서울시 PM10 내의 수용성 유기탄소와 수분함량과의 상관성 분석 (The Relationship between the Estimated Water Content and Water Soluble Organic Carbon in PM10 at Seoul, Korea)

  • 이승하;김용표;이지이;이승묵
    • 한국대기환경학회지
    • /
    • 제33권1호
    • /
    • pp.64-74
    • /
    • 2017
  • In this study, we have analyzed relationship between the measured Water Soluble Organic Carbon (WSOC) concentrations and the estimated aerosol water content of $PM_{10}$ (particulate matter with an aerodynamic diameter of less than or equal to $10{\mu}m$) for the period between September 2006 and August 2007 at Seoul, Korea. Water content of $PM_{10}$ was estimated by using a gas/particle equilibrium model, Simulating composition of Atmospheric Particles at Equilibrium 2 (SCAPE2). The WSOC concentrations showed low correlation with Elemental Carbon (EC), but Water Insoluble Organic Carbon (WISOC) were highly correlated with EC. It seemed that hydrophilic groups were produced by secondary formation rather than primary formation. As with the previous studies, WSOC showed good correlation with secondary ions ($NO_3{^-}$, $SO_4{^{2-}}$, $NH_4{^+}$), especially WSOC was highly correlated with $NO_3{^-}$ that is a secondary ion formed by photochemical oxidation from more local sources than $SO_4{^{2-}}$. No apparent correlation between the measured WSOC and estimated water content was observed. However, WSOC showed good correlation with estimated water content when it was assumed that relative humidity was higher than the deliquescence relative humidity of the system. In conclusion, WSOC is correlated with water content by hygroscopic ions and it is expected that nitrate play an important role among the water content and WSOC.

하수 처리 및 재활용 연못시스템의 국내 응용 (Application of a Pond System to Korea for Treatment and Recycling of Wastewater)

  • 양홍모
    • 상하수도학회지
    • /
    • 제9권2호
    • /
    • pp.108-117
    • /
    • 1995
  • 연못시스템의 처리정도는 기후조건(氣候條件)과 아주 밀접한 관계가 있다. 기존시스템이 없는 경우 비슷한 기후권의 사례지역을 반드시 비교분석하게 된다. 미국 온대권에 위치한 Corinne과 Eudora 시스템의 기온과 태양복사량을 김포지역과 비교한 결과 아주 유사함이 규명되었다. 특히 태양복사열의 경우, 여름철에 김포지역이 두 시스템보다 조류성장에 유리한 조건이다. 국내 중부지방에 Corinne과 Eudora 시스템과 비슷한 연못시스템을 설치운영(設置運營)하는 데는 문제점이 없음을 알 수 있다. 남부지방은 연중기온이 김포지역보다 높으므로 연못시스템의 이용이 김포지역보다 유리하다. 미국에서는 연못시스템이 2차처리시설(次處理施設)로 합법화되어 있으며, 2차처리 수질기준(水質基準)을 충족시키고 있다. Corinne과 Eudora 연못시스템의 처리수준을 분석한 결과 처리수의 $BOD_5$ 가 30mg/l 이하로 처리되고 있으나, SS 농도가 30mg/l 보다 다소 높은 경우가 있다. Eudora시스템에서 4월에 일어나는 연못하수의 회전기간(回轉期間)을 제외하고는 연못시스템에 적용하는 처리수의 SS기준인 70-100mg/l 이내로 처리되고 있다. 우리나라 중부지방에 Corinne과 Eudora 시스템과 유사한 연못처리시스템을 설치(設置)하면 2차 처리수준으로 하수를 처리할 수 있을 것으로 판단된다. 연못시스템은 양어, 작물생산, 레크레이션이용과 결합시킬 수 있어, 국내의 경우 농촌소도시 지역, 도시경계 생산녹지지역, 내륙 및 하구의 저습지(wetland)에서 소형뿐아니라 대형 시스템으로 활용이 가능하다.

