Experimental investigation of the effect of baffles on the efficiency improvement of irrigation sedimentation tank structures

  • Nouri, Alireza Zamani;Heydari, Mohammad Mehdi
    • Structural Engineering and Mechanics
    • /
    • v.63 no.4
    • /
    • pp.567-574
    • /
    • 2017
  • Sedimentation tanks are essential structures to filter the suspended sediments in the inlet flow which are constructed at the inlet of the basins forked from rivers and irrigation canals. The larger the constructed tank, the better the sedimentation process is conducted. However, the construction and dredging costs increase. In this regard, improving the performance and sedimentation efficiency seem necessary by alternative methods. One of these effective methods is using baffle plates. Most of the studies carried out in this field are on the use of these baffles in the primary and secondary sedimentation tanks. Hence, this study is carrier out with the objective of increasing the retention efficiency in the irrigation sedimentation tanks using baffles. To reach this goal, the experiments were carried out in a flume with length 8 meters, width 0.3 meters, and height 0.5 meters, considering a sedimentation tanks with a length of 3 meters, in three different inlet concentration, three flow rates and three Froude numbers. The baffles were mounted at the bottom of the tank and the effects of the angle, height and position in the tanks were investigated. The results showed that on average, employing the baffles increased the sedimentation efficiency 5 to 6% and the highest value was obtained for angle 60 with respect to the flow direction. According to the results of this study, the most favorable height and position of these baffles were obtained to be in 40% of the depth of the flow and 50% of the length of the sedimentation tank, respectively. Also, by increasing the number of baffles, the sedimentation efficiency decreased. Regarding the sedimentation regions in this case, more than 80% of the settled sediments were observed in the middle of the tank measured from the inlet.

Shape Optimization of Sedimentation Tank Using Response Surface Method (반응면기법을 이용한 침전조의 형상최적설계)

  • Kim, Hong-Min;Choi, Seung-Man;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.6 s.27
    • /
    • pp.55-61
    • /
    • 2004
  • A numerical procedure for optimizing the shape of three-dimensional sedimentation tank is presented to maximize its sedimentation efficiency. The response surface based optimization is used as an optimization technique with Reynolds-averaged Navier-Stokes analysis for multi-phase flow. Standard $k-{\epsilon}$ model is used as a turbulence closure. Three design variables such as, tank height to center feed wall diameter ratio, blockage ratio of center feed wall and angle of distributor are chosen as design variables. Sedimentation efficiency is defined as an objective function. Full-factorial method is used to determine the training points as a means of design of experiment. Sensitivity of each design variable on the objective function has been evaluated. And, optimal values of the design variables have been obtained.

A Study on the Removal of Grease and Oill in the Treatment Plant (하수처리장의 유지제거에 대한 연구)

  • 박재효
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 1981
  • During 20 days from November 4 to 28, 1980, the quantities of grease and oil, BOD (biological oxygen demand), COD (chemical oxygen demand), SS (suspended solid) were measured at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank in Chung Gye Chun sewage treatment plant. The results were as follows. 1. The average of grease and oil quantities were 251mg/l at Grit Chamber, 185mg/l at Primary Sedimentation Tank, 47mg/l at Secondary Sedimentation Tank. 2. In the secondary treatment for the removal of grease and oil, the removed quantities of grease and oil were increased according to increasing the quantities of influent grease and oil. The regression equation were as follows G.O.removed=0.731 G.O. influent+3.235 (r=0.887) 3. The average of grease and oil removal rate was 76.4% and the standard deviation of grease and oil removal rate daily was 10.6%. 4. G.O. (grease and oil) and BOD, COD, SS showed significant correlationship at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank. (P<0.05). 5. In the secondary treatment, effluent grease & oil and other parameters were analyzed by means of Stepwise multiple regression. Multple regression equation for estimates of effluent grease and oil were as follows. $GO_E=-9.1637+2.0380 SS_E+0.068 SS_I$ (r=0.778) 6. The correlative parameters for the effluent grease and oil seem to be the influent SS and the effluent SS. 7. It was estimated that the removal of grease and oil would be improved by means of improvement of suspended solids removal efficiency but it is necessary to inquire further into the study.

