• Title/Summary/Keyword: Second premolar

Search Result 349, Processing Time 0.023 seconds

THE STUDY ON THE MICROLEAKAGE OF THE RESTORATION WITH SELF-ETCHING PRIMING/BONDING AGENT (Self-etching priming/bonding agent를 이용한 수복에서 microleakage에 관한 연구)

  • Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.26-33
    • /
    • 2004
  • Self-etching priming bonding system was recently developed in order to simplify the clinical skills & save chair time after continuous improvements on dentin bonding agents. To test the magnitude of microleakage of a new "self-etching priming bonding agent" using sound premolar 4th, 5th, 6th generation dentin bonding agent was applied. Measure the magnitude of infiltration to the gap of enamel-restoration interface and dentin-restoration interface. After bonding of composite resin to sample surfaces according to the manufactures direction and 500 times thermocycling on dwell time 30 second, and microleakage was measured by the ratio of the depth to the axial wall and the magnitude of infiltration. Afterward analyzed by ANOVA test. The result were as follows ; 1. Enamel groups showed lesser microleakage (Group I, II, III, IV) than dentin groups(Group V, VI, VII, VIII). (p<0.05) 2. There are no statical differences among the dentin groups, in enamel groups, group IV showed more microleakage than group I, II, III. (p<0.05). For a clinical acceptance, better enamel marginal adaptation is required.

  • PDF

A CEPHALOMETRIC STUDY ON MESIODISTAL AXIAL INCLINATION OF POSTERIOR TEETH IN OPEN BITE AND DEEP BITE (개방교합과 과개교합에서 구치의 근원심 치축경사도에 관한 두부방사선계측학적 연구)

  • Jeon, Sang-Beom;Kim, Jin-Beom;Shon, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.23 no.3 s.42
    • /
    • pp.391-403
    • /
    • 1993
  • For the purpose of investigating mesiodistal axial inclination of posterior teeth in normal occlusion group, open bite and deep bite group and investigating the correlationship between the axial inclination of posterior teeth and overbite of anterior teeth, a cephalometric study was performed on the subjects consisted of normal occlusion group(40), open bite group(71 : Angle's Class I, Class II, division 1 25, Class III 25) and deep bite group(64 : Angle's Class I 23, Class II, division 1 21, Class III 20). Mesiodistal axial inclination of posterior teeth to occlusal, mandibular and palatal plane were measured. The findings of this study were as follows : 1. Upper and lower posterior teeth were more mesially inclined to occlusal plane in open bite group than in deep bite group. 2. Lower posterior teeth were more mesially inclined in deep bite group than in open bite group in Angle's Class II, division 1 malocclusion but there were no significant differences in Angle's Class I and Class III malocclusion. 3. There was no significant correlationship between the axial inclination of posterior teeth to each plane and overbite of anterior teeth in open bite group. 4. There was a significant correlationship between the axial inclination of upeer and lower second premolar to occlusal plane and overbite of anterior teeth in Angle's Class I, Class II, division 1 and Class III malocclusion.

  • PDF

Quantitative evaluation of alveolar cortical bone density in adults with different vertical facial types using cone-beam computed tomography

  • Ozdemir, Fulya;Tozlu, Murat;Cakan, Derya Germec
    • The korean journal of orthodontics
    • /
    • v.44 no.1
    • /
    • pp.36-43
    • /
    • 2014
  • Objective: The purpose of this study was to quantitatively evaluate the cortical bone densities of the maxillary and mandibular alveolar processes in adults with different vertical facial types using cone-beam computed tomography (CBCT) images. Methods: CBCT images (n = 142) of adult patients (20-45 years) were classified into hypodivergent, normodivergent, and hyperdivergent groups on the basis of linear and angular S-N/Go-Me measurements. The cortical bone densities (in Hounsfield units) at maxillary and mandibular interdental sites from the distal aspect of the canine to the mesial aspect of the second molar were measured on the images. Results: On the maxillary buccal side, female subjects in the hyperdivergent group showed significantly decreased bone density, while in the posterior region, male subjects in the hyperdivergent group displayed significantly decreased bone density when compared with corresponding subjects in the other groups (p<0.001). Furthermore, the subjects in the hyperdivergent group had significantly lower bone densities on the mandibular buccal side than hypodivergent subjects. The maxillary palatal bone density did not differ significantly among groups, but female subjects showed significantly denser palatal cortical bone. No significant difference in bone density was found between the palatal and buccal sides in the maxillary premolar region. Overall, the palatal cortical bone was denser anteriorly and buccal cortical bone was denser posteriorly. Conclusion: Adults with the hyperdivergent facial type tend to have less-dense buccal cortical bone in the maxillary and mandibular alveolar processes. Clinicians should be aware of the variability of cortical bone densities at mini-implant placement sites.

What is the changing frequency of diamond burs?

