• Title/Summary/Keyword: Sectional image

Search Result 339, Processing Time 0.026 seconds

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.

High Speed Direct Bonding of Silicon Wafer Using Atmospheric Pressure Plasma (상압 플라즈마를 이용한 고속 실리콘 웨이퍼 직접접합 공정)

  • Cha, Yong-Won;Park, Sang-Su;Shin, Ho-Jun;Kim, Yong Taek;Lee, Jung Hoon;Suh, Il Woong;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.3
    • /
    • pp.31-38
    • /
    • 2015
  • In order to achieve a high speed and high quality silicon wafer bonding, the room-temperature direct bonding using atmospheric pressure plasma and sprayed water vapor was developed. Effects of different plasma fabrication parameters, such as flow rate of $N_2$ gas, flow rate of CDA (clear dry air), gap between the plasma head and wafer surface, and plasma applied voltage, on plasma activation were investigated using the measurements of the contact angle. Influences of the annealing temperature and the annealing time on bonding strength were also investigated. The bonding strength of the bonded wafers was measured using a crack opening method. The optimized condition for the highest bonding strength was an annealing temperature of $400^{\circ}C$ and an annealing time of 2 hours. For the plasma activation conditions, the highest bonding strength was achieved at the plasma scan speed of 30 mm/sec and the number of plasma treatment of 4 times. After optimization of the plasma activation conditions and annealing conditions, the direct bonding of the silicon wafers was performed. The infrared transmission image and the cross sectional image of bonded interface indicated that there is no void and defects on the bonded wafers. The bonded wafer exhibited a bonding strength of average $2.3J/m^2$.

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

Cosmetic Outcomes and Quality of Life in Thai Women Post Breast Conserving Therapy for Breast Cancer

  • Thanarpan, Peerawong;Somrit, Mahattanobon;Rungarun, Jiratrachu;Paytai, Rordlamool;Duangjai, Sangtawan;Chanon, Kongkamol;Puttisak, Puttawibul
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.11
    • /
    • pp.4685-4690
    • /
    • 2015
  • Purpose: To evaluate the correlation between cosmetic outcome (CO), body image, and quality of life in post breast-conserving therapy (BCT) women. Materials and Methods: This cross-sectional study concerned one-year post-completed BCT Thai women. The data included subjective and objective CO with a questionnaire covering demographic and clinical data, anti-hormonal treatment status, Eastern Cooperative Oncology Group (ECOG) performance status, Self-Reported Cosmetic Outcomes (SRCO), Self-Reported Breast Symmetry (SRBS), Body Image Scale (BIS), and the Functional Assessment of Cancer Therapy with Breast Cancer subscale (FACT-B). Participants had breast photographs taken for the evaluation of objective cosmetic outcome (OCO) after breast cancer conservation treatment. The relationship between CO and FACT-B was tested using Spearman's rank correlation Results: A total 127 participants volunteered for the study. The participant characteristics were age 52(${\pm}9$), Buddhist 87%, married 65%, body mass index 25.0(${\pm}4.6$), breast cup size A-C 91%, college educated 60%, employed 66%, ECOG 0-1 95%, tumor size less than or equal to 2 cm 55%, no lymph node metastasis 98%, and taking tamoxifen 57%. Two percent of the participants regretted their decision to undergo BCT. The SRCO was excellent in 2%, good in 68%, fair in 30%, and poor in 0%. For SRBS, rates were 17%, 58%, 24% and 1% for excellent, good, fair and poor cosmetic outcomes, respectively. The BCCT scores were excellent 24%, good 39%, fair 32%, and poor 6%. The median total QOL score of the participants was 130 (93-144). There was no significant correlation between CO and FACT-B scores. Conclusions: The significance of CO for FACT-B in Thai women with breast cancer could not be assessed in detail because of a very low level of correlation. The results may be due to the effects of cultural background.

Assessment of Early Dental Caries by Using Optical Coherence Tomography (Optical Coherence Tomography를 이용한 초기 치아우식 검사)

  • Min, Ji-Hyun
    • Journal of dental hygiene science
    • /
    • v.16 no.4
    • /
    • pp.257-262
    • /
    • 2016
  • The purpose of this study was to assess the correlation between integrated mineral loss (volume % mineral${\times}{\mu}m$, ${\Delta}Z_{TMR}$) determined using transverse microradiography (TMR) and integrated reflectivity ($dB{\times}{\mu}m$, ${\Delta}R_{OCT}$) determined using optical coherence tomography (OCT) for detecting early dental caries with lesion depth more than $200{\mu}m$. Sixty tooth specimens were made from sound bovine teeth. They were immersed in a demineralized solution for 20, 30, and 40 days. The ${\Delta}R_{OCT}$ was obtained from the cross-sectional OCT image. The ${\Delta}Z_{TMR}$ was obtained from the TMR image. The correlation between ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ was examined using Pearson correlation. The Bland-Altman plot was constructed using the ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ values. A significant correlation between ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ was confirmed (r=0.491, p=0.003). Moreover, most of the difference between ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ was included in the error section of the Bland-Altman plot. Therefore, OCT could be used as a substitute for TMR when analyzing mineral loss in early dental caries.

