• Title/Summary/Keyword: Segmental

Search Result 1,155, Processing Time 0.038 seconds

Precast Segmental PSC Bridge Columns with Precast Concrete Footings : I. Development and Verification of System (조립식 기초부를 갖는 프리캐스트 세그먼트 PSC 교각 : I. 시스템 개발 및 검증)

  • Kim, Tae-Hoon;Park, Se-Jin;Kim, Young-Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.395-405
    • /
    • 2009
  • The purpose of this study was to investigate the performance of precast segmental PSC bridge columns with precast concrete footings. The proposed system can reduce work at a construction site and makes construction periods shorter. The precast concrete footings is intended to support precast segmental PSC bridge columns and provides an alternative to current cast-inplace systems, particularly for areas where reduced construction time is desired. Shortened construction time, in turn, leads to important safety and economic advantages when traffic disruption or rerouting is necessary. A model of precast segmental PSC bridge columns was tested under a constant axial load and a cyclically reversed horizontal load. In the companion paper, the experimental and analytical study for the performance assessment of precast segmental PSC bridge columns with precast concrete footings is performed.

The Behavior Characteristics of Segmental Crib Retaining Wall by Model Test (모형실험에 의한 조립식 격자 옹벽의 거동 특성)

  • 김상수;신방웅;김용언;이재영;변동건
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.449-456
    • /
    • 1999
  • The concrete wall is the most useful of retaining structure which can obtain the engineering stability, but has problems that is not friendly with nature environment in a fine view, such as poor rear drainage, and shrinkage crack by temperature difference, etc. Because of this problems, the research for a segmental crib retaining wall has been performed. A segmental crib retaining wall is quickly and easily erected because is possible to be erected as the individual members, and is not sensitive to differential settlement and earthquakes. Also, it shows effective drainage and has a friendly advantage with nature environment because of being able to be planted with vines and shrubs in retaining walls The design of crib retaining walls has traditionally been based on classical soil mechanics theories. These theories, originally derived by Rankine(1857) and Coulomb(1776), assume that the wall acts as a rigid body. This assumption results in failure being predicted by either monolithic overturning or base sliding mechanisms. However, the wall consists of individual members which have been created a three dimensional grid. This grid confines an fill mass which becomes part of the wall. The filled wall resists the earth pressure with the same mechanism of classical gravity walls. Because of the flexibility of the individual segment, it allows relative movement between the individual members within the wall. The three dimensional flexible grid leads to stress redistribution when the wall is subjected to external or fill loads. Due to the flexibility and the stress redistribution, the failure of segmental crib wall consists of not only overturing and base sliding but the local deformation and the failure between the segmental members. It has been researched in the field that due to this flexibility and load redistribution, serviceability failure of segmental crib walls is unlikely to be due to overturning or base sliding. Therefore, in this study, the relative displacement appearance of retaining wall due to variation of inclination is measured to examine this behavior characteristics. Also, the behavior characteristics of retaining walls by surcharge load, and location of acting point of retaining wall rear, and the displacement characteristics and deflections are estimated about the existence and nonexistence of Rear Stretcher performing an role in transmitting earth pressure of Header and Stretcher organizing retaining walls. This research focuses on the characteristics due to the behavior of retaining walls. This research focuses on the characteristics due to the behavior of retaining walls.

  • PDF

Segmental Deformity Correction after Balloon Kyphoplasty in the Osteoporotic Vertebral Compression Fracture

