• 제목/요약/키워드: SecY

검색결과 5,778건 처리시간 0.053초

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.

전자현미분석기를 이용한 저어콘 및 모나자이트의 화학적 연대 측정법 (Chemical Age Dating of Zircon and Monazite by E1ectron Microprobe)

  • 이석훈
    • 암석학회지
    • /
    • 제10권3호
    • /
    • pp.179-189
    • /
    • 2001
  • 전자현미분석 기를 이용한 저어콘 및 모나자이트의 화학적 연대측정은 미량의 U, Th 및 Pb의 정량분석을 통해 이루어지는데, 측정에 이용되는 M-line의 특성 X-선은 발생효율이 낮고 피크강도가 작아 측정하한과 오차범위가 고려된 분석조건이 설정 되어야한다. 총 분석시간을 줄이고, 측정조건의 변위에 따른 오차를 감소시키고자 PET결정을 갖춘 3개의 분광기를 이용하여 U, Th 및 Pb를 동시에 측정하였고, 파고분석기를 이용하여 피크/배경 비율을 증가시켜 측정하한을 낮추었다 최적 분석조건하에서 U, Th 및 Pb에 대한 이론적 값인 측정하한을 30 ppm (99%유의수준)까지 낮출 수 있었고. 저어콘의 단일측정 시 800 ppd의 Pb농도에서 $\pm$10% ($2{\sigma}$), 2330 ppm의 U에서 $\pm$5% ($2{\sigma}$) 그리고 측정된 연대에서 $\pm$10% ($2{\sigma}$)이내의 상대오차범위에서 분석결과를 얻었다. 저어콘 및 모나자이트의 연대측정을 수행하는데 있어, 3 $\mu\textrm{m}$ 이하의 공간분해능, 100 ppm ($3{\sigma}$) 이하의 측정하한과 $\pm$10% ($2{\sigma}$) 이하의 분석오차를 고려한 가속전압은 15~20 keV, 빔 전류는 100~200 nA, 그리고 총 측정시간을 300~l200초 (피크와 배경위치에서 각각 동일한 시간으로 측정)로 설정하여 보다 정밀하고 정확한 분석자료를 얻을 수 있었다. 높은 전류에 따른 시료의 손상을 줄이기 위해선 전자빔 직경을 3~5 $\mu\textrm{m}$로 증가시키거나 보다 짧은 시간동안의 측정을 반복하여 그 평균값을 이용하는 것이 필요하다. 빔 전류를 증가시키거나 분석시간을 늘려 측정하한을 낮추고 정밀도를 향상시킴으로서 보다 젊은 시기의 암석이나 상대적으로 U, Th 및 Pb의 함량이 적은 광물의 연대측정에 이용할 수 있다.

  • PDF

메추리 원시생식세포 감소를 위한 감마선 조사의 효과 (Effects of Gamma-Irradiation on the Sterilization of Primordial Germ Cells in Quail)

  • 박경제;김태민;이형철;장현준;송권화;한재용
    • 한국가금학회지
    • /
    • 제37권2호
    • /
    • pp.139-143
    • /
    • 2010
  • 조류의 원시생식세포는 수용체 배자로의 주입을 통해서 생식선 카이메라 생산을 가능하게 하기 때문에 유전자 도입에 매우 효율적인 도구이다. 특히, 메추리는 성성숙이 빠르며 산란능력이 뛰어 나기 때문에 형질전환 조류 생산과 유전자 기능 연구에 매우 적합하다. 형질전환 조류 생산 효율을 높이기 위해서는 수용체 배자 내의 원시생식세포의 수를 줄이는 것이 필수적인 요소이지만, 아직까지 메추리에서 이러한 시도를 했다는 보고는 없다. 본 연구는 감마선 조사가 수용체 내의 원시생식세포의 수를 감소시킬 수 있는지 알아보았다. 먼저 0, 250, 500, 750, 1,000 rads 강도의 감마선을 갓 산란된 메추리알에 조사 후 5일령 배자에서 기형 발생빈도를 측정하였고, 0과 500 rads에서 17일째 부화율을 검정하였다. 그리고 500 rad의 감마선을 산란된 알에 73초간 조사 후 5일간 배양시킨 뒤 원시생식세포의 수를 측정하였다. 그결과, $1{\times}10^4$개의 세포 당 원시생식세포의 수는 수컷은 $107.75{\pm}3.96$에서 $80.30{\pm}4.34$로, 암컷에서 $99.56{\pm}3.22$에서 $81.67{\pm}3.72$로 원시생식세포수가 감소되었다. 이상의 연구 결과는 감마선 조사가 수용체 배자내의 원시생식세포를 감소시킬 수 있고, 이를 형질 전환 기술에 접목시켜서 생식선 카이메라 효율을 높일 수 있는 가능성을 보여 주고 있다.

