• Title/Summary/Keyword: Secondary resonance

Search Result 271, Processing Time 0.029 seconds

Evaluation of the stability of sandblasted, large-grit, acid-etched implants with tapered straight body design (테이퍼드 직선형 SLA 임플란트의 안정성 평가)

  • Kim, Yong-Gun;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.80-88
    • /
    • 2018
  • Purpose: Implant surface modification and implant design are the principle targets for achieving successful primary stability. The aim of this study was to measure implant stability quotient (ISQ) values of sandblasted, large-grit, acid-etched (SLA) implants with tapered straight body design during the healing period, and to determine the various factors affecting implant stability. Materials and Methods: To measure implant stability, resonance frequency analysis (RFA) was performed in 26 patients (13 women and 13 men) with 44 SLA implants with tapered straight body design. Implant stability (ISQ values) was evaluated at baseline and healing abutment connection (12 weeks), and the correlations between RFA and insertion torque (IT), bone quality, and jawbone were determined. Results: The mean ISQ value of the implants was $69.4{\pm}10.2$ at the time of implant placement (baseline) and $81.4{\pm}6.9$ at the time of healing abutment connection (P < 0.05). Significant differences were found between RFA and bone quality and between RFA and jawbone (P < 0.05). No significant differences were found between RFA and IT, insertion area, fixture diameter, and implant length (P > 0.05). Conclusion: ISQ values of SLA implants with tapered straight body design were high at baseline and healing abutment connection. It was concluded that SLA implants with tapered straight body design show improved primary and secondary stability, and that immediate or early loading may be applicable.

Application of Volumetric Analysis to Glioblastomas: a Correlation Study on the Status of the Isocitrate Dehydrogenase Mutation

  • Bae, Seon Yong;Park, Chul-Kee;Kim, Tae Min;Park, Sung-Hye;Kim, Il Han;Choi, Seung Hong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.4
    • /
    • pp.218-223
    • /
    • 2015
  • Purpose: To investigate whether volumetric analysis based on T2WI and contrast-enhanced (CE) T1WI can distinguish between isocitrate dehydrogenase-1 mutation-positive ($IDH1^P$) and -negative ($IDH1^N$) glioblastomas (GBMs). Materials and Methods: We retrospectively enrolled 109 patients with histopathologically proven GBMs after surgery or stereotactic biopsy and preoperative MR imaging. We measured the whole-tumor volume in each patient using a semiautomatic segmentation method based on both T2WI and CE T1WI. We compared the tumor volumes between $IDH1^P$ (n = 12) and $IDH1^N$ (n = 97) GBMs using an unpaired t-test. In addition, we performed receiver operating characteristic (ROC) analysis for the differentiation of $IDH1^P$ and $IDH1^N$ GBMs using the tumor volumes based on T2WI and CE T1WI. Results: The mean tumor volume based on T2WI was larger for $IDH1^P$ GBMs than $IDH1^N$ GBMs ($108.8{\pm}68.1$ and $59.3{\pm}37.3mm^3$, respectively, P = 0.0002). In addition, $IDH1^P$ GBMs had a larger tumor volume on CE T1WI than did $IDH1^N$ tumors ($49.00{\pm}40.14$ and $22.53{\pm}17.51mm^3$, respectively, P < 0.0001). ROC analysis revealed that the tumor volume based on T2WI could distinguish $IDH1^P$ from $IDH1^N$ with a cutoff value of 90.25 (P < 0.05): 7 of 12 $IDH1^P$ (58.3%) and 79 of 97 $IDH1^N$ (81.4%). Conclusion: Volumetric analysis of T2WI and CE T1WI could enable $IDH1^P$ GBMs to be distinguished from $IDH1^N$ GBMs. We assumed that secondary GBMs with $IDH1^P$ underwent stepwise progression and were more infiltrative than those with $IDH1^N$, which might have resulted in the differences in tumor volume.