  • PDF

에너지슬래브 지중열교환기의 성능 분석 (Performance Analysis of Energy-Slab Ground-Coupled Heat Exchanger)

  • 최종민;손병후
    • 설비공학논문집
    • /
    • 제24권6호
    • /
    • pp.487-496
    • /
    • 2012
  • Recently, utilization of building foundations as ground-coupled heat exchangers has attracted much attention because they reduce the cost and enhance the heat transfer. The objective of this study is to evaluate the performance of energy-slab ground-coupled heat exchanger installed in a commercial building. In order to demonstrate the energy transfer characteristics of the energy-slab, experiments were conducted from October 2010 to September 2011. The 1-year measurement results showed that the mean EWTs of brine returning from the energy-slab were $9.6^{\circ}C$ in heating season and $24.9^{\circ}C$ in cooling season, which were in a range of design target temperatures. In addition, the geothermal heat pump system with the energy-slab showed on-off operation according to the setting temperatures of secondary fluid in water storage tank. The results also showed that the energy-slab extracted heat of 198.6 kW from the ground and injected heat of 318.9 kW to the ground, respectively.

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.104-104
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate. A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side is installed in the form of coolant block around vertical tube and the heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 15 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348 -3.282kg/hr, of inlet air mass fraction 11.8 -55.0%. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the decrease of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed represented with the 165 sets of local heat transfer data. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17. 7% between the results by the experiment and by the correlation.

  • PDF

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • Nuclear Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.486-497
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate, A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side has a shape of annulus around vertical tube and the lost heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 11 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348∼3.282kg/hr, of inlet air mass fraction 11.8∼55.0%. The investigation of the flooding is preceded to find the upper limit of the reflux condensation. Onset of flooding is lower than that of Wallis' correlation. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the increase of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed by 165 data of the local heat transfer. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17.7% between the results by the experiment and by the correlation.

  • PDF

체내 이식형 인공심장의 무선에너지 전송 시스템에 관한 기초적 연구 (The basic research of transcutaneous energy transmission system for totally implantable artificial heart)

  • 김정한;김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.407-410
    • /
    • 2002
  • As a part of electro-mechanical totally implantable artificial heart, a transcutaneous energy transmission system has been developed. By mutual magnetic induction between the first coil on the skin and the subcutaneously implanted second coil, the system transfers electrical power through the skin. This research aimed a minimizing the size of the implanted part as well as maximizing the transfer efficiency. When an air gap is 1$\sim$2cm, voltage gain and current gain low and it is hard to transfer energy due to large leakage flux. That is, the required input voltage and input current must be large compared with the output voltage and output current, respectively, This paper research the inverter topology and the control method in order to increase the voltage gain and the current gain. For this purpose, this inverter employs double tune to compensate the large leakage inductance of primary and secondary of the transcutaneous transformer. And the output energy of transcutaneous energy transmission system supply for Lithium-ion battery charger.

  • PDF

열분해 용융 소각로 설계인자 도출을 위한 수치해석적 연구 (A numerical study on design parameters of pyrolysis-melting incinerator)

  • 신동훈;전병일;이진호;황정호;류태우;박대규
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.243-250
    • /
    • 2003
  • The present study discuss about numerical methods to analyze design parameters of pyrolysis-melting incineration system. Various numerical methods of different viewpoint are introduced to simulate the performance of the system. Process analysis of the overall system is the beginning procedure of basic design process. Heat and material flow of each element are connected and are influential to each other, hence, an appropriate process modeling should be executed to prevent from unacceptable process design concepts that may results in system failure. Models to simulate performance of each elementary facility generate valuable informations on design and operation parameters, and, derive the basic design concept to be optimized. A pyrolysis model derived from waste bed combustion model is introduced to simulate the mass conversion and heat transfer in the pyrolysis process. CFD(Computational fluid dynamics) is an effective method to optimize the thermal reacting flow in various reactors such as combustor and heat exchanger. Secondary air jets arrangement and the shape of the combustor could be optimized by CFD technology.

