• 제목/요약/키워드: Seismic mass

검색결과 501건 처리시간 0.022초

Vertical seismic response analysis of straight girder bridges considering effects of support structures

  • Wang, Tong;Li, Hongjing;Ge, Yaojun
    • Earthquakes and Structures
    • /
    • 제8권6호
    • /
    • pp.1481-1497
    • /
    • 2015
  • Vertical earthquake ground motion may magnify vertical dynamic responses of structures, and thus cause serious damage to bridges. As main support structures, piers and bearings play an important role in vertical seismic response analysis of girder bridges. In this study, the pier and bearing are simplified as a vertical series spring system without mass. Then, based on the assumption of small displacement, the equation of motion governing the simply-supported straight girder bridge under vertical ground motion is established including effects of vertical deformation of support structures. Considering boundary conditions, the differential quadrature method (DQM) is applied to discretize the above equation of motion into a MDOF (multi-degree-of-freedom) system. Then seismic responses of this MDOF system are calculated by a step-by-step integration method. Effects of support structures on vertical dynamic responses of girder bridges are studied under different vertical strong earthquake motions. Results indicate that support structures may remarkably increase or decrease vertical seismic responses of girder bridges. So it is of great importance to consider effects of support structures in structural seismic design of girder bridges in near-fault region. Finally, optimization of support structures to resist vertical strong earthquake motions is discussed.

3차원 탄성파 토모그래피의 현장 적용 (II);댐 예정지에서의 3차원 토모그래피 적용 사례 (A Field Application of 3D Seismic Traveltime Tomography (II);Application of 3D Seismic Traveltime Tomography to a dam-planned area)

  • 문윤섭;하희상;고광범;김지수
    • 터널과지하공간
    • /
    • 제18권4호
    • /
    • pp.263-271
    • /
    • 2008
  • 3차원 탄성파 토모그래피 알고리즘으로서 Fast Marching Method와 프레넬 볼륨에 기반한 알고리즘의 현장 적용성을 검토하고자 댐 건설 예정부지에 3차원 토모그래피 탐사를 수행하였다. 재구성된 3차원 탄성파 속도 입방체는 실제 지층 구조와 매우 유사한 속도분포를 보였다. 또한 시추 시료의 RMR 자료와 탄성파 속도간 직접 상관관계 분석을 수행하여 얻어진 RMR 입방체는 미 시추 구간 대한 신뢰도 높은 암반분류 정보를 제공하는 것을 확인하였다. 3차원 탄성파 토모그래피의 현장 적용에 대한 충분한 가능성을 확인하였으며 향후 초동 주시 계산 및 역해 알고리즘의 개선으로 보다 경제적으로 향상된 탐사를 수행할 수 있을 것으로 기대한다.

Fundamental aspects on the seismic vulnerability of ancient masonry towers and retrofitting techniques

  • Preciado, Adolfo;Bartoli, Gianni;Budelmann, Harald
    • Earthquakes and Structures
    • /
    • 제9권2호
    • /
    • pp.339-352
    • /
    • 2015
  • Ancient masonry towers constitute a relevant part of the cultural heritage of humanity. Their earthquake protection is a topic of great concern among researchers due to the strong damage suffered by these brittle and massive structures through the history. The identification of the seismic behavior and failure of towers under seismic loading is complex. This strongly depends on many factors such as soil characteristics, geometry, mechanical properties of masonry and heavy mass, as well as the earthquake frequency content. A deep understanding of these aspects is the key for the correct seismic vulnerability evaluation of towers and to design the most suitable retrofitting measure. Recent tendencies on the seismic retrofitting of historical structures by means of prestressing are related to the use of smart materials. The most famous cases of application of prestressing in towers were discussed. Compared to horizontal prestressing, vertical post-tensioning is aimed at improving the seismic behavior of towers by reducing damage with the application of an overall distribution of compressive stresses at key locations.

A reliability-based fragility assessment method for seismic pounding between nonlinear buildings

  • Liu, Pei;Zhu, Hai-Xin;Fan, Peng-Peng;Yang, Wei-Guo
    • Structural Engineering and Mechanics
    • /
    • 제77권1호
    • /
    • pp.19-35
    • /
    • 2021
  • Existing methods to estimate the probability of seismic pounding occurrence of adjacent buildings do not account for nonlinear behavior or only apply to simple lumped mass systems. The present study proposes an efficient method based on subset simulation for fragility and risk assessment of seismic pounding occurrence between nonlinear adjacent buildings neglecting pounding effects with application to finite element models. The proposed method is first applied to adjacent buildings modeled as elastoplastic systems with substantially different dynamic properties for different structural parameters. Seismic pounding fragility and risk of adjacent frame structures with different floor levels is then assessed, paying special attention to modeling the non-linear material behavior in finite element models. Difference in natural periods and impact location are identified to affect the pounding fragility simultaneously. The reliability levels of the minimum code-specified separation distances are also determined. In addition, the incremental dynamic analysis method is extended to assess seismic pounding fragility of the adjacent frame structures, resulting in higher fragility estimates for separation distances larger than the minimum code-specified ones in comparison with the proposed method.