$^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT (Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT)

  • 이무석;임영현;김재환;최규오
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.68-80
    • /
    • 2012
  • 감쇠 보정법과 산란 보정법은 정량적인 PET검사를 하기 위한 필수적인 방법이다. PET/CT에서는 PET에서 사용하는 소멸방사선과 CT의 X선이 같은 전리 방사선이기 때문에 측정에 의한 CT의 Hounsfield Units를 감쇠 계수로 전환해서 감쇠보정, 산란보정이 가능하다. 그러나 PET/MR에서 MR는 강한 자기장을 걸어 수소밀도와 조직의 이완률차이로 되돌아오는 변화로 신호를 획득하기 때문에 CT처럼 전환하는 것은 불가능하다. Ingenuity TF PET/MR장비는 soft tissue, lung, air로 3구역을 segment하여 MR 감쇠지도를 얻는다. 이에 신호획득원리가 완전히 상이한 PET/MR과 PET/CT에 대한 정량적 평가를 하고자 한다. Phantom study로 uniform cylinder phantom에 증류수 9293 ml와 $^{18}F$-FDG 199.8 MBq를 넣고 magnetic stirrer를 이용하여 균일하게 교반한 후 60 min부터 15분 간격으로 Ingenuity TF PET/MR, Gemini TF 64, Biograph Truepoint 40를 이용하여 각각 single-bed로 2 min씩으로 영상을 얻었다. phantom의 중심부분 10개의 slice에 대한 동일한 관심영역을 그려 SUVs를 측정하고 평균, 표준편차를 구하였다. 그리고 임상적용을 위한 평가로 $^{18}F$-FDG 섭취가 정상인 환자를 대상으로 90 sec/bed씩 Ingenuity TF PET/MR을 시행한 후 Gemini TF 64 PET/CT 검사를 실시하였다. 각각의 data에서 lung, liver, spleen, bone 위치에 동일한 관심영역을 그려 SUVs 최대값과 평균값을 측정하고, %Difference를 구하였다. 또한, PET 장비들 사이에서의 일치도를 평가하기 위해 Bland-Altman plot 분석을 하였다. Phantom study에서 3가지 장비에서 측정한 SUVs 최대값과 평균값은 Biograph Truepoint 40, Gemini TF 64, Ingenuity TF PET/MR 순으로 높은 것을 확인할 수 있었다. patients study에서는 MR과 CT로 감쇠 보정한 PET장비의 SUVs 최대값과 평균값이 서로 유의미한 차이가 없었다.(p<0.05) Lung에서 left middle lobe과 transverse bone을 제외하고는 MR로 감쇠 보정한 PET의 SUVs가 대체로 낮았다. Bland Altman Plot으로 분석한 결과 대부분의 항목에서 95% 신뢰구간의 일치한계선내에서 측정되었다. PET/CT에서는 time of flight 기능을 가진 PET이 SUVs가 낮게 측정되었다. PET/MR과 PET/CT에서 알아본 SUVs차이는 MR을 이용한 분할 감쇠 보정방법이 CT를 사용한 측정 감쇠보정방법보다 SUVs가 낮게 측정되었다. 이러한 다른 감쇠 보정법에 의한 SUVs의 차이는 임상적으로는 용인할 수준에 있었지만, 향후 PET/MR와 PET/CT의 정량적인 값을 비교 분석할 때 PET 장비들간의 특성은 고려할 필요가 있다.

