• 제목/요약/키워드: Screw type

검색결과 547건 처리시간 0.028초

공기 유입시의 터보펌프 특성 (Air Influx Characteristics of Turbo Pumps)

  • 김유택;남청도;강호근;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.43-48
    • /
    • 2004
  • A screw-type centrifugal pump was manufactured to carry solids primarily and its impeller has a wide flow passage. However, the effect of flow passage shape on delay of the choke due to entrained air has not been clarified yet. Moreover, because its impeller has a particular shape, only few studies have tried to clarify the pump performance and details of internal flow pattern of that pump. For that reason, we carried out the pump performance experiment under air-water two-phase flow condition with different impeller tip clearances, pump rotational speeds and void fractions by using a small screw-type centrifugal pump designed to acquire basic data. In a general centrifugal pump, it was reported that loss of pump head from single-phase flow to the choke due to air entrainment new the best efficiency point was large. However, the loss near the best efficient point in a screw-type centrifugal pump became less than that in a general centrifugal pump.

  • PDF

Clinical Outcomes of Halo-Vest Immobilization and Surgical Fusion of Odontoid Fractures

  • Kim, Seung-Kook;Shin, Jun-Jae;Kim, Tae-Hong;Shin, Hyung-Shik;Hwang, Yong-Soon;Park, Sang-Keun
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권1호
    • /
    • pp.17-22
    • /
    • 2011
  • Objective : In the present study, authors retrospectively reviewed the clinical outcomes of halo-vest immobilization (HVI) versus surgical fixation in patients with odontoid fracture after either non-surgical treatment (HVI) or with surgical fixation. Methods : From April 1997 to December 2008, we treated a total of 60 patients with upper cervical spine injuries. This study included 31 (51.7%) patients (22 men, 9 women; mean age, 39.3 years) with types II and III odontoid process fractures. The average follow-up was 25.1 months. We reviewed digital radiographs and analyzed images according to type of injury and treatment outcomes, following conservative treatment with HVI and surgical management with screw fixation. Results : There were a total of 31 cases of types II and III odontoid process fractures (21 odontoid type II fractures, 10 type III fractures). Fifteen patients underwent HVI (10 type II fractures, 5 type III fractures). Nine (60%) out of 15 patients who underwent HVI experienced successful healing of odontoid fractures. The mean period for bone healing was 20.2 weeks. Sixteen patients underwent surgery including anterior screw fixation (6 cases), posterior C1-2 screw fixation (8), and transarticular screw fixation (2) for healing the odontoid fractures (11 type II fractures, 5 type III fractures). Fifteen (93.8%) out of 16 patients who underwent surgery achieved healing of cervical fractures. The average bone healing time was 17.6 weeks. Conclusion : The overall healing rate was 60% after HVI and 93.8% with surgical management. Patients treated with surgery showed a higher fusion rate and shorter bony healing time than patients who received HVI. However, prospective studies are needed in the future to define better optimal treatment and cost-effective perspective for the treatment of odontoid fractures.

개선된 설측 고정 나사 시스템(T-screw system)을 이용한 임플란트 보철 수복 증례 (Clinical cases of implant-supported fixed dental prosthesis using modified lingual screw system (T-screw system))

  • 홍태영;김만용;윤준호
    • 대한치과보철학회지
    • /
    • 제54권4호
    • /
    • pp.423-430
    • /
    • 2016
  • 임플란트 보철물은 나사 유지형 보철물과 시멘트 유지형 보철물로 나눌 수 있다. 각 방법은 장점과 함께 임플란트를 유지 관리하는데 불리한 단점을 가지고 있다. 이러한 단점을 극복하기 위해 개선된 설측 고정 나사 시스템(T-screw system)이 개발되었다. T-screw system은 설측 방향의 나사를 이용하여 임플란트 보철물을 유지하는 방법으로, 보철물의 탈부착이 쉽고, 수동적 적합이 가능하며, 심미적이고 기능적인 교합면을 형성할 수 있다는 장점이 있다. 기존의 수평 나사를 이용한 보철은 기공 과정이 어려워 다수 유닛의 보철물의 경우 제작이 쉽지 않았고, 완전 도재를 이용한 보철물에서는 사용할 수 없다는 한계를 가지고 있었다. 본 증례에서 T-screw system을 이용하여 임플란트 보철물을 제작함으로써 유지 관리가 용이하고 심미적, 기능적으로 우수한 결과를 얻었다. 또한 다수 유닛의 임플란트 보철 및 완전 도재를 이용한 임플란트 보철에서 T-screw system을 이용하는 방법을 보고하고자 한다.

