• Title/Summary/Keyword: Secondary cancer risk

Search Result 95, Processing Time 0.021 seconds

Diagnosis and Monitoring of Chronic Myeloid Leukemia: Chiang Mai University Experience

  • Tantiworawit, Adisak;Kongjarern, Supanat;Rattarittamrong, Ekarat;Lekawanvijit, Suree;Bumroongkit, Kanokkan;Boonma, Nonglak;Rattanathammethee, Thanawat;Hantrakool, Sasinee;Chai-Adisaksopha, Chatree;Norasetthada, Lalita
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.2159-2164
    • /
    • 2016
  • Background: A diagnosis of chronic myeloid leukemia (CML) is made on discovery of the presence of a Philadelphia (Ph) chromosome. The success of the treatment of this form of leukemia with tyrosine kinase inhibitor (TKI) is monitored by reduction of the Ph chromosome. Objective: To compare the role of conventional cytogenetic (CC) methods with a real time quantitative polymerase chain reaction (RQ-PCR) and fluorescence in situ hybridization (FISH) for diagnosis and treatment monitoring of CML patients. The secondary outcome was to analyze the treatment responses to TKI in CML patients. Materials and Methods: This was a retrospective study of CML patients who attended the Hematology clinic at Chiang Mai University Hospital from 2005-2010. Medical records were reviewed for demographic data, risk score, treatment response and the results of CC methods, FISH and RQ-PCR. Results: One hundred and twenty three cases were included in the study, 57.7% of whom were male with a mean age of 46.9 years. Most of the patients registered as intermediate to high risk on the Sokal score. At diagnosis, 121 patients were tested using the CC method and 118 (95.9%) were identified as positive. Five patients failed to be diagnosed by CC methods but were positive for BCR-ABL1 using the FISH method. Imatinib was the first-line treatment used in 120 patients (97.6%). In most patients (108 out of 122, 88.5%), a complete cytogenetic response (CCyR) was achieved after TKI therapy and in 86 patients (70.5%) CCyR was achieved long term by the CC method. Five out of the 35 analyzed patients in which CCyR was achieved by the CC method had a positive FISH result. Out of the 76 patients in which CCyR was achieved, RQ-PCR classified patients to only CCyR in 17 patients (22.4%) with a deeper major molecular response (MMR) in 4 patients (5.3%) and complete molecular response (CMR) in 55 patients (72.4%). In the case of initial therapy, CCyR was achieved in 95 patients (79.1%) who received imatinib and in both patients who received dasatinib (100%). For the second line treatment, nilotinib were used in 30 patients and in 19 of them (63.3%) CCyR was achieved. In half of the 6 patients (50%) who received dasatinib as second line or third line treatment CCyR was also achieved. Conclusions: CML patients had a good response to TKI treatment. FISH could be useful for diagnosis in cases where CC analysis failed to detect the Ph chromosome. RQ-PCR was helpful in detecting any residual disease and determining the depth of the treatment response at levels greater than the CC methods.

Squamous Cell Carcinoma and Basal Cell Carcinoma Simultaneously Arising in a Nevus Sebaceus: A Case Report (피지선 모반에서 동시에 발생한 편평세포암과 기저세포암)

  • Park, Hyun-Min;Lee, Dong-Geun;Shin, Kyung-Jin;Yoon, Tae-Young;Lee, Ji-Yeoun;Sung, Ro-Hyun;Song, Hyung-Geun;Lee, Dong-Wook;Lee, Eui-Tai
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.883-885
    • /
    • 2011
  • Purpose: Nevus sebaceus is a congenital hamartomatous lesion, typically involving head and neck. Various benign and malignant neoplasms can develop in association with nevus sebaceus. We report a case of simultaneous occurrence of squamous cell carcinoma and basal cell carcinoma in nevus sebaceus. Methods: A 73-year-old man presented with erythematous to black verrucous nodules on the right subauricular area. The upper part was accompanied with inflammation and ulceration, and no specific findings suspicious for malignant degeneration were found in the lower part preoperatively. The mass was totally excised and the defect was directly closed. Lymph nodes were not involved on concomitant neck dissection. Results: Histopathologic examination confirmed the presence of squamous cell carcinoma in the upper part and basal cell carcinoma in the lower part of a nevus sebaceus. Negative margins were achieved on resection. No clinical problems were found during the 3-month follow-up period. Conclusion: We experienced a rare case of simultaneous occurrence of squamous cell carcinoma and basal cell carcinoma within the same nevus sebaceus. Because patients with nevus sebaceus have risk of malignant changes, surgical excision and work-up for recurrence and metastasis should be considered in suspicious cases. And even in a totally asymptomatic case, the possibility of occult secondary cancer should be informed before surgery in aged patients.

Development of a Korean Adult Female Voxel Phantom, VKH-Woman, Based on Serially Sectioned Color Slice Images (고해상도 연속절단면 컬러해부영상을 이용한 한국인 성인여성 복셀팬텀 VKH-Woman 개발)

  • Jeong, Jong Hwi;Yeom, Yoen Soo;Han, Min Cheol;Kim, Chan Hyeong;Ham, Bo Kyoung;Hwang, Sung Bae;Kim, Seong Hoon;Lee, Dong-Myung
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.199-208
    • /
    • 2012
  • The computational human phantom including major radiation sensitive organs at risk (OARs) can be used in the field of radiotherapy, such as the variation of secondary cancer risks caused by the radiation therapy and the effective dose evaluation in diagnostic radiology. The present study developed a Korean adult female voxel phantom, VKH-Woman, based on serially sectioned color slice images of Korean female cadaver. The height and weight of the developed female voxel phantom are 160 cm and 52.72 kg, respectively that are virtually close to those of reference Korean female (161 cm and 54 kg). The female phantom consists of a total of 39 organs, including 27 organs recommended in the ICRP 103 publication for the effective dose calculations. The female phantom composes of $261{\times}109{\times}825$ voxels (=23,470,425 voxels) and the voxel resolution is $1.976{\times}1.976{\times}2.0619mm^3$ in the x, y, and z directions. The VHK-Woman is provided as both ASCII and Binary data formats to be conveniently implemented in Monte Carlo codes.

