• 제목/요약/키워드: Seismic performance test

검색결과 885건 처리시간 0.034초

스틸하우스 전단벽체의 내진성능평가 (Evaluation of Seismic Performance on Shear Walls in Steel House)

  • 이재석;이승은;홍건호;김원기
    • 한국지진공학회논문집
    • /
    • 제6권6호
    • /
    • pp.65-72
    • /
    • 2002
  • 최근의 건축물 내진 설계 추세에 맞추어, 박판의 냉간성형강으로 제작되는 스틸하우스 전단벽체의 내진 성능을 평가하였다. 시험체는 브레이싱의 종류에 따라 변수를 두었다. 반복가력의 결과로는 에너지소산 능력을 살펴보았는데, 브레이싱 부재로 형강을 사용한 시험체가 판재를 사용한 시험체 보다 우수하였다. 또한, 유사동적실험을 통해서는 면재를 사용한 전단벽체 보다. 스틸하우스 전단벽체 중 하나인 X-브레이싱 형태와 유사한 X2SPCH의 내진성능이 비교적 우수함이 판명되었다.

RC 경계골조를 설치한 신축 비보강 조적벽체의 내진성능 평가 (Seismic Performance Evaluation of Unreinforced Masonry Walls with Additional Boundary RC Frames)

  • 유영찬;김민선;이현지
    • 대한건축학회논문집:구조계
    • /
    • 제34권11호
    • /
    • pp.27-35
    • /
    • 2018
  • The purpose of this study is to examine the effects of boundary RC frame(composed of one tie-beam and two tie-columns) on seismic performance of unreinforced masonry walls to suggest alternative way for seismic design of unreinforced masonry wall structures. Two test specimens are prepared, one is a typical unreinforced masonry wall and another is alternative unreinforced masonry wall with additional boundary RC frame. The structural experiments were carried out to evaluate the difference of seismic resistance performance between two test specimens with or without the boundary RC frames. From the test results, it was found that the failure mode of unreinforced masonry wall fundamentally changed from 'brittle' to 'ductile' by the installing of boundary RC frames. And, the maximum load and energy dissipation capacity of the test specimen with boundary RC frame was increased about 1.6~1.7 and 2~3 times respectively compared with a typical unreinforced masonry wall specimen.

개착식 전력구의 내진성능 평가 및 내진 안전성 검증 (Study on Seismic Performance Evaluation and Verification of Seismic Safety for Power Cable Tunnels)

  • 황경민;전낙현;정길영;박경성
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.439-445
    • /
    • 2020
  • 본 논문에서는 내진설계가 고려되어 있지 않은 전력구를 포함한 기설 개착식 전력구 100개소를 대상으로, 정부의 요구수준(내진 특등급, 0.22 g)을 만족하는지 확인하기 위하여 내진성능 평가를 수행하였다. 내진성능 평가 결과, 대상 전력구들은 대부분 0.3-1 g의 내진성능을 보유하고 있는 것으로 나타나, 내진 특등급 수준을 만족하였으며 내진안전성을 확보하고 있는 것으로 나타났다. 한편 응답변위법에 의한 전력구의 내진성능 평가 방법 및 결과에 대한 타당성을 확인하고, 전력구의 내진 안전성을 검증하기 위한 지진응답 해석 및 구조실험을 수행하였다. 그 결과 0.22 g 수준의 지진 하에서 응답변위법에 의한 상대변위는 지진응답 해석 결과보다 보수적이었으며, 실규모 구조실험에 의한 하중-변위 곡선 및 응답수정계수 산정 결과를 통해 전력구의 내진 안전성을 확인할 수 있었다.