스크류 압축기의 연구개발 동향 (Research Trend in Screw Compressor Development)

  • 이대영;김영일;남임우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.151-158
    • /
    • 1998
  • The screw compressor is first invented by a Swedish engineer, Alf Lysholm in 1934. Since then, the development of the screw compressor idea for industrial applications has been continued by the Swedish research organization Svenska Rotor Maskiner, often identified by its initials SRM. The first industrial application of the machine was marketed as an air compressor in the 1950s. The screw compressor which is a positive displacement type compressor compresses gases by the rotation of a pair of mating rotors. The operation of this compressor is entirely rotary and dynamically in balance. Also there is no need for any valve mechanism and there exists less mechanical wear between the parts compared to the conventional reciprocating compressors. Due to these prominent features, the screw compressor has been rapidly spread into the air compressor market replacing the conventional reciprocating compressors and begun to be applied as a refrigerant compressor since the 1960s. In this work, the operation principle of the screw compressor is described in brief and the major design parameters affecting the compressor performance are classified. The international research trend in screw compressor development is introduced and the current situation in our country is described.

  • PDF

지반의 교란을 최소화 한 원위치시험법 개발 및 적용 : 스크류재하시험 (Low-Soil Disturbance In-Situ Test Method Development and Its Application : Screw Plate Loading Test)

  • 이용수;황웅기;최용규;김태형
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.977-986
    • /
    • 2009
  • Sampling disturbance can introduce considerable errors in the laboratory estimation of geotechnical properties of soils, and the results obtained from sophisticated sampling and careful laboratory testing are not matching with field behavior. Therefore, it is advantage to adopt in-situ testing techniques for the estimation of geotechnical parameters. Therefore, Screw plate loading test, one of new field test technologies, has been investigated in this study. This test can be utilized to find out important properties of soils such as load-displacement, elastic modulus, and shear strength. The screw plate loading test modified from the plate loading test is an experiment underneath ground by inserting a spiral type of auger screw. The structure and characteristics of the screw plate loading test device was examined in detail. In addition, The new screw plate loading test device was manufactured to refer the previous studies. The reliability of developing screw plate loading test was examined through the analysis of the laboratory test.

  • PDF

임플랜트 상부구조의 재료가 반복하중 후 나사풀림에 미치는 영향 (AN INFLUENCE OF ABUTMENT MATERIALS ON A SCREW-LOOSENING AFTER CYCLIC LOADING)

  • 이태식;한중석;양재호;이재봉;김성훈
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.240-249
    • /
    • 2007
  • Statement of problem: A phenomenon of screw-loosening in implant abutment is frequently occurred in a single and multiple implant restoration. Purpose: This study was performed to evaluate an effect of abutment material on screw-loosening before and after a cyclic loading. In a single-tooth implant, different materials of abutment, Type III Gold alloy and Zirconium composite$(ZrO_2/Al_2O_3)$ were used. Material and method: The Gold alloy(Type III) and Zirconium composite$(ZrO_2/Al_2O_3)$ were used to make a superstructure of implant, the one of types of UCLA, Each group was constituted of 5 sample with a 30-degree offset angulated loading platform. The external hexagonal fixture was rigidly hel d in a special holding zig to ensure solid fixation without rotation during the tightening and a cyclic loading. A Titanium-alloy screw was used to connect and controlled to be tighten in 20Ncm torque by a digital torque gauge. A 20 times of consecutive closing/opening cycle were performed to evaluate the immediate torque loss. In 5 sample of each material group, an initial opening torque was recorded during 3 closing/opening cycle, then 2Hz, 200N, 1,000,000 cyclic loadings were performed, then a opening torque was evaluated. Result & Conclusion: 1. In this limited study, titanium alloy screw tightened in 20Ncm, a cold-welding phenomen on was not observed during the 20 times of closing/opening cycle(p=0.11, p=0.18). 2. In titanium alloy abutment screw, repeated opening and closing of the screw caused to progressive decrease of opening torque(p=0.014). 3. The difference in preload of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant(p=0.78). 4. The difference in torque loss of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant after 2Hz,200N, 1,000,000 cyclic loading(p=0.92). 5. In titanium alloy abutment screw tightened by 20Ncm, the screw loosening was not significant on each group after 2Hz, 200Ncm, 1,000,000 cyclic loading(p=0.59).

교합형 동방향 이축압출기의 스크류 조합에 대한 고찰 (A Review on the Screw Configuration of Intermeshing Co-rotating Twin Screw Extruder)

  • 이시춘;김형수
    • Korean Chemical Engineering Research
    • /
    • 제59권3호
    • /
    • pp.305-315
    • /
    • 2021
  • 교합형 동방향이축압출기는 고분자재료의 컴파운딩에 주로 사용되는 기계이다. 이축압출기는 가공하는 재료와 생산제품에 적합한 스크류 조합을 설계하여 품질과 생산성이 양호한 컴파운딩공정을 구축할 수 있다. 스크류조합을 구성하는 스크류와 니딩 엘리먼트의 종류, 형상 및 사양에 대하여 정리하였고, 각각의 엘리먼트가 조합될 때 고분자 수지의 가공성에 미치는 영향에 대하여 알아보았다. 범용수지의 대량생산에 보편적으로 적용되는 스크류 조합의 원리를 설명하였고, 피딩, 용융혼련 및 미터링영역에 적합한 스크류조합의 방향과 사례를 나열하였다. 액상첨가제나 무기필러의 사이드피딩, 반응압출, 탈기공정, 밝은 색상과 투명도가 요구되는 제품의 생산 및 겉보기비중이 낮은 재료의 가공 등 각각의 경우에 맞는 스크류조합의 방향과 원리를 제시하였다.

