• Title/Summary/Keyword: Seismic isolation design

Search Result 246, Processing Time 0.026 seconds

Development and experimental study on cable-sliding modular expansion joints

  • Gao, Kang;Yuan, Wan C.;Dang, Xin Z.
    • Structural Engineering and Mechanics
    • /
    • v.61 no.6
    • /
    • pp.795-806
    • /
    • 2017
  • According to the characteristics of continuous beam bridges, the relative displacement is too large to collision or even girder falling under earthquakes. A device named Cable-sliding Modular Expansion Joints(CMEJs) that can control the relative displacement and avoid collision under different ground motions is proposed. Working principle and mechanical model is described. This paper design the CMEJs, establish the restoring force model, verify the force model of this device by the pseudo-static tests, and describe and analyze results of the tests, and then based on a triple continuous beam bridge that has different heights of piers, a 3D model with or without CMEJs were established under Conventional System (CS) and Seismic Isolation System (SIS). The results show that this device can control the relative displacement and avoid collisions. The combination of isolation technology and CMEJs can be more effective to achieve both functions, but it need to take measures to prevent girder falling due to the displacement between pier and beam under large earthquakes.

Seismic Responses of Isolated Bridges Considering the Relative Stiffness Ratio (상대강성비를 고려한 지진격리교량의 응답특성)

  • Seo, Hyun-Woo;Kim, Nam-Sik;Cheung, Jin-Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.12 s.105
    • /
    • pp.1340-1346
    • /
    • 2005
  • In this study, based on shaking table test results on a seismically isolated bridge model, an inelastic numerical model is refined by using Bouc-Wen model representing the hysteretic behavior of isolators. Seismic responses of isolated bridges are numerically investigated varying with relative stiffness ratio(RSR), which is a ratio of the effective stiffness of isolator to the lateral stiffness of bridge pier, From the results, it is found that an adequate range of relative stiffness ratio could be defined for seismic design of isolated bridges without considering the flexibility of piers.

Vibration control of hysteretic base-isolated structures: an LMI approach

  • Pozo, Francesc;Pujol, Gisela;Acho, Leonardo
    • Smart Structures and Systems
    • /
    • v.17 no.2
    • /
    • pp.195-208
    • /
    • 2016
  • Seismic isolation systems are essentially designed to preserve structural safety, prevent occupants injury and properties damage. An active saturated LMI-based control design is proposed to attenuate seismic disturbances in base-isolated structures under saturation actuators. Using a mathematical model of an eight-storied building structure, an active control algorithm is designed. Performance evaluation of the controller is carried out in a simplified model version of a benchmark building system, which is recognized as a state-of-the-art model for numerical experiments of structures under seismic perturbations. Experimental results show that the proposed algorithm is robust with respect to model and seismic perturbations. Finally, the performance indices show that the proposed controller behaves satisfactorily and with a reasonable control effort.

Pseudo Dynamic Test of the Seismically Isolated RC Piers (지진격리설계된 RC교각의 유사동적 실험)

  • Kim Young-Jin;Kwahk Im-Jong;Cho Chang-Beck;Kwark Jong-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.25-28
    • /
    • 2004
  • Many highway bridges in Korea need seismic retrofit because only one decade has passed since the seismic design criteria was introduced. In this experimental study, the effectiveness of base isolation bearings was discussed for the seismic retrofit of the highway bridges. Four real scale RC pier specimens were constructed for the test. These RC piers didn't have seismic details. Except for one RC pier for the pilot test, three types of bearings such as Pot bearing, Rubber bearing (RB), Lead-rubber bearing (LRB) were applied to the other RC piers respectively. The RC pier with Pot bearing means current state of the prototype bridge that is not retrofitted seismically. And two RC piers with RB or LRB mean assumed states of the prototype bridge that are retrofitted seismically. To simulate dynamic behavior of these RC piers under earthquake loads, Pseudo-dynamic test method was used.

  • PDF

Study of Integrated Optimal Design of Smart Top-Story Isolation and Building Structures in Regions of Low-to-Moderate Seismicity (중약진지역 구조물과 스마트 최상층 면진시스템의 통합최적설계에 대한 연구)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.13-20
    • /
    • 2013
  • In order to reduce seismic responses of a structure, additional dampers and vibration control devices are generally considered. Usually, control performance of additional devices are investigated for optimal design without variation of characteristics of a structure. In this study, multi-objective integrated optimization of structure-smart control device is conducted and possibility of reduction of structural resources of a building structure with smart top-story isolation system has been investigated. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses. Based on numerical simulation results, it has been shown that a smart top-story isolation system can effectively reduce both structural responses and isolation story drifts of the building structure in low-to-moderate seismicity regions. The integrated optimal design method proposed in this study can provide various optimal designs that presents good control performance by appropriately reducing the amount of structural material and damping device.

