• 제목/요약/키워드: Secondary resonance

검색결과 273건 처리시간 0.023초

In Vivo Three-dimensional Evaluation of the Functional Length of Glenohumeral Ligaments

  • Goto, Akira;Sahara, Wataru;Koishi, Hayato;Yoshikawa, Hideki;Sugamoto, Kazuomi
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 2009년도 제17차 학술대회
    • /
    • pp.174-174
    • /
    • 2009
  • The acromioclavicular-hook-plate is one of the surgical treatments for distal clavicle fracture and traumatic acromioclavicular (AC) joint dislocation. Although this procedure can obtain rigid and accurate anatomical reduction of the AC joint, secondary widening of the hook-hole in the acromion is often seen during postoperative follow-up. This complication is owing to the high-degree of mobility of the AC joint. Therefore, it is important to evaluate the effect on these complications due to the position of the hook-hole. The purpose of the present study is to investigate three-dimensionally the effect due to the position of the hook-hole during arm abduction motion. We studied in vivo and three-dimensional kinematics of the normal shoulder joint with use of a markerless bone-registration technique. Magnetic resonance images of 14 shoulders of 7 healthy volunteers were acquired in 7 positions between $0^{\circ}$ and $180^{\circ}$ of abduction. We created three-dimensional computer models of the bones and the acromioclavicular-hook-plate. Based on the three-dimensional kinematics data, we simulated the widening of the hook-hole each different positioning of the hook-hole. The widths of the hook-holes almost linearly increased. And these widths significantly increased, when we put the hook-hole on the acromion from AC joint to 20 mm and 25 mm posterior position.

  • PDF

Kinetic Study on Aminolysis of Y-Substituted-Phenyl X-Substituted-Benzoates: Effects of Substituents X and Y on Reactivity and Reaction Mechanism

  • Jeon, Seong Hoon;Kim, Hyun Soo;Han, Young Joon;Kim, Min-Young;Um, Ik-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권2호
    • /
    • pp.471-476
    • /
    • 2014
  • A kinetic study on aminolysis of 2-chloro-4-nitrophenyl X-substituted-benzoates (2a-k) in 80 mol % $H_2O/_20mol%$ DMSO at $25.0^{\circ}C$ is reported. The Br${\emptyset}$nsted-type plot for the reactions of 2-chloro-4-nitrophenyl benzoate (2g) with a series of cyclic secondary amines curves downward (e.g., ${\beta}_1=0.25$, ${\beta}_2=0.85$ and $pK_a^o=10.3$), which is typical of reactions reported to proceed through a stepwise mechanism with a change in ratedetermining step (RDS). The Hammett plot for the reactions of 2a-k with piperidine consists of two intersecting straight lines, while the corresponding Yukawa-Tsuno plot exhibits an excellent linear correlation with ${\rho}_X=1.15$ and r = 0.59. Thus, it has been concluded that the nonlinear Hammett plot is not due to a change in RDS but is caused by stabilization of substrates through resonance interactions between the electron-donating substituent and the C=O bond. Substrates possessing a substituent at the 2-position of the leaving aryloxide deviate negatively from the curved Br${\emptyset}$nsted-type plot for the reactions of Y-substituted-phenyl benzoates (3a-i), implying that the steric hindrance exerted by the substituent at the 2-position is an important factor which governs the reactivity of Y-substituted-phenyl benzoates.

PDP 유지전원단을 위한 높은 효율을 갖는 새로운 페이지쉬프트 풀브릿지 컨버터 (A New High Efficiency Phase Shifted Full Bridge Converter for Sustaining Power Module of Plasma Display Panel)

  • 이우진;김정은;한상규;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.445-448
    • /
    • 2005
  • PDP 유지전원단을 위한 고효율을 갖는 새로운 페이지 쉬프트 풀브릿지 컨버터를 제안한다. 제안된 컨버터는 Rectifier로 Voltage Doubler를 사용함으로서, 큰 사이즈의 Output Inductor가 없게 되어 간단한 구조를 가지게 되며 Rectifier Diodes의 전압 스트레스가 출력전압으로 클램핑되어서 스너버회로가 필요없다는 장점을 가지게 된다. 또한 넓은 영전압 스위칭 구간을 가지며, 트랜스포머의 기생성분인 Leakage 인덕터와 Voltage doubler의 캐패시터간의 공진을 이용함으로서 전류가 작은 RMS값을 가지게 되어서 낮은 도통손실과 Rectifier Diode의 전류 스트레스 또한 낮다는 장점을 가지게 된다. 본 논문을 통해 제안된 컨버터의 동작원리와 해석, 실험을 수행하였다.