  • PDF

돼지에서 초저체온 순환정지 하의 역행성 뇌관류시 뇌대사, 혈류역학 지표, 뇌조직 소견 및 혈청 내 neuron-specific enolase의 변화 (The Changes of Cerebral Metabolic and Hemodynamic Parameters, Brain Histology, and Serum Levels of Neuron-Specific Enolase During Retrograde Cerebral Perfusion Under Pofound Hypothermic total Circulatory Arrest in Pigs)

  • 김경환;안혁
    • Journal of Chest Surgery
    • /
    • 제33권6호
    • /
    • pp.445-468
    • /
    • 2000
  • Background: Retrograde cerebral perfusion(RCP) is currently used for brain protection during aorta surgery, however, for the safety of it, various data published so far are insufficient. We performed RCP using pig and investiaged various parameters of cerebral metabolism and brain injury after RCP under deep hypothermia. Material and Method: We used two experimental groups: in group I(7 pigs, 20 kg), we performed RCP for 120 minutes and in group II (5 pigs, 20 kg), we did it for 90 minutes. Nasopharyngeal temperature, jugular venous oxygen saturation, electroencephalogram were continuously monitored, and we checked the parameters of cerebral metabolism, histological changes and serum levels of neuron-specific enolose(NSE) and lactic dehydrogenase(LDH). Central venous pressure during RCP was mainained in the range of 25 to 30 mmHg. Result: Perfusion flow rates(ml/min) during RCP were 130$\pm$57.7(30 minutes), 108.6$\pm$55.2(60 minutes), 107.1$\pm$58.8(90 minutes), 98.6$\pm$58.7(120 minutes) in group I and 72$\pm$11.0(30 minutes), 72$\pm$11.0(60 minutes), 74$\pm$11.4(90 minutes) in group II. The ratios of drain flow to perfusion flow were 0.18(30 minutes), 0.19(60 minutes), 0.17(90 minutes), 0.16(120 minutes) in group I and 0.21, 0.20, 0.17 in group II. Oxygen consumptions(ml/min) during RCP were 1.80$\pm$1.37(30 minutes), 1.72$\pm$1.23(60 minutes), 1.38$\pm$0.82(90 minutes), 1.18$\pm$0.67(120 minutes) in group I and 1.56$\pm$0.28(30 minutes), 1.25$\pm$0.28(60 minutes), 1.13$\pm$0.26(90 minutes). We could observe an decreasing tendency of oxygen consumption after 90 minutes of RCP in group I. Cerebrovascular resistance(dynes.sec.cm-5) during RCP in group I incrased from 71370.9$\pm$369145.5 to 83920.9$\pm$49949.0 after the time frame of 90 minutes(p<0.05). Lactate(mg/min) appeared after 30 minutes of RCP and the levels were 0.15$\pm$0.07(30 minutes), 0.18$\pm$0.10(60 minutes), 0.19$\pm$0.19(90 minutes), 0.18$\pm$0.10(120 minutes) in group I and 0.13$\pm$0.09(30 minutes), 0.19$\pm$0.03(60 minutes), 0.29$\pm$0.11(90 minutes) in group II. Glucose utilization, exudation of carbon dioxide, differences of cerebral tissue acidosis between perfusion blood and drain blood were maintained constantly during RCP. Oxygen saturation levels(%) in drain blood during RCP were 22.9$\pm$4.4(30 minutes), 19.2$\pm$4.5(60 minutes), 17.7$\pm$2.8(90 minutes), 14.9$\pm$2.8(120 minutes) in group I and 21.3$\pm$8.6(30 minutes), 20.8$\pm$17.6(60 minutes), 21.1$\pm$12.1(90 minutes) in group II. There were no significant changes in cerebral metabolic parameters between two groups. Differences in serum levels of NSE and LDH between perfusion blood and drain blood during RCP showed no statistical significance. Serum levels of NSE and LDH after resuming of cardipulmonary bypass decreased to the level before RCP. Brain water contents were 0.73$\pm$0.03 in group I and 0.69$\pm$0.06 in group II and were higher than those of the controls(p<0.05). The light microscopic findings of cerebral neocortex, basal ganglia, hippocampus(CA1 region) and cerebellum showed no evidence of cerebral injury in two groups and there were no different electron microscopy in both groups(neocortex, basal ganglia and hippocampus), but they were thought to be reversible findings. Conclusion: Although we did not proceed this study after survival of pigs, we could perform the RCP successfully for 120 minutes with minimal cerebral metabolism and no evidence of irreversible brain damage. The results of NSE and LDH during and after RCP should be reevaluated with survival data.

