• 제목/요약/키워드: Sea water heat exchanger

검색결과 50건 처리시간 0.024초

Corrosion Property Evaluation of Copper Alloy Tubes against Sea Water

  • Pang, Beilli;Ong, Sang-Kil;Lee, Hong-Ro
    • 한국표면공학회지
    • /
    • 제42권6호
    • /
    • pp.280-286
    • /
    • 2009
  • In this study, the corrosion property of copper alloy tubes in seawater has been investigated. Three copper alloys of nominal composition Cu-20Zn-2Al(Al-Brass), Cu-30Ni(CN70/30) and Cu-10Ni(CN90/10) were considered. The samples were immersed in 3%NaCl flowing solution at $90^{\circ}C$ for 30, 50 and 80 days. Corrosion rate of copper alloy tubes in 3%NaCl flowing solution was investigated by weight-loss measurements and electrochemical test. The CN70/30 showed lowest corrosion rate among three copper alloy tubes. Because of passive films formation, corrosion rates of three types of copper tubes were decrease with time. Surface characteristics of copper alloy tubes were analyzed by optical micrograph(OM), scanning electronic microscopy (SEM), energy dispersive X-ray analysis(EDAX) and X-ray diffraction patterns(XRD). CN70/30 showed partly pitting problem on the surface owing to high Fe content, even though having high resistant against corrosion. Cracks appeared on the surface of CN90/10 and CN70/30 after more than 50 days immersion, which could be derived from high nickel contents.

VMD 모듈의 열성능 특성 연구 (A Study on the Thermal Characteristics of Vacuum Membrane Distillation Module)

  • 주홍진;양용우;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.23-31
    • /
    • 2014
  • This study was accomplished to get the foundation design data of VMD(Vacuum Membrane Distillation) system for Solar Thermal VMD plant. VMD experiment was designed to evaluate thermal performance of VMD using PVDF(polyvinylidene fluoride) hollow fiber hydrophobic membranes. The total membrane surface area in a VMD module is $5.3m^2$. Experimental equipments to evaluate VMD system consists of various parts such as VMD module, heat exchanger, heater, storage tank, pump, flow meter, micro filter. The experimental conditions to evaluate VMD module were salt concentration, temperature, flow rate of feed sea water. Salt concentration of feed water were used by aqueous NaCl solutions of 25g/l, 35g/l and 45g/l concentration. As a result, increase in permeate flux of VMD module is due to the increasing feed water temperature and feed water flow rate. Also, decrease in permeate flux of VMD module is due to increasing salinity of feed water. VMD module required about 590 kWh/day of heating energy to produce $1m^3/day$ of fresh water.

해수용 열교환기 적용을 위한 열분사 코팅의 부식 및 열전도 특성에 관한 실험적 연구 (Experimental Study on Corrosion and Thermal Conductivity Characteristics of Thermal Spray Coating for Sea Water Heat Exchanger)

  • 조맹익;허철;권영철;권정태
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6098-6105
    • /
    • 2013
  • 본 연구에서는 해수용 열교환기 적용을 위한 열분사코팅의 종류에 따른 부식특성 및 열전도 성능을 조사하기 위해 실험이 수행되었다. 코팅은 아연과 알루미늄을 열분사코팅한 뒤 실리콘 및 에폭시 수지를 추가 도포한 시편을 선정하였다. 코팅의 부식특성 변화를 관찰하기 위하여 사이클릭 선도변화 측정 및 SEM촬영을 이용하였다. 시편의 열전도 성능을 측정하기 위해서 레이저 확산법을 이용하여 열전도도를 비교하였으며 추가도포를 실리콘으로 한 경우 3 ~ 4% 에폭시로 한 경우 70 ~ 75%의 열전도도 하락이 발생하였다.

선박용 흡수식 냉동기의 냉매적용 냉각 시스템 성능 분석 (Performance analysis of a cooling system with refrigerant in a marine absorption refrigerator)

  • 윤상국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.282-287
    • /
    • 2016
  • 최근 조선사들은 선박이 운항되는 연안 환경의 개선과 보호를 위하여 $CO_2$를 절감할 수 있는 친환경 선박과 함께 선박 운항 중 소비하는 에너지의 절감을 위한 고효율화 선박 개발의 노력도 활발하게 수행하고 있다. 본 연구에서는 전기로 구동되는 선박의 증기압축식 냉동기 대신에 선박 엔진 자켓수의 폐열을 이용하여 냉방을 할 수 있는 흡수식 냉동기의 적용 가능성과 냉각시스템에 냉매를 적용하는 시스템의 성능을 분석하였다. 연구결과, 해수와 열교환하여 액화될 수 있는 냉매들 중 R236fa가 가장 적합한 냉매로 분석되었으며, 이를 적용한 흡수식 냉동기의 COP는 0.798로 육상의 냉각탑을 이용한 수랭식보다 15% 그리고 해수 열교환기식 수랭식보다 5% 향상되었다. 냉동능력 1RT를 얻기 위한 LiBr 흡수용액 순환량은 0.013 kg/s로 수랭식 보다 25% 이상 감소하며, 냉각 매체 순환량도 수랭식의 15.7%에 불과한 매우 효과적인 냉동기가 되었다. 해수온도가 $18^{\circ}C$ 이하로 낮으면 발생하게 되는 LiBr의 결정화는 재생기에서 배출되는 엔진 자켓수의 온도를 이용하여 해수 온도를 상승시킴으로써 방지할 수 있다.