  • PDF

Kinetic Study on Aminolysis of 4-Chloro-2-Nitrophenyl X-Substituted-Benzoates in Acetonitrile and in 80 mol % H2O/20 mol % DMSO: Effect of Medium on Reactivity and Reaction Mechanism

  • Kim, Ha-Ram;Um, Tae-Il;Kim, Min-Young;Um, Ik-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권4호
    • /
    • pp.1128-1132
    • /
    • 2014
  • A kinetic study on aminolysis of 4-chloro-2-nitrophenyl X-substituted-benzoates (6a-i) in MeCN is reported. The Hammett plot for the reactions of 6a-i with piperidine consists of two intersecting straight lines, while the Yukawa-Tsuno plot exhibits an excellent linear correlation with ${\rho}_X$ = 1.03 and r = 0.78. The nonlinear Hammett plot is not due to a change in rate-determining step (RDS) but is caused by the resonance stabilization of substrates possessing an electron-donating group in the benzoyl moiety. The Br${\phi}$nsted-type plot for the reactions of 4-chloro-2-nitrophenyl benzoate (6e) with a series of cyclic secondary amines is linear with ${\beta}_{nuc}$ = 0.69, an upper limit for reactions reported to proceed through a concerted mechanism. The aminolysis of 6e in aqueous medium has previously been reported to proceed through a stepwise mechanism with a change in RDS on the basis of a curved Br${\phi}$nsted-type plot. It has been concluded that instability of the zwitterionic tetrahedral intermediate ($T^{\pm}$) in MeCN forces the reaction to proceed through a concerted mechanism. This is further supported by the kinetic result that the amines used in this study are less reactive in MeCN than in $H_2O$, although they are more basic in MeCN over 7 $pK_a$ units.

Mitoxantrone Binds to Nopp140, an Intrinsically Unstructured Protein, and Modulate its Interaction with Protein Kinase CK2

  • Lee, Won-Kyu;Lee, Sang-Yeop;Na, Jung-Hyun;Jang, Sung-Woo;Park, Chan-Ryang;Kim, Soo-Youl;Lee, Si-Hyeong;Han, Kyou-Hoon;Yu, Yeon-Gyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권6호
    • /
    • pp.2005-2011
    • /
    • 2012
  • Nopp140 is a highly phosphorylated protein that resides in the nucleolus of mammalian cell and is involved in the biogenesis of the nucleolus. It interacts with a variety of proteins related to the synthesis and assembly of the ribosome. It also can bind to a ubiquitous protein kinase CK2 that mediates cell growth and prevents apoptosis. We found that Nopp140 is an intrinsically unfolded protein (IUP) lacking stable secondary structures over its entire sequence of 709 residues. We discovered that mitoxantrone, an anticancer agent, was able to enhance the interaction between Nopp140 and CK2 and maintain suppressed activity of CK2. Surface plasma resonance studies on different domains of Nopp140 show that the C-terminal region of Nopp140 is responsible for binding with mitoxantrone. Our results present an interesting example where a small chemical compound binds to an intrinsically unfolded protein (IUP) and enhances protein-protein interactions.

Methods to determine the volume of infrapatellar fat pad as an indicator of anterior cruciate ligament tear

  • Cheruvu, B.;Tsatalis, J.;Laughlin, R.;Goswami, T.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제3권1호
    • /
    • pp.27-35
    • /
    • 2016
  • Anterior knee pain is a major problem among adolescents and young adults especially those who participates in sports. The most common pathogenesis of anterior knee pain can arise from compression and shear forces in the patellofemoral joint. It is also caused by impingement of infrapatellar fat pad. Fat pad impingement can occur when the fat pad becomes swollen and inflamed due to a direct blow or chronic irritation. As a result, the bottom tip (or inferior pole) of the patella can pinch the fat pad. One of the many causes of swollen fat pad can be secondary to anterior cruciate ligament (ACL) injury. The aim of this study was to compare the infrapatellar fat pad volume in patients with acute ACL injury and a group of age-, gender-, and activity- matched controls with intact ligament. Axial magnetic resonance (MR) images have been performed on 32 patients with torn ACL and 40 control patients. The volume of the fat pad was measured digitally from MR image by using a 3d Reconstruction software, ellipsoidal approximation, and a MATLAB code. The results were compared between patients with torn ACL and control group. Patients with a torn ACL had a significantly larger fat pad than the controls (P=0.01). There was no significant difference between the methods used to measure the infrapatellar fat pad volume (P=0.83-0.87). Thus, lesions of the infrapatellar fat pad is often associated with ACL injury.