  • PDF

체외순환 시 정상 산소분압과 고 산소분압의 염증반응 및 심근손상에 관한 비교연구 (Comparison of Inflammatory Response and Myocardial injury Between Normoxic and Hyperoxic Condition during Cardiopulmonary Bypass)

  • 김기봉;최석철;최국렬;정석목;최강주;김양원;김병훈;이양행;조광현
    • Journal of Chest Surgery
    • /
    • 제34권7호
    • /
    • pp.524-533
    • /
    • 2001
  • 배경: 체외순환 시 동맥혈액의 고 산소분압 유지는 오랫동안 안전한 기법으로 인식되어 임상에 이용하여 왔으나 고 산소분압은 정상 산소분압 보다 상대적으로 더 많은 독성 산소성분을 생성시켜 산화성 장기손상 및 재관류 손상의 원인이 된다. 저자들은 체외순환 시 동맥혈액을 고 산소분압 혹은 정상 산소분압 상태로 순환시켰을 때의 염증반응과 심근손상에 관해 비교검토하고, 정상 산소분압 체외순환의 임상적 유용성을 조사하기 위해 본 연구를 시행하게 되었다. 대상 및 방법: 성인 심장병 환자 30명을 고산소분압군(PaO2 400mmHg, 고산소군, n=15)과 정상산소분압군(Pa $O_{2}$ 120 mmHg, 정상산소군, n=15)으로 나눈 뒤 다음과 같은 변수들을 측정하여 두 그룹간에 비교하였다. 체외순환 전후의 관상정맥동 혈액을 채취하여 myeloperoxidase (MPO), malondialdehyde(MDA), troponin-T(TnT), adenosine monophosphate(AMP)를 분석하였고, 동맥혈액 내 총 백혈구 수 및 호중구 수를 측정하였다. 혼합 정맥혈액의 lactate 농도, 심장지수, 폐혈관저항도 체외순환 전, 중, 후 시기별로 함께 측정하여 두 그룹간에 비교하였다 결과: 체외순환 후 정상산소군이 고산소군에 비해 더 낮은 MDA농도 (4.79$\pm$0.7 vs 5.86$\pm$0.65 $\mu$mo1/L, p=0.04)와 보다 높은 AMP농도 (1.23$\pm$0.07 vs 1.00$\pm$0.04 nmol/L, p=0.05)를 보였으나 TnT농도 (0.50$\pm$0.08 vs 0.60$\pm$0.08 ng/mL, p>0.05)는 유의한 차가 없었다. 체외순환 후 MPO농도(5.38$\pm$1.01 vs 8.73$\pm$0.90 ng/mL, p=0.02)와 총 백혈구 수(10,484$\pm$836 vs 13,572$\pm$1,1671/㎥, p=0.04)는 정상산소군이 고산소군 보다 낮았다. 체외순환 후 lactate농도 (27.90$\pm$3.41 vs 31.49$\pm$4.87 mg/dL, p=0.55)와 심장지수(2.99$\pm$0.21 vs 2.75$\pm$0.18 L/$m^2$/min, p=0.39)는 양 군 간에 차이가 없었으나 폐혈관 저항(90.37$\pm$16.36 vs 118.12$\pm$12.21 dyne/sec/$cm^{5}$, p=0.04)은 정상산소군이 더 낮았다. 결론: 정상 산소분압 체외순환은 고 산소분압 체외순환에 비해 심근손상과 염증반응을 적게 유발하여 체외순환 후 심장 및 폐기능의 손상정도를 감소시킬 것으로 생각되며 이러한 결과는 정상 산소분압 체외순환이 심장수술에 유용하게 적용될 수 있음을 시사하고 있다.