Comparison of Main Circuit Type Characteristics of LED Driver for Output Ripple Reduction (출력 리플 저감을 위한 LED 드라이버의 주회로 방식 특성 비교)

  • Park, Dae-Su;Kim, Tae-Kyung;Oh, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.491-499
    • /
    • 2019
  • Recently, there has been increasing demand for power quality in power supply devices. The IEC 61000-3-2 standard requires that the AC / DC power supply for lighting meet the specifications for the power factor (PF) and total waveform distortion (THD). In addition, advanced countries in Europe are regulating the ripple rate as 15 ~ 30% for the flicker phenomenon caused by the change in the amount of foot energy due to the change in current of the output terminal. Therefore, domestic standards and regulations are being updated. This study adopted the Flyback converter to satisfy the PFC standard, and has the circuit first and second insulation function. To reduce the low frequency ripple of the LED current, Flyback, Coupled Inductor, LC parallel resonance filter, LLC resonance filter, and Cuk were simulated by PSIM to mimic each LED driving circuit. A coupled LC resonant circuit with a coupled inductor on the primary side and LC resonance on the secondary side was also proposed for output side ripple reduction.

Intracranial anaplastic oligodendroglioma concurrent with hydrocephalus and syringomyelia in a Boston terrier dog

  • Park, Chul;Kang, Byeong-Teck;Yoo, Jong-Hyun;Kim, Ha-Jung;Jung, Dong-In;Lim, Chae-Young;Kim, Jae-Hoon;Woo, Eung-Je;Kang, Sang-Chul;Park, Hee-Myung
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.1
    • /
    • pp.93-98
    • /
    • 2008
  • A 6-year-old female Boston terrier dog was presented with seizure episode, forelimb paraparesis, excessive panting, and ataxia. On physical and neurological examination, episcleral vessel engorgement, delayed postural reaction, delayed pupillary light reflex (both direct and consensual), and crossed forelimb were noted. Serum biochemical profiles were not remarkable other than mildly elevated hepatic enzymes. On cerebrospinal fluid analysis, elevated protein concentration was observed. In magnetic resonance imaging scans, the left frontal brain lesion with ring enhancement strongly suggested the presence of intracranial tumor. Concurrently, secondary hydrocephalus and syringomyelia were also observed. The dog was euthanized at 4 months after initial presentation because of aggravated neurological signs. This case was definitely diagnosed as an intracranial anaplastic oligodendroglioma based on postmortem histopathologic examination.

An Unusual Case of Cerebral Penetrating Injury by a Driven Bone Fragment Secondary to Blunt Head Trauma

  • Lee, Jae-Il;Ko, Jun-Kyeung;Cha, Seung-Heon;Han, In-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.6
    • /
    • pp.532-534
    • /
    • 2011
  • Temple trauma that appears initially localized to the skin might possess intracranial complications. Early diagnosis and management of such complications are important, to avoid neurologic sequelae. Non-penetrating head injuries with intracranial hemorrhage caused by a driven bone fragment are extremely rare. A 53-year-old male was referred to our hospital because of intracerebral hemorrhage. He was a mechanic and one day before admission to a local clinic, tip of metallic rod hit his right temple while cutting the rod. Initial brain computed tomography (CT) and magnetic resonance imaging demonstrated scanty subdural hematoma at right temporal lobe and left falx and intracerebral hematoma at both frontal lobes. Facial CT with 3-D reconstruction images showed a small bony defect at the right sphenoid bone's greater wing and a small bone fragment at the left frontal lobe, crossing the falx. We present the unusual case of a temple trauma patient in whom a sphenoid bone fragment migrated from its origin upward, to the contralateral frontal lobe, producing hematoma along its trajectory.

Frequency control method of ozonator power supply (오존발생기 구동장치의 주파수제어에 관한 연구)

  • 최규남
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.4
    • /
    • pp.887-893
    • /
    • 1999
  • The characteristics of ozone generator targeted for air or water sterilizing in the vessel utilizing the surface corona discharge between the electrodes on the ceramic substrate was investigated by using the frequency control method. The frequency control was achieved by controlling the degree of resonance between the secondary winding inductance of transformer and the electrode capacitance of ceramic discharge plate, and the range of control was found to be 5 times of discharge current. This frequency control method showed the efficiency of 28 mP ozone generation and the stability within 3.4 % when the input voltage was varied within 40% range. The frequency control method is regarded to be more efficient way of corona discharge control compared to the conventional on/off control or voltage control methods.