  • Lee, Jung-Hoon;Kwon, Jeong-Taik;Kim, Young-Baeg;Suk, Jong-Sik
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.5
    • /
    • pp.371-376
    • /
    • 2007
  • Objective : Balloon kyphoplasty can effectively relieve the symptomatic pain and correct the segmental deformity of osteoporotic vertebral compression fractures. While many articles have reported on the effectiveness of the procedure, there has not been any research on the factors affecting the deformity correction. Here, we evaluated both the relationship between postoperative pain relief and restoration of the vertebral height, and segmental kyphosis, as well as the various factors affecting segmental deformity correction after balloon kyphoplasty. Methods : Between January 2004 and December 2006, 137 patients (158 vertebral levels) underwent balloon kyphoplasty. We analyzed various factors such as the age and sex of the patient, preoperative compression ratio, kyphotic angle of compressed segment, injected PMMA volume, configuration of compression, preoperative bone mineral density (BMD) score, time interval between onset of symptom and the procedure, visual analogue scale (VAS) score for pain rating and surgery-related complications. Results : The mean postoperative VAS score improvement was $4.93{\pm}0.17$. The mean postoperative height restoration rate was $17.8{\pm}1.57%$ and the kyphotic angle reduction was $1.94{\pm}0.38^{\circ}$. However, there were no significant statistical correlations among VAS score improvement, height restoration rate, and kyphotic angle reduction. Among the various factors, the configuration of the compressed vertebral body (p=0.002) was related to the height restoration rate and the direction of the compression (p=0.006) was related with the kyphotic angle reduction. The preoperative compression ratio (p=0.023, p=0.006) and injected PMMA volume (p<0.001, p=0.035) affected both the height restoration and kyphotic angle reduction. Only the preoperative compression ratio was found to be as an independent affecting factor (95% CI : 1.064-5.068). Conclusion : The two major benefits of balloon kyphoplasty are immediate pain relief and local deformity correction, but segmental deformity correction achieved by balloon kyphoplasty does not result in additional pain relief. Among the factors that were shown to affect the segmental deformity correction, configuration of the compressed vertebral body, direction of the most compressed area, and preoperative compression ratio were not modifiable. However, careful preoperative consideration about the modifiable factor, the PMMA volume to inject, may contribute to the dynamic correction of the segmental deformity.

A Study on the Deformation Behavior of the Segmental Grid Retaining Wall Using Scaled Model Tests (조립식 격자 옹벽의 변형거동에 관한 모형실험 연구)

  • Bae, Woo-Seok;Kwon, Young-Cheul;Kim, Jong-Woo
    • Tunnel and Underground Space
    • /
    • v.17 no.5
    • /
    • pp.350-359
    • /
    • 2007
  • Most large cut slopes of open pit mines, roadways, and railways are steeply inclined and composed with rocks that do not contain soils. However, these rock slopes suffer both weathering and fragmentation. In the case of steep slopes, falling rock and collapse of a slope may often occur due to surface erosion. Cast-in place concrete and rubble work are the most widely used earth structure-based pressure supports that act as restraints against the collapse of the rock slope. In order to overcome the shortcomings of conventional retaining walls, a segmental grid retaining wall is being used with connects precasted segments to construct the wall. In this study, laboratory model test was conducted to estimate deformation behavior of segmental grid retaining wall with configuration of rear strecher, height and inclination of the wall. In order to examine the behavior characteristics of a segmental grid retaining wall, this research analyzes the aspects of spacial displacement through relative displacement according to change in the inclination of the wall. Also, the walls behavior according to the formation and status of the rear stretcher which serves the role of transferring the load from the header and the stretcher which make up the wall, the displacement of backfill materials in the wall, and the location of the maximum load were surveyed and the characteristics of displacement in the segmental grid retaining wall were observed. The test results of the segmental grid retaining wall showed that there was a sudden increase in failure load according to the decrease in the wall's height and the size of the in was greatly decreased. Furthermore, it revealed that with identical inclination and height, the structure of the rear stitcher did not greatly affect the starting point or size of maximum horizontal displacement, but rather had a stronger effect on the inclination of the wall.

Validation of Segmental Multi-Frequency Bioelectrical Impedance Analysis based on the Segmental Bioelectrical Impedance analysis in the Elderly Population (분절임피던스를 기준한 분절다주파수 생체임피던스의 일치도 분석)