  • Emir, Faruk;Ayyildiz, Simel;Sahin, Cem
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.93-100
    • /
    • 2018
  • PURPOSE. The purpose of this study was to determine the changing frequency of a diamond bur after multiple usages on 3 different surfaces. MATERIALS AND METHODS. Human premolar teeth (N = 26), disc shaped direct metal laser sintered CoCr (N = 3) and zirconia specimens (N = 3) were used in this study. Groups named basically as Group T for teeth, Group M for CoCr, and Group Z for zirconia. Round tapered black-band diamond bur was used. The specimens were randomly divided into three groups and placed with a special assembly onto the surveyor. 1, 5, and 10 preparation protocols were performed to the first, second, and third sub-groups, respectively. The subgroups were named according to preparation numbers (1, 5, 10). The mentioned bur of each group was then used at another horizontal preparation on a new tooth sample. The same procedure was used for CoCr and zirconia disc specimens. All of the bur surfaces were evaluated using roughness analysis. Then, horizontal tooth preparation surfaces were examined under both stereomicroscope and SEM. The depth maps of tooth surfaces were also obtained from digital stereomicroscopic images. The results were statistically analyzed using One-Way ANOVA, and the Tukey HSD post-hoc tests (${\alpha}=.05$). RESULTS. All of the groups were significantly different from the control group (P<.001). There was no significant difference between groups Z5 and Z10 (P=.928). Significant differences were found among groups T5, M5, and Z5 (P<.001). CONCLUSION. Diamond burs wear after multiple use and they should be changed after 5 teeth preparations at most. A diamond bur should not be used for teeth preparation after try-in procedures of metal or zirconia substructures.

Accuracy of new implant impression technique using dual arch tray and bite impression coping

  • Lee, Shin-Eon;Yang, Sung-Eun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.265-270
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at ${\alpha}=.05$. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.

SCISSOR BITE CORRECTION IN PATIENTS WITH WILLAMS SYNDROME: A CASE REPORT (Williams Syndrome 환자에서의 scissor bite correction: 증례보고)

  • Ji, Eun-Hye;Choi, Hyung-Jun;Kim, Seong-Oh;Son, Heung-Kyu;Lee, Jae-Ho
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.7 no.1
    • /
    • pp.21-24
    • /
    • 2011
  • Williams syndrome(WS) is a congenital disorder caused by a deletion of the Elastin gene and other contiguous genes at chromosome 7. Patients with WS are at a high risk of dental caries, and they also have a higher frequency of dental malocclusion compared to normal children. Malocclusion occurs in 85% of individuals with WS, which results from combined causes, such as tongue thrust, hypotonia, and connective tissue abnormality. An 11 year-old girl with WS presented scissor bite on the lower right second premolar and the first molar, and she complained of difficulty in chewing. Active lingual arch was used instead of removable appliance, considering the patient's cooperation ability. Unilateral posterior scissor bite was corrected in 7 months. Although patients with WS are sociable and friendly, dental treatment can be a fearful experience for them. Efforts to build rapport with the patients with WS resulted in improved relationship between the doctor and patient, and desired outcome of dental treatment was achieved with patient's improved cooperation.

Influence of the material for preformed moulds on the polymerization temperature of resin materials for temporary FPDs

  • Pott, Philipp-Cornelius;Schmitz-Watjen, Hans;Stiesch, Meike;Eisenburger, Michael
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.294-301
    • /
    • 2017
  • PURPOSE. Temperature increase of $5.5^{\circ}C$ can cause damage or necrosis of the pulp. Increasing temperature can be caused not only by mechanical factors, e.g. grinding, but also by exothermic polymerization reactions of resin materials. The aim of this study was to evaluate influences of the form material on the intrapulpal temperature during the polymerization of different self-curing resin materials for temporary restorations. MATERIALS AND METHODS. 30 provisonal bridges were made of 5 resin materials: Prevision Temp (Pre), Protemp 4 (Pro), Luxatemp Star (Lux), Structure 3 (Str) and an experimental material (Exp). Moulds made of alginate (A) and of silicone (S) and vacuum formed moulds (V) were used to build 10 bridges each on a special experimental setup. The intrapulpal temperatures of three abutment teeth (a canine, a premolar, and a molar,) were measured during the polymerization every second under isothermal conditions. Comparisons of the maximum temperature ($T_{Max}$) and the time until the maximum temperature ($t_{TMax}$) were performed using ANOVA and Tukey Test. RESULTS. Using alginate as the mould material resulted in a cooling effect for every resin material. Using the vacuum formed mould, $T_{Max}$ increased significantly compared to alginate (P<.001) and silicone (P<.001). In groups Lux, Pro, and Pre, $t_{TMax}$ increased when the vacuum formed moulds were used. In groups Exp and Str, there was no influence of the mould material on $t_{TMax}$. CONCLUSION. All of the mould materials are suitable for clinical use if the intraoral application time does not exceed the manufacturer's instructions for the resin materials.