Experimental investigation of the photoneutron production out of the high-energy photon fields at linear accelerator (고에너지 방사선치료 시 치료변수에 따른 광중성자 선량 변화 연구)

  • Kim, Yeon Su;Yoon, In Ha;Bae, Sun Myeong;Kang, Tae Young;Baek, Geum Mun;Kim, Sung Hwan;Nam, Uk Won;Lee, Jae Jin;Park, Yeong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 2014
  • Purpose : Photoneutron dose in high-energy photon radiotherapy at linear accelerator increase the risk for secondary cancer. The purpose of this investigation is to evaluate the dose variation of photoneutron with different treatment method, flattening filter, dose rate and gantry angle in radiation therapy with high-energy photon beam ($E{\geq}8MeV$). Materials and Methods : TrueBeam $ST{\time}TM$(Ver1.5, Varian, USA) and Korea Tissue Equivalent Proportional Counter (KTEPC) were used to detect the photoneutron dose out of the high-energy photon field. Complex Patient plans using Eclipse planning system (Version 10.0, Varian, USA) was used to experiment with different treatment technique(IMRT, VMAT), condition of flattening filter and three different dose rate. Scattered photoneutron dose was measured at eight different gantry angles with open field (Field size : $5{\time}5cm$). Results : The mean values of the detected photoneutron dose from IMRT and VMAT were $449.7{\mu}Sv$, $2940.7{\mu}Sv$. The mean values of the detected photoneutron dose with Flattening Filter(FF) and Flattening Filter Free(FFF) were measured as $2940.7{\mu}Sv$, $232.0{\mu}Sv$. The mean values of the photoneutron dose for each test plan (case 1, case 2 and case 3) with FFF at the three different dose rate (400, 1200, 2400 MU/min) were $3242.5{\mu}Sv$, $3189.4{\mu}Sv$, $3191.2{\mu}Sv$ with case 1, $3493.2{\mu}Sv$, $3482.6{\mu}Sv$, $3477.2{\mu}Sv$ with case 2 and $4592.2{\mu}Sv$, $4580.0{\mu}Sv$, $4542.3{\mu}Sv$ with case 3, respectively. The mean values of the photoneutron dose at eight different gantry angles ($0^{\circ}$, $45^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$, $225^{\circ}$, $270^{\circ}$, $315^{\circ}$) were measured as $3.2{\mu}Sv$, $4.3{\mu}Sv$, $5.3{\mu}Sv$, $11.3{\mu}Sv$, $14.7{\mu}Sv$, $11.2{\mu}Sv$, $3.7{\mu}Sv$, $3.0{\mu}Sv$ at 10MV and as $373.7{\mu}Sv$, $369.6{\mu}Sv$, $384.4{\mu}Sv$, $423.6{\mu}Sv$, $447.1{\mu}Sv$, $448.0{\mu}Sv$, $384.5{\mu}Sv$, $377.3{\mu}Sv$ at 15MV. Conclusion : As a result, it is possible to reduce photoneutron dose using FFF mode and VMAT method with TrueBeam $ST{\time}TM$. The risk for secondary cancer of the patients will be decreased with continuous evaluation of the photoneutron dose.

The evaluation of properties for radiation therapy techniques with flattening filter-free beam and usefulness of time and economy to a patient with the radiation therapy (Flattening filter-free beam을 이용한 방사선 치료 기법의 특성 및 환자의 시간적.경제적 유용성 평가)

  • Goo, Jang Hyeon;Won, Hui Su;Hong, Joo Wan;Chang, Nam Jun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.363-368
    • /
    • 2014
  • Purpose : The aim of this study was to appraise properties for radiation therapy techniques and effectiveness of time and economy to a patient in the case of applying flattening filter-free (3F) and flattening filter (2F) beam to the radiation therapy. Materials and Methods : Alderson rando phantom was scanned for computed tomography image. Treatment plans for intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and stereotactic body radiation therapy (SBRT) with 3F and 2F beam were designed for prostate cancer. To evaluate the differences between the 3F and 2F beam, total monitor units (MUs), beam on time (BOT) and gantry rotation time (GRT) were used and measured with $TrueBeam^{TM}$ STx and Surveillance And Measurement (SAM) 940 detector was used for photoneutron emitted by using 3F and 2F. To assess temporal and economical aspect for a patient, total treatment periods and medical fees were estimated. Results : In using 3F beam, total MUs in IMRT plan increased the highest up to 34.0% and in the test of BOT, GRT and photoneutron, the values in SBRT plan decreased the lowest 39.8, 38.6 and 48.1%, respectively. In the temporal and economical aspect, there were no differences between 3F and 2F beam in all of plans and the results showed that 10 days and 169,560 won was lowest in SBRT plan. Conclusion : According as the results, total MUs increased by using 3F beam than 2F beam but BOT, GRT and photoneutron decreased. From above the results, using 3F beam can decrease intra-fraction setup error and risk of radiation-induced secondary malignancy. But, using 3F beam did not make the benefits of temporal and economical aspect for a patient with the radiation therapy.