• Title/Summary/Keyword: Sedimentation Efficiency

Search Result 202, Processing Time 0.028 seconds

Development and Lab-scale Plant Study of Coagulation Sedimentation Module using Cyclone (선회류를 이용한 응집침전모듈의 개발 및 실증 연구)

  • Moon, Jinyoung;Cho, Young-Gun;Song, Seung-Jun;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3336-3344
    • /
    • 2014
  • The purpose of this study is small scale coagulation module is developed and demonstrated through a lab-scale test. Recent as a sewage treatment rate increases, have heightened the interest in the necessity on the nonpoint source and developing a small processing unit has been increased. Coagulation sedimentation module in this study is additional growth of floc through swirling in the outside zone, reduction of microstructure floc number and the internal settling zone through vertical/level flow complex sedimentation method after the coagulation process precipitation method as an effective high separation efficiency can be divided was also assessed. Coagulation sedimentation module can increase the load factor was 4.4 times compared to conventional clarifier base on the same volume and surface area through vertical/level flow. In this study, this process was selected formation and maintenance of swirling and uniform flow distribution in the internal settling zone as an important design factor, to derive its FLUENT was used to characteristics of the flow model. Through the simulation of swirling, influent velocity, dimensions of external basin, hopper depth of bottom cone was determined and through analysis of velocity distribution, flow distribution detailed specifications are derived like as diameter and number of effluent hole. Lab-scale($120{\ell}/hr$) test results, influent of 300~800 NTU to less than 10 NTU without polymer feeding was able to operate in the 20minutes retention time(surface loading rate $37.3m^3/m^2$-day), and through analysis FLUENT the possibility of using design parameters were derived.

Solid Separation and Flotation Characteristics of Livestock Wastewater Using DAF Process (DAF 공정을 이용한 축산폐수의 고형물 분리와 부상특성)

  • Kang, Byong-Jun;Yoo, Seung-Joon;Lee, Se-il;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.359-366
    • /
    • 2008
  • The series of experiments under the various conditions were carried out to evaluate the feasibility of dissolved air flotation (DAF) as an alternative of conventional gravity sedimentation (CGS) and to investigate the decrease of the loadings following to biological wastewater treatment processes in livestock wastewater system. On the basis of the experiment result between CGS and DAF processes, for the other water quality criteria as well as suspended solid the removal efficiency of DAF process was about 20~25 % better than CGS process on average. In addition, the particle removal efficiency of DAF process became higher in proportion as the increase of air to solid (A/S) ratio and the general wastewater treatment efficiency of DAF process was enough to meet the requirement of loading decrease to following biological process even at low A/S ratio range. Though DAF process is widely known as an solid separation unit, there was not the notable relationship between particle separation efficiency and several pollutant removal efficiencies like $COD_{Cr}$ and nutrients (T-N, T-P). Assume that the $COD_{Cr}$ was removed as the fraction of particle separation in this experiment, the removal efficiency of T-N and T-P were sensitive to removal efficiency of $COD_{Cr}$, especially.

A study on new treatment chemical for leather wastewater; I. Development of new organic coagulant (새로운 피혁폐수 처리제에 관한 연구; I. 새로운 유기 응결제의 개발)

  • Jung, Maeng-Joon;Lee, Chul-Jae;Han, Sung-Wook
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.4
    • /
    • pp.323-330
    • /
    • 2006
  • As the interest in environmental pollution resulting from recent industrial development is converging, wastewater treatment problem of dying processing is one of important pending issue. Usually, flow mediation earth and settling pond etc. of processing plant to handle water or wastewater. Mediation is the wastewater that flowed past settling pond than material of heavy particles, water weight colloid particles that big solids are removed but are suspensibility material settlement exclusion impossible. So, we need flocculation and coagulation action to remove materials from this colloid state. For flocculation and coagulation action chemical agents to add back, addition of chemical agents forms floc of could settle size. That is, shorten the sedimentation time and quality of processing water because promoting sedimentation doing to do fines or suspended solids and colloid can materials large size and also, flocculation to annex efficiency of filtration augment. Therefore, I executed this research to prove that improving organic matter and chromaticity of treated water of processing epochally using organic coagulant informed positive ion co-polymerization superior in color wastewater through this research.