A CASE REPORT ABOUT CORRECTION OF IMPLANT POSITION AT HORIZONTAL PLANE AFTER CORTICOTOMY (피질골 절단술을 이용한 수평면에서의 임플란트의 위치 교정에 대한 치험례)

  • Choi, Bin;Oh, Hae-Soo;Kim, Jin-Chul;Kil, Yong-Gab;Kim, Kyoung-Soo;Kim, Jwa-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • Preface: Dental implant is important method that may solve the mastication, occlusion, esthetic, temporomandibular joint, and psychologic problem in oral and maxillofacial surgery. It is ideal that all of the implant are well positioned by adequate technique. By the way it‘s not always possible because of some anatomic, physiologic factor. In this case, If the implant can be moved to adequate position, it may be possible more esthetically and implanted patients more satisfied, but the majority of Implantists and orthodontists have thought that it is not possible. However, Implant, in fact, can be moved. and thus we can overcome the limit of implantation more. The aim of the present study was to evaluate the possibility of implant movement after corticotomy. Case report: Patient missed the upper right first molar. and implantation was done after completion of socket healing. We wait six months for osseointegration. Then, corticotomy was done under local anesthesia and close coil was used for orthodontic force. After traction during 3 weeks, we find the change of implant position at horizontal plane. we can not see the degenerative change on adjacent structure and tracted implant. there is a clinical mobility on upper right second premolar that used for anchorage but it subside spontaneously at the timing of prosthetic restoration without additional treatment. Discussion: As we could have some knowledge with this experiment, we report the case of implant movement after corticotomy and suggest a method about more esthetic implant treatment with a review of literature.

EVALUATION AND DEVELOPMENT OF DIGITAL DEVICE FOR MEASURING PROXIMAL TOOTH CONTACT TIGHTNESS (디지털 방식의 인접면 접촉강도 측정장치의 개발 및 평가)

  • Choi, Woo-Jin;Kim, Kyung-Hwa;Kim, Jin-A;Kang, Dong-Wan;Oh, Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.687-695
    • /
    • 2007
  • Statement of problem: The proper contact relation between adjacent teeth in each arch plays an important role in the stability and maintenance of the integrity of the dental arches. Proximal contact has been defined as the area of a tooth that is in close association, connection, or touch with an adjacent tooth in the same arch. Purpose: The aim of this study was to develop a digital device for measuring the proximal tooth contact tightness by pulling a thin stainless steel strip (2mm wide, 0.03mm thick) inserted between proximal tooth contact. Material and method: This device consists of measuring part, sensor part, motor part and body part. The stainless steel strip was connected to a stain gauge. The strain gauge was designed to convert the frictional force into a compressive force. This compressive force was detected as a electrical signal and the electrical signal was digitalized by a A/D converter. The digital signals were displayed by a micro-processor. The pulling speed was 8mm/s. Results: For testing reliability of the device in vivo, two healthy young adults (A, B) participated in this experiment. The tightness of proximal tooth contact between the second premolar and the first molar of mandible (subject A) and maxilla (subject B) was measured fifteen times for three days at rest. We double-checked the accuracy of the device with a Universal Testing Machine. Output signals from the Universal Testing Machine and the measuring device were compared. Regression analysis showed high linearity between these two signals. In vivo test, no significant differences were found between measurements. Conclusion: This device has shown to he capable of producing reliable and reproducible results in measuring proximal tooth contact. Therefore, it was considered that this device was appropriate to apply clinically.

Esthetic evaluation of maxillary single-tooth implants in the esthetic zone

  • Cho, Hae-Lyung;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.4
    • /
    • pp.188-193
    • /
    • 2010
  • Purpose: The aim of this study is to assess the influence exerted by the observer's dental specialization and compare patients' opinion with observers' opinion of the esthetics of maxillary single-tooth implants in the esthetic zone. Methods: Forty-one adult patients, who were treated with a single implant in the esthetic zone, were enrolled in this study. Eight observers (2 periodontists, 2 prosthodontists, 2 orthodontists and 2 senior dental students) applied the pink esthetic score (PES)/white esthetic score (WES) to 41 implant-supported single restorations twice with an interval of 4 weeks. We used a visual analog scale (VAS) to assess the patient's satisfaction with the treatment outcome from an esthetic point of view. Results: In the PES/WES, very good and moderate intraobserver agreements were noted between the first and second rating. The mean total PES/WES was $11.19{\pm}3.59$. The mean PES was $5.17{\pm}2.29$ and mean WES was $6.02{\pm}1.96$. In the total PES/WES, the difference between the groups was not significant. However, in the WES, the difference between the groups was significant and prosthodontists were found to have assigned poorer ratings than the other groups. Periodontists gave higher ratings than prosthodontists and senior dental students. Orthodontists were clearly more critical than the other observers. The statistical analysis revealed statistically significant correlation between patients' esthetic perception and dentists' perception of the anterior tooth. However, the correlation between the total PES/WES and the VAS score for the first premolar was not statistically significant. Conclusions: The PES/WES is an objective tool in rating the esthetics of implant supported single crowns and adjacent soft tissues. Orthodontists were the most critical observers, while periodontists were more generous than other observers. The statistical analysis revealed a statistically significant correlation between patients' esthetic perception and dentists' perception of the anterior tooth.