• Title/Summary/Keyword: Seismic characteristics

Search Result 1,435, Processing Time 0.03 seconds

The Nature of Earthquake and Earthquake Resistant Building Design (지진의 성격과 건축물 내진설계에 대하여)

  • 양완수
    • Journal of the Korean Professional Engineers Association
    • /
    • v.28 no.2
    • /
    • pp.13-20
    • /
    • 1995
  • This paper Is to help the structural engineers for a better understanding of "Earthquake" with regard to the nature o( earthquake and the effect of earthquake on building structures. This reveals that the damage Inflicted upon by earthquake varies with many factors such as : magnitude of earthquake, distance from epicenter, site conditions, building structural characteristics and etc.. It is emphasized that in order to resist very strong earthquake, the ductility demand in the building structure Is important, and the proper duc-tility enables the structure to demonstrate inelastic rotation capacity of the joints and thus the structure may absorb and dissipate the seismic energy. This also presents a comparison between the current Americal UBC Code and the Korean Code, and the author expresses some points of concern on each code. Since earthquake almost invariably strikes at times and places, it is suggested that the current Korean Build-ing Code should be revised to enforce more stringent regulation against possible strong earthquake in the Korean peninsula.

  • PDF

An Experimental Study on the Similitude of Structural Behaviors for Small-Scale Modeling of Reinforced Concrete Structures (철근콘크리트 축소모델의 구조거동 상사성에 관한 실험연구)

  • 이한선;우성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.401-407
    • /
    • 1996
  • A 2-bay 2-story moment-resisting reinforced concrete plane frame with seismic detail was designed. One 1/2.5-scale and one 1/10th model subassemblages were manufactured accoring to the required similitude law. Then the reversed load tests under the displacement control were performed statically to these subassemblages. The results of these tests were compared regarding to the similitude in the characteristics of structural behaviors such as strength., stiffness, energy dissipation, failure modes and local deformations. Based on these results, the following conclussions were drawn : (1) The strength of 1/10 model was very similar to that of 1/2.5 specimen. (2) The initial stiffness of 1/10 model appers to be approximately 2/3 of that of 1/2.5 specimen. (3) 1/10 model has therefore smaller energy dissipation capacity than 1/2.5 specimen. (4) Inelastic excursion mechanisms of 1/2.5 specimen and 1/10 model apper to be a little different.

  • PDF

Strength and Ductility of R/C Columns with Welded Reinforcement Grids (용접된 띠철근으로 보강한 철근콘크리트 기둥의 강도와 연성)

  • ;Murat Saatcioglu;Mongi Grira
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.492-499
    • /
    • 1997
  • Experimental research was conducted to investigate structural performance of concrete columns confined with welded reinforcement grids were tested under simulated seismic loading. The columns were subjected to constant axial compression accompanied by incrementally increasing lateral deformation reversals. The results indicate thar welded reinforcement grid can be used effectively as confinement reinforcement provided that the steel used, have sufficient ductility and the welding process employed does not alter the strength and elongation characteristics of steel. The grids improved the structural performance of columns, which developed lateral drift ratios in excess of 3% with the spacing and volumetric ratio of transverse reinforcement similar to those required by the ACI 318-95 Building Code.

  • PDF

Outrigger Systems for Tall Buildings in Korea

  • Chung, Kwangryang;Sunu, Wonil
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.3
    • /
    • pp.209-217
    • /
    • 2015
  • Outrigger systems are highly efficient since they utilize the perimeter zone to resist lateral forces, similar to tubular systems. The entire structural weight can be reduced due to the system's significant lateral strength. Therefore, it is the most commonly selected structural system for tall and supertall buildings built in recent years. In this paper, issues regarding the differential shortening effect during construction of the outrigger system and the special joints used to solve these issues will be addressed. Additionally, the characteristics of wind and seismic loads in Korea will be briefly discussed. Lastly, buildings in Korea using an outrigger as their major structural system will be introduced and the structural role of the system will be analyzed.

Numerical investigation of potential mitigation measures for poundings of seismically isolated buildings

  • Polycarpou, Panayiotis C.;Komodromos, Petros
    • Earthquakes and Structures
    • /
    • v.2 no.1
    • /
    • pp.1-24
    • /
    • 2011
  • During very strong earthquakes, seismically isolated buildings may experience large horizontal relative displacements, which may lead to poundings if an insufficiently wide clearance is provided around the building. This paper investigates, through numerical simulations, the effectiveness of using rubber bumpers, which could be attached at locations where it is likely to have impacts, in order to act as shock-absorbers. For the simulation of the dynamic behavior of such rubber bumpers during impacts, a nonlinear force-based impact model, which takes into account the finite thickness of the rubber bumpers, has been developed. Subsequently, a series of parametric analyses are performed to assess the effect of the gap size, the earthquake characteristics and the thickness, compressive capacity and damping of the bumpers. The stiffness of the moat wall is also parametrically considered during poundings of a seismically isolated building, as another potential mitigation measure for poundings of seismically isolated buildings.