  • Tang, Sae-Jo;Kim, Jang-Hee;Eom, Jin Jong;Eom, Sunho;Kim, Hakkyun;Kim, Chul-Hyun
    • Journal of Platform Technology
    • /
    • v.9 no.2
    • /
    • pp.38-45
    • /
    • 2021
  • A frequently used bioimpedance analytical method in Korea is the segmental multi-frequency BIA (SMF-BIA) method, but it is not directly determined at a segmented impedance. This study was to compare SMF-BIA determinations with direct segmented determinations for accuracy and appropriateness of segment parameters. This study is to compare the segment parameters, accuracy and appropriateness of the multi-frequency segmental bioimpedance analysis. To this end, 108 elderly individuals were measured. Segmented bioelectrical measurements obtained from a SMF-BIA (Inbody S10) at 50 kHz and measured with a phase sensitive single frequency device (SF-BIA, bia-101, RJL / akern systems) were compared. The significant difference (%) was demonstrated between single - and multiple frequency determinations of the right upper limb (R = 35.5 ± 6.2%, P < 0.001; Xc = 2.7 ± 7.6%, P < 0.01), left upper limb difference (R= 33. 9 ± 6.0%, P < 0.001; Xc = 2.8 ± 8.3%, P < 0.01), right lower limb difference (R = 18.6 ± 4.3%, P < 0.001; Xc = 25.8 ± 10.0%, P < 0.001), left lower limb difference (R = 18.0 ± 4.7%, P < 0.001; Xc = 31.8%). Of the results determined with the two BIA methods, the impedance measurements of the limbs and whole body showed a high correlation (RA: R = 0. 950, LA: R = 0. 949, RL: R = 0.899, LL: R = 0.88), and in the agreement test, the impedance values of the upper limbs and whole body also showed strong agreement (ICC > 0.9), but in the Xc, the correlation was weak. In conclusion, it was found that although bioimpedance devices had significantly different characteristics and inconsistent cross sectionally, there was a high population level agreement in the upper and lower extremities in determining segmental resistance value changes. But a large error was found on the trunk. Further studies were needed for reducing the error.

Assessment of Frictional Characteristic for the Segmental Retaining Wall Unit (보강토 옹벽 전면블록의 마찰특성 평가)

  • Kim Jin-Man;Cho Sam-Deok;Oh Se-Yong;Lee Dae-Young;Paik Young-Shik
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.1
    • /
    • pp.51-58
    • /
    • 2005
  • The use of geogrid for SRW systems and bridge abutment has increased rapidly over the past 10 years in Korea. The concept of segmental retaining walls and reinforced soil is very old and for example The Ziggurats of Babylonia(i.e. Tower of Babel) were built some 2,500 to 3,000 years ago using soil reinforcing methods very similar to those described in current design. Modern SRW(Semental Retaining Wall) units were introduced in 1960's as concrete crib retaining wall systems. In this paper, the friction properties between segmental concrete units and geogrid are investigated by performing various tests.

Ileal Atresia Secondary to Intrauterine Segmental Volvulus (태아 소장 부분염전에 의한 회장 무공증)

  • Park, Woo-Hyun;Park, Sang-Man;Choi, Soon-Ok
    • Advances in pediatric surgery
    • /
    • v.1 no.2
    • /
    • pp.177-180
    • /
    • 1995
  • A 2-day-old male (Premie, Large for gestational age(LGA), Intrauterine period(IUP) 33 weeks, birth weight 2,955 gram) was transferred with marked abdominal distention, bilious return via the orogastric tube, respiratory difficulty, and generalized edema (hydrops fetalis). He was born by cesarean section to a 36 year-old mother. Antenatal ultrasonogram at IUP 31 weeks demonstrated multiple dilated bowel loops suggestive of intestinal obstruction. There was no family history of cystic fibrosis. Simple abdominal films disclosed diffuse haziness and suspicious fine calcifications in the right lower quadrant. Barium enema demonstrated a microcolon. Sweat chloride test was not available in our institution. At laparotomy, there noted 1) a segmental volvulus of the small bowel with gangrenous change, associated with meconium peritonitis, 2) an atresia of the ileum at the base of the volvulus, and 3) the terminal ileum distal to the volvulus was narrow and impacted with rabbit pellets-like thick meconium. These findings appeared to be very similar to those of a complicated meconium ileus. In summary, the ileal atresia and meconium peritonitis seemed to be caused by antenatal segmental volvulus of the small intestine in a patient with probable meconeum ileus.

  • PDF