• Title/Summary/Keyword: Seismic isolation system

Search Result 331, Processing Time 0.027 seconds

Structural monitoring and identification of civil infrastructure in the United States

  • Nagarajaiah, Satish;Erazo, Kalil
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.1
    • /
    • pp.51-69
    • /
    • 2016
  • Monitoring the performance and estimating the remaining useful life of aging civil infrastructure in the United States has been identified as a major objective in the civil engineering community. Structural health monitoring has emerged as a central tool to fulfill this objective. This paper presents a review of the major structural monitoring programs that have been recently implemented in the United States, focusing on the integrity and performance assessment of large-scale structural systems. Applications where response data from a monitoring program have been used to detect and correct structural deficiencies are highlighted. These applications include (but are not limited to): i) Post-earthquake damage assessment of buildings and bridges; ii) Monitoring of cables vibration in cable-stayed bridges; iii) Evaluation of the effectiveness of technologies for retrofit and seismic protection, such as base isolation systems; and iv) Structural damage assessment of bridges after impact loads resulting from ship collisions. These and many other applications show that a structural health monitoring program is a powerful tool for structural damage and condition assessment, that can be used as part of a comprehensive decision-making process about possible actions that can be undertaken in a large-scale civil infrastructure system after potentially damaging events.

A Study on the Application of Friction Pendulum System in Main Control Room of Nuclear Power Plant (마찰진자를 이용한 면진장치의 원전 주 제어실 적용에 관한 연구)

  • Kim, Woo Bum;Lee, Kyung Jin
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.407-417
    • /
    • 2005
  • An experimental and analytical study was performed to apply the friction pendulum system (FPS) to the main control room of a nuclear power plant. A friction pendulum bearing was fabricated, and the dynamic response of the bearing was evaluated. A partial model of a main control room attached to the FPS was tested on the shake table. The model consisted of a cabinet, a $3m\times3m$ access floor, and four friction pendulum bearings. The artificial time history based on the floor response spectrum of the main control room was used as the earthquake input signal in the test. Comparisons between the analytical study and the experimental study were conducted to verify the results and to extend the experimental study to the range of parameters that could not be experimentally studied.

A Ultimate Shear Performance of Elastomeric Bearings (탄성받침의 극한전단성능)

  • Yoon, Hye-Jin;Kwahk, Im-Jong;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.117-120
    • /
    • 2008
  • The bridge bearings are devices absorbing the displacements of the superstructure. KS F 4420 relative to the design of elastomeric bearings in Korea allows shear deformation up to 70% of total rubber height. For the elastomeric bearings to fulfill their shear function required in the design, the stability of allowable shear strain of elastomeric bearings relative to the shear failure should be guaranteed. Moreover considering the possibility that elastomeric bearings are applied to the seismic design together with isolation devices, elastomeric bearings is supposed to display higher shear performance. In this paper ultimate shear performance tests were performed. The measured ultimate shear strains were over 200%. Therefore an allowable shear strain provision becomes safe. But elastomeric bearings expected to show their performance in one united body reveled the separation of components near 200% shear strain. These separation in elastomeric bearing can cause unexpected impact or concentrated stress to bridge system considering to application of seismic design. Therefore provision relevant to separation problem is necessary.

  • PDF

A Study on the Application of EQS bearings for the Seismic Isolation of Building Structures by ICT Case study (ICT센터 사례 연구를 통한 EQS의 건축 구조물 면진에의 적용 연구)

  • Yu, Seong-Mun;Lee, You-In;Ji, Yong-Soo;Choi, Dae-Sung;Kim, Doo-Kie
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.61-70
    • /
    • 2013
  • An application of the EQS (Eradi Quake System) bearings to a short period building structure and the structure earthquake responses according to the design parameters of the EQS are studied by the ICT Center case study. The features of the EQS application to seismic isolated building structures are investigated, and the design procedure to determine the yield load and the secondary stiffness of the EQS is also studied. A computational analysis is performed to confirm the applicability of the EQS to the building structure and the earthquake responses according to the design parameters. The ICT Center in Indonesia is adopted as an application case of the EQS. The application of the EQS is found to extend the fundamental period of the ICT Center. Three types of EQS with different yield loads and secondary stiffness are designed and applied in the earthquake response analyses. The analysis results show the response of the structure with respect to the design parameters and which type of EQS is suitable for the ICT Center.

A Study on Complement of the Design and Analysis Procedures of Friction Pendulum System (마찰진자형 면진받침의 설계 및 해석절차 보완에 관한 연구)

  • Kim, Hyun-Uk;Joo, Kwang-Ho;Noh, Sang-Hoon;Song, Jong-Keol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.488-494
    • /
    • 2014
  • Although friction pendulum system has various advantages it is difficult to estimate the behavior because of velocity, bearing pressure, and temperature dependent characteristics of coefficient of friction. This research focuses on evaluating the conservatism of each method used and the effects of bearing pressure on the behavior of the system by conducting comprehensive examination on design and analytic procedure of friction pendulum system, as is proposed in standard, code and literature. In addition, this study provides comparative analysis on general behavior characteristics of friction pendulum system by comparing the result with that of the analysis on lead rubber bearing which possesses the same dynamic properties.

Evaluation on the Structural Performance of Hybrid Damper Using High-damping Rubber and Steel (고감쇠고무와 강재를 이용한 복합제진댐퍼의 구조성능평가)

  • Kim, Ji-Young;Jung, In-Yong;Kim, Hyung-Geun;Kim, Do-Hyun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.3
    • /
    • pp.99-106
    • /
    • 2016
  • The proposed hybrid damper installs at a coupling beam and consists of a high-damping rubber (HDR) and steel pin. The proposed hybrid damper adopted a pin-lock system acts as a viscoelastic damper under wind load (small displacement) while it behaves as a hysteretic damper under earthquake load (large displacement). In this paper, the pin-lock mechanism and structural performance of the proposed hybrid damper is evaluated through experiment. Experiments were carried out with the variables which displacement, loading frequency and steel pin quantities were used. Test results showed that the pin-lock mechanism and the performance of the hybrid damper under a large displacement were verified. Also equivalent damping ratios of HDR were increasing at a small displacement as displacement amplitudes were increasing. However HDR did not depend on frequency.