RNA의 이차 구조 요소 및 삼차 구조 요소를 추출하기 위한 PDB 구조 데이터 마이닝 (Mining the Secondary and Tertiary Structures Elements of RNA from the Structure Data of PDB)

  • 임대호;한경숙
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2003년도 가을 학술발표논문집 Vol.30 No.2 (2)
    • /
    • pp.826-828
    • /
    • 2003
  • 이제까지 Protein이나 RNA와 같은 분자의 구조는, 대부분 X-ray crystallography나 Nuclear Magnetic Resonance (NMR) 방법을 통해 분석이 이루어 졌다. 이 방법들은 실제 분자를 직접 원자레벨에서 분석하는 방법으로, 분자를 구성하는 모든 원자의 3차원 좌표 정보를 얻어 낼 수 있다. 원자의 3차원 좌표 정보는 분자의 전체적인 모양과 구조를 이해하는데 유용한 정보이다. 하지만, 분자의 구조를 좀 더 완벽히 이해하기 위해서는 원자 레벨의 좌표 정보 보다는 좀 더 높은 차원에서의 구조 정보가 필요하다. 특히 분자의 구조를 예측하거나, 분자들 사이에 결합 관계를 예측하기 위해서는, 원자 레벨의 정보만으로는 필요한 모든 정보를 얻을 수 없다. 이러한 경우, 분자의 2차원 또는 3차원 구조 요소 (structural elements)가 더욱 좋은 정보를 제공해 줄 수 있다. Protein 분자의 경우. 이미 3차원 좌표 정보를 이용해서, 2차원 구조 요소를 알아내는 자동화된 방법이 알려져 있다. 그러나 RNA의 경우 protein에 비해 알려진 결정 구조가 적기 때문에. 아직까지 2차원 구조 요소나 3차원 구조 요소를 알아내는 자동화된 방법이 알려져 있지 않다. 따라서, 이제까지는 RNA의 구조 요소를 알아내기 위해, 사람이 직접 RNA분자의 3차원 좌표 정보를 분석함으로써 많은 시간과 노력이 필요했다. 이 때문에, 우리는 RNA의 원자들의 3차원 좌표 정보를 이용해서, 2차원 구조요소와 3차원 구조 요소 정보를 자동화된 방법으로 밝혀내는 알고리즘을 개발하였다. 우리는 분자를 구성하고 있는 원자들의 3차원 좌표 정보를 Protein data bank (PDB)에서 가져왔다. 우리의 알고리즘은 PDB file형태의 데이터라면 protein-RNA 복합체나 RNA 분자 모두에서 RNA의 2차원 구조 요소나 3차원 구조 요소를 얻어낼 수 있다. 우리의 연구는 RNA의 원자레벨의 3차원 좌표 정보를 이용해서 RNA의 구조 요소를 뽑아내는 첫 번째 시도로, 우리의 알고리즘을 통해 얻어진 구조 정보는 RNA의 구조 예측 연구나. protein-RNA complex의 결합 예측 연구에 많은 도움을 줄 수 있으리라 기대된다.

  • PDF

Phenolic Compounds from the Fruit Body of Phellinus linteus Increase Alkaline Phosphatase (ALP) Activity of Human Osteoblast-like Cells