  • PDF

USING REMOTE SENSING TO DETECT THE COASTLINE CHANGE FOR MANGROVE REPLANTATION AT BAN LAEM SING, CHAO PHRAYA RIVERMOUTH, IN THE GULF OF THAILAND

  • Siripong, Absornsuda
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.535-538
    • /
    • 2006
  • The coastline of the Choa Phraya Rivermouth in the Upper Gulf of Thailand has been changed drastically. The western side especially at Ban Laem Sing was eroded for 400 meter in 26 years or with the rate of 15 meter per year on the average. The Metropolitan Electricity Authority has granted five years research project to us to study the efficiency of the electric pole fence as a mean to reduce the wave force and increase sedimentation rate inside for mangrove replantation. If the method works efficiently, it will be used to reclaim the coastal land loss in other areas in Thailand. The project was done since 2005 after the fence was constructed completely in October 2005. The oceanographic surveys were conducted before and after the construction in northeast monsoon season to study the impact of physical oceanographic forces on the coastline change. The sedimentation rates were measured each month. It is rather low about 2 cm/month. The subsiding rate from the load of deltaic sediment and groundwater withdraw using boring data is about 30 mm/year. The cumulative sinking rate is 55.8 cm from 1978 to 1995. We have tried to design the method of mangrove plantation in this area. The remote sensing data such as LANDSAT and aerial photos from 1987 to 2002 for 15 years were used to compute the rate of coastline change at each 50 m section along the western side of the rivermouth.

  • PDF

Evaluation of Hydraulic Characteristics Influenced by Different Deflector Baffles in the Sedimentation Basin with Inclined Plate Settler (경사판 침전지에서 저류벽의 설치위치에 따른 수리학적 특성의 평가)

  • Yu, Myong-Jin;Kim, Hyun-Chul;Ryu, Seong-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.40-45
    • /
    • 2005
  • Sedimentation is one of the most common and important units in conventional water treatment plant. Structure such as various baffle walls and inclined plate settler may be obstacles to the horizontal flow when it is poorly designed. Therefore, the effects of these structures on characteristics of hydraulic flow must be evaluated to improve the settling efficiency of the floc. The hydraulic characteristic of the two sedimentations at Y water treatment plant (YWTP), which have different deflector baffles inside the settling basin, were investigated by tracer (fluoride) test. The inclined plate settler installed inside settling basin caused an undesirable impact on horizontal flow and produced dead zone. Solid baffle wall under the plate settler could help to minimize the formation of density currents and flow short circuiting. NaF used as a tracer was recovered more than 90% at investigated all basins. Morill index ($t_{90}/t_{10}$), Modal index ($t_p/T-HRT$) and short-circuiting index ($[M-HRT-t_p]/M-HRT$) were determined from tracer test results performed at YWTP. Those indices ranged 2.95~3.02, 0.40~0.53 and 0.32~0.46, respectively.

Degradation Characteristics of Non-biodegradable Matters using Pre-Coagulation and Fenton Oxidation Process in Livestock Wastewater (전응집 및 Fenton 산화공정을 이용한 축산폐수의 난분해성물질 제거특성에 관한 연구)

  • Cho, Chang-Woo;Kim, Boung-Young;Chae, Soo-Choen;Kim, Sun-Ae;Chung, Paul-Gene
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.66-73
    • /
    • 2006
  • The purpose of this study was done to evaluate degradation characteristics of non-biodegradable organic matters including aromatic compounds in livestock wastewater using CFZ process. The CFZ process is consisted of coagulation/sedimentation, Fenton oxidation and zeolite adsoption process. degradation charateristics of each treatment water including livestock wastewater were analyzed by UV scanning, FT-IR and GC/MS. After coagulation/sedimentation process as 1st treatment, non-biodegradable matters remained after 1st treatment were removed by using OH radical produced in Fenton oxidation process. As a result of treatment using these processes, NBDCOD removal efficiency was over 90%. Increase of $E_2/E_3$ ratio (absorbance at 250 and 365 nm) in each treatment water means that aromaticity of livestock wastewater decreased. In case of GC/MS, most aromatics or polynuclear aromatics like benzene, phenol and scatol in livestock wastewater almost wasn't detected after oxidation using OH radical.

