• Title/Summary/Keyword: Sea water cooling

Search Result 139, Processing Time 0.031 seconds

포항지역 지열수에 대한 지화학적 고찰

  • 김통권;이진수;이승구;송윤호
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.101-103
    • /
    • 2004
  • To investigate the evidence for the influence of sea water on Pohang geothermal groundwater, the chemical data for geothermal groundwaters from which are pumped during 48 hours and other hot groundwaters, another groundwater on the well for the purpose of agriculture, were considered. And to predict possible the secondary mineral which are easily to make the clogging, geochemical modeling was carried out using EQ3NR equilibrium solubility code. The results are that 1.4%~3.3%(bulk composition) of sea water were mixed with geothermal groundwater. From the well logging data, when the level of groundwater is drow down, the conductivity is increased in the geothermal groundwater, the existence of transition zone are recognized in the well. The predicted possible secondary minerals are Antigorite [Mg48Si24O85(OH)62], Chrysolite [Mg3Si2O5(OH)4] , Cristobalite, Dolomite, Talc, Tremolite. The recommended cooling temperature of best condition to minimize the production of secondary minerals is same as temperature of geothermal water pumped from the well.

  • PDF

A Study on Determining the Transmission Loss of Water-Borne Noise Silencer in a Sea-Connected Piping System (해수연결 배관계 소음감소기의 투과손실 측정에 관한 연구)

  • Park, Kyung-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.6
    • /
    • pp.286-292
    • /
    • 2007
  • The dominant source of noise in a sea-connected piping system is usually due to a seawater cooling pump which circulates seawater to operate onboard equipments normally, and so its water-borne noise with some tonal frequencies should be reduced using proper silencers. In order to obtain the transmission loss of water-borne noise silencers experimentally the present paper suggests a transfer function technique that acoustic wave in the piping system is decomposed into its incident and transmitted components when the reflection at the termination of the system exists. Good agreement in the interested frequency range with theory and the proposed technique shows the validity of the technique.

A Study on Simulation of an Water Cooling Intercooler for a Small Marine Diesel Engine (소형 선박용 디젤엔진의 수냉식 인터쿨러 해석 연구)

  • Yang, Young-Joon;Sim, Han-Sub
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.5
    • /
    • pp.43-49
    • /
    • 2014
  • This study was carried out to improve the design of an intercooler for a small marine diesel engine. Diesel engines for small marine ships have mainly been developed by changing the structure of the vehicle engine. Sea water was most commonly used in the intercooler of small marine diesel engines to cool the hot air compressed by the turbocharger. In this study, the intercooler is modeled and simulated using STAR-CCM+ in order to find optimal data for the design of an intercooler. In the results, the temperature differences between the data from a numerical analysis and experimental data were $0.38^{\circ}C$ in the hot air outlet and $3.63^{\circ}C$ in the cooling water outlet. Therefore, it was confirmed that both analysis and experimental results need to be considered when designing an intercooler. A closer degree of similarity in the two datasets can improve the confidence in the design of these intercoolers.

Performance Characteristic of Live Fishing Tank in Cooling Apparatus inshore Fishing Boat (연근해 어선용 활어조 냉각장치의 성능특성)

  • 한인근;이호생;김재돌;김흥윤;윤정민
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.1
    • /
    • pp.52-56
    • /
    • 2001
  • A fundamental study on the cooling apparatus inshore fishing boat and its operation characteristics in sea water cooling system were performed experimentally. The circumstance is giving the blow against fisherman with incoming-decreasing and the difficulty of crew's supply and demand and management. In addition, the depression of the external situation such as the plan of EEZ(Exclusive Economic Zone) proclaim is forcing them into improving their fishing condition. By this international and domestic surrounding, the development of a cooling apparatus inshore fishing boat is demanded sincerely. We investigated load characteristics as the pilot plant operation characteristics estimation which is based on the development of cooling system and optimum cooling apparatus inshore fishing boat. These results provide useful informations which are applicable to an actual design and show the possibility of application to other fields.

  • PDF

Inversion Phenomena of Temperature in the Southern Sea of Korea (한국 남해의 수온역전현상)

  • KIM Hee-Joon;YUG Sang-Sup
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.2
    • /
    • pp.111-116
    • /
    • 1983
  • Temperature inversions are investigated by using the oceanographic data (1965-1979) obtained in the Southern Sea of Korea. The temperature inversions in winter occur about six times more frequently than those in sumner. In the west region of the Southern Sea, the inversions are found at any depth in winter. In the east region of the Southern Sea, however, they usually appear in surface layer in winter. Such inversion phenomena in winter can be explained by surface cooling effects associated with a net heat loss at the sea surface and a southward advection of surface cold water due to north-westerly monsoon. In summer the inversion layers are usually formed below the thermocline in the west region of the Southern Sea, and in surface layer in the east region. The former results from the mixing between the Tsushima Warm Current and the Yellow Sea Bottom Cold Water, and the latter is generated by an offshore flow of cold water near coast due to southwesterly wind.

