• Title/Summary/Keyword: Seismic Performance Characteristics

검색결과 446건 처리시간 0.021초

Bayesian approach for the accuracy evaluating of the seismic demand estimation of SMRF

  • Ayoub Mehri Dehno;Hasan Aghabarati;Mehdi Mahdavi Adeli
    • Earthquakes and Structures
    • /
    • 제26권2호
    • /
    • pp.117-130
    • /
    • 2024
  • Probabilistic model of seismic demand is the main tool used for seismic demand estimation, which is a fundamental component of the new performance-based design method. This model seeks to mathematically relate the seismic demand parameter and the ground motion intensity measure. This study is intended to use Bayesian analysis to evaluate the accuracy of the seismic demand estimation of Steel moment resisting frames (SMRFs) through a completely Bayesian method in statistical calculations. In this study, two types of intensity measures (earthquake intensity-related indices such as magnitude and distance and intensity indices related to ground motion and spectral response including peak ground acceleration (PGA) and spectral acceleration (SA)) have been used to form the models. In addition, an extensive database consisting of sixty accelerograms was used for time-series analysis, and the target structures included five SMRFs of three, six, nine, twelve and fifteen stories. The results of this study showed that for low-rise frames, first mode spectral acceleration index is sufficient to accurately estimate demand. However, for high-rise frames, two parameters should be used to increase the accuracy. In addition, adding the product of the square of earthquake magnitude multiplied by distance to the model can significantly increase the accuracy of seismic demand estimation.

가능최대지진(MCE)을 적용한 콘크리트 댐 피어부 내진성능평가 방안 개선 (Improvement of Seismic Performance Evaluation Method for Concrete Dam Pier by Applying Maximum Credible Earthquake(MCE))

  • 오정근;정영석;권민호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.1-12
    • /
    • 2023
  • 본 논문에서는 MCE를 적용한 콘크리트 댐 피어부의 동적소성해석을 통한 내진성능평가 수행 시 소성재료모델, 성능수준 평가 방법에 대한 현행 기준의 적용성을 검토하고 개선안을 제시하였다. 다양한 조건으로 동적소성해석을 수행하여 소성재료모델에 대한 적용성을 검토하였고, 그 결과 현행 댐 내진성능평가요령에서 제시하는 평균응력-평균변형률 기법은 최소철근비가 확보되지 않은 조건에서 동적탄성해석으로 예측한 결과보다 피어부의 응답을 과소평가하는 것으로 확인되었다. 따라서 최소철근비가 확보되지 않은 댐 피어부는 무근콘크리트로 간주하여 콘크리트 인장거동특성에 파괴에너지를 적용하는 방법으로 피어부 성능수준을 평가하도록 하는 개선안을 도출하였다. 개선사항 적용할 경우 현행 내진성능평가 방법보다 보수적인 평가결과를 도출할 수 있다.

섬유 및 강성 보강재료 기반 도시철도 내진성능 보강공법적용의 문제점 연구 (A Study on the Problem of Application of Seismic Performance Reinforcement Method for Urban Railways Case of Fiber and Rigid Reinforcement)

  • 하경화;박재일;강휘진
    • 한국방재안전학회논문집
    • /
    • 제13권1호
    • /
    • pp.13-23
    • /
    • 2020
  • 국내 도시철도는 2005년 내진설계가 본격적으로 도입되었으며, 내진성능평가 및 보강방법에 대한 많은 연구가 이루어졌다. 2009년 3월 공포된 지진재해대책법 시행령(현 지진화산재해 대책법 시행령)에 따라 2010년4월~2013년10월까지 일부 지자체에서 도시철도 지하화 구간의 내진성능 상세 평가 및 보강방안을 수립하였다. 그 후, 2018년 말까지 공용기간이 오래된 구간에 대하여 기존 도시철도의 내진성능 평가를 수행하였으며, 기 연구된 방법을 적용하여 다양한 공법으로 보강공사를 시행하고 있다. 그러나 다양한 보강재료과 이를 사용한 공법이 연구되었지만, 현재 도시철도 보강공사에 적용되고 있는 공법에 대한 분류 실태연구는 미비하다. 본 연구의 목적은 현재 도시철도 내진성능보강 공사에 적용중인 사례를 분석하여, 공법별 특징 및 적용 사유와 문제점을 제시하는데 있다.