Quality of Life and Psychological Well-Being of Breast Cancer Survivors in Jordan

  • Abu-Helalah, Munir;Al-Hanaqta, Motasem;Alshraideh, Hussam;Abdulbaqi, Nada;Hijazeen, Jameel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5927-5936
    • /
    • 2014
  • Introduction: Breast cancer is the most common cancer among Jordanians. Breast cancer patients suffer from several negative consequences after treatment and these include pain, fatigue, sexual problems, appearance and body image concerns, with psychological dysfunction. This could affect the patient quality of life and psychological well-being. To the best of our knowledge, there is no published quantitative data on the quality of life and psychological well-being of breast cancer patients in Jordan. The objective of this study was to obtain such data and assess predictors with calculated scores. Methods: In this cross-sectional study conducted among breast cancer patients in Jordan diagnosed in 2009 and 2010, assessment was performed using the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30), the Breast Module (QLQ-BR23) and the Hospital Anxiety and Depression Scale (HADS). Clinical, demographic and psychosocial indicators that could predict patient quality of life scores were collected. Results: The number of patients interviewed was 236 (mean age=$50.7{\pm}10.7$ years). The mean Global Health score for the QLQ-C30 was $63.7{\pm}20.2$ SD. Among functional scales, "social functioning" scored the highest ($mean=78.1{\pm}28.6$ SD), whereas "emotional functioning" scored the lowest ($mean=59.0{\pm}SD\;33.5$). For the QLQ-BR23, the worst scores within the functional scales were for "body image" ($mean=52.1{\pm}36.8$ SD) and "future perspective" ($mean=52.9{\pm}38.5$ SD). The worst symptom was "upset by hair loss" ($mean=69.8{\pm}43.0$). The mean HADS scores was $18.{\pm}9.0$ SD. Out of study participants, 53% scored abnormal on the anxiety scale and 45% on the depression scale. Severe depression and severe anxiety were detected among 8% and 14% of study participants, respectively. Statistically significant predictors for individual scores were similar to those reported in published studies, such as the presence of recurrence since baseline, family history of cancer, low educational status, current social problems, extent of the disease, presence of financial difficulties, and employment status. Conclusions and Recommendations: Breast cancer survivors in Jordan have overall good quality of life scores when compared with patients from Western countries. However, their psychological wellbeing is more impaired. There is an urgent need for psychosocial support programs and psychological screening and consultation for breast cancer patients at hospitals of the Ministry of Health in Jordan.

Numerical Analysis of Three-Dimensional Magnetic Resonance Current Density Imaging (MRCDI) (3차원 자기공명 전류밀도 영상법의 수치적 해석)

  • B.I. Lee;S.H. Oh;E.J. Woo;G. Khang;S.Y. Lee;M.H. Cho;O. Kwon;J.R. Yoon;J.K. Seo
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.269-279
    • /
    • 2002
  • When we inject a current into an electrically conducting subject such as a human body, voltage and current density distributions are formed inside the subject. The current density within the subject and injection current in the lead wires generate a magnetic field. This magnetic flux density within the subject distorts phase of spin-echo magnetic resonance images. In Magnetic Resonance Current Density Imaging (MRCDI) technique, we obtain internal magnetic flux density images and produce current density images from $\bigtriangledown{\times}B/\mu_\theta$. This internal information is used in Magnetic Resonance Electrical Impedance Tomography (MREIT) where we try to reconstruct a cross-sectional resistivity image of a subject. This paper describes numerical techniques of computing voltage. current density, and magnetic flux density within a subject due to an injection current. We use the Finite Element Method (FEM) and Biot-Savart law to calculate these variables from three-dimensional models with different internal resistivity distributions. The numerical analysis techniques described in this paper are used in the design of MRCDI experiments and also image reconstruction a1gorithms for MREIT.