선박용 냉각수의 고.액분리에 관한 연구 (A Study on the Solid-Liquid Separation of Cooling Water in Ships)

  • 최민선;김준효;조대환;한원희;김부기
    • 동력기계공학회지
    • /
    • 제7권4호
    • /
    • pp.25-30
    • /
    • 2003
  • Hydrocyclone has been widely used for the solid-Liquid separation in many industrial sites because of its comparatively preferable applications that can be applied to wide-range panicle sizes. If seawater with impurities flows through pumps or heat exchanger, it might cause an decrease in efficiency of cooling system. In this paper, we have suggested solid methods of separating impurities from seawater in the cooling system by using a Hydrocyclone. The effects of design factors as solid concentration, cyclone inlet pressure, flow rate and diameter of underflow on the seperating performance of the Hydrocyclone were investigated. The results from the study are summarized as follows: 1) In proportion to the increase of solid concentration, the efficiency of solid-liquid separation is improved. 2) According as the cyclone inlet pressure increases the efficiency of separation is improved. Conclusively, this research suggested that the Hydrocyclone will be used as a pre-treatment system of cooling water in ships, and eventually prevent unexpected accidents in engine systems.

  • PDF

LNG선박용 열교환기 세관의 SCC에 미치는 응력의 영향 (The Effect of Stress on SCC of Heat Exchanger Tube for LNG Vessel)

  • 정해규;임우조
    • 한국가스학회지
    • /
    • 제7권2호
    • /
    • pp.22-32
    • /
    • 2003
  • Al-황동은 기계적 특성 및 열전도성이 우수하고 해수 중에서 표면 보호피막을 형성하므로 부식저항성이 높아 해수를 냉각수로 사용하는 선박용 열교환기의 세관재로 널리 사용되고 있다 Al-황동 세관은 실제 사용 환경에서 굽힘 등에 의한 소성변형된 상태로 사용되는 경우가 많다. 이와 같은 소성변형에 의한 Al-황동 세관의 균열 파손사례는 선박의 오일탱크 내의 가열코일, 각종 열교환기의 세관 등에서 흔히 찾아 볼 수 있다. 또한 세관의 확관에 의한 밀봉 방법에 따라 세관의 변형에 의한 잔류응력 및 어패류 혼입에 의한 해수 유입부의 국부적인 유속증가 등에 기인하여 Al-황동 세관의 균열 및 침식 등의 파손사례가 보고되고있다. 본 연구에서는 $3.5\%$ NaCl. + $0.1\%\;NH_4OH$ 수용액을 시험편 표면에 5 m/s로 액분사하의 가속실험에서 Al-황동 세관의 응력부식균열 거동에 미치는 응력의 영향에 대하여 고찰하였다.

  • PDF

LNG 냉열을 이용한 냉장·냉동 창고 모사에 관한 연구 (A Study of Simulation on the Refrigerated Warehouse System Based on the Cold Energy of Lng Using the Pro-Ii Simulator)

  • 한단비;김윤지;염규인;신재린;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제28권4호
    • /
    • pp.401-406
    • /
    • 2017
  • When Liquified Natural Gas (LNG) is vaporized into NG for industrial and household usage, tremendous cold energy was transferred from LNG to seawater during phase-changing process. This heat exchanger loop is not only a waste of huge cold energy, but will cause thermal pollution to the coastal fishery area also when cold water was re-injected into the sea. In this study, an innovation design has been performed to reclaim the cold energy for -35 to $62^{\circ}C$ refrigerated warehouse. Conventionally, this was done by installing mechanical refrigeration systems, necessitating tremendous electrical power to drive temperature. A closed loop LNG heat exchangers in series was designed to replace the mechanical or vapor-compression refrigeration cycle by process simulator. The process simulation software of PRO II with provision has been used to simulate this process for various conditions, what to effect on cold energy and used energy for re-liquefaction and evaporation process. In addition, through analysis the effect of the change of LNG supply pressure on sensible and latent heat, optimum operational conditions was suggested for LNG cold energy warehouse.

