• Title/Summary/Keyword: Seasonal energy

Search Result 418, Processing Time 0.027 seconds

CO2 and Energy Exchange in a Rice Paddy for the Growing Season of 2002 in Hari, Korea (한국 하리 논에서의 2002년 생장기간의 CO2와 에너지의 교환)

  • Byung-Kwan Moon;Jinkyu Hong;Byoung-Ryol Lee;Jin I. Yun;Eun Woo Park;Joon Kim
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.51-60
    • /
    • 2003
  • Rice, which occupies about 60% of the farmland in Korea, is a staple crop in Asia. It not only absorbs $CO_2$ from the atmosphere, but also emits carbon in a form of CH$_4$. It has a potential role in the global budget of greenhouse gases because of its relative contributions of carbon absorption and emission associated with changing hydrologic cycle. To better understand its current and future role, seasonal variations of energy and $CO_2$ exchange in this critical ecosystem need to be quantified. The purpose of this study was to measure, document and understand the exchange of energy and $CO_2$ in a typical rice paddy in Korea throughout the whole growing season. Since late April of 2002, we have conducted measurements of energy and $CO_2$ exchange in a rural rice paddy at Hari site, one of the Korea regional network of tower flux measurement (KoFlux). After the quality control and gap-filling, the observed fluxes were analyzed in the context of micrometeorology and biophysics. $CO_2$ and energy exchanges varied significantly with land cover changes (e.g., plant growth stages), in addition to changes in weather and climate conditions. This study, reporting first direct measurement of energy and $CO_2$ exchange over a rice paddy in Korea, would serve as a useful database as one of the reference sites in AsiaFlux and FLUXNET.

Sensitivity analysis of the FAO Penman-Monteith reference evapotranspiration model (FAO Penman-Monteith 기준증발산식 민감도 분석)

  • Rim, Chang-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.4
    • /
    • pp.285-299
    • /
    • 2023
  • Estimating the evapotranspiration is very important factor for effective water resources management, and FAO Penman-Monteith (FAO P-M) model has been applied for reference evapotranspiration estimation by many researchers. However, because various input data are required for the application of FAO P-M model, understanding the effect of each input data on FAO P-M model is necessary. Therefore, in this study, for 56 study stations located in South Korea, the effects of 8 meteorological factors (maximum and minimum temperature, wind speed, relative humidity, solar radiation, vapor pressure deficit, net radiation, ground heat flux), energy and aerodynamic terms of FAO P-M model, and elevation on FAO P-M reference evapotranspiration (RET) estimation were analyzed. The relative sensitivity analysis was performed to determine how 10% increment of each specific independent variable affects a reference evapotranspiration under given set of condition that other independent variables are unchanged. Furthermore, to select the 5 representative stations and perform the monthly relative sensitivity analysis for those stations, 56 study stations were classified into 5 clusters using cluster analysis. The study results showed that net radiation was turned out to be the most sensitive factor in 8 meteorological factors for 56 study stations. The next most sensitive factor was relative humidity, solar radiation, maximum temperature, vapor pressure deficit and wind speed, followed by minimum temperature in order. Ground heat flux was the least sensitive factor. In case of ground surface condition, elevation showed very low positive relative sensitivity. Relativity sensitivities of energy and aerodynamic terms of FAO P-M model were 0.707 for energy term and 0.293 for aerodynamic term respectively, indicating that energy term was more contributable than aerodynamic term for reference evapotranspiration. The monthly relative sensitivities of meteorological factors showed the seasonal effects, and also the relative sensitivity of elevation showed different pattern each other among study stations. Therefore, for the application of FAO P-M model, the seasonal and regional sensitivity differences of each input variable should be considered.

Analysis of Operation Data Monitoring for LPG-Hydrogen Multi-Fueling Station (LPG-수소복합충전소 운영데이터 모니터링 분석)

  • Park, Songhyun;Kim, Donghwan;Ku, Yeonjin;Kim, Piljong;Huh, Yunsil
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.1-7
    • /
    • 2019
  • In response to the recent increase in demand for hydrogen stations, the Ministry of Trade and Industry has enacted and promulgated special notifications to enable the installation of hydrogen stations in the form of the combined complex in existing automotive fuel supply facilities such as LPG, CNG, and gas stations. Hydrogen multi energy filling stations haven't been operated yet in Korea till the establishment of special standards, so it is necessary create special standards by considering all Korean environmental characteristics such as four seasons and daily crossings. In this study, we collected and analyzed the charging data of Ulsan LPG-Hydrogen Multi Fueling Station installed for the first time in Korea. The data are hourly temperature and pressure data from compressors, storage vessels and dispensers. We used the data collected for a year, including the highest temperature and the lowest temperature in Ulsan to compare seasonal characteristics. As a result, it was found that the change of the outside temperature affects the initial temperature of the vehicle's container of the hydrogen car, which finally affects the charging time and the charging speed of the vehicle. There was no effect on vehicle containers because the limit temperature suggested by the Korean Hydrogen Station Standard(KGS FP217) and the US Filling Protocol(SAE J2601) was not exceeded.