  • PDF

Advanced Treatment Efficiency of Biological String Media and Oenanthe javanica for Effluent Quality Improvement in the Sedimentation Model Plant (하수의 최종 유출수 수질 개선을 위한 침전조 모형실험에 적용한 끈상 미생물접촉재와 미나리의 고도처리효율에 관한 연구)

  • Bae Joon-Sam;Lee Sang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.440-447
    • /
    • 2006
  • This study was aimed at the improvement of the effluent quality of municipal wastewater treatment plant by Oenanthe javanica and Bio-string media. The results were compared with conventional sedimentation tank and pilot sedimentation plant. In this study BOD as organic pollutants, SS, Nitrogen and Phosphorus were tested to evaluate the removal efficiencies for the advanced treatment. The result were as follow: in the Pilot Plant experiment, Tank 2 was fairly high removal efficiency as compared with Tank 1. The removal efficiency of BOD and SS in Tank 2 were as a range of $7.9%{\sim}38.8%,\;14.3%{\sim}60.0%$ and the removal efficiency of T-N, T-P were a range of $9.6%{\sim}31.5%,\;33.0%{\sim}80.0%$ respectively. The removal efficiency of T-P and SS were much higher than BOB and T-N.

  • PDF

Particle Removal in a Rainwater Storage Tank, and Suggestions for Operation & Design (빗물저장조에서 입자의 제거특성 및 운전과 설계시 고려사항)

  • Mun, Jungsoo;Yoo, Hyoungkeun;Han, Mooyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.131-138
    • /
    • 2007
  • A rainwater utilization facility consists of its catchment area, treatment facility, storage tank, supply facility and pipes in general. The rainwater storage tank which occupies the largest area of the facility has been usually considered quantitatively for determining the storage capacity. Hence, there is little information on water quality improvement by sedimentation in a rainwater storage tank in operation. In this study, we measured the rainwater quality in a rainwater storage tank in operation during late spring and summer, and showed water quality improvement of turbidity removal of 25~46% by sedimentation in a rainwater storage tank under a fixed water level without inflow and outflow after runoff ceased. It is necessary to have a considerable distance between the inlet and outlet of the tank and, if possible, it is recommended that the design should allow for an effective water depth of over 3 m and supply rainwater near the water surface. The operation method which increases the retention time by stopping rainwater supply for insuring low turbidity is recommended when the turbidity of rainwater runoff is high. And also more efficient operation and maintenance of the rainwater utilization facility is expected through the tailored design and operation of the facility considering particle removal and behavior.

Ensuring Stability in Accordance with the Secondary sedimentation tank Surface Loading rate Increase (장방향 이차침전지에서 이중정류벽 설치를 통한 침강속도 증대에 따른안정성 확보 분석)

  • Choi, Dongkyu;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.357-362
    • /
    • 2016
  • Improvement of the solid-liquid separation efficiency in the secondary sedimentation tank of the biological treatment process, is known to be increasing effectiveness of the overall system operation. Sewage treatment plant effluent SS is composed of most organic substances. In order to reduce the SS component in the secondary sedimentation tank discharge, fine SS components constituting the heterogeneous should be increased by its own aggregation (self flocculation), so that can be deleted through their precipitation. So, it is improved through using the installation of double rectification wall in this secondary tank. In case, sewage is rapidly increased due to the daily change of the influent water, it was confirmed that suspended solids caused by the impact load are processed stably. Therefore, there is a need for a facility installation which can be its own aggregation for reduction suspended solids in secondary sedimentation tank.