The Influence of Microwave Sintering Process on the Adaptation of CAD/CAM Zirconia Core (마이크로 웨이브 소결 과정이 CAD/CAM 지르코니아 코아의 적합도에 미치는 영향)

  • Kim, Keun Bae;Kim, Jee Hwan;Lee, Keun-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.95-107
    • /
    • 2009
  • The purpose of this research was to examine the fitness of zirconia cores that were made by different sintering methods; generic electricity furnace and microwave furnace. Firstly, 12 cores for each group were made by using each different sintering process and attached them to a metal die with silicon. The internal and marginal gap of sintered zirconia was measured by using Skyscan 1076 micro-CT, then it was reorganized by CT-An software. To each samples, we extracted B-L image, M-D image of cutting side, and cross-sectional side of tooth long axis and calculated the mean value of marginal, axial, and occlusal gap each side. Results: 1. The mean marginal gap of sintered zirconia was $36.20{\mu}m$ for EVE, $47.67{\mu}m$ for LAV, $52.47{\mu}m$ for DEN, and $54.63{\mu}m$ for CER. 2. For the axial wall, the research showed the largest value of $63.49{\mu}m$ for EVE, but there were no statistical significance. 3. In related to the occlusal internal measurement, DEN showed the smallest value ($77.06{\mu}m$), EVE and CER showed significantly high value. From this study, it is suggested that CAD/CAM zirconia core which was made in the process of microwave sintering has clinically acceptable values in marginal and internal gap.

Eating Behaviors, Perception of Body Image, Hematological Indices and Nutrient Intake of Adolescent Female Athletes in Incheon (인천지역 청소년 여자 운동선수의 식행동, 체형에 관한 인식 및 영양상태평가)

  • 정선희;성현이;김순기;김광회;조미혜;장경자
    • Korean Journal of Community Nutrition
    • /
    • v.8 no.6
    • /
    • pp.951-963
    • /
    • 2003
  • The purpose of this study was to investigate the eating behaviors, the self-perception of body images, the hematological indices and the nutrient intake of adolescent female athletes in Incheon. The subjects were 112 female athletes(track and fleld: n=32, target shooting: n=27, fencing n=29, swimming: n=14, badminton: n=10) from middle and high schools in Incheon. This cross-sectional study was conducted by means of a sol(-administered questionnaire. Fasting blood samples were obtained and analyzed for hemoglobin (Hb), hematocrit (Hct), ferritin, serum iron, mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration(MCHC), unsaturated iron binding capacity (UIBC), total iron binding capacity (TIBC) and transferrin saturation (TS). Nutrient intakes obtained by means of the 3 day-recall method were analyzed using the Computer Aided Nutritional Analysis Program. Statistical analysis was conducted using the SPSS 10.0 program. Most of the female athletes had dietary problems such as eating unbalanced meals, skipping meals, and preferences for processed foods. More than 60% of the female athletes skipped breakfast. As for perception of their body images, track and field athletes in particular, controlled their weights significantly better than the other athletes (p<0.05). With regard to their physical exertion during exercise, 56.3% of the swimmers and 31.3% of the track and field athletes answered “very hard”, which was a significant difference (p< 0.001). More than 80% of the female athletes experienced vertigo during exercise (p< 0.01). Also more than 50% of the female athletes, with the exception of the badminton players, had experienced irregular menstruation (p<0.05). The average serum iron levels (p<0.05), the serum ferritin levels (p<0.05) and TS (p<0.05) of the track and field athletes was significantly lower as compared to that of the other athletes. The nutrient intakes of the female athletes, with the exception of Vitamin B$_{6}$, niacin and phosphorus were lower than the Korean Recommended Daily Allowances (RDA). In particular, the calcium and iron intakes of the female athletes were under 50% of the Korean RDA. Therefore, proper nutritional education and supplementation are required for female athletes to encourage desirable eating habits, as well as to improve their nutritional status and exercise performances.s.

Fiber Classification and Detection Technique Proposed for Applying on the PVA-ECC Sectional Image (PVA-ECC단면 이미지의 섬유 분류 및 검출 기법)

  • Kim, Yun-Yong;Lee, Bang-Yeon;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.4
    • /
    • pp.513-522
    • /
    • 2008
  • The fiber dispersion performance in fiber-reinforced cementitious composites is a crucial factor with respect to achieving desired mechanical performance. However, evaluation of the fiber dispersion performance in the composite PVA-ECC (Polyvinyl alcohol-Engineered Cementitious Composite) is extremely challenging because of the low contrast of PVA fibers with the cement-based matrix. In the present work, an enhanced fiber detection technique is developed and demonstrated. Using a fluorescence technique on the PVA-ECC, PVA fibers are observed as green dots in the cross-section of the composite. After capturing the fluorescence image with a Charged Couple Device (CCD) camera through a microscope. The fibers are more accurately detected by employing a series of process based on a categorization, watershed segmentation, and morphological reconstruction.