• Title/Summary/Keyword: Secondary voltage

Search Result 730, Processing Time 0.025 seconds

Speed Sensorless Control of Induction Motors in the Very Low Speed Region Considering the Secondary Resistance Identification using Flux Signal (자속정보를 이용한 2차저항 동정기능을 갖는 유도전동기의 저속영역 속도센서리스 제어)

  • Lee, Z.G.;Jeong, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.308-310
    • /
    • 2001
  • This paper investigates a novel speed sensorless control method of I.M considering the secondary resistance identification based on the transientless torque control technique. Especially, this paper aimed at the identification of the secondary resistance simultaneously with speed estimation superposing of sinusoidal flux wave to a constant flux value. Furthermore, the secondary flux with some frequency is controlled independently on torque control. The proposed speed estimation method is derived from a motor circuit equation theoretically and also it can be conducted easily by detecting primary motor currents and primary voltage commands at every sampling time. Some numerical simulations with the assumption of using a pulse width modulation(PWM) voltage source inverter are performed to verify the proposed method.

  • PDF

Finite Element Analysis of Gas Discharge in Transient State Considering Secondary Electron Emission Effects (2차 전자방출 효과를 고려한 기체방전의 과도상태 유한요소해석)

  • Kim, Nam-Kyung;Jeung, Gi-Woo;Choi, Nak-Sun;Lee, Se-Hee;Kim, Dong-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1276-1281
    • /
    • 2010
  • To analyze the gas discharge phenomena in parallel-plane electrodes, the fully coupled finite element method (FEM) considering secondary electron emission effects in discharge column was adopted in this paper. Two coupled equations of the hydrodynamic diffusion-drift equations for three carriers and the Poisson's equation for electric scalar potential should be solved as a system equation. The proposed method including two secondary electron processes of the photoemission and background ionization has been successfully applied to evaluating the breakdown voltage in parallel-plane electrodes and is verified by comparing its numerical results with the experimental ones. From the obtained results, it is inferred that the proposed numerical scheme will be useful for predicting and understanding streamer transient phenomena.

Full Bridge PWM ZVZCS DC/DC Converter with Secondary Auxiliary Circuit (2차측에 보조회로를 장착한 풀 브릿지 PWM ZVZCS DC/DC 컨버터)

  • Hwang, Hyun-Tae;Lee, Jong-Kyu;Kim, Hyuk;Lee, Sung-Paik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1303-1305
    • /
    • 2000
  • A zero voltage and zero current switching(ZVZCS) fullbridge (FB) PWM converter with secondary auxiliary circuit is proposed. Based on the ZVZCS technique, the ZCS of the lagging-leg switch and ZVS of the leading-leg switch are implemented. And the each secondary side voltage overshoot is decreased by additional secondary auxiliary circuit in this paper. The illustration of its operation principle and the simulation result are presented here.

  • PDF

Speed Sensorless Control of Induction Motors in the Very Low Speed Region Considering the Secondary Resistance Identification (2차 저항 동정을 고려한 유도전동기의 저속영역 속도센서리스 제어)

  • Hwang, D.I.;Jeong, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1042-1045
    • /
    • 2000
  • Speed control without speed sensor is expected strongly to progress reliability, simplicity and cost performance of I.M and to expand its application part. This paper investigates a novel speed estimation method of I.M considering the secondary resistance identification based on the transientless torque control technique. Especially, this paper aimed at the identification of the secondary resistance simultaneously with speed estimation. For this, the secondary flux with some frequency is controlled independently on torque. The proposed speed estimation method is derived from a motor circuit equation theoretically and also it can be conducted easily by detecting primary motor currents and primary voltage commands at every sampling time. Some numerical simulations with the assumption of using a pulse width modulation(PWM) voltage source inverter and experimental results are performed to verify the proposed method.

  • PDF

A Study on the Zero-Voltage and Zero-Current-Switching Three Level DC/DC Converter using Secondary Coupled Inductor (2차측 결합 인덕터를 이용한 ZVZCS Three Level DC/DC 컨버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Baek, Soo-Hyun;Kim, Pill-Soo;Lee, Eun-Young
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.200-204
    • /
    • 2001
  • A ZVZCS(Zero Voltage and Zero Current Switching) Three Level DC/DC Converter is presented to secondary auxiliary circuit. The new converter presented in this paper used a phase shift control with a flying capacitor in the primary side to achieve ZVS for the outer switch. A secondary auxiliary circuit, which consists of one small capacitor two small diode and one coupled inductor is added in the secondary to provides ZVZCS conditions to primary switches, ZVS for outer switches and ZCS for inner switches. Many advantages including simple circuit topology high efficiency, and low cost make the new converter attractive for high power applications. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 1kW 50kHz IGBT based experimental circuit.

  • PDF

Voltage Oscillation Reduction Technique for Phase-Shift Full-Bridge Converter (위상 천이 풀-브릿지 컨버터를 위한 새로운 전압 진동 제거 기술)

  • Park Ki-Bum;Kim Chong-Eun;Moon Gun-Woo;Youn Myung-Joong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.598-609
    • /
    • 2005
  • Conventional phase shift full bridge (PSFB) converter has serious voltage oscillation problem across the secondary rectifier diodes, which would require the dissipate snubber circuit, thus degrades the overall efficiency. To overcome this problem a new simple voltage oscillation reduction technique (VORT) which effectively reduce the voltage oscillation of the secondary rectifier diodes for phase shift full bridge converter is proposed. Therefore, no dissipate snubber for rectifier diodes is needed. In addition, since it has wide zero voltage switching (ZVS) range, high efficiency can be achieved. Operational principle, analysis of voltage oscillation, and design consideration are presented compare with that of the conventional PSFB converter. To confirm the validity of the proposed VORT, experimental results from a 420W prototype are presented.

