• Title/Summary/Keyword: Seasonal energy

Search Result 418, Processing Time 0.026 seconds

Regional Distribution of Duration of Sunshine and Percentage of Sunshine by Jordan Type Sunshine Recorder and Bimetal Type Sunshine Recorder (Jordan 일조계(日照計)와 Bimetal 일조계(日照計)로 관측(觀測)된 일조시간(日照時間) 및 일조율(日照率)의 지역분포(地域分布) 비교(比較) 분석(分析))

  • Lee, Jeong-Taek;Yun, Seong-Ho;Park, Moo-Eon;Kim, Byung-Chan
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.1
    • /
    • pp.39-46
    • /
    • 1994
  • Two types of sunshine recorders, Jordan and bimetal, were used for measuring the duration of sunshine and percentage of sunshine in Weather Forecast Offices(WFO) and Weather Observation Stations(WOS) in Korea, respectively.These two gauges showed different values in each element observation. To evaluate the solar energy resources by duration and percentage of sunshine, relevant parameter should be adapted to use the two kinds of data for zoning of agricultural climatic area and comparison of regional solar energy distributions. In this respect, the correlation and distribution pattern were found by analyzing data from the two types of sunshine recorders. The results were as follows. The monthly duration of sunshine by the Jordan type was $50{\sim}60$ hours lower than the bimetal type and its value in May was the highest in a year. The percentage of sunshine by the Jordan type was $5{\sim}10%$ lower than the bimetal type. The seasonal difference of sunshine hour data by two types of sunshine recorder became small in winter but large in summer. Standard deviation of monthly duration of sunshine of WFO and WOS was $11{\sim}32$ and $17{\sim}25$ hours and percentage of sunshine was $3{\sim}11$ and $4{\sim}9$ % respectively. The range of deviation in WOS data was smaller than WFO. The highest distribution of duration and percentage of sunshine was in the Southern Coastal Area, whereas the lowest in the Central North Western Area.

  • PDF

Spaciotemporal Distributions of PM10 Concentration and Their Correlation with Local Temperature Changes : a Case Study of Busan Metropolitan City (PM10 농도의 시공간적 분포 특징과 국지적 기온 변화 간의 상관관계: 부산광역시 사례 분석)

  • Park, Sunyurp
    • Journal of the Korean association of regional geographers
    • /
    • v.23 no.1
    • /
    • pp.151-167
    • /
    • 2017
  • The main objective of this study was to investigate the climatic impact of $PM_{10}$ concentration on the temperature change pattern in Busan Metropolitan City(BMC), Korea during 2001~2015. Mean $PM_{10}$ concentration of BMC has gradually declined over the past 15 years. While the highest $PM_{10}$ concentration was observed in spring followed by winter, summer, and fall on average, the seasonal variations of $PM_{10}$ concentration differed from place to place within the city. Frequency analysis showed that the most frequently observed $PM_{10}$ concentration ranged from $20{\mu}g/m^3$ to $60{\mu}g/m^3$, which accounted for 64.6% of all daily observations. Overall, the west-high and east-low pattern of $PM_{10}$ concentration was relatively strong during the winter when the effect of yellow-dust events on the air quality was weak. Comparative analyses between $PM_{10}$ concentration and monthly temperature slope derived from generalized temperature curves indicated that the decreasing trend of $PM_{10}$ concentration was associated with increases of annual temperature range, and $PM_{10}$ concentration had a negative relationship with the temperature slope of warming months. Overall, $PM_{10}$ concentration had a weak correlation with the annual mean temperature, but it had a significant, positive correlation with the winter season, which had a dominant influence on the annual mean temperature. In terms of energy budget, it has been known that the change in $PM_{10}$ concentration contributes to the warming or cooling effect by affecting the radiative forcing due to the reflection and absorption of radiant energy. The correlation between $PM_{10}$ concentration and temperature changes in the study area was not seasonally and spatially consistent, and its significance was statistically limited partly due to the number of observations and the lack of potential socioeconomic factors relevant to urban air quality.