Quasi-Static Test of Precast Concrete Large Panel Subassemblage (P.C 대형판넬 부분구조물의 Quasi-Static 실험연구)

  • Choi, Jeong-Su;Lee, Han-Seon;Kim, U;Hong, Gap-Pyo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.10a
    • /
    • pp.73-78
    • /
    • 1990
  • Large panel building systems are composed of vertical wall panels which support horizontal roof and floor panels to form a box like structure. The simplecity of the connections, which makes precast concrete economically viable, causes a lack of continuity in stiffness, strength and ductility. This precast concrete large panel systems typically have weak connection regions. Three types of 2-story full-scale precast concrete subassemblages were tested under reversed cyclic loading. The seismic resistance capacity and failure mode of each system are compared in connection with the characteristics of joint connection details.

  • PDF

Performance Evaluation of a RC Structure (철근콘크리트 구조물의 성능기초평가)

  • Lee, Do-Hyung;Park, Tae-Hyo;Yun, Sung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.381-384
    • /
    • 2006
  • In order to evaluate the seismic performance of a reinforced concrete building structure, four different analyses are carried out. Firstly, conventional pushover analysis with code-specified inverted triangular load pattern is conducted. Secondly, the pushover analysis with uniform load pattern is performed. Thirdly, adaptive pushover analyses with spectral amplification for both EC 8 artificial and Northridge earthquake are carried out. Lastly, incremental dynamic analyses under a number of scaled PGA for both EC 8 artificial and Northridge earthquake record are performed. Comparative studies demonstrate that the adaptive pushover analysis may be able to explain the response characteristics that conventional pushover analysis with fixed load distribution fails to capture.

  • PDF

Shear Strength and Design of HPFRCCs Coupling Beam with Diagonal Reinforcement (대각 보강된 HPFRCCs 커플링 보의 전단강도 및 설계)

  • Park, Wan-Shin;Yun, Hyun-Do;Kim, Sun-Woo;Jean, Esther;Kim, Young-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.257-260
    • /
    • 2006
  • Coupled shear walls consist of two or more in-plane walls inter-connected with coupling beams. In order to effectively resist seismic loads, coupling beams must be sufficiently stiff, strong and posses a stable load-deflection hysteretic response. Much of requirements to the civil and building structures have recently been changed in accordance with the social and economic progress. Ductility of high performance fiber reinforced cementitious composites(HPFRCCs), which exhibit strain hardening and multiple crackling characteristics under the uniaxial tensile stress is drastically improved. This paper provides background for design guidelines that include a design model to calculate the shear strength of pseudo strain hardening cementitious composite steel coupling beam.

  • PDF

Applications of the wavelet transform in the generation and analysis of spectrum-compatible records

  • Suarez, Luis E.;Montejo, Luis A.
    • Structural Engineering and Mechanics
    • /
    • v.27 no.2
    • /
    • pp.173-197
    • /
    • 2007
  • A wavelet-based procedure to generate artificial accelerograms compatible with a prescribed seismic design spectrum is described. A procedure to perform a baseline correction of the compatible accelerograms is also described. To examine how the frequency content of the modified records evolves with time, they are analyzed in the time and frequency using the wavelet transform. The changes in the strong motion duration and input energy spectrum are also investigated. An alternative way to match the design spectrum, termed the "two-band matching procedure", is proposed with the objective of preserving the non-stationary characteristics of the original record in the modified accelerogram.

Development of nationwide amplification map of response spectrum for Japan based on station correction factors

  • Maruyama, Yoshihisa;Sakemoto, Masaki
    • Earthquakes and Structures
    • /
    • v.13 no.1
    • /
    • pp.17-27
    • /
    • 2017
  • In this study, the characteristics of site amplification at seismic observation stations in Japan were estimated using the attenuation relationship of each station's response spectrum. Ground motion records observed after 32 earthquakes were employed to construct the attenuation relationship. The station correction factor at each KiK-net station was compared to the transfer functions between the base rock and the surface. For each station, the plot of the station correction factor versus the period was similar in shape to the graphs of the transfer function (amplitude ratio versus period). Therefore, the station correction factors are effective for evaluating site amplifications considering the period of ground shaking. In addition, the station correction factors were evaluated with respect to the average shear wave velocities using a geographic information system (GIS) dataset. Lastly, the site amplifications for specific periods were estimated throughout Japan.