• Title/Summary/Keyword: Section inspection

Search Result 343, Processing Time 0.039 seconds

A study on the improvement for landscape design, construction, and management (계측.설계, 시공, 관리에 대한 법.제도의 개선에 관한 연구 -조경을 중심으로-)

  • 정하광
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.3
    • /
    • pp.29-47
    • /
    • 1995
  • The purpose of this study is to improve the laws for landscape planning & design, construction, and management. The results obtained in this study are as follows : 1. In a section of landscape planning and design, it is needed to intensity the preliminary inspection for the landscape planning and design. 2. In a section of landscape construction, it is needed to intensify the superintendence and the penal regulation for the landscape construction. 3. In a section of landscape management, it is needed to provide the obligatory regulations and to intensify the penal regulation for the landscape management.

  • PDF

Evaluation of Seismic Strengthening Approach at the Boundary Elements of RC Walls using Prestressed Wire Rope Units (프리스트레스트 와이어로프를 사용한 RC 벽체의 단부 경계요소 내진보강 평가)

  • Kwon, Hyuck-Jin;Yang, Keun-Hyeok;Byun, Hang-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.56-63
    • /
    • 2018
  • The present study examined the reversal cyclic flexural behavior of walls with jacket section approach for seismic strengthening through forming the boundary elements at both ends of the wall. The prestressed wire ropes were used for the lateral reinforcement to confine the boundary element of the wall. The main parameter investigated was the height of the jacket section for strengthening. The limit height of the strengthening jacket section was determined by comparing the moment distributions between the existing and strengthened walls. Test results showed that the examined jacket section approach was significantly effective in enhancing the flexural resistance of walls, indicating 46% higher stiffness at peak strength and 210% greater work damage indicator, compared with the flexural performance of the unstrengthened wall. The ductility of the strengthened walls was insignificantly affected by the height of the jacket section when the height is greater than twice the wall length. The flexural capacity of the strengthened walls was 22% higher than the predictions obtained using the equivalent stress block specified in ACI 318-14.

Static Aanlysis of Curved box Girder Bridge with Variable Cross Section by Transfer Matrix Method (전달행렬법에 의한 변단면 곡선 상자형 거더교의 정적해석)

  • Kim, Yong-Hee;Lee, Yoon-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.4
    • /
    • pp.109-120
    • /
    • 2003
  • The state-of-art of curved box girder bridge with cross section design has advanced in various area. In these days, several analytical techniques for behaviors of curved box girder bridges cross section are available to engineers. The transfer matrix method is extensively used for the structural analysis because its merit in the theoretical background and applicability. The technique is attractive for implementation on a numerical solution by means of a computer program coded in Fortran language with a few elements. To demonstrate this fact, it gives good results which compare well with finite element method. Therefore, this paper proposed the static analysis method of curved box bridge with cross section by transfer matrix method based on pure-torsional theory and the optimal span ratio/variable cross section ratio of 3 span continuous curved box girder bridge.

An Experimental Study on Flexural Strength of Composite Beam with Reduced Top Flange of Steel (상부플랜지를 감소시킨 합성보의 휨내력에 관한 실험적 연구)

  • Moon, Chan-II;Jeong, Jae-Hun;Kim, Jin-Moo;Joo, Kyong-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.3
    • /
    • pp.153-160
    • /
    • 2000
  • In simply supported composite beams, the neutral axis of the composite cross section usually is located the top flange of the steel I-shape, so that the top flange does not impart much strength to the member. This suggests that omitting the top flange entirely could be a means to lower the cost of the beam without greatly reducing the strength. The purpose of this investigation is to research flexural strength and behavior of the composite beams with reduced top flange of steel. Five specimens with H and inverted T steel section were tested. As the test results, comparison of the experimental to computed full-plastic moment, and variations of flexural strength with reduced top flange were analyzed.

  • PDF

The Behavior of Tension Splices Fastened with Bolted Connections (볼트로 접합된 인장 이음부의 거동)

  • Choi, Byong-Jeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.1
    • /
    • pp.225-232
    • /
    • 2005
  • The paper presented results of the strength distributions and tension failure behaviors of splices subjected to tension forces. The bolting patterns in the tension splices are regular and staggered patterns in the research. The finite element analyses were carried out to examine the experimental results and evaluated the stress distribution patterns. The yield stresses, maximum tension stresses, stress distribution ratios, and effective net areas were analyzed through the tension experiments.