Relationship Analysis of Reference Evapotranspiration and Heating Load for Water-Energy-Food Nexus in Greenhouse (물-에너지-식량 넥서스 분석을 위한 시설재배지의 기준작물증발산량과 난방 에너지 부하 관계 분석)

  • Kim, Kwihoon;Yoon, Pureun;Lee, Yoonhee;Lee, Sang-Hyun;Hur, Seung-Oh;Choi, Jin-Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.4
    • /
    • pp.23-32
    • /
    • 2019
  • Increasing crop production with the same amount of resources is essential for enhancing the economy in agriculture. The first prerequisite is to understand relationships between the resources. The concept of WEF (Water-Energy-Food) nexus analysis was first introduced in 2011, which helps to interpret inter-linkages among the resources and stakeholders. The objective of this study was to analyze energy-water nexus in greenhouse cultivation by estimating reference evapotranspiration and heating load. For the estimation, this study used the physical model to simulate the inside temperature of the agricultural greenhouse using heating, solar radiation, ventilated and transferred heat losses as input variables. For estimating reference evapotranspiration and heating load, Penman-Monteith equation and seasonal heating load equation with HDH (Heating Degree-Hour) was applied. For calibration and validation of simulated inside temperature, used were hourly data observed from 2011 to 2012 in multi-span greenhouse. Results of the simulation were evaluated using $R^2$, MAE and RMSE, which showed 0.75, 2.22, 3.08 for calibration and 0.71, 2.39, 3.35 for validation respectively. When minimum setting temperature was $12^{\circ}C$ from 2013 to 2017, mean values of evapotranspiration and heating load were 687 mm/year and 2,147 GJ/year. For $18^{\circ}C$, Mean values of evapotranspiration and heating load were 707 mm/year and 5,616 GJ/year. From the estimation, the relationship between water and heat energy was estimated as 1.0~2.6 GJ/ton. Though additional calibrations with different types of greenhouses are necessary, the results of this study imply that they are applicable when evaluating resource relationship in the greenhouse cultivation complex.

Seasonal Fluctuations of Marine Environment and Phytoplankton Community in the Southern Part of Yeosu, Southern Sea of Korea (여수 남부 협수로 해역의 해양환경과 식물플랑크톤 군집의 계절변동 특성)

  • Noh, Il-Hyeon;Yoon, Yang-Ho;Park, Jong-Sick;Kang, In-Seok;An, Yeong-Kyu;Kim, Seung-Hyun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.3
    • /
    • pp.151-164
    • /
    • 2010
  • Field observations on the seasonal variations of environmental factors and phytoplankton community were carried out four times at 30 stations in the narrow strait between Yeosu and Dolsan Island of the Korean South Sea from September 2005 to May 2006. The ranges of water temperature, salinity and extinction coefficient in the surface waters were 5.6~26.3, 25.36~33.92 psu and 0.13~2.13, respectively. The water temperature measured higher at Gamak Bay in summer and spring. It measured higher at Yeosuhae Bay in autumn and winter. Salinity showed uniformity of distributions in almost all areas, except for an area near a sewage disposal outlet. Extinction coefficient indicated that the turbidity of Gamak Bay and the area near the sewage disposal outlet were higher than that of the Yeosuhae Bay. In the phytoplankton community were identified a total of 99 species belonging to 51 genera. The species composition showed itself to be various in summer and autumn, but poor in winter and spring with a high ratio of centric diatoms all the year round. Seasonal succession of dominant species were Skeletonema costatum and Chaetoceros curvisetus in summer, Eucampia zodiacus in autumn and winter, and Chaetoceros affinis and Thalassionema nitzschioides inspring. Standing crops of phytoplankton and Chlorophyll $\alpha$ concentration were greatly higher at Gamak Bay in summer with ranges of $0.2{\times}10^4\;cells\;L^{-1}$ to $296{\times}10^4\;L^{-1}$, and $1.94\;L^{-1}$ to $22.12\;L^{-1}$, respectively. From the results of principal component analysis (PCA), the northern part of Dolsan Island was divided into two or three regions from the characteristics of marine environment and phytoplankton community.

Empirical Modeling of Fouling Rate of Milk Pasteurization Process : A case study

  • Budiati, Titik;Wahyono, Nanang Dwi;Hefni, Muh.
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.11-17
    • /
    • 2015
  • Fouling in heat exchanger becomes a major problem of dairy industry and it increases the production cost. These are lost productivity, additional energy, additional equipment, chemical, manpower, and environmental impact. Fouling also introduces the risk of food safety due to the improper heating temperature which allow the survival of pathogenic bacteria in milk, introducing biofilm formation of pathogenic bacteria in equipments and spreading the pathogenic bacteria to milk. The aim of this study is to determine the fouling rate during pasteurization process in heat exchanger of pasteurized milk produced by Village Cooperative Society (KUD) "X" in Malang, East Java Indonesia by using empirical modeling. The fouling rate is found as $0.3945^{\circ}C/h$ with the heating process time ranged from 0 to 2 hours and temperature difference (hot water inlet temperature and milk outlet temperature) ranged from 0.654 to $1.636^{\circ}C$. The fouling rate depends on type and characteristics of heat exchangers, time and temperature of process, milk type, age of milk, seasonal variations, the presence of microorganism and more. This results will be used to plan Cleaning In Place (CIP) and to design the control system of pasteurization process in order to maintain the milk outlet temperature as standard of pasteurization.