Random Response Analysis of Base Isolated Nuclear Container System (기초분리된 원전 격납구조물의 무작위 반응해석)

  • 홍원기;전제성;유광호
    • Computational Structural Engineering
    • /
    • v.7 no.4
    • /
    • pp.145-150
    • /
    • 1994
  • Seismic isolation in ordinary buildings has been successively adapted to provide flexibility for the reduction of base shear forces and its concept is accepting wide agreement in lengthening the natural, period to lessen the spectral acceleration transmitted into the structure. However, one of difficulties in implementing the innovative concept to nuclear structures is due to more severe requirements in both understanding and predicting the characteristics of isolators and the behavior of cushioned structures, Stochastic analysis has been carried out to investigate the response of base isolated nuclear containers to the random earthquake ground motion.

  • PDF

Development of High Damping Alloys for Reduction of Noise and Vibration (소음.진동 제어를 위한 방진합금 개발)

  • Baik, Seung-Han;Kim, Jung-Chul;Han, Dong-Woon;Baik, Jin-Hyun;Kim, Tai-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.565-569
    • /
    • 2004
  • Conventional methods for reducing vibration in engineering designs (i.e. by stiffening or detuning) may be undesirable or inadequate in conditions where size or weight must be minimized or where complex vibration spectra exist. Alloys which combine high damping capacity with good mechanical properties can provide attractive technical and economic solutions to problems involving seismic, shock and vibration isolation. To meet these trends, we have developed a new high damping Fe-17%Mn alloys. Also, the alloy has advantages of good mechanical properties and more economical than any other known damping alloys(1/4 times as cost of non-ferrous damping alloy). Thus, the high damping Fe-17%6Mn alloy can be widely applied to household appliances, automobiles, industrial facilities and power plant components with its excellent damping capacity(SDC, 30%) and mechanical property(T.S 700MPa). It is the purpose of this paper to introduce the characterization of the high damping Fe-17%Mn alloy and the results of retrofit several such applications.

  • PDF

Vibration characteristics change of a base-isolated building with semi-active dampers before, during, and after the 2011 Great East Japan earthquake

  • Dan, Maki;Ishizawa, Yuji;Tanaka, Sho;Nakahara, Shuchi;Wakayama, Shizuka;Kohiyama, Masayuki
    • Earthquakes and Structures
    • /
    • v.8 no.4
    • /
    • pp.889-913
    • /
    • 2015
  • Structural vibration characteristics of a semi-active base-isolated building were investigated using seismic observation records including those of the 2011 Great East Japan earthquake (Tohoku earthquake). Three different types of analyses were conducted. First, we investigated the long-term changes in the natural frequencies and damping factors by using an ARX model and confirmed that the natural frequency of the superstructure decreased slightly after the main shock of the Tohoku earthquake. Second, we investigated short-term changes in the natural frequencies and damping factors during the main shock by using the N4SID method and observed different transition characteristics between the first and second modes. In the second mode, in which the superstructure response is most significant, the natural frequency changed depending on the response amplitude. In addition, at the beginning of the ground motion, the identified first natural frequency was high possibly as a result of sliding friction. Third, we compared the natural frequencies and damping factors between the conditions of a properly functional semi-active control system and a nonfunctional system, by using the records of the aftershocks of the Tohoku earthquake. However, we could not detect major differences because the response was probably influenced by sliding friction, which had a more significant effect on damping characteristics than did the semi-active dampers.

CONCEPTUAL DESIGN OF THE SODIUM-COOLED FAST REACTOR KALIMER-600

  • Hahn, Do-Hee;Kim, Yeong-Il;Lee, Chan-Bock;Kim, Seong-O;Lee, Jae-Han;Lee, Yong-Bum;Kim, Byung-Ho;Jeong, Hae-Yong
    • Nuclear Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.193-206
    • /
    • 2007
  • The Korea Atomic Energy Research Institute has developed an advanced fast reactor concept, KALIMER-600, which satisfies the Generation IV reactor design goals of sustainability, economics, safety, and proliferation resistance. The concept enables an efficient utilization of uranium resources and a reduction of the radioactive waste. The core design has been developed with a strong emphasis on proliferation resistance by adopting a single enrichment fuel without blanket assemblies. In addition, a passive residual heat removal system, shortened intermediate heat-transport system piping and seismic isolation have been realized in the reactor system design as enhancements to its safety and economics. The inherent safety characteristics of the KALIMER-600 design have been confirmed by a safety analysis of its bounding events. Research on important thermal-hydraulic phenomena and sensing technologies were performed to support the design study. The integrity of the reactor head against creep fatigue was confirmed using a CFD method, and a model for density-wave instability in a helical-coiled steam generator was developed. Gas entrainment on an agitating pool surface was investigated and an experimental correlation on a critical entrainment condition was obtained. An experimental study on sodium-water reactions was also performed to validate the developed SELPSTA code, which predicts the data accurately. An acoustic leak detection method utilizing a neural network and signal processing units were developed and applied successfully for the detection of a signal up to a noise level of -20 dB. Waveguide sensor visualization technology is being developed to inspect the reactor internals and fuel subassemblies. These research and developmental efforts contribute significantly to enhance the safety, economics, and efficiency of the KALIMER-600 design concept.