  • PDF

태양에너지 이용 저압 증발식 해수 담수시스템 이젝터 CFD 해석 (Analysis of the ejector for low-pressure evaporative desalination system using solar energy)

  • 황인선;주홍진;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.137-143
    • /
    • 2010
  • In this study, the ejector design was modeled using Fluent 6.3 of FVM(Finite Volume Method) CFD(Computational Fluid Dynamics) techniques to resolve the flow dynamics in the ejector. A vacuum system with the ejector has been widely used because of its simple construction and easy maintenance. Ejector is the main part of the desalination system, of which designs determine the efficiency of system. The effects of the ejector was investigated geometry and the operating conditions in the hydraulic characteristics. The ejector consists mainly of a nozzle, suction chamber, mixing tube(throat), diffuser and draft tube. Liquid is supplied to the ejector nozzle, the fast liquid jet produced by the nozzle entrains and the non condensable gas was sucked into the mixing tube. In the present study, the multiphase CFD modeling was carried out to determine the hydrodynamic characteristics of seawater-air ejector. Two-dimensional geometry was considered with the quadrilateral-mashing scheme. The gas suction rate increases with increasing Motive flow circulating rate.

개선된 기능을 갖는 능동 레이더 반사기 개발에 관한 연구 (A Study on the Development of the Active Radar Reflector with Enhanced Function)

  • 정종혁;강상욱;조영창;최병진;윤정오;오주환
    • 한국산업정보학회논문지
    • /
    • 제5권3호
    • /
    • pp.38-43
    • /
    • 2000
  • 능동 레이더 반사기는 지금까지는 특히 비행물체와 미사일의 레이더 유효 반사 면적을 효과적으로 증가시키기 위한 군사적 응용에만 사용이 제한되어져 왔기 때문에 그다지 친숙한 용어는 아니다. 레이더 트랜스폰더의 가장 잘 알려진 응용은 군용의 피아 식별 장치 (IFF ; Identification Friend or Foe)와 이것의 민간 항공부문이고, 항공 교통 관제(ATC : Air Traffic Control)를 위한 2차 감시 레이더(SSR ; Second Surveillance: Radar), 그리고 보다 최근에는 전 세계 해상 조난 및 안전 제도(GMDSS : Global Maritime Distress and Safety System)의 수색 구조용 트랜스폰더(SART : Search And Rescue Transponder)등이 있다. 최근 연안이나 대양에서의 해난사고가 빈번히 발생되고 있으므로, 이로 인한 해양오염이 심각한 실정이다. 이제는 전통적인 항해표지 및 시설로써 해상교통의 안전을 유지하기에는 충분치 못하며 새로운 개념과 구조가 적용되어야만 한다. 따라서 본 연구에서는 개선된 기능을 가지는 능동 레이더 반사기를 제안하고 제작하였다. 제작된 시스템은 기존의 시설에 비해 높은 성능 향상을 보인다.

  • PDF

정사각단면 $180^{\circ}C$ 곡덕트에서 층류진동유동의 유동 특성에 관한 연구 (A study on flow characteristics of laminar oscillatory flows in a square-sectional $180^{\circ}C$ curved duct)

  • 박길문;조병기;봉태근
    • 대한기계학회논문집B
    • /
    • 제22권2호
    • /
    • pp.139-152
    • /
    • 1998
  • In the present study, the flow characteristics of developing laminar oscillatory flows in a square -sectional 180 deg. curved duct are investigated experimentally. The experimental study using air in a square-sectional 180 deg. curved duct is carried out to measure velocity distributions with a data acquisition and LDV (Laser Doppler Velocimetry) processing system. In this system, Rotating Machinery Resolver (RMR) and PHASE program are used to obtain the results of unsteady flows. The major flow characteristics of developing oscillatory flows are found by analyzing velocity curves, mean velocity profiles, time-averaged velocity distribution of secondary flow, wall shear stress distributions, and entrance lengths. In a lower dimensionless angular frequency, the axial velocity distribution of laminar oscillatory flow in a curved duct shows a convex shape in a central part and axial symmetry. The maximum value of wall shear stress in a lower dimensionless angular frequency is located in an outside wall, but according to increasing the dimensionless angular frequency, the maximum of wall shear stress is moved to inner wall. The entrance lengths of laminar oscillatory flows in a square-sectional 180 deg. curved duct is obtained to 90 deg. of bended angle of duct in this experimental conditions.