  • PDF

기관배기 밸브용 강 ( SCr4-21-4N , SUH3-21-4N ) 의 마찰압접과 열처리에 관한 실험적 연구 (An Experimental Study on Friction Welding and Heat Treatment of Engine Exhaust Valve Steels ( SCr4-21-4 N , SUH3-21-4-N)

  • 오세규
    • 수산해양기술연구
    • /
    • 제14권2호
    • /
    • pp.79-87
    • /
    • 1978
  • 기관밸브용접 SCr4-21-4N 및 SUH3-21-4N을 연구선정된 최적마찰압접조건 하에서 마찰압접을 하고 이때 생기는 압접부의 잔류응력 및 경도의 peak 등 압접결함의 제거 및 압접성능개선을 위한 열처리에 관하여 실험연구한 결과 다음과 같은 결론을 얻었다. (1) 배기 valve용강 SCr4-21-4N 및 SUH3-21-4N의 마찰압접을 위한 최적조건으로서 회전수 3,000rpm, 마찰가열압 p 하(1)=8 kg/mm 상(2), upset 압 p 하(2)=20 kg/mm 상(2), 압접가열시간 t 하(1)=3초, upset 시간 2.5초를 선정한 것이 매우 타당함이 실험적으로 입증되었다. (2) 이종재질 SUH3-SUH31, SCr4-SUH31, SCr4-SUH3, SUH3-CRK22, SCr4-21-4N 및 SUH3-21-4N의 마찰압접에 관한 저자의 종래 연구와 본연구 결과는 압접부의 압접 특성이 서로 매우 일치하였다. (3) SCr4-21-4N 및 SUH3-21-4N의 마찰압접부의 잔류응력 및 전도의 peak를 제거하기 위한 최적열처리조건은 $600^{\circ}C$$\times$30min.$\times$room air cooling의 normalizing임이 확인되었다. (4) 이때 열처리 후에는, 열처리전의 인장강도의 약 20%가 감소했으나, 파단 위치는 열영향부로부터 모재 SCr4 및 SUH3 측으로 이동하였다. (5) 상기 최적조건 하에서 마찰압접되고 열처리된 압접부의 현미경 조직검사 결과, 압접부가 매우 좁고 압접결함이 없으며, 치밀하고 조밀한 조직의 우수한 압접이었음이 확인되었다. (6) 상기 최적조건은, 기관 valve 생산을 위한 타이종재질의 마찰압접조건으로도 응용될 수 있을 것이다.

  • PDF

기선권현망의 연구 II - 파치망의 유체저항과 그물꼴에 관하여 - (Study on the Anchovy Boat Seine - II - On The Hydrodynamic Resistance and Performance of Patti-net)