Comparison of Characteristics on the Flux-Lock and the Transformer Type SFCLs with Three Superconducting Units (3개의 초전도 소자를 갖는 자속구속형 SFCL과 변압기형 SFCL의 특성 비교)

  • Lee, Ju-Hyoung;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.79-84
    • /
    • 2009
  • In order to increase the capacity of the superconducting fault current limiter(SFCL), the current and voltage grades of the SFCL must be increased. As a method for the increase of the current and voltage grades of the SFCL, we compared the various characteristics between the flux-lock type SFCL "With three superconducting units connected in series and the transformer type SFCL using the transformer with three secondary circuits. One of three superconducting units had not quenched in the flux-lock type SFCL. Therefore, the unbalanced power burden happened because of the voltage difference generated by unbalanced quenching between the superconducting units. In the meantime, the three superconducting units were all quenched in the transformer type SFCL using the transformer, and the voltage difference generated between the superconducting units was decreased. Therefore, the difference of critical characteristics was complemented by distribution of fault current in accordance with the turn's ratio between primary and secondary windings. The unbalanced power burden of the superconducting units was reduced due to flux-share between the superconducting units in the transformer. In conclusion, the capacity increment of the SFCL using a transformer was easier due to equal distribution of voltages generated by simultaneous quench of the superconducting units. We think that the characteristics is improved more because of the decrease of saturation in the iron core if the secondary winding is increased in the SFCL using the transformer.

New Multi-Output LLC Resonant Converter for High Efficiency and Low Cost PDP Power Module

  • Kim Chong-Eun;Moon Gun-Woo;Lee Jun-Young;Oh Kwan-Il;Kwon Joong-Yeol
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.71-74
    • /
    • 2006
  • A new multi-output LLC resonant converter is proposed for high efficiency and low cost plasma display panel (PDP) power module. In the proposed converter, zero-voltage (ZV) turn-on of the primary MOSFETs and zero-voltage (ZC) turn-on and turn-off of the secondary diodes are guaranteed in the overall input voltage and output load ranges. In addition, the primary MOSFETs and the secondary diodes have the low voltage stresses clamped to input and the output voltages, respectively. Therefore, the proposed converter shows the high efficiency due to the minimized switching and conduction losses. Moreover, by employing the transformer with multiple secondary windings, the proposed converter can have multiple outputs, which show the great crossregulation characteristics. Therefore, the proposed converter is suitable for high efficiency and low cost PDP power module.

  • PDF

Analysis and Implementation of a New ZVS DC Converter for Medium Power Application

  • Lin, Bor-Ren;Shiau, Tung-Yuan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1296-1308
    • /
    • 2014
  • This paper presents a new zero voltage switching (ZVS) converter for medium power and high input voltage applications. Three three-level pulse-width modulation (PWM) circuits with the same power switches are adopted to clamp the voltage stress of MOSFETs at $V_{in}/2$ and to achieve load current sharing. Thus, the current stresses and power ratings of transformers and power semiconductors at the secondary side are reduced. The resonant inductance and resonant capacitance are resonant at the transition interval such that active switches are turned on at ZVS within a wide range of input voltage and load condition. The series-connected transformers are adopted in each three-level circuit. Each transformer can work as an inductor to smooth the output current or a transformer to achieve the electric isolation and power transfer. Thus, no output inductor is needed at the secondary side. Three center-tapped rectifiers connected in parallel are used at the secondary side to achieve load current sharing. Compared with the conventional parallel three-level converters, the proposed converter has less switch counts. Finally, experiments based on a 1.44kW prototype are provided to verify the operation principle of proposed converter.

Characteristics of Transformer-Type SFCL according to the Connecting Methods of Secondary Coils (2차 권선의 연결방법에 따른 변압기형 초전도 한류기의 특성)

  • Cho, Yong-Sun;Park, Hyoung-Min;Chung, Soo-Bok;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2078-2083
    • /
    • 2007
  • We have analyzed operating characteristics of transformer-type superconducting fault current limiter (SFCL) according to the serial or parallel connections of secondary coils with $YBa_2Cu_3O_7$ (YBCO) thin films. The turn ratio between the primary and secondary coils was 63:21. Transformer-type SFCL using a transformer with secondary winding of serial or parallel coils could reduce the unbalanced quench caused by differences of the critical current density between YBCO thin films. We found that transformer-type SFCL having serial or parallel connections induced simultaneous quench between the superconducting units. The limiting current in the transformer-type SFCL with a parallel connection was lowered to 30 % compared to the SFCL with a serial connection. In the meantime, when the currents generated in the superconducting units were similar, the voltage value in the parallel connection was 60 % as low as that in the serial connection. However, the voltage generated in the primary winding was some higher. In conclusion, we found that transformer-type SFCL with parallel connection of secondary coils was more effective in fault current limiting characteristics and in the reduction of the consumption power for superconducting units compared to those of the transformer-type SFCL with serial connection of secondary coils.