Detection of the Cavity Behind the Tunnel Lining by Single Channel Seismic and GPR Method (GPR 및 단일채널 탄성파탐사에 의한 터널라이닝 배면공동 조사)

  • Shin, Sung-Ryul;Jo, Chul-Hyun;Shin, Chang-Soo;Yang, Seung-Jin;Jang, Won-Yil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.4
    • /
    • pp.148-158
    • /
    • 1998
  • Determining the thickness if concrete lining and detecting of the cavity where is located behind tunnel lining plays an important role in the safety diagnosis of tunnel structure and the quality control. In this study, we made use of GPR and seismic method in order to find the cavity or flaw. Although GPR is very useful method in the concrete lining without rebar, it is difficult to detect the cavity in the reinforced concrete lining. We applied mini-seismic method to the reinforced concrete lining. The obtained seismic data was processed by means of seismic section in time domain and image section of power spectrum in frequency domain using Impact-Echo method as well. The proposed method can accurately show the location and depth of the cavity in the reinforced concrete lining.

  • PDF

An Analytical Study on Application of Section Increment at Internal Support with External Prestressing Method to Continuous Steel Plate Girder Bridge (연속 강 플레이트거더교에서 내부지점보강과 외부프리스트레싱의 적용에 관한 해석적 연구)

  • Shim, Jae-Joong;Hong, Sung-Nam;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.128-136
    • /
    • 2010
  • It has been verified that there is an effect of diminishing in section bringing in internal core section reinforcement and external prestressing rather than general plate-girder bridge as a consequence of analysis. In particular, positive effect was seen in the aspect of usability when external prestressing was in application as rises gained from it minimized the hanging down of a bridge. Based on the result of analysis, a sectional diagram applicable per number of girder has been illustrated which made it possible to estimate the intensity of internal stress in the futurewhere number of girder is limited to 4 and regression equation is presented after regression analysis has been carried out.

A Study on the Optimal Design of Prestressed Concrete Box Girder Bridges (프리스트레스트 콘크리트 박스 거더 교량의 최적설계에 관한 연구)

  • Noh, Kum-Rae;Yun, Hee-Taek;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.2
    • /
    • pp.139-149
    • /
    • 2000
  • In the preliminary design stage of prestressed concrete (PSC) box girder bridges, the design factors decided by inexperience designer could heavily affect to the results of final design. There is a possibility that the design ends up with an excessively wasteful design. To achieve an economical design with preventing an excessive design, the optimal design technique has been developed using ADS optimal program and SPCFRAME in this study. The objective function for the optimal design problem is the material cost of box girders and constrained functions are constituted with design specifications and workability. The Sequential Unconstraint Minimization Technique (SUMT) is used for the optimal design in this study. We designed an uniform cross-section bridge and an ununiform cross-section bridge in the same design condition by optimal design technique developed in this study. Analyzing the results obtained for various tendon layouts, we suggest a standard tendon layout which gives the most effective structural behavior.

  • PDF

Failure Behavior of Non-seismic RC Column with aspect ratio of 4.0 (형상비 4.0인 비내진 철근콘크리트 기둥의 파괴거동)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.59-66
    • /
    • 2020
  • Two octagonal RC bridge columns of small scale model were tested under cyclic lateral load with constant axial load. One in two specimens was solid cross section, the other was hollow cross section. The volumetric ratio of transverse spiral hoop of all specimens is 0.00206. The columns showed flexure-shear failure. Failure behavior and seismic performance were investigated. The test results showed that the structural performance of the hollow specimen such as initial crack pattern, initial stiffness, and energy dissipation performance was comparable to that of the solid specimen, but the lateral strength, ultimate displacement, energy dissipation performance of hollow specimen noticeably decreased after drift ratio of 3%.

Mechanical and Electrical Characteristics of Concrete Members Enlarged with Self-Sensing Cementitious Materials for Repair (자기감지형 보수재로 단면증타된 콘크리트 부재의 역학 및 전기적 특성 )

  • Gun-Cheol Lee;Geon-Woo Im;Chang-Min Lee;Sung-Won Hong;Young-Min Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.139-146
    • /
    • 2023
  • In this study, compressive strength and adhesion strength were measured as repair materials to evaluate the mechanical and electrical properties of compression and shear specimens with self-sensing repair materials. As a result of the experiment, the strength improvement rate of the compression test specimen was higher than the section enlargement area ratio, but the shear test specimen did not show an improvement in strength as much as the section enlargement area ratio. Compression experiments under load showed high correlation between FCR-Strain and FCR-Stress, confirming self-sensing performance. However, the shear test did not show as much correlation as the compression test. Accordingly, it is judged that the self-sensing repair material is suitable for the compression member on which the compression load acts in the building.