• Title/Summary/Keyword: Secondary Air System

검색결과 272건 처리시간 0.026초

공기스프링 적용 철도차량의 동적 특성에 관한 연구 (A Study on the Dynamic Characteristics of Railway Rolling Stock Applied Air Aprings)

  • 허현무;함영삼;최경진;권성태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.171-178
    • /
    • 2001
  • Air spring for railway rolling-stock is a part of secondary suspension system which play the role of supporting load, damping vibration. Recently, air springs are actively applied to railway rolling-stock to substitute coil spring with upgrading the manufacturing skill. This study is started to get the fundamental datum related to air spring for the purpose of developing the test draft for air spring. To analyze the performance of air spring, we conducted the simulation for railway rolling-stock applied air spring and tested train in convention lines. Thus, we have obtained useful datum to develop the test draft for air spring. Here, we describe some results.

  • PDF

곡관덕트의 입구영역에서 천이비정상유동의 속도분포와 임계딘수에 관한연구 (A Study on Velocity Profiles and Critical Dean Number of Developing Transitional Unsteady Flows in a Curved Duct)

  • 이행남
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.862-870
    • /
    • 1998
  • In this paper an experimental investigation of characteristics of developing transitional unsteady flows in a square-sectional 180。 curved duct are presented. The experimental study using air is carried out to measure axial velocity profiles secondary flow velocity profiles and entrance length by using Laser Do ppler Velocimeter(LDV) system. The flow development is found to depend upon Dean number dimensionless angular frequency velocity amplitude ration and cur-vature ratio. Of special interest is the secondary flow generated by centrifugal effects in the plane of the cross-section of the duct. The secondary flows are strong and complicate at entrance region. The entrance length of transitional pulsating flow is obtained to 120。 of bended angle of duct in this experimental conditions.

  • PDF

200MW 석탄화력 순환 유동층 보일러 이차공기송풍기용 H-브릿지 멀티레벨 인버터 현장적용 (Field Application of H-Bridge Multi-level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan)

  • 김봉석;류호선
    • 전력전자학회논문지
    • /
    • 제12권5호
    • /
    • pp.424-431
    • /
    • 2007
  • 본 논문은 발전소의 이차공기송풍기를 가변 회전수 제어하여 소내 소비 전력을 절감하고 전동기의 직입기동에 의한 스트레스를 줄이기 위하여 실증 적용된 200MW 석탄화력 발전소 순환 유동층 보일러 이차 공기 송풍기 구동용 H-브릿지 멀티레벨 인버터에 관한 것이다. H-브릿지 멀티레벨 인버터는 독립적으로 절연된 직류 부를 갖는 저전압의 단상 인버터(셀 인버터)를 다수 직렬 접속하여 고전압 3상 전압을 출력하는 Cascaded H-브릿지 전압형 인버터이다. 전력연구원은 6.6kV, 1MVA급 인버터 개발, 발전소에 설치, 보일러 점화 전/후 시험 및 계통 병입 후 부하 시험 등을 국내 최초로 성공적으로 완료하였다. 현재 200MW 석탄화력 발전소 이차 공기 송풍기 구동용 인버터는 상업 운전 중에 있다. 본 논문에서는 개발된 H-브릿지 멀티레벨 인버터, 기존 발전 설비와 신규 인버터 시스템의 인터페이스 부분에 해당하는 보일러 DCS(Distributed Control System : 분산 제어 시스템) 로직, 계통 병입 후 시운전 결과에 대하여 상세히 기술하였다.

연소실 압력변동과 2차 연료분사가 화염안정화와 NOx 배출에 미치는 영향 (Influence of changing combustor pressure and secondary fuel injection on flame stabilization and NOx emission)

  • 김종률;최경민;김덕줄
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.128-133
    • /
    • 2006
  • Influence of changing combustor pressure on flame stabilization and nitrogen oxide (NOx) emission in the swirl-stabilized flame with secondary fuel injection was investigated. The combustor pressure was controlled by suction at combustor exit. Pressure index ($P{\ast}=P_{abs}/P_{atm}$), where $P_{abs}$ and $P_{atm}$ indicated the absolute pressure and atmosphere pressure, was controlled in the range of $0.7{\sim}1.3$ for each equivalence ratio conditions. The flammable limits of swirl flames were largely influenced by changing combustor pressure and they showed different tendency compared with laminar flames. Emission index showed maximum value near atmospheric condition and decreased with decreasing pressure index for overall equivalence ratio conditions. R.m.s of pressure fluctuations also showed similar tendency with nitric oxide emission. By injecting secondary fuel into flame zone, the flammable limits were extended significantly. Emission index of nitric oxide and r.m.s. of pressure fluctuations were also controlled by injecting secondary fuel. The swirl flames were somewhat lifted by secondary fuel with high momentum, hence low nitric oxide emission. This NOx reduction technology is applicable to industrial furnaces and air conditioning system by adopting secondary fuel injection.

  • PDF

공기다단 적용 석유코크스 연료 전용 연소기에 대한 실험적 연구 (An Experimental Study of Petroleum Cokes Air Staged Burner)

  • 권민준;이창엽;김세원
    • 한국연소학회지
    • /
    • 제20권2호
    • /
    • pp.40-45
    • /
    • 2015
  • This study is aimed to study combustion characteristics of low $NO_X$ burner using petroleum cokes as fuel. The petroleum coke, which is produced through the oil refining process, is an attractive fuel in terms of its high heating value and relatively low price. But petroleum coke is a challenging fuel because of its low volatile content, high sulfur and nitrogen content, which give rise to undesirable emission characteristics and low ignitability. The petroleum cokes burner is operated at fuel rich condition, and overfire air are supplied to achieve fuel lean condition. The low $NO_X$ burner is designed to control fuel and air mixing to achieve air staged combustion, in addition secondary and tertiary air are supplied through swirler. Air distribution ratio of triple staged air are optimized experimentally. The result showed that $NO_X$ concentration is lowest when overfire air is used, and the burner function at a fuel rich condition.