  • Lyu, Ha-Na;Lee, Dae-Young;Kim, Dong-Hyun;Yoo, Jong-Su;Lee, Min-Kyung;Kim, In-Ho;Baek, Nam-In
    • Food Science and Biotechnology
    • /
    • 제17권6호
    • /
    • pp.1214-1220
    • /
    • 2008
  • Secondary metabolites from the fruit body of Phellinus linteus were evaluated for their proliferative effect on human osteoblast-like cells. 3-[4,5-Dimethylthiazole-2-y1]-2,5-diphenyl-tetraxolium bromide (MTT) assay and alkaline phosphatase (ALP) activity assay were used to assess the effect those isolates on the human osteoblast-like cell line (Saos-2). Activity-guided fractionation led to the isolation of ALP-activating phenolic compounds through the extraction of P. linteus, solvent partitioning, and repeated silica gel and octadecyl silica gel (ODS) column chromatographic separations. From the result of spectroscopic data including nuclear magnetic resonance (NMR), mass spectrometry (MS), and infrared spectroscopy (IR), the chemical structures of the compounds were determined as 4-(4-hydroxyphenyl)-3-buten-2-one(1), 2-(3',4'-dihydroxyphenyl)-1,3-benzodioxole-5-aldehyde (2), 4-(3,4-dihydroxyphenyl)-3-buten-2-one (3), 3,4-dihydroxybenzaldehyde (4), and protocatechuic acid methyl ester (5), respectively. This study reports the first isolation of compounds 1-3 and 5 from P. linteus. In addition, all phenolic compounds stimulated proliferation of the osteoblast-like cells and increased their ALP activity in a dose-dependent manner ($10^{-8}$ to $10^{-1}\;mg/mL$). The present data demonstrate that phenolic compounds in P. linteus stimulated mineralization in bone formation caused by osteoporosis. The bone-formation effect of P. linteus seems to be mediated, at least partly, by the stimulating effect of the phenolic compounds on the growth of osteoblasts.

모형 덤프 연소기에서 혼합기 유입구 길이 변화에 따른 연소불안정 특성에 대한 실험적 연구 (An Experimental Study on Combustion Instability Characteristics of Various Fuel-Air Mixing Section Geometry in a Model Dump Shape Combustor)

  • 김민기;윤지수;황정재;윤영빈
    • 한국추진공학회지
    • /
    • 제16권4호
    • /
    • pp.57-69
    • /
    • 2012
  • 본 연구는 희박 예혼합 연소기에서 연소실과 연료-공기 혼합부의 공진모드의 관계가 연소불안정에 어떤 영향을 미치고 있는지에 대하여 실험적으로 확인한 연구이다. 다체널 동압측정을 통하여 각각 위치에서 동압의 모드와 각 센서들간의 phase를 분석하여 연소불안정의 원인을 규명할 수 있었다. 연소실의 길이(800~1800)와 혼합부의 길이(470, 550, 870 mm)를 음향학적 경계로 일치시켜 연소불안정 특성을 확인해 보았을 때 두가지 서로 다른 연소불안정 모드를 확인할 수 있었는데 저주파 연소불안정 특성은 화염의 열방출 섭동과 연소실의 공진모드에 기인하며, 고주파 영역대의 연소불안정 현상은 혼합부의 길이를 변경하였을 때 발생하는 또 다른 불안정 현상임을 실험적으로 확인할 수 있었다.

A feasibility study of using a 3D-printed tumor model scintillator to verify the energy absorbed to a tumor

  • Kim, Tae Hoon;Lee, Sangmin;Kim, Dong Geon;Jeong, Jae Young;Yang, Hye Jeong;Schaarschmidt, Thomas;Choi, Sang Hyoun;Cho, Gyu-Seok;Kim, Yong Kyun;Chung, Hyun-Tai
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3018-3025
    • /
    • 2021
  • The authors developed a volumetric dosimetry detector system using in-house 3D-printable plastic scintillator resins. Three tumor model scintillators (TMSs) were developed using magnetic resonance images of a tumor. The detector system consisted of a TMS, an optical fiber, a photomultiplier tube, and an electrometer. The background signal, including the Cherenkov lights generated in the optical fiber, was subtracted from the output signal. The system showed 2.1% instability when the TMS was reassembled. The system efficiencies in collecting lights for a given absorbed energy were determined by calibration at a secondary standard dosimetry laboratory (kSSDL) or by calibration using Monte Carlo simulations (ksim). The TMSs were irradiated in a Gamma Knife® IconTM (Elekta AB, Stockholm, Sweden) following a treatment plan. The energies absorbed to the TMSs were measured and compared with a calculated value. While the measured energy determined with kSSDL was (5.84 ± 3.56) % lower than the calculated value, the energy with ksim was (2.00 ± 0.76) % higher. Although the TMS detector system worked reasonably well in measuring the absorbed energy to a tumor, further improvements in the calibration procedure and system stability are needed for the system to be accepted as a quality assurance tool.