Seismic bearing capacity of shallow embedded strip footing on rock slopes

  • Das, Shuvankar;Halder, Koushik;Chakraborty, Debarghya
    • Geomechanics and Engineering
    • /
    • 제30권2호
    • /
    • pp.123-138
    • /
    • 2022
  • Present study computes the ultimate bearing capacity of an embedded strip footing situated on the rock slope subjected to seismic loading. Influences of embedment depth of strip footing, horizontal seismic acceleration coefficient, rock slope angle, Geological Strength Index, normalized uniaxial compressive strength of rock mass, disturbance factor, and Hoek-Brown material constant are studied in detail. To perform the analysis, the lower bound finite element limit analysis method in combination with the semidefinite programming is utilized. From the results of the present study, it can be found that the magnitude of the bearing capacity factor reduces quite substantially with an increment in the seismic loading. In addition, with the increment in slope angle, further reduction in the value of the bearing capacity factor is observed. On the other hand, with an increment in the embedment depth, an increment in the value of the bearing capacity factor is found. Stress contours are presented to describe the combined failure mechanism of the footing-rock slope system in the presence of static as well as seismic loadings for the different embedment depths.

TMD 설치에 따른 돔 형상 대공간 구조물의 지진응답분석 (Seismic Response Analysis of Dome-Shaped Large Spatial Structures According to TMD Installation)

  • 구승연;유상호;김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제23권4호
    • /
    • pp.27-34
    • /
    • 2023
  • In this study, the seismic response characteristics of the three analysis model with or without TMD were investigated to find out the effective dome shape. The three analysis models are rib type, lattice type and geodesic type dome structure composed of space frame. The maximum vertical and horizontal displacements were evaluated at 1/4 point of the span by applying the resonance harmonic load and historical earthquake loads (El Centro, Kobe, Northridge earthquakes). The study of the effective TMD installation position for the dome structure shows that seismic response control was effective when eight TMDs were installed in all types of analysis model. The investigation of the efficiency of TMD according to dome shape presents that lattice dome and geodesic dome show excellent control performance, while rib dome shows different control performance depending on the historical seismic loads. Therefore, lattice and geodesic types are desirable for seismic response reduction using TMD compared to rib type.

근단층지반운동에 대한 상부구조 질량 변화에 따른 RC 교각의 응답분석 (Response Analysis of RC Bridge Pier with Various Superstructure Mass under Near-Fault Ground Motion)

  • 박창규;정영수;이대형
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.667-673
    • /
    • 2010
  • 근단층지반운동은 진앙거리가 약 10 km 이내인 지역에서 관측되는 장주기 성분의 펄스형태를 갖는 지반운동으로서, 도심지에서 발생할 경우 미국 Northridge(1994), 일본 Kobe(1995), 터키 Izmit(1999), 중국 쓰촨성(2008), 아이티지진(2010) 등과 같이 매우 큰 피해를 야기시킨다. 이에 강진지역에서는 NFGM에 대한 많은 연구가 수행되었으나 우리나라와 같은 중약진 지역에서는 매우 미흡한 실정이다. 이 연구에서는 근단층 지반운동을 받는 철근콘크리트 교각의 거동과 내진성능을 평가하기 위하여 6기의 실험체에 대하여 진동대 실험을 수행하였다. 주요 실험 변수로는 심부구속철근비와 상부질량 크기로서 진동대 실험 결과 심부구속철근비가 적거나 상부질량이 클수록 교각의 내진성능이 저하됨을 알 수 있었다. 또한 진동대 실험 결과를 분석하여 지진동을 받는 교각의 강성변화에 대한 심부구속철근비와 질량의 영향을 분석하였으며, 변위연성도와 강성과의 관계식을 제안하였다.