  • 이병기;서영태;한희수
    • 수산해양기술연구
    • /
    • 제14권2호
    • /
    • pp.63-68
    • /
    • 1978
  • 일본에서 멸치를 어획하는데 보편적으로 쓰이고 있는 파치망의 성능을 알기 위하여 1/20 크기의 모형어구를 제작하여 해상에서 예인하여 실험한 결과는 대략 다음과 같다.1. 어구의 전저항 $R_p$(kg)과 끝자루만의 저항 $R_b$(kg)은 예망속도 v(m/sec)가 $0.3\leqv\leq0.7$의 범위에 있을 때는 $R_p=69.6 V_{I.66}$ $R_h=37 v^2$라고 표현된다. 2. 그물꼴로서는 끝자루가 구김살없이 전개되고 수비부분이 재래식과 같이 봉소마모양이 되지 않으며, 날개끝에 여분의 망지가 없는 점을 장점이라고 볼수 있다. 그러나 그물목줄 길이는 날개끝의 도개깊이, 뜸줄쪽 그물목줄 및 발줄쪽 그물목줄의 길이 사이에 피타고라스정리가 성립되도록 조정할 필요가 있고, 또 날개 끝에 지나치게 무거운 추를 채우는 것도 바람직하지 않은 것 같다. 또 자루(문턱과 천장망사이)의 전개 깊이의 끝자루의 그것에 대한 비는 2:1정도이며, 어구 크기에 비하여 그 비가 그다지 크지 않은 것 같다. 또 예인속도가 빨라지면 문턱 밭줄이 날개끝 보다 들어 올려지는데, 이것을 시정하기 위해서는 끝자루 장력의 전달방식을 개선할 필요가 있다고 보아진다.은 韓國에 도입 된지 반세기가 넘었다. 그 동안 漁法이 引寄網에서 引廻網으로 발달하였고 漁具材料중 일부가 함성섬유로 대치되 있으며, 揚網機에 의한 날개그물의 양망등 상당한 발달을 하였다. 그러나, 漁具의 기본 형태는 引寄網시대의 원형에서 크게 벗어나지 않은 채 그저 확대되어 온 것에 지나지 않으며, 그물그물은 여전히 人力으로서 揚網되고 있어서 省力化를 위한 漁具, 漁船, 漁撈裝備의 개량이 요망되고 있다. 權現網漁業에 관한 硏究로서는 在來式漁具의 그물꼴에 관하여 李 梁 徐 孫(1971)이 1/10 크기의 模型漁具로써 연구한 것 이외는 없다. 다만 1972년 부터는 기선권 현망 수산업협동조합에서 일본식 파치망을 도입하여 실지 조업 시험을 실시한 바 있으며, 재래식의 반정도의 인력으로서 조업이 가능하므로 보편화되는가 했더니 어획성능이 좋지않아서 계속되지 않았다. 그러나 이 漁具는 일본에서는 보편적으로 쓰이고 있는것이므로 다른형의 漁具의 개발에 앞서이 漁具의 장단점을 규명하여 새로은 漁具의 개발이 참고가 되게 하고자 그 것의 모형실험을 실시하였다.의 개발이 참고가 되게 하고자 그 것의 모형실험을 실시하였다.

  • PDF

Prevalence of Chronic Obstructive Pulmonary Disease in Korea: The Result of Forth Korean National Health and Nutrition Examination Survey

  • Hwang, Yong-Il;Yoo, Kwang-Ha;Sheen, Seung-Soo;Park, Joo-Hun;Kim, Sang-Ha;Yoon, Ho-Il;Lim, Sung-Chul;Lee, Shin-Yup;Park, Jae-Yong;Park, Seoung-Ju;Seo, Ki-Hyun;Kim, Ki-Uk;Lee, Sang-Yeub;Park, In-Won;Lee, Sang-Do;Kim, Se-Kyu;Kim, Young-Kyoon;Lee, Sang-Min;Han, Sung-Koo;Kim, Yu-Na;Cho, Yu-Mi;Park, Hye-Jin;Oh, Kyung-Won;Kim, Young-Sam;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • 제71권5호
    • /
    • pp.328-334
    • /
    • 2011
  • Background: Chronic obstructive pulmonary disease (COPD) is a major cause of chronic morbidity and mortality throughout the world and is the only major disease that is continuing to increase in both prevalence and mortality. The second Korean National Health and Nutrition Survey revealed that the prevalence of COPD in Korean subjects aged ${\geq}45$ years was 17.2% in 2001. Further surveys on the prevalence of COPD were not available until 2007. Here, we report the prevalence of spirometrically detected COPD in Korea, using data from the fourth Korean National Health and Nutrition Survey (KNHANES IV) which was conducted in 2007~2009. Methods: Based on the Korean Statistical Office census that used nationwide stratified random sampling, 10,523 subjects aged ${\geq}40$ years underwent spirometry. Place of residence, levels of education, income, and smoking status, as well as other results from a COPD survey questionnaire were also assessed. Results: The prevalence of COPD (defined as forced expiratory volume in 1 sec/forced vital capacity <0.7 in subjects aged ${\geq}40$ years) was 12.9% (men, 18.7%; women, 7.5%). In total, 96.5% of patients with COPD had mild-to-moderate disease; only 2.5% had been diagnosed by physicians, and only 1.7% had been treated. The independent risk factors for COPD were smoking, advanced age, and male gender. Conclusion: The prevalence of COPD was 12.9% in the KNHANES IV data. Most patients with COPD were undiagnosed and untreated. Based on these results, a strategy for early COPD intervention is warranted in high risk subjects.