이중 슬립마찰면을 이용한 면진장치의 면진성능평가 (Seismic Performance Evaluation of Seismic Isolation Device with Double Slip Friction Surface)

  • 손수원;권정호;김정곤;정용규;황은동
    • 한국재난정보학회 논문집
    • /
    • 제16권4호
    • /
    • pp.712-722
    • /
    • 2020
  • 연구목적: 최근 국내 규모 5.0이상의 지진으로 인한 피해 발생이 증가하고 있다. 지진이 발생하면 구조물 이외에도 내부설비, 전력기기 등에 피해를 주게 된다. 이에 본 논문에서는 지진으로 인한 배전반과 같은 전기기기의 피해를 저감시킬 수 있는 이중 슬립마찰면이 있는 면진장치를 개발하였으며, 이에 대한 면진성능을 평가하였다. 연구방법: 면진성능을 평가하기 위해 진동대 시험을 수행하였으며, 면진장치 유무에 따른 성능비교를 수행하였다. 다양한 주파수와 가속도 수준에 대한 응답가속도 및 변위를 비교하여 면진장치의 감쇠효과를 분석하였다. 연구결과: 시험결과, 면진장치가 설치되어 있는 경우가 면진장치가 설치되어 있지 않은 경우보다 가속도 증폭이 최대 42% 작았다. 이는 면진장치의 이중슬립마찰면 사이에서 발생한 변위가 지진에너지를 소산하는 역할을 하여 증폭에너지가 감소된 것으로 판단된다. 결론: 이중 슬립마찰면을 적용한 면진장치는 약진보다는 강진에서 지진감쇠효과가 더 컸으며, 주파수가 클수록 지진감쇠효과가 더 좋았다. 따라서, 배전반과 같은 전기기기에 적용하여 지진에너지를 감쇠하는 작용을 할 수 있을 것으로 판단된다.

플랜트 설비 지지용 대안 강구조 시스템의 내진성능 (Seismic Performance of Alternative Steel Structural Systems for an Equipment-Supporting Plant Structure)

  • 곽병훈;안숙진;박지훈
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.13-24
    • /
    • 2023
  • In this study, alternative seismic force-resisting systems for plant structure supporting equipment were designed, and the seismic performance thereof was compared using nonlinear dynamic analysis. One alternative seismic force-resisting system was designed per the requirement for ordinary moment-resisting and concentrically braced frames but with a reduced base shear. The other seismic force-resisting system was designed by accommodating seismic details of intermediate and unique moment-resisting frames and special concentrically braced frames. Different plastic hinge models were applied to ordinary and ductile systems based on the validation using existing test results. The control model obtained by code-based flexible design and/or reduction of base shear did not satisfy the seismic performance objectives, but the alternative structural system did by strengthened panel zones and a reduced effective buckling length. The seismic force to equipment calculated from the nonlinear dynamic analysis was significantly lower than the equivalent static force of KDS 41 17 00. The comparison of design alternatives showed that the seismic performance required for a plant structure could be secured economically by using performance-based design and alternative seismic-force resisting systems adopting minimally modified seismic details.

Seismic performance of precast assembled bridge piers with hybrid connection

  • Shuang, Zou;Heisha, Wenliuhan;Yanhui, Liu;Zhipeng, Zhai;Chongbin, Zhang
    • Structural Engineering and Mechanics
    • /
    • 제85권3호
    • /
    • pp.407-417
    • /
    • 2023
  • Precast assembled bridge piers with hybrid connection (PASP) use both tendons and socket connections. To study the seismic performance of PASP, a full-scale in-situ test was performed based on an actual bridge project. The elastic-plastic fiber model of PASP was established using finite element software, and numerical analyses were performed to study the influence of prestress degree and socket depth on the PASP seismic performance. The results show that the typical failure mode of PASP under horizontal load is bending failure dominated by concrete cracking at the joint between the column and cushion cap. The cracking of the pier concrete and opening of joints depend on the prestress degree and socket depth. The prestressing tendons and socket connection can provide enough ductility, strength, restoration capability, and bending strength under small horizontal displacements. Although the bearing capacity and post yield stiffness of the pier can be improved to some extent by increasing the prestressing force, ductility is reduced, and residual deformation is increased. Overall, there are reasonable minimum socket depths to ensure the reliability of the socket connection.