FE model updating and seismic performance evaluation of a historical masonry clock tower

  • Gunaydin, Murat;Erturk, Esin;Genc, Ali Fuat;Okur, Fatih Yesevi;Altunisik, Ahmet Can;Tavsan, Cengiz
    • Earthquakes and Structures
    • /
    • 제22권1호
    • /
    • pp.65-82
    • /
    • 2022
  • This paper presents a structural performance assessment of a historical masonry clock tower both using numerical and experimental process. The numerical assessment includes developing of finite element model with considering different types of soil-structure interaction systems, identifying the numerical dynamic characteristics, finite element model updating procedure, nonlinear time-history analysis and evaluation of seismic performance level. The experimental study involves determining experimental dynamic characteristics using operational modal analysis test method. Through the numerical and experimental processes, the current structural behavior of the masonry clock tower was evaluated. The first five experimental natural frequencies were obtained within 1.479-9.991 Hz. Maximum difference between numerical and experimental natural frequencies, obtained as 20.26%, was reduced to 4.90% by means of the use of updating procedure. According to the results of the nonlinear time-history analysis, maximum displacement was calculated as 0.213 m. The maximum and minimum principal stresses were calculated as 0.20 MPa and 1.40 MPa. In terms of displacement control, the clock tower showed only controlled damage level during the applied earthquake record.

Performance based optimal seismic retrofitting of yielding plane frames using added viscous damping

  • Lavan, O.;Levy, R.
    • Earthquakes and Structures
    • /
    • 제1권3호
    • /
    • pp.307-326
    • /
    • 2010
  • This paper is concerned with the optimal seismic design of added viscous dampers in yielding plane frames. The total added damping is minimized for allowable values of local performance indices under the excitation of an ensemble of ground motions in both regular and irregular structures. The local performance indices are taken as the maximal inter-story drift of each story and/or the normalized hysteretic energy dissipated at each of the plastic hinges. Gradients of the constraints with respect to the design variables (damping coefficients) are derived, via optimal control theory, to enable an efficient first order optimization scheme to be used for the solution of the problem. An example of a ten story three bay frame is presented. This example reveals the following 'fully stressed characteristics' of the optimal solution: damping is assigned only to stories for which the local performance index has reached the allowable value. This may enable the application of efficient and practical analysis/redesign type methods for the optimal design of viscous dampers in yielding plane frames.

천장 브래킷을 이용한 완전강접합 모듈러 시스템의 구조성능 (Structural Performance of the Modular System with Fully Restrained Moment Connections using Ceiling Bracket)

  • 이승재;곽의신;박재성;강창훈;손수덕
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.37-44
    • /
    • 2017
  • Due to structural characteristics, construction costs and duration of a modular system would be saved by minimizing the schedule on the job site. As such, it is crucial to develop a connection that can guarantee stiffness while allowing for simple assembling. Particularly, the mid- to high-rise construction of the modular system necessitates the securing of the structural stability and seismic performance of multi-unit frames and connections, and thus, the stiffness of unit-assembled structures needs to be re-evaluated and designed. However, evaluating a frame consisting of slender members and reinforcing materials is a complicated process. Therefore, the present study aims to examine the structural characteristics of a modular unit connection based a method for reinforcing connection brackets and hinges while minimizing the loss of the cross section. Toward this end, the study modeled the beam-to-column connection of a modular system with the proposed connection, and produced a specimen which was used to perform a cycling loading test. The study compared the initial stiffness, the attributes of the hysteretic behavior, and the maximum flexural moment, and observed whether the model acquired the seismic performance, compared to the flexural strength of the steel moment frame connection that is required by the Korean Building Code. The test results showed that the proposed connection produced a similar initial stiffness value to that of the theoretical equation, and its maximum strength exceeded the theoretical strength. Furthermore, the model with a larger ceiling bracket showed higher seismic performance, which was further increased by the reinforcement of the plate.