Substitutability of coagulation process by pre-treatment of coagulation·flotation using natural algae coagulant (천연조류제거제를 활용한 응집·부상 전처리공정의 기존 응집공정 대체 가능성)

  • Jang, Yeo-Ju;Jung, Jin-Hong;Lim, Hyun-Man;Chang, Hyang-Youn;Kim, Weon-Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.39-50
    • /
    • 2017
  • In the coagulation/sedimentation (C/S) process of the water treatment process, the inflow of massive algal bloom causes many problems including fouling of filter media. This study was conducted to find out the way to remove the algae's harmful effects by addition of pre-treatment prior to C/S process. Many Jar-tests were conducted such as (1) ACF (Algae Coagulation Flotation) process using natural algae coagulant (Water $Health^{(R)}$), (2) ACF + C/S process and (3) C/S process with a variety of conditions using cultured algae. The average values of turbidity were (1) 0.42 NTU for ACF process, (2) 0.13 NTU for ACF + C/S process and (3) 0.25 NTU for C/S process. It was shown that the treatment efficiency of ACF process could get low turbidity results, and ACF + C/S process could achieve more efficient results than those of C/S process. Any negative effects of ACF process to the efficiency of C/S process were not observed in ACF + C/S process. In order to reduce the unfavorable effects of algae, it was found out that the introduction of ACF process in the forms of (1) ACF or (2) ACF + C/S could be one of the effective and alternative solutions.

Preparation and Evaluation of Ketoprofen-incorporated Solid Lipid Nanoparticles (SLN) (케토프로펜을 함유하는 고형 지질 나노파티클의 제조 및 평가)

  • Baek, Myoung-Ki;Lee, Sang-Young;Jee, Ung-Kil
    • Journal of Pharmaceutical Investigation
    • /
    • v.26 no.4
    • /
    • pp.245-256
    • /
    • 1996
  • Solid lipid nanoparticles (SLN) have been developed as a new drug delivery system. Although many particulate drug carriers, such as microsphere, liposome, niosome, emulsion, etc. have been introduced, they have some disadvantage; low efficiency of incorporation and stability, lack of reproducibility, and so on. Meanwhile, SLN as a new drug delivery system is known to entrap rugs with a high efficiency and a good reproducibility. Moreover, small size SLN can circulate in blood for a prolonged time. Although many preparation methods were introduced, microfluidization method is recommended to be the most useful. This study was attempted to prepare and evaluate ketoprofen-incorporated SLNs (keto-SLN), which were prepared by two methods, ultrasonication and microfluidization. Keto-SLN was evaluated by measurement of particle size and zeta potential, efficacy of entrapment, sedimentation volume, in virto release pattern. The mean particle size was about $0.1\;{\mu}m$, and the size was dependent on the type and the amount of emulsifier. Zeta potential was negative, $-9{\sim}-13mV$ and entrapment efficacy was very high and stability was good for at least 60 days in the respect of particle size and sedimentation volume ratio. Analgesic effect was also determined as well as pharmacokinetic parameters. The former was comparable to that of that of ketoprofen loaded suspension (keto-sus) and the latter revealed that consistent with the delayed release of keto-SLN. $T_{max}$ was longer than keto-sus. Therefore, keto-SLN was favourable dosage forms in the field of drug delivery system such as anti-cancer, analgesics and anti-inflammatory agents.

  • PDF

Application of Horizontal Flow Fins Inclined Plate for Sedimentation Efficiencies Improvement in River Water with High Turbidity (고탁도 원수의 침전효율 증대를 위한 수평류식 핀 경사판 적용에 관한 연구)

  • Choi, Jung-Su;Jin, Oh-Suk;Joo, Hyun-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.644-650
    • /
    • 2012
  • The purpose of this study is to evaluate the applicability of Horizontal Flow Fins Inclined Plate (HFIP) for the removal of high-turbidity raw water in water treatment plant. As an experimental result, treated water quality and removal efficiency were 0.34 NTU and 90.45% by the application of HFIP for low-turbidity raw water and for the high-turbidity influent resulted 0.75 NTU and 97.27% in removal efficiency. In view of stability for discharge water NTU, the standard deviation were found as 0.12 NTU for low-turbidity and 0.75 NTU for high-turbidity raw water indicating low fluctuations. Result of flow analysis using CFD (Computational Fluid Dynamic) that the addition of HFIP improves the turbidity treatment followed by the stabilization of flow velocity distribution and increases in settling velocity.

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.