해수 냉각시스템 효율 향상을 위한 하이드로사이클론의 적용가능성 (Applicability of the Hydrocyclone for Efficiency Improvements to Sea-water Cooling Systems)

  • 김부기;한원희;조대환;최민선
    • 해양환경안전학회지
    • /
    • 제11권2호
    • /
    • pp.109-115
    • /
    • 2005
  • 하이드로사이클론은 다양한 산업 방면의 고$\cdot$액 분리를 위해 널리 사용되어왔다. 왜냐하면 하이드로사이클론의 적당한 응용으로 폭넓은 범위의 입자에 적용이 가능하기 때문이다. 불순물을 함유한 해수가 펌프나 열교환기로 흘러가면 그것은 해수 냉각시스템의 효율을 저하시키는 원인이 된다. 본 연구에서는 하이드로사이클론을 이용한 해수 냉각시스템에서 불순물을 분리하는 몇가지 방법을 제시했다. 설계의 영향을 미치는 인자로서 고체농도, 사이클론 입구압력, 하부배출구의 직경과 유량에 따른 하이드로사이클론의 분리효율에 대해 연구를 하였다. 이 연구의 결과는 다음과 같다. 1) 고형물질의 농도가 감소할수록 고$\cdot$액 분리의 효율이 증가하였다. 2) 사이클론 입구압력이 증가함에 따라 분리효율이 증가하였다. 결과적으로 이 연구에서는 하이드로사이클론을 기계류 냉각시스템의 전처리장치로 사용한다면 엔진시스템에서 예상치 못했던 사고를 방지할 수 있을 것이다.

  • PDF

해수 냉각시스템 효율 향상을 위한 하이드로사이클론의 적용가능성 (Applicability of the Hydrocyclone for Efficiency Improvements to Sea-water Cooling Systems)

  • 김부기;한원희;조대환;최민선
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2004년도 추계학술발표회
    • /
    • pp.109-115
    • /
    • 2004
  • 하이드로사이클론은 다양한 산업 방면의 고$\cdot$액 분리를 위해 널리 사용되어왔다 왜냐하면 하이드로사이클론의 적당한 응용으로 폭넓은 범위의 입자에 적용이 가능하기 때문이다. 불순물을 함유한 해수가 펌프나 열교환기로 흘러가면 그것은 해수 냉각시스템의 효율을 저하시키는 원인이 된다. 본 연구에서는 하이드로사이클론을 이용한 해수 냉각시스템에서 불순물을 분리하는 몇가지 방법을 제시했다. 설계의 영향을 미치는 인자로서 고체농도, 사이클론 입구압력, 하부배출구의 직경과 유량에 따른 하이드로사이클론의 분리효율에 대해 연구를 하였다 이 연구의 결과는 다음과 같다. 1) 고형물질의 농도가 감소할수록 고$\cdot$액 분리의 효율이 증가하였다. 2)사이클론 입구압력이 증가함에 따라 분리효율이 증가하였다. 결과적으로 이 연구에서는 하이드로사이클론을 기계류 냉각시스템의 전처리장치로 사용한다면 엔진시스템에서 예상치 못했던 사고를 방지할 수 있을 것이다.

  • PDF

폐쇄형 해양온도차발전 사이클에 관한 연구 (A Study of Closed OTEC Power Plants)

  • 신상호;정동수;김종보;서태범;천원기;오정무
    • 태양에너지
    • /
    • 제17권4호
    • /
    • pp.23-33
    • /
    • 1997
  • 본 연구에서는 Rankine 사이클을 이용한 해양 온도차 발전 시스템을 컴퓨터로 모사했고 작동유체를 변화시켜 가면서 그 성능을 비교하였다. 증발기와 응축기는 UA(총괄열전달계수$\times$전열면적)와 LMTD(대수평균온도차) 방법으로 모사하였으며 터빈과 펌프는 등엔트로피 효율로 모사하였다. 작동유체로는 R22, R290, R1270, R134a, R125, R143a, R32, R410A 그리고 암모니아 등을 사용하였다. 모사 결과 OTEC 발전 시스템의 효율은 작동유체에 상관없이 거의 일정한 것으로 드러났다. 한편 증발기 출구에서의 과열도와 응축기 출구에서의 과냉도는 시스템의 성능에 거의 영향을 미치지 않는 것으로 나타났지만 터빈의 효율과 열교환기의 크기는 시스템 성능에 큰 영향을 미치는 것으로 나타났다. 마지막으로 따뜻한 표층수와 차가운 심해수 사이의 온도차가 $20^{\circ}C$이상일 때 실제로 전기를 생산할 수 있다는 사실을 확인했다.

  • PDF