A comparison of three performance-based seismic design methods for plane steel braced frames

  • Kalapodis, Nicos A.;Papagiannopoulos, George A.;Beskos, Dimitri E.
    • Earthquakes and Structures
    • /
    • 제18권1호
    • /
    • pp.27-44
    • /
    • 2020
  • This work presents a comparison of three performance-based seismic design methods (PBSD) as applied to plane steel frames having eccentric braces (EBFs) and buckling restrained braces (BRBFs). The first method uses equivalent modal damping ratios (ξk), referring to an equivalent multi-degree-of-freedom (MDOF) linear system, which retains the mass, the elastic stiffness and responds in the same way as the original non-linear MDOF system. The second method employs modal strength reduction factors (${\bar{q}}_k$) resulting from the corresponding modal damping ratios. Contrary to the behavior factors of code based design methods, both ξk and ${\bar{q}}_k$ account for the first few modes of significance and incorporate target deformation metrics like inter-storey drift ratio (IDR) and local ductility as well as structural characteristics like structural natural period, and soil types. Explicit empirical expressions of ξk and ${\bar{q}}_k$, recently presented by the present authors elsewhere, are also provided here for reasons of completeness and easy reference. The third method, developed here by the authors, is based on a hybrid force/displacement (HFD) seismic design scheme, since it combines the force-base design (FBD) method with the displacement-based design (DBD) method. According to this method, seismic design is accomplished by using a behavior factor (qh), empirically expressed in terms of the global ductility of the frame, which takes into account both non-structural and structural deformation metrics. These expressions for qh are obtained through extensive parametric studies involving non-linear dynamic analysis (NLDA) of 98 frames, subjected to 100 far-fault ground motions that correspond to four soil types of Eurocode 8. Furthermore, these factors can be used in conjunction with an elastic acceleration design spectrum for seismic design purposes. Finally, a comparison among the above three seismic design methods and the Eurocode 8 method is conducted with the aid of non-linear dynamic analyses via representative numerical examples, involving plane steel EBFs and BRBFs.

LRB 댐퍼 조합형 지진격리장치 개발 및 특성평가실험 (Development of Seismic Isolation Device with LRB and Shock Transmission Units and Its Verification Tests)

  • 서주원;김남식;임진석;유문식
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.383-390
    • /
    • 2002
  • The new seismic isolation system (StLRB) is developed, which can separate non-seismic displacements which come from the thermal expansion etc. in LRB design. The StLRB has 3 components, sliding system (PTFE + stainless plate), LRB (lead rubber bearing) and STU (shock transmit units). In this project, the StLRB is designed to apply to the bridge structure by analyzing the characteristics of each component and also the dynamic behavior of the structure was analyzed by non-linear analysis. The verification test was performed to show the two stages separated by STU units. Test results show the effectiveness of both the separation and the seismic isolation performance.

  • PDF

Seismic design of a precast r.c. structure equipped with viscous dampers

  • Silvestri, Stefano;Gasparini, Giada;Trombetti, Tomaso
    • Earthquakes and Structures
    • /
    • 제2권3호
    • /
    • pp.297-321
    • /
    • 2011
  • The seismic design of a two-storey precast reinforced-concrete building structure equipped with viscous dampers is presented in this paper with twofold purpose. The first goal is to verify the applicability of a practical procedure for the identification of the mechanical characteristics of the viscous dampers which allow to achieve target performance levels, originally proposed by the authors for moment-resisting building frames, also with reference to "pendular" structures. The second goal is to investigate the effectiveness of the use of viscous dampers (as compared with traditional lateral-resisting stiff braces) for the seismic design of precast not moment-resisting concrete structures.

시간-주파수 누적 변화량과 가변 임계값을 이용한 지진 이벤트 자동 검출 알고리즘 (Earthquake Event Auto Detection Algorithm using Accumulated Time-Frequency Changes and Variable Threshold)

  • 최훈
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1179-1185
    • /
    • 2012
  • This paper presents a new approach for the detection of seismic events using accumulated changes on time-frequency domain and variable threshold. To detect seismic P-wave arrivals with rapidness and accuracy, it is that the changes on the time and the frequency domains are simultaneously used. Their changes are parameters appropriated to reflect characteristics of earthquakes over moderate magnitude(${\geq}$ magnitude 4.0) and microearthquakes. In addition, adaptively controlled threshold values can prevent false P-wave detections due to low SNR. We tested our method on real earthquakes those have various magnitudes. The proposed algorithm gives a good detection performance and it is also comparable to STA/LTA algorithm in computational complexity. Computer simulation results shows that the proposed algorithm is superior to the conventional popular algorithm (STA/LTA) in the seismic P-wave detection.