• Title/Summary/Keyword: Screw type

Search Result 547, Processing Time 0.025 seconds

Treatment of Ankle Lateral Malleolar Fractures Accompanying Osteoporosis using Lag Screw (골다공증과 동반된 족관절 외과 골절의 지연나사를 이용한 치료)

  • Lee, Jun-Young;Lee, Kwang-Chul
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.207-212
    • /
    • 2006
  • Purpose: To evaluate the results of ankle lateral malleolar fractures classified as Danis-Weber type B accompanying osteoporosis that were treated with lag screw. Materials and Methods: 15 cases of Danis-Weber type B ankle lateral malleolar fractures that had T score of less than -2.5 in BMD(bone mineral density) test were selected from June 2003 to December 2005. 10 cases were males and 5 cases were females with mean age of 59 years. The main injury mechanism was supination and external rotation. Mean follow-up period was 16 months. Clinical and radiologic evaluation was done according to Meyer and Kumler's criteria. Results: All cases showed satisfying result and mean radiologic bone union period was 3 months. Anatomic reduction and bone union was acquired in all cases without complications including wound infection, skin necrosis, delayed union and nonunion Conclusions: Lag screw fixation seem to be excellent treatment of Danis-Weber type B lateral malleolar fractures with osteoporosis as it can minimize soft tissue injury and enable anatomic reduction with firm fixation.

  • PDF

A Study on Improvement of Repeatability induced Thermal deformation of the ball screw (볼나사 열변형에 따른 반복정밀도 개선에 관한 연구)

  • 조규재
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.31-36
    • /
    • 1997
  • Thermal expansion of the ball screw in semi-closed loop type CNC Lathe directly affects the position precision along the travel axis. In this paper, the thermal displacement of the ball screw is estimated by using macro variables. The estimated displacements of the ball screw are managed by calculating the interval of pitch error rate in the NC. The thermal behaviour of the ball screw of the CNC Lathe, under the constant operating conditions, was measured to examine the effectiveness of this compensation method. The results showed that thermal displacement of the ball screw could be maintained its accuracy better than 6${\mu}{\textrm}{m}$ while applying this method.

  • PDF

A Study on Improvement of Accuracy of Positioning Induced Thermal Deformation of the Ball Screw in CNC Lathe (CNC 선반에서 볼 나사 열변형에 따른 위치결정 정도 개선에 관한 연구)

  • 홍성오
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.1
    • /
    • pp.45-51
    • /
    • 1999
  • Thermal expansion of the ball screw can directly affect the accuracy of positioning along the travel axis in the semi-closed loop type CNC Lathe. In this paper, use of MACRO variables can make the thermal displacement of the ball screw estimated. Also, the estimated displacements of the ball screw are controlled by calculating the interval of pitch error rate in the Numerical Control(NC). Under the constant operating conditions, the thermal expansion of the ball screw was measured to confirm the effectiveness of the compensation method in the CNC Lathe. By using this method the results show that the thermal displacement of the ball screw could be reduced to 20% compared with ordinary method.

  • PDF

Development of Devices of the Diversion Gate in Irrigation Canal (용수로 분수문 개폐장치 개발)

  • Jeon, Jong-Gil;Kim, Kyung-Won;Lee, In-Bok;Chun, Man-Bok
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.223-226
    • /
    • 2003
  • Devices of diversion gate used at