단일 임플랜트 보철물의 Hex-lock 형태에 따른 3차원 유한요소법적 응력분석 (A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT PROSTHESES ACCORDING TO THE HEX-LOCK TYPE)

  • 황영필;계기성;조규종
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.385-402
    • /
    • 1996
  • The purpose of this study was to analyze how the stability of the implant prostheses and the loosening of the fastening screw was affected when the various types of Hex structure provided for the effect of anti-rotation of the single prostheses were given. Three dimensional finite element model was designed with which the implants with the external hex type of 0.75mm, 1.5mm and the implant with the internal hex type of 0.75mm, 1.5mm and the implant with the external hex type of $15^{\circ}$ tapered shape of 0.75mm were supposed to completely osseointegrate to the mandible. After fininshing the finite element model, the preload of 10N at the fastening screw was applied and then the vertical and $30^{\circ}$ lateral load of 200N was applied respectively at the cusp tips of the prostheses. The following results were obtained : 1. In case of displacement, the amount of displacement was increased at the internal hex type(model C, D) than at the external hex type(model A, B, E) when the vertical and lateral load was applied. 2. Less equivalent stress was represented at the model B with increased external hex height than at the model A when the vertical and lateral load was applied. 3. Much stress was represented at the model E with increased hex angle than at the model A in case of the stress happened to the implant body and the fastening screw when the vertical and lateral load was applied. 4. Much equivalent stress was represented at the model D with deepened internal hex height than at the model C when vertical and lateral load was applied. 5. The least stress was taken at the model B and the most stress was taken at the model D in case of the stress happened to the implant when the vertical and lateral load was applied. 6. The least stress was taken at the model C at the vertical load. And the least stress was taken at the model B at lateral load in case of the stress happened to the fastening screw. As a results of this study, the good lateral stability of prostheses and less stress of the component of implant was taken when the external hex height was increased, and the risk of neck fracture of implant and fastening screw was increased when the internal hex height was deepned because of long screw neck portion and thin implant neck portion.

  • PDF

종골의 관절 함몰 골절에서 6.5 mm 해면골 나사와 Steinmann 핀을 이용한 치료의 유용성 (Usefulness of Treatment with 6.5 mm Cancellous Screw and Steinmann Pin Fixation for Calcaneal Joint Depression Fracture)

  • 이기수;강찬;황득수;노창균;이기영
    • 대한족부족관절학회지
    • /
    • 제19권1호
    • /
    • pp.11-17
    • /
    • 2015
  • Purpose: To report the radiographic and clinical results of 6.5 mm cancellous full threaded buttress screw or Steinmann pin fixation to maintain a reduction of calcaneal posterior facet depression fracture. Materials and Methods: From June 2009 to June 2012, 50 consecutive cases with calcaneal joint depression fracture that underwent open reduction and screw or pin fixation were enrolled in this study. A 6.5 mm cancellous full threaded screw was inserted from the posteroinferior aspect of the calcaneal tuberosity to the posterior facet (group A) or Steinman pin was inserted from the posterosuperior aspect of the calcaneal tuberosity to the calcaneocuboidal joint (group B). Both preoperative and postoperative Bohler and Gissane angles were measured radiographically, and American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale on the final follow-up were assessed. Results: The mean age of patients was 44.1 years, and the mean follow-up period was 27.2 months. According to the Sanders classification, 28 cases were type II and 22 cases were type III. In Sanders type II, Bohler and Gissane angles improved significantly from $10.1^{\circ}$ and $126.2^{\circ}$ preoperatively to $27.2^{\circ}$ and $117.1^{\circ}$, respectively, in the immediate postoperative radiograph, and at the final follow-up, $26.6^{\circ}$ and $118.6^{\circ}$, respectively. In Sanders type III, Bohler and Gissane angles improved significantly from $5.0^{\circ}$ and $129.8^{\circ}$ to $29.9^{\circ}$ and $119.3^{\circ}$, respectively, in the immediate postoperative radiograph, and $26.9^{\circ}$ and $120.2^{\circ}$ at the final follow-up. All cases achieved bony union, and the average period until complete union was 13.3 weeks. AOFAS ankle-hindfoot scale was 82.6 in Sanders type II and 77.3 in Sanders type III at the final follow-up. Conclusion: A 6.5 mm cancellous full threaded buttress screw or Steinman pin fixation is a noninvasive treatment method with a merit of being able to maintain the bearing capacity of the posterior facet comparable to plate fixation.

지대주와 고정체의 체결방법에 따른 임플란트의 풀림거동에 관한 연구 (Effect of connection type on the screw loosening of implant system)

  • 최재민;전흥재;한종현;이수홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.486-491
    • /
    • 2004
  • A comparative study on the implant screw loosening under the initial clamping force and cyclic loads was conducted. The experiments were performed to evaluate the screw loosening behavior of the internal and external implant systems. It was found that the screw loosening torques of implant systems were significantly affected by the way how the abutment and fixture were connected due to the difference in the load transfer mechanism between abutment and fixture.

  • PDF