현대 FFV(Flexible Fuel Vehicle) 개발 (Research and development of Hyundai FFVs(flexible fuel vehicles))

  • 명차리;이시훈;박광서;박심수
    • 오토저널
    • /
    • 제14권6호
    • /
    • pp.67-73
    • /
    • 1992
  • This paper describes Hyundai's research and development work on a flexible fuel vehicle (FFV). The work on FFV has been conducted to evaluate its potential as an alternative to the conventional gasoline vehicle. Hyundai FFV described here can be operated on M85, gasoline, or any of their combinations, in which the methanol concentration is measured by an electrostatic type fuel sensor. For that operation, a special FFV ECU(Eletronic Control Unit) has been developed and incorporated in the FFV. The characteristics affecting FFV operation, such as FFV ECU control strategy and injector flow rate, have been investigated and optimized through the experiment. And various development tests have been performed in view of engine performance, durability, cold startability, and exhaust emissions reduction. The exhaust gas aftertreatment system consisting of manifold type catalyst and secondary air injection system shows good emission reduction performance including formaldehyde, and finally, the possibility of the FFVs as the low emission vehicles is evaluated by presenting NMOG(Non-Methane Organic Gases) levels with respect to M0 and M85. With these results, it is concluded that FFV can be a candidate for the low emission vehicles, but more works on its durability improvement is required.

  • PDF

LES에 의한 PAC용 시로코홴의 3차원 전산유동해석 (Three-Dimensional Computational Flow Analysis of a Sirocco Fan for a Package Air Conditioner by LES)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제16권4호
    • /
    • pp.51-59
    • /
    • 2012
  • The computational flow analysis using LES technique was carried out to investigate the flow characteristics of a sirocco fan under the maximum flowrate condition. The commercial SC/Tetra software was used for this unsteady and three-dimensional numerical analysis. In consequence, because a flow is unstable within the range of about 50% of a housing depth from a bellmouth around the cutoff region, the passing flow through the blade cascade occurred on the X-Y plane is a slow or a reverse with approaching to the housing inlet. Also, the secondary flow shows on the radial plane of a housing, and its vortex center exists within about 33% of a housing depth from a bellmouth except the cutoff region. Moreover, the flow occurring on the exit plane of a sirocco fan shows a complex secondary flow.

자기부상/추진 일체화를 위한 선형 스위치드 릴럭턴스 모터의 모델링 (Modeling of Linear Switched Reluctance Motor for Self Levitation and Propulsion)

  • 성소영;조한욱;성호경;장석명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.95-97
    • /
    • 2007
  • This paper proposes a mathematical modelling about Leviation Force and Propulsion Force in a system, where Primary and Secondary LSRM air-gap is irregular. This can be a suitable model for Magnetically levitation Train, where Primary and Secondary air-gap mechanically has to control simultaneously Levitation Force and Propulsion Force.

  • PDF

Measurement of ion induced secondary electron emission $coefficient({\gamma})$ and work function of vacuum annealed MgO protective layer in AC PDP

  • Lim, J.Y.;Jeong, H.S.;Park, W.B.;Oh, J.S.;Jeong, J.M.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.799-801
    • /
    • 2003
  • The secondary electron emission $coefficient({\bullet})$ of vacuum annealed MgO films has been investigated by ${\bullet}$ -focused ion beam(${\bullet}$ -FIB) system. The vacuum annealed MgO films have been found to have higher ${\bullet}$ values than those for as-deposited MgO films for Ne+ ion. Also it is found that the ${\bullet}$ for air-hold of vacuum annealed MgO layers for 24-hours is similar to that for vacuum annealed MgO films without any air-hold.

  • PDF

지역난방 2차측 공급수 온도 제어방안(설정온도 제어, 외기온 보상제어, 외기온 예측제어)에 따른 에너지사용량 실증 비교 (Actual Energy Consumption Analysis on Temperature Control Strategies (Set-point Control, Outdoor Temperature Reset Control and Outdoor Temperature Predictive Control) of Secondary Side Hot Water of District Heating System)

  • 조성환;홍성기;이상준
    • 설비공학논문집
    • /
    • 제27권3호
    • /
    • pp.137-145
    • /
    • 2015
  • In this study, the actual energy consumption of the secondary side of District Heating System (DHS) with different hot water supply temperature control methods are compared. Three methods are Set-point Control, Outdoor Temperature Reset Control and Outdoor Temperature Prediction Control. While Outdoor Temperature Reset Control has been widely used for energy savings of the secondary side of the system, the results show that Outdoor Temperature Prediction Control method saves more energy. In general, Outdoor Temperature Prediction Control method lowers the supply temperature of hot water, and it reduces standby losses and increases overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, Outdoor Temperature Prediction Control method saves about 7.1% in comparison to Outdoor Temperature Reset Control method and about 15.7% in comparison to Set-point Control method. Also, it is found that at when partial load condition, such as daytime, the fluctuation of hot water supply temperature with Set-point Control is more severe than Outdoor Temperature Prediction Control. Therefore, it proves that Outdoor Temperature Prediction Control is more stable even at the partial load conditions.