  • PDF

The Long-Term Variations of Water Quality in Masan Bay, South Sea of Korea (남해 마산만 수질의 장기 변동 특성)

  • Kwon, Jung-No;Lim, Jae-Hyun;Shim, Jeonghee;Lee, Jangho;Choi, Tae-Jun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.3
    • /
    • pp.212-223
    • /
    • 2014
  • For the better understanding of long-term and seasonal variations of water quality in Masan Bay, South Sea of Korea, we analyzed the archive data monitored at three stations of the bay during the last 13 years (2000-2012). The average concentrations of the chemical oxygen demand (COD), the dissolved inorganic nitrogen (DIN) and the dissolved inorganic phosphorus (DIP) during the monitoring period are $2.70{\pm}0.09{\mu}/L$, $19.66{\pm}1.84{\mu}m$ and $1.39{\pm}0.13{\mu}m$ in surface water, respectively, and $2.22{\pm}0.07{\mu}/L$, $18.53{\pm}1.36{\mu}m$ and $1.47{\pm}0.12{\mu}m$ in bottom water, respectively. The trophic state of the surface water was the eutrophic level in Masan Bay during the four seasons. The DIN concentrations of both surface and bottom waters increased from August to November and showed the highest average in November. However, The DIN decreased from February to May and showed the lowest average in May. The concentrations of the DIP and the dissolved silicate (DSi) in bottom waters had the highest averages in August because of the high water temperature and oxygen deficient condition. The results of correlation analysis and factor analysis showed that the main factors of surface waters were inflow of nutrients from terrestrial areas and internal production, and the main factors of bottom waters were the variations of the dissolved oxygen (DO), the DIP, and the DSi. The DIN and DIP average concentrations (2007~2012) had decreased in range of 68.1%~76.0% and 66.2~76.6%, respectively from 2007 in which the "Regulation of Total Emission" was established in Masan Bay. Therefore, it could have had positive effects on water quality improvement to take the "Regulation of Total Emission" and other actions such as reducing water pollutions in Masan Bay from 2007.

Surface Exchange of Energy and Carbon Dioxide between the Atmosphere and a Farmland in Haenam, Korea (한국 해남 농경지와 대기간의 에너지와 이산화탄소의 지표 교환)

  • Hee Choon Lee;Jinkyu Hong;Chun-Ho Cho;Byoung-Cheol Choi;Sung-Nam Oh;Joon Kim
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.61-69
    • /
    • 2003
  • Surface energy and $CO_2$ fluxes have been measured over a farmland in Haenam, Korea since July 2002. Eddy covariance technique, which is the only direct flux measurement method, was employed to quantitatively understand the interaction between the farmland ecosystem and the atmospheric boundary layer. Maintenance of eddy covariance system was the main concern during the early stage of measurement to minimize gaps and uncertainties in the dataset. Half-hourly averaged $CO_2$ concentration showed distinct diurnal and seasonal variations, which were closely related to changes in net ecosystem exchange (NEE) of $CO_2$. Daytime maximum $CO_2$ uptake was about -1.0 mg $CO_2$ m$^{-2}$ s$^{-1}$ in August whereas nighttime $CO_2$ release was up to 0.3 mg $CO_2$ m$^{-2}$ s$^{-1}$ during the summer. Both daytime $CO_2$ uptake and nighttime release decreased gradually with season. During the winter season, NEE was from near zero to 0.05 mg $CO_2$ m$^{-2}$ s$^{-1}$ . FK site was a moderate sink of atmospheric $CO_2$ until September with daily NEE of 22 g $CO_2$ m$^{-2}$ d$^{-1}$ . In October, it became a weak source of $CO_2$ with an emission rate of 2 g $CO_2$ m$^{-2}$ d$^{-1}$ . Long-term flux measurements will continue at FK site to further investigate inter-annual variability in NEE. to better understand these exchange mechanism and in-depth analysis, process-level field experiments and intensive short-term intercomparisons are also expected to be followed.

Spatial Characteristic in Food Sources for Benthic Invertebrates in an Estuary Tidal flat: Carbon and Nitrogen Stable Isotope Analyses (안정동위원소 비를 이용한 하구 갯벌에 있어서 저서 무척추 동물의 유기물 기원의 공간적 특성)