광중합 시 공기 중 산소의 차단이 치면열구전색제의 중합에 미치는 영향 (The effects of blocking the oxygen in the air during the polymerization of sealant)

  • 오유향;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제33권3호
    • /
    • pp.365-376
    • /
    • 2006
  • 할로겐, 플라즈마 그리고 2세대 고강도 LED 광중합기를 이용하여 치면열구전색제를 중합하는 과정에서 산소 차단 용액인 glycerin gel($DeOx^{(R)}$)의 도포, 질소가스와 탄산가스를 분사시켜 공기 중 산소와의 접촉을 차단시킨 후 산소억제층의 두께, 치면열구전색제의 중합률 그리고 표면경도를 측정, 평가하였다. 각각의 제작된 시편을 HPLC에서 역상크로마토그래피를 이용하여 미반응 모노머 TEGDMA의 용출양을 측정하여 중합률을 평가하였고, Vickers hardness tester를 이용하여 표면미세경도를 측정, 광학현미경을 이용하여 산소억제층의 두께를 측정하여 다음과 같은 결과를 얻었다. 1. 질소 및 탄산가스를 분사하면서 중합한 군, $DeOx^{(R)}$를 도포한 후 중합한 군 모두 공기 중에서 중합한 군보다. TEGDMA 용출량이 감소되었다(p<0.05). 2. 할로겐 광으로 20초간 중합한 경우 $DeOx^{(R)}$를 도포한 군과 질소 및 탄산가스를 분사한 군의 TEGDMA 용출량은 유사하였지만(p>0.05), 40초로 중합한 경우 탄산가스 분사군이 질소가스 분사군보다 TEGDMA 용출량이 적었다(p<0.05). 3. 플라즈마 광으로 10초간 중합한 경우 $DeOx^{(R)}$를 도포한 군의 TEGDMA 용출량이 가장 적었고(p<0.05), 탄산가스 분사군이 질소가스 분사군보다 용출량이 적었다(p<0.05). 4. LED 광원에서는 탄산가스 분사군이 질소가스 분사군보다 TEGDMA의 용출량이 적었다(p>0.05). 5. 세 광원 공히 공기 중에서 중합한 군보다 산소를 차단한 상태에서 중합한 군에서 미세경도가 크게 나타났다(p<0.05). 6. $DeOx^{(R)}$로 처리했을 때 플라즈마 광 10초와 LED광 20초 중합군이 할로겐 광 40초 중합군보다 미세경도 값이 높았고, 질소가스와 탄산가스 분사하에서 플라즈마 광으로 10초간 중합한 경우와 LED 광으로 20초간 중합 한 경우가 할로겐 광으로 40초간 중합한 경우 보다 높은 미세경도 값을 보였다(p<0.05). 7. 세 광원 모두 공기 중에서 중합한 군에 비해 질소 및 탄산가스 분사를 분사하면서 중합한 군 $DeOx^{(R)}$를 도포한 후 중합한 군이 산소억제층의 두께가 평균 49%의 감소되었으며(p<0.05), 이들 산소를 차단한 군 간의 유의차는 없었다.

  • PDF