  • PDF

Development of Multi Effect Distillation for Solar Thermal Seawater Desalination System (태양열 해수담수화 시스템을 위한 다중효용 담수기 개발)

  • Joo, Hong-Jin;Hwang, In-Seon;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • This study was accomplished to evaluate the performance of Multi Effect Distillation(MED) for solar thermal desalination system. It was designed Multi effect distillation with $3m^3$/day capacity and Shell&Tube type heat exchanger. Also, The effective heat transfer of Shell&Tube heat exchanger was used Cu(90%)-Ni(10%) corrugated tube. The parameters relating to the performance of Multi Effect Distillation are known as hot water flow rate. The experimental conditions for each parameters were $18^{\circ}C$ for sea water inlet temperature, $6m^3$/hour sea water inlet volume flow rate, $75^{\circ}C$ for hot water inlet temperature, 2.4, 3.6, and $4.8\;m^3$/hour for hot water inlet volume flow rate, respectively. The results are as follows, Development for Multi effect distillation was required about 40kW heat and 35kW cooling source to produce $3m^3$/day of fresh water. Based on the results of this study, It makes possible to secure economics of desalination system with solar energy which is basically needed development of high efficiency fresh water generator.

Development of Numerical Model for Unsteady Flow Analysis jin Discharge Culvert of Thermal Power Plant: I. Model Setup (열발전소 배수암거 부정류해석 수치모형의 개발 : I. 모형의 정립)

  • Yun, Seong-Beom;Lee, Gi-Hyeok
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.6
    • /
    • pp.761-768
    • /
    • 1997
  • A numerical model is developed to analyze the incompressible unsteady flow induced by the pump trip-out in the cooling water discharge culvert of thermal power plants. The numerical models has various features to deal concureently with the overall behavior of complicated unsteady flow due to the presence of cooling water internal system, seal well, air chamber, culvert, manholes, open channel and sea water. A leap-frog finite difference scheme is employed to solve governing equations, and the model is tested for a simple case of two tanks connected with a pipe. A fixed free surface boundary condition used earlier at the downstream end of culvert for large water body is investigated.

  • PDF

Performance Evaluation of Multi Effect Distillation for Solar Thermal Desalination (태양열 해수담수화를 위한 증발식 다중효용 담수기 성능평가)

  • Joo, Hong-Jin;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.74-79
    • /
    • 2011
  • This study was accomplished to evaluate the performance of Multi Effect Distillation(MED) for solar thermal desalination system. It was designed Multi effect distillation with $3m^3/day$ capacity and Shell&Tube type heat exchanger. Also, The effective heat transfer of Shell&Tube heat exchanger was used Cu(90%)-Ni(10%) corrugated tube. The parameters relating to the performance of Multi Effect Distillation are known as hot water flow rate. The experimental conditions for each parameters were $18^{\circ}C$ for sea water inlet temperature, $6m^3/hour$ sea water inlet volume flow rate, $75^{\circ}C$ for hot water inlet temperature, 2.4, 3.6, and $4.8m^3/hour$ for hot water inlet volume flow rate, respectively. The results are as follows, Development for Multi effect distillation was required about 40kW heat and 35kW cooling source to produce $3m^3/day$ of fresh water. And, Performance ratio of Development Multi effect distillation was about 2.0191.

  • PDF

Revaluation of Tsunami Risk at the Site of Ulchin Nuclear Power Plant (울진 원자력발전소 부지에 대한 지진해일 위험도 재평가)

  • 이해균;이대수
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • In the past, safety assessment on the site of Ulchin Nuclear Power Plants against tsunamis was carried out with probable maximum earthquake magnitude and related tsunamigenic fault parameters. Recently, however, based on the seismic gap theory, some seismologists warned about earthquakes of larger magnitudes than had been expected. In this study, we revaluated tsunami risk with a finite difference model based on linear and nonlinear shallow water equations. Firstly, we simulated the\`83 tsunami and compared the calculated water surface profile with the observed wave heights. Secondly, we evaluated the rise and drop of sea water level at the site of Ulchin Nuclear Power Plant with fault parameters of the past '83, '93 tsunamis and some dangerous faults. Finally, we showed that the cooling water intake facility of Ulchin Nuclear Power Plants would be safely operated in disastrous tsunamis.