  • PDF

The Dual Design of Fuel Cell Hybrid Power System using Dual Converter PCS (1.5kW 연료전지 복합발전 시스템의 듀얼 컨버터 설계)

  • Shin, Soo-Cheol;Lee, Hee-Jun;Hong, Suk-Jin;Kim, Hak-Sung;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.67-75
    • /
    • 2013
  • In this paper, parallel input/serial output dual converter is designed appropriately for fuel cell hybrid power system. In case of proposed converter, zero voltage switching condition is designed without additional resonance device using leakage inductance of transformer and output capacitance of switch, and zero voltage switching method is used. Also, the system method is for increasing power by connecting half-bridge in parallel and increasing output voltage by connecting secondary output of transformer in serial. Through this method we can increase power and decrease volume of system. So in this paper, dual converter is designed. 1.5kW fuel cell hybrid power system was implemented, and system operation and stability was verified through experiment.

Necrotizing fasciitis and streptococcal toxic shock syndrome secondary to varicella in a healthy child

  • Kwak, Byung Ok;Lee, Min Jung;Park, Hye Won;Song, Min Kyung;Chung, Sochung;Kim, Kyo Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.12
    • /
    • pp.538-541
    • /
    • 2014
  • Varicella is usually considered to be a benign disease in healthy children; however, serious complications can occur such as necrotizing fasciitis and toxic shock syndrome. We describe a 38-month-old girl with necrotizing fasciitis and streptococcal toxic shock syndrome following varicella. She was previously healthy and vaccinated against varicella at 12 months of age. She had been diagnosed with varicella three days prior to presenting at our facility; she developed fever, vomiting, and painful swelling on her left flank. Her skin lesions worsened, she became lethargic, and had episodes of hypotension and coagulopathy. Necrotizing fasciitis on the left abdominal wall, buttocks, and left thigh was diagnosed by magnetic resonance imaging, and group A Streptococcus was isolated from a tissue culture. She was diagnosed as necrotizing fasciitis and streptococcal toxic shock syndrome, and successfully treated with repeated surgical debridement and fasciotomy, in addition to intensive antibiotics. Our experience suggests that necrotizing fasciitis in patients with varicella should be considered to be a rare complication even with widespread vaccine use. Early diagnosis and intensive treatment are required to prevent a fatal outcome.

High Efficiency and Low Device Stress Voltage and Current Clamping ZVS PWM Asymmetrical Half Bridge Converter

  • Han Sang Kyoo;Moon Gun-Woo;Youn Myung Joong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.341-345
    • /
    • 2004
  • A high efficiency and low device stress voltage and current clamping BVS PWM asymmetrical half bridge converter is proposed in this paper. To achieve the ZVS of power switches along the wide load range, the transformer leakage inductor $L_{Ikg}$ is increased. Then, to solve the problem related to ringing in the secondary rectifier caused by the resonance between $L_{Ikg}$ and rectifier junction capacitors, the proposed converter employs a voltage and current clamping cell, which helps voltages and currents of rectifier diodes to be clamped at the output voltage and output current, respectively. Therefore, no RC-snubber for rectifier diodes is needed and a high efficiency as well as low noise output voltage can be realized. In addition, since all energy stored in $L_{Ikg}$ is transferred to the output side, the circulating energy problem can be effectively solved and duty loss does net exist. The operational principle, theoretical analysis, and design considerations are presented. To confirm the operation, validity, and features of the proposed circuit, experimental results from a 425W, 385-170Vdc prototype are presented.

  • PDF

Variable Output and Parallel Operation Control of EV Charger (전기자동차용 충전기의 가변출력 및 병렬운전 제어)

  • Lee, Sang-Hyeok;Kang, Seong-Gu;Awasthi, Prakash;Hwang, Jung-Goo;Lee, Seung-Yul;Wi, Han-Byul;Park, Sung-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.153-160
    • /
    • 2013
  • This research paper describes the development of battery charger with a variable output voltage capacity for charging the batteries used in electrical vehicles. The voltage and current accordingly is control via the buck converter that receives three phase current at primary side and fed to bridge rectifier which is comprised of full bridge converter and HFTR(High Frequency Transformer) for isolation and a square wave AC output. The transformer primary side is in series to divide certain charging current and the secondary side is comprised of six fix transformers so that they can generate certain amount of power and various output voltage through relay connection using 6 DC outputs. Moreover, all parallel connected full bridge serial resonant converter communicate together with upper(main) controller. The constructed structure is verified by conducting the test on PSIM as well as experimentally.