Performance Analysis on CHP Plant using Back Pressure Turbine according to Return Temperature Variation (배압터빈을 사용하는 열병합발전소의 열 회수 온도에 따른 성능특성 분석)

  • Im, Shin Young;Lee, Jong Jun;Jeon, Young-Shin;Kim, Hyung-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.26-33
    • /
    • 2016
  • Combined heat and power (CHP) system is one of the power generation system which can generate both electricity and heat. Generally, mid-size and big-size CHP plant in Korea generate electricity from gas turbine and steam turbine, then supply heat from exhaust gas. Actually, CHP can supply heat using district heater which is located at low pressure turbine exit or inlet. When the district heater locates after low pressure turbine, which called back pressure type turbine, there need neither condenser nor mode change operating control logic. When the district heater locates in front of low pressure turbine or uses low pressure turbine extraction steam flow, which calls condensing type turbine, which kind of turbine requires condenser. In this case, mode change operation methods are used for generating maximum electricity or maximum heat according to demanding the seasonal electricity and heat.

Database Construction to Compute Representative Model of Load Power Factor in Bulk Power System (대규모 전력계통의 부하역률 대표모델 산정을 위한 데이터베이스 구축)

  • Cho, Jong-Man;Lee, Hyo-Sang;Lee, Jung-He;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.83-89
    • /
    • 2004
  • The importance of the Load Power Factor(LPF) management is newly noticed from the voltage management and operation of the power system due to the rapidly increasing reactive power consumed. Therefore, this paper proposes the regional, seasonal and hourly Representative Model of Load Power Factor(RMLPF) considering load characteristics of all 154/22.9[kV] substations. The RMLPF is used to present a precision improvement of power system analysis and security. Computation of representative model of load utilizes the average flow method based on moving average method. The Energy Management System(EMS) data are used as the source to assess the load power factor.

High-resolution Numerical Wind Map for Korean (한반도 고해상도 수치바람지도 구축)

  • Lee, Hwa-Woon;Kim, Dong-Hyeuk;Lee, Soon-Hwan;Kim, Min-Jung;Kim, Hyun-Goo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.463-466
    • /
    • 2009
  • The numerical simulation optimized by Four Dimensional Data Assimilation (FDDA) with Quick Scatterometer (QuikSCAT) data is carried out to evaluate wind resource characteristics at various heights in the southeastern area of the Korean Peninsula, where wind farms are planned to be built on on- and off-shore as well as comparable diurnal wind variations are characterized at the surface. The temporal and spatial distributions of modeled wind speeds showed good agreement with the observations based on the temporal variation analysis. Model results indicate that the higher model is performed in resolution, the more precise results is at turbine hub height. Occasionally, wind speed variations for each numerical resolution has a different regional and seasonal variations. In the coast area, hub height wind speed of 9km-resolution is simillar to that of 3km-resolution. On the other hand, hub height wind speed of 3km-resolution is simillar to that of 1km-resolution in the Jiri mountainous area.

  • PDF

Geochemistry of Acid Mine Water and Stream Sediment around the Donghae Coal Mine (동해탄광 주변 산성광산폐수와 하상퇴적물의 지구화학)

  • Oh, Dae Gyun;Kim, Jung Youp;Chon, Hyo Taek
    • Economic and Environmental Geology
    • /
    • v.28 no.3
    • /
    • pp.213-220
    • /
    • 1995
  • Geochemistry of stream water and sediment collected in the vicinity of the Donghae coal mine in the Samchuk coalfied were investigated in order to evaluate the environmental impacts of acid mine drainage. The pH of stream water ranges from 2.85(at 2 km away from the mine) to 7.92(at uncontaminated tributary). The main cation and anion species in the upper stream are $Ca^{2+}$ and $SO_{4}{^2-}$, respectively. The level of pH and the amount of $HCO^{3-}$ in stream water increase to the downstream and where uncontaminated small tributaries are joining, and in the area covered with limestone. From the results of thermodynamic calculation, the main forms of iron in stream water are estimated as $Fe^{2+}$ and $FeSO_{4}{^0}$, and most of them could be precipitated as FeO(OH) with increase of pH. The white precipitates in stream sediments particularly found around the coal mine are proved to be $Al(OH)_3$ by XRD and XRF analysis. As a result of investigation for seasonal variation of AMD, the level of pH decreased and conductivity increased in dry season.

  • PDF