Determination of Structural Performance Point Utilizing The Seismic Isolation Rubber Bearing Design Method (면진격리 고무베어링 설계법을 이용한 구조물의 성능점 예측)

  • 김창훈;좌동훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.23-30
    • /
    • 2003
  • The seismic base isolation design approach has been reviewed and modified to fit the nonlinear static analysis procedure for determination of the performance point of structures in a simpler way, such an adaptation may be possible for the fact that a structural system under development of damage due to earthquake loading keeps softening to result in period shifting toward longer side. The superiority of the proposed method to the state-of-the-practice approach is that the reasonably accurate performance point can be obtained without constructing the so-called acceleration displacement response spectrum required in application of capacity spectrum method. The validity of the proposed approach was verified by comparing the predicted values to the exact ones presented in the literature.

Development of the Damping Coefficients for Weak and Moderate Earthquake Ground Motions

  • Kim, Myeong-Han
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.1-6
    • /
    • 2008
  • Most of seismic design code provisions provide the design response spectra for defining design earthquake ground motions. The design spectra in the code provisions generally come under the 5% of critical damping value, which corresponds to the responses of common structure under the design earthquake. Energy dissipation devices and seismic isolation systems became more popular and the design response spectra at higher damping levels are required. Damping coefficients can be effectively used in conversion of 5%-damped design spectra into other damping levels. These coefficients in the current seismic design code provisions are based on the strong ground motion records. Since the weak and moderate earthquake data have different characteristics from those of strong earthquake data, the application of these coefficients should be investigated in the weak and moderate earthquakes zones. In this study, damping coefficients based on the weak and moderate ground motions were developed and compared to those of current seismic design code provisions.

Optimal design of the seismic protection system for isolated bridges

  • Losanno, Daniele;Spizzuoco, Mariacristina;Serino, Giorgio
    • Earthquakes and Structures
    • /
    • v.7 no.6
    • /
    • pp.969-999
    • /
    • 2014
  • Aim of the paper is the definition of optimal design parameters characterizing the isolation system of a bridge, both in the case of elastomeric (VI) and sliding bearings (SI), having viscoelastic or rigid-plastic behavior, respectively, installed between the piers and the deck. The problem is treated by means of an analytical approach. Using the frequency response analysis, a simple procedure is proposed to determine the optimal value of the viscous coefficient or the yield displacement of the isolators. The adequacy of the proposed procedure is finally verified through time-history analyses performed on a practical case under natural earthquakes.

Seismic Design of Prefabricated Light Weight Bridges (승용차 전용 조립식 고가도로의 내진설계 연구)

  • 강형택;박영하;김성훈;이일근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.288-294
    • /
    • 2003
  • Increasing the volume of traffic on the roads causes social and economical problems such as increasing air-pollution and distribution cost. Prefabricated light weight bridge becomes a possible solution for these problems in the urban area where it is difficult to construct new one or expend the existing road. There are some merits in this kind of bridge. First, the design live and dead loads are minimized by allowing only passenger cars. Second employing prefabrication construction scheme reduces the construction time. Third, there is no need to buy land if the elevation road is placed on the top of existing one. In seismic design of bridges, base isolation has been an effective solution when the bridge has stiff piers and a heavy superstructure. The prefabricated light weight bridge has different dynamic characteristics from the ordinary bridges. In this paper, the applicability of base isolators such as lead rubber bearing and elastomeric bearing, to prefabricated light weight bridge is examined.

  • PDF

Seismic behavior of structures isolated with a hybrid system of rubber bearings

  • Chen, Bo-Jen;Tsai, C.S.;Chung, L.L.;Chiang, Tsu-Cheng
    • Structural Engineering and Mechanics
    • /
    • v.22 no.6
    • /
    • pp.761-783
    • /
    • 2006
  • The enlargement of interest in base isolators as an earthquake-proof design strategy has dramatically accelerated experimental studies of elastomeric bearings worldwide. In this paper, a new base isolator concept that is a hybrid system of rubber bearings is proposed. Uniaxial, biaxial, and triaxial shaking table tests are also performed to study the seismic behavior of a 0.4-scale three-story isolated steel structure in the National Center for Research on Earthquake Engineering in Taiwan. Experimental results demonstrate that structures with a hybrid system of rubber bearings composed of stirruped rubber bearings and laminated rubber bearings can actually decrease the seismic responses of the superstructure. It has been proved through the shaking table tests that the proposed hybrid system of rubber bearings is a very promising tool to enhance the seismic resistance of structures. Moreover, it is demonstrated that the proposed analytical model in this paper can predict the mechanical behavior of the hybrid system of rubber bearings and seismic responses of the base-isolated structures.