동흡진기 적용을 통한 원전기기의 내진성능향상에 관한 수치적 연구 (A Numerical Study on Improvement in Seismic Performance of Nuclear Components by Applying Dynamic Absorber)

  • 곽신영;곽진성;이환호;오진호;구경회
    • 한국전산구조공학회논문집
    • /
    • 제32권1호
    • /
    • pp.17-27
    • /
    • 2019
  • 본 논문에서는 지진 하중 하에서 파이핑 시스템의 내진성능향상을 위하여 TMD의 적용성을 검토하였다. 이를 위하여 대상 파이프라인의 모드해석을 수행하였고, 이 중 방향별 질량참여율이 비교적 큰 1, 2 및 4번째 모드를 TMD 설치 위치로 선정하였다. 선정된 위치에 TMD 설계를 위하여 각각의 해당 모드를 단자유도 감쇠모델로 치환하고, TMD를 단자유도 감쇠모델로 고려하여 해당 파이프라인을 2자유도 시스템으로 변환하였다. 다음으로, 조화 지반 가진을 받는 변환된 2자유도 시스템의 응답증폭계수를 최소화할 수 있는 TMD의 강성 및 감쇠계수 값을 GA 최적화 방법을 통해 도출하였다. 이렇게 도출된 TMD 최적 설계 값을 파이프라인 수치모델에 적용하여 TMD 설치 유무에 따른 내진성능을 분석하였다. 수치해석 결과, TMD 설치 구간 배관부에서 방향 별 가속도 응답이 18%~51% 가량 감소함을 확인할 수 있었다. 배관부에 발생할 수 있는 최대 수직응력의 크기는 TMD 설치로 인하여 41%의 응력 감소가 있음을 확인할 수 있었다. 파이프라인 시스템의 최하단 앵커지점의 방향 별 반력은 원래의 최대 반력 세기에서 각각 37%, 34%, 43% 감소됨을 확인할 수 있었다. 이러한 연구 결과는 향후 목표로 하는 원전의 주요 파이핑 시스템의 내진성능향상과 관련한 기초 자료로 활용될 수 있을 것으로 판단된다.

Role of accidental torsion in seismic reliability assessment for steel buildings

  • Chang, Heui-Yung;Lin, Chu-Chieh Jay;Lin, Ker-Chun;Chen, Jung-Yu
    • Steel and Composite Structures
    • /
    • 제9권5호
    • /
    • pp.457-471
    • /
    • 2009
  • This study investigates the role of accidental torsion in seismic reliability assessment. The analyzed structures are regular 6-story and 20-story steel office buildings. The eccentricity in a floor plan was simulated by shifting the mass from the centroid by 5% of the dimension normal to earthquake shaking. The eccentricity along building heights was replicated by Latin hypercube sampling. The fragilities for immediate occupancy and life safety were evaluated using 0.7% and 2.5% inter-story drift limits. Two limit-state probabilities and the corresponding earthquake intensities were compared. The effect of ignoring accidental torsion and the use of code accidental eccentricity were also assessed. The results show that accidental torsion may influence differently the structural reliability and limit-state PGAs. In terms of structural reliability, significant differences in the probability of failure are obtained depending on whether accidental torsion is considered or not. In terms of limit-state PGAs, accidental torsion does not have a significant effect. In detail, ignoring accidental torsion leads to underestimates in low-rise buildings and at small drift limits. On the other hand, the use of code accidental eccentricity gives conservative estimates, especially in high-rise buildings at small drift limits.

Nonlinear interaction behaviour of infilled frame-isolated footings-soil system subjected to seismic loading

  • Agrawal, Ramakant;Hora, M.S.
    • Structural Engineering and Mechanics
    • /
    • 제44권1호
    • /
    • pp.85-107
    • /
    • 2012
  • The building frame and its foundation along with the soil on which it rests, together constitute a complete structural system. In the conventional analysis, a structure is analysed as an independent frame assuming unyielding supports and the interactive response of soil-foundation is disregarded. This kind of analysis does not provide realistic behaviour and sometimes may cause failure of the structure. Also, the conventional analysis considers infill wall as non-structural elements and ignores its interaction with the bounding frame. In fact, the infill wall provides lateral stiffness and thus plays vital role in resisting the seismic forces. Thus, it is essential to consider its effect especially in case of high rise buildings. In the present research work the building frame, infill wall, isolated column footings (open foundation) and soil mass are considered to act as a single integral compatible structural unit to predict the nonlinear interaction behaviour of the composite system under seismic forces. The coupled isoparametric finite-infinite elements have been used for modelling of the interaction system. The material of the frame, infill and column footings has been assumed to follow perfectly linear elastic relationship whereas the well known hyperbolic soil model is used to account for the nonlinearity of the soil mass.