휨-전단 복합 거동 원형 RC교각의 내진성능 평가 (Seismic Performance Evaluation of Circular RC Bridge Piers with Shear-Flexure Behavior)

  • 김병석;곽임종;조창백;조정래
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.337-344
    • /
    • 2001
  • Some as-built drawings in national roadway bridges in Korea were examined. There are many bridge piers, whose aspect ratios are in the vicinity of 2.5. These columns are expected to do shear-flexure behaviour and have large scale effect between full and reduced scale model. In the study, full and 1/2 scale model tests on the shear-flexure behaviour columns were carried out. The seismic performance of existing bridge piers without seismic details were examined by Quasi Static Test

  • PDF

천장 브래킷형 모듈러 시스템의 접합부 내진 성능과 설계 프로세스 (Seismic Performance and Design Process of a Ceiling Bracket-Typed Modular Connection)

  • 이승재;강창훈;박재성;곽의신;손수덕
    • 한국공간구조학회논문집
    • /
    • 제20권3호
    • /
    • pp.27-34
    • /
    • 2020
  • This paper examines the seismic performance and structural design of the ceiling bracket-type modular connection. The bracket-type system reduces the cross-sectional area loss of members and combines units using fitting steel plate, and it has been developed to be fit for medium-story and higher-story buildings. In particular, this study conducted the cyclic loading test for the performance of the C-type and L-type brackets, and compared the results. The test results were also compared with the commercial FEA program. In addition, the structural design process for the bracket-type modular connection was presented. The two connections, proposed as a result of the test results, were all found to secure the seismic performance level of the special moment steel frame. In the case of initial stiffness, the L-type bracket connection was found to be great, but in the case of the maximum moment or fully plastic moment, it was different depending on the loading direction.

커튼월의 내진성능 향상을 위한 시제품 개발 및 실험 (Prototype Development and Experimentation to Improve the Seismic Performance of Curtain walls)

  • 민병준;원정훈;전진우;강현욱
    • 한국건설관리학회논문집
    • /
    • 제24권4호
    • /
    • pp.14-24
    • /
    • 2023
  • 본 연구의 목적은 커튼월의 내진성능을 향상시킨 커튼월 제품을 개발하고, 층간변위시험을 실시하여 내진성능을 검증하는 것이다. 이를 위하여 (재)한국건설생활환경시험연구원의 옥외실증센터에서 커튼월 시험체를 2개층 이상으로 제작하고 지진하중과 유사한 변위량을 유발한 후 커튼월의 파손상태를 확인하였다. 1차 시험을 실시한 결과, 내진등급(특) 기준에서는 커튼월 시제품의 프레임과 유리 파손이 발생되지 않았으나, 내진등급(I)과 내진등급(II ) 기준에서는 Weather Sealant가 일부 파손되었다. 그리고 AAMA 501.6(동적내진시험)에서 정한 최대 층간변위량 150mm를 가압하였을 때 유리가 파손되는 현상이 발생되었다. 2차 시험을 실시한 결과, 내진등급(특), 내진등급(I), 내진등급(II), AAMA 501.6에서 유리가 파손되는 문제가 발생되지 않았다. 따라서, 본 커튼월 시제품의 내진성능 시험을 실시한 (재)한국건설생활환경시험연구원에서 2016년 9월 경주 5.8 규모와 2017년 11월 포항 5.4 규모의 지진에도 커튼월 프레임과 프레임 간의 탈락, Weather Sealant의 찢어짐 그리고 유리가 파손되는 피해가 없을 것으로 사료된다는 판단을 받았다.

Influence of design modification of control rod assembly for Prototype Generation IV Sodium-cooled Fast Reactor on drop performance

  • Son, Jin Gwan;Lee, Jae Han;Kim, Hoe Woong;Kim, Sung Kyun;Kim, Jong Bum
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.922-929
    • /
    • 2019
  • This paper presents the drop performance test of the control rod assembly which is one of the main components strongly related to the safety of the prototype generation IV sodium-cooled fast reactor. To investigate the drop performance, a real-sized control rod assembly that was recently modified based on the drop analysis results was newly fabricated, and several free drop tests under different flow rate conditions were carried out. Then the results were compared with those obtained from the previous tests conducted on the conceptually designed control rod assembly to demonstrate the improvement in performance. Moreover, the drop performance tests under several types and magnitudes of seismic loadings were also conducted to investigate the effect of the seismic loading on the drop performance of the modified control rod assembly. The results showed that the effects of the type and magnitude of the seismic loading on the drop performance of the modified control rod assembly were not significant. Also, the drop time requirement was successfully satisfied, even under the seismic loading conditions.