  • Shin, Woo-Seok;Lee, Yong-Doo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.1
    • /
    • pp.53-59
    • /
    • 2010
  • The spatial variability in the food chain structure of an estuarine environment(Nanakita estuarine, Japan) was investigated using stable carbon and nitrogen isotope. Potential organic matter sources(TP:Terrstrial Plant, MPOM:Marine particulate organic matter, BMA:Benthic microalgae, EPOM:Estuarine particulate organic matter), sedimentary organic matter and benthic invertebrates(Nuttallia olivacea and Nereidae) were sampled at four locations with different tidal flat types(e.g. sanddy, sanddy-muddy and muddy). The main objective of the present study was to determine food sources of Nuttallia olivacea and Nereidae along with small-scale spatial variability within the community of benthic invertebrates. TP(${\delta}^{13}C=-26.6{\pm}0.76$ and ${\delta}^{15}N=2.7{\pm}0.31$) and EPOM(${\delta}^{13}C=-25.5{\pm}0.13$ and ${\delta}^{15}N=5.2{\pm}0.46$) were isotopically distinct from BMA(${\delta}^{13}C=-16.3$ and ${\delta}^{15}N=6.2$) and MPOM(${\delta}^{13}C=-19.6{\pm}0.08$ and ${\delta}^{15}N=8.9{\pm}1.70$). ${\delta}^{13}C$ values of sedimentary organic matter showed a distinct gradient in the range of -27.4 to -22.8‰ with a declining trend from the upstream to the downstream stations. The stable carbon and nitrogen isotope values of benthic invertebrates in the study site was -22.8 to -18.4‰ for ${\delta}^{16}C$ and 8.1 to 11.9‰ or ${\delta}^{15}N$, respectively. Mixing model(Isosource) calculations based on stable isotope measurements showed that benthic invertebrates of Nuttallia olivacea and Nereidae were found to be dominated by MPOM and BMA in stations. Whereas, TP and EPOM showed little influence to benthic invertebrates. The current result suggests that the different contribution for benthic invertebrates should be affected by both seasonal variation and physical factor among stations.

Recipe Standardization and Nutrient Analysis of 'Dong-rae Pajeon' (Local Food in Busan) (부산 향토음식 동래파전의 조리표준화 및 영양분석)

  • Kim, Sang-Ae;Shin, Eun-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.36 no.11
    • /
    • pp.1472-1481
    • /
    • 2007
  • The purposes of the study were to find refined taste of ancestor through historical research about traditional cooking method and ingredient for the purpose of enriching today#s dietary life and to hand down a particular style of regional dish and excellence of nutritional aspect by providing a standard recipe and nutrition analysis data on #Dong-rae Pajeon#. To collect data about traditional ingredients and cooking method, researcher interviewed seven local natives who have kept a traditional food costumes, visited four restaurants, and reviewed ten cookbooks. The interviewees recalled and demonstrated the cooking procedure. The standard recipe of #Dong-rae Pajeon# was created after three experimental cookings, based on the recipes of the natives, restaurants, and cookbooks. According to the natives# statements, #Dong-rae Pajeon# was a special dish that was offered to the king at #Samzi-nal# (March 3rd of the lunar calendar). It was also a seasonal (before cherry blooming time) and memorial service dish of the province#s high society. The main ingredients were small green onion, dropwort, beef, seafood (large clam, mussel, clam meat, oyster, shrimp, fresh water conch), waxy rice powder, non-wax rice powder, and sesame oil which were abundant in Busan and Kijang region. Energy per 100 g of #Dong-rae Pajeon# was 148 kcal. Protein, lipid, fiber, Ca, and Fe contents were 8.8 g, 2.0 g, 8.6 g, 57.7 mg, and 1.8 mg respectively. Contents of cystine, lysine, leucine, valine, isoleucine which are essential amino acids were high in #Dong-rae Pajeon#. Fatty acids contents are oleic acid (20.5%), linoleic acid (20.1%) and linolenic acid (10.4%) while P/M/S ratio was 0.73/0.67/1.

The Present State and Problems of Hotel Buffet Styled Restaurant -II. A Survey of Ecology in Food and Nutrition of Some Urban Females Dining in Hotel Buffet Styled Restaurant- (호텔 뷔페음식(飮食)에 관(關)한 실태조사(實態調査) -제(弟) 2보(報). 여성(女性)들의 뷔페식당(食堂)에서의 끽식행동(喫食行動)에 관(關)한 연구(硏究)-)