Removal of NOM Using Biological Rope Media Sedimentation Tank (로프형 미생물 담체 침전조를 이용한 상수원수중의 NOM 제거)

  • 심상준;강연석;김우식;박대원
    • KSBB Journal
    • /
    • v.16 no.4
    • /
    • pp.332-336
    • /
    • 2001
  • This paper is intended as an application of the biological rope media sedimentation tank using biodegradability of BAC(Biological activated carbon) to the drinking water treatment system for the removal of NOM. The removal of DOC(Dissolved organic carbon), UV absorbance(UV$\_$254/), and turbidity were evaluated under various operation condition of a biological rope media sedimentation tank such as raw water-media process (Media 1), ozonation-media process (Media 2), and ozonation-coagulation/sedimentation-media process (Media 3). The raw water had DOC concentration of 1.3∼3.4 mg/L, UV$\_$254/ of 0.027∼0.039 cm$\^$-1/, and turbidity of 0.3∼4.5 NTU, respectively. The average DOC concentration were 2.2 mg/L in media 1, 1.8 mg/L in media 2, and 1.3 mg/l in media 3 from raw water, respectively. On the other hand, the DOC concentration in conventional sedimentation tank was 1.5 mg/l. Higher removal of the DOC was noted in media 3 than media 1 and media 2. The UV$\_$254/ of the treated water were 0.037 cm$\^$-1/ in media 1, 0.027 cm$\^$-1/ in media 2, and 0.014 cm$\^$-1/ in media 3 from raw water, respectively The UV$\_$254/ in conventional sedimentation tank was 0.014 cm$\^$-1/ which is similar to that of media 3. Average turbidity of the treated water was 1.1 NTU in media 1, 0.9 NTU in media 2, and 0.5 NTU in media 3, respectively. It is expected that the biological rope media sedimentation tank is a good alternative over the conventional sedimentation process from these results.

  • PDF

Performance of Advanced Sewage Treatment Process with Waste Oyster Shell Media in Rural Area (폐굴껍질 담체를 이용한 마을하수고도처리공정의 성능평가)

  • Lim, Bong-Su;Yang, Yan-Hao
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.30-36
    • /
    • 2006
  • This study was carried out to evaluate the performance of Modified Ludzsck Etinger (MLE) process with waste oyster shell media in aerobic tank. Influent flow was 36 L/d and the order of reactor was anoxic, aerobic and sedimentation tank and unit hydraulic retention time was 2 hr, 6 hr and 4 hr, respectively. Sludge recycling rate in sedimentation tank and internal recycling rate were 100%. Media fill rate in aerobic tank was 5%, 10% and 17% and fluid MLSS concentration in aerobic tank was 3000~4000 mg/L. Average TCOD removal rate was 91~93%, TBOD 92~96%, SS 95~96% and when media fill rate was 10% or more, in organic compound removal it could satisfy with wastewater discharge standard. Average total nitrogen removal rate was 70~76% and average total phosphorous removal rate was 58~65%. With media fill rate increasing, total phosphorous average removal rate also increased. For it was that released calcium ion from waste oyster shell reacted with soluble phosphorous. From these experiment results, the MLE process using waste oyster shell as media is a practical method for advanced sewage treatment in rural area.

The Evaluation of White Water Sedimentation Efficiency in Settling Tank by the Addition of Flocculents (응집제 첨가에 의한 침전조의 백수침전 효율 평가)

  • Kim Hyoung Jin;An Jung Song;Yoo Sung Ho
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.4 s.107
    • /
    • pp.67-76
    • /
    • 2004
  • Because paper industry spends lots amount of water, the recycling of water is very important in economical as well as environmental aspects. In order to optimize the process water recycling system, the efficiency of unit operation for water circulation, such as save-all system, CDS and settling tank, plays an important role in. In this study, the sedimentation efficiency of process water was evaluated by SS measurement with the different amounts of flocculent addition. 3 different kinds of process water were collected from fine paper mill, and applied in laboratory sedimentation equipment for the measurement of settling efficiency of SS materials. The addition amounts of alum and PAC were resulted in optimum efficiency of sediments in the condition of 100 ppm of alum and 500 ppm of PAC respectively. In the comparison of sedimentation efficiency between alum and PAC, alum showed more economical and efficient results. The SS of spill water and the particle size of suspended materials treated by alum flocculents were below 50 ppm and about 1 $\mu$m. It would be considered that the spill water can be substituted to superclear water grade.