wave for the shake table test was generated by the ground motions of El Centro, Taft, and Lanzhou waves. The dynamic properties, acceleration, displacement, and strain responses were obtained from the test specimen and compared with previous test results. In addition, a finite element model of the test specimen was established using the SAP2000 software. Results from the numerical analysis were compared with the test specimen results. During the shake table test, the specimen exhibited sufficient overall structural stiffness and safety but suffered some localized damage. The lateral stiffness of the structure degenerated during the high seismic intensity earthquake. The maximum elastic and elastoplastic interstory drift of the test specimen for different peak ground accelerations were 1/872 and 1/71, respectively. During the high seismic intensity earthquake, the links of the test specimen entered the plastic stage to dissipate the earthquake energy, while other structural members remained in the elastic stage. The Y-HSS-EBF is a safe, dual system with reliable seismic performance. The numerical analysis results were in useful agreement with the test results. This finding indicated that the finite element model in SAP2000 provided a very accurate prediction of the Y-HSS-EBF structure's behavior during the seismic loadings.