  • Choi, Kyung-Suk;Mo, Su-Mi
    • Journal of the Korean Society of Food Culture
    • /
    • v.6 no.2
    • /
    • pp.185-197
    • /
    • 1991
  • An eating behavior research was done with 50 females at a buffet styled restaurant during their lunch time. Of the respondents, 52.0% were professional and 54.0% were graduate school graduates. Of the respondents, 58.0% of the company were friends and 24.0% were relatives. The average time period of eating was $93.0{\pm}23.4$ minutes. The average frequency of taking food was $4.0{\pm}1.1$ and the average frequency of taking food after satiety was $1.4{\pm}0.8$. It is significant that lower frequency of food consumption was directly proportional to the age groups of respondents. The average selected food items were $30.4{\pm}7.1$ out of 175 and the average weight of the consumed food was $995.0{\pm}240.9$ g. The older age group chose a similar number of food items, but the amount of each food item was considerably less than younger. So the younger the age group was, the more they ate. The average food items at one time was $7.1{\pm}2.2$ and the average food weight time was $233.7{\pm}69.7$ g. The percentage of respondents who evaluated themselves as 'ate too much' was 70.0% and those who evaluate themselves 'ate properly' was 14.0%. Most of them were satisfied with the buffet service. The average of number of food items consumed by respondents before cooking was $50.5{\pm}8.9$. The consumption of calories and nutrients was compared with the Korean Daily Recommended Dietary Allowances. The consumed calories were 60.9% of RDAs, protein 104.4%, calcium 77.1%, iron 129.8%, vitamin A 66.5%, thiamin 96.0%, riboflavin 95.7%, niacin126.6% and ascorbic acid 112.3%. This data exceeded 1/3 of the Korean Daily RDAs tremendously and tells us extreme overeating. The energy ratio of carbohydrate: fat: protein was 51.6: 29.9: 18.5. Caloric consumption of animal food was 27.9% and the consumption rate of the other nutrients from animal food was considerably high. But the consumption rate of vitamin A was 90.9% from vegetable groups. Accoding to this study, buffet service gives some advantages. It gives customers an good opportunity to vary their food intake, which enhances eating experiences and can cause an improvemont of food habits. But overeating is a problem. Therefore, we think it is necessary for those women who have influence over their family's food selection, to have nutrition education about a desirable order of eating a meal, food selection, and health problems due to overeating at buffet styled restaurant. There should be some improvement in the management of buffet service. For example, proper temperature, texture, and freshness of the food should be maintained. Prevention of mixed food smells should be considered as well. To lower the price it is desirable to reduce the number of similar items and to use seasonal food as much as possible. A buffet styled restaurant with less food items with cheaper prices is recommended. Various traditional food should be developed for the menu items. We expect buffet services to be sutable to maintain good health and to be popular to any eater.

  • PDF

Temporal and Spatial Distribution of Biomass and Cell Size of Bacteria and Protozoa in Lake Paldang and Kyungan Stream (팔당호와 경안천에서 박테리아와 원생생물의 생물량과 세포크기의 시 ${\cdot}$ 공간적 분포)

  • Son, Ju-Youn;Kong, Dong-Soo;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.3 s.117
    • /
    • pp.378-389
    • /
    • 2006
  • Seasonal changes of biomass and cell size of bacteria and protozoa, and factors affecting their distribution in Lake Paldang and Kyungan Stream were analyzed from April to December, 2005. Bacterial abundance at Paldang Dam and Kyungan Stream was similar, but it did not much increase during hot summer period. Protozoan carbon biomass was much greater at Kyungan Stream compared to Paldang Dam. HNAN generally accounted for the majority of total protozoan biomass, but ciliates made up the highest proportion in April and November at Paldang Dam and June at both sites. PNAN showed low biomass at both sites, but it was high during spring and fall season. Small-sized HNAN ($3{\sim}7\;{\mu}m$) numerically predominated the protozoan community at both sites. Average cell size of HNAN was bigger at Kyungan Stream where nutrients concentration was much higher than Paldang Dam. Average cell size of ciliates varied seasonally; it was relatively small during the summer. HNAN biomass significantly correlated with Chl-a concentration and ciliates biomass at Paldang Dam, indicating that HNAN increase might link to the ciliates increase. At Kyungan Stream, HNAN biomass showed a significant relationship with PNAN biomass, and Chl-a concentration was closely related with both of HNAN and PNAN biomass. Ciliate biomass showed significant relationship with nutrient (TN, TP) and particulate matter (SS) only at Kyungan Stream. At both sites, protozoan biomass was significantly correlated with bacterial biomass, and ciliates were additionally related flagellates. High biomass of microbial components and the close relationships among them suggest that the energy transfer through the microbial loop may important in the plankton food web of Lake Paldang ecosystem.

Detection and Measurement of Nuclear Medicine Workers' Internal Radioactive Contamination (핵의학과 종사자의 방사성동위원소 체내오염 측정)

  • Jeong, Gyu-Hwan;Kim, Yong-Jae;Jang, Jeong-Chan;Lee, Jai-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.123-131
    • /
    • 2009
  • Purpose: We tested a sample of nuclear medicine workers at Korean healthcare institutions for internal contamination with radioactive isotopes, measuring concentrations and evaluating doses of individual exposure. Materials and Methods: The detection and measurement was performed on urine samples collected from 25 nuclear medicine workers at three large hospitals located in Seoul. Urine samples were collected once a week, 100~200 mL samples were gathered up to 6~10 times weekly. A high-purity germanium detector was used to measure gamma radiations in urine samples for the presence of radioactive isotopes. Based on the detection results, we estimated the amounts of intake and committed effective doses using IMBA software. In cases where committed effective doses could not be adequately evaluated with IMBA software, we estimated individual committed effective doses for radionuclides with a very short half life such as $^{99m}Tc$ and $^{123}I$, using the methods recommended by International Atomic Energy Agency. Results: Radionuclides detected through the analysis of urine samples included $^{99m}Tc$, $^{123}I$, $^{131}I$ and $^{201}Tl$, as well as $^{18}F$, a nuclide used in Positron Emission Tomography examinations. The committed effective doses, calculated based on the radionuclide concentrations in urine samples, ranged from 0 to 5 mSv, but were, in the majority of cases, less than 1 mSv. The committed effective dose exceeded 1 mSv in three of the samples, and all three were workers directly handling radioactive sources. No nurses were found to have a committed effective dose in excess of 1 mSv. Conclusions: To improve the accuracy of results, it may be necessary to conduct a long-term study, performed over a time span wide enough to allow the clear determination of the influence of seasonal factors. A larger sample should also help increase the reliability of results. However, as most Korean nuclear medicine workers are currently not necessary to monitored routinely for internal contamination with radionuclides. Notwithstanding, a continuous effort is recommended to reduce any unnecessary exposure to radioactive substances, even if in inconsequential amounts, by regularly surveying workplace environments and frequently monitoring atmospheric concentrations of radionuclides.

  • PDF

Analysis of the Utilization Characteristics of Electrical Power and Equipments on the Farms (농촌의 전력및 전기기기의 이용특성분석)

  • 박승우;류한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.4
    • /
    • pp.3943-3955
    • /
    • 1975
  • The purposes of this study are to evaluate the utilization characteristics of electrical power consumption, to grasp the present trends in the use of electrical equipments, to estimate the demand factor and load factor being held, and to evaluate the efficiency of electical uses for the recently electrified farms cultivating paddy rice. For the purposes, 109 sample farms located in eleven villiages electrified in six different years from 1968 to 1973, were chosen at random and investigated on 35 items concerning to electrical uses and wiring systems. The survey was carried out in 1975, in the vinicity of Suweon city. The results are summarized as follows: i) The average annual power consumption on sample farms is considered to be low, being 242.9 Kwh. in 1974, and varied according to the different electrified year and size of cultivated land, respectively. It has significant positive correlation to the area of farm, too. ii) Between the number of year of electrical uses and the power consumption, there is very significant positive correlation, which could be expressed as Y=43.041+16.108 X, where X represents the number of years of electrical uses. The annual increment of power consumption is much greater at the beginning of the electrification than that at the later years, its average being approximately 20 percent. However, it is recommended that any estimation of long-term increments should be carefully investigated. iii) The monthly power consumption varies considerably throughout a year, in which the heaviest farm load occurs in November. Observing the seasonal variation of consumption, the winter-time is the heaviest season while the summer is the lowest. The result implies house lighting is chief contribution to the present electrical consumption on the farms. Comparing the variation of monthly consumption ratios between the sample farms and industries, the electrical uses on the farms are independant of the industrial uses, and further, the agricultural uses are of inverse pattern to the farms from the results that there is negative correlationship between them, iv) The number of electrical equipments used on the farms are occupied chiefly by lighting sources. Next to the lighting sources, household appliances of small quantity and some motors are used. The mean electrical quantity is about 1, 127.4 watt, which corresponds to about 37.6 per cent to the contracted quantity. The composition of quantity is chiefly occupied by the electrical motor of about 1.5 hp., single-phased. The number of the annual utilization hours of each equipment is tabulated in Table IV-5. In contradiction to the high utilization of lighting sources and small household appliances, the motor is poorly used for approximately 22 hours in a year. v) More than 55 per cent of farms want to purchase new electrical equipments such as small household appliances and electrical motors in their number. The impulse of purchasing such items is stimulated by the contacts to the mass media and their knowledge on such equipments. Consequently, the increase of electrical uses could be prompted by such trials as education and demonstration. vi) The demand and load factors on the farms vary considerably according to the greater variation of the power consumption, daily or monthly. The daily demand factor is 22.4 per cent and load factor 18.6 per cent, while the annual demand factor is 1.3 per cent and load factor 70 per cent approximately. Therefore, the low efficiency of construction cost requires re-evaluation of the present contracted quantity of 3 Kw. or increase of electrical uses. vii) The electrical energy on the farms devoted chiefly to lighten the farm residences does not contribute to the farm incomes. Consequently, the cost of electrical consumption presses considerably upon the farm economy. Therefore, there is great need to build up the electrical uses on the farms through the development of new works and techinques to utilize any electrical equipments on the production of farm products. Further more, such the development should be related to increase the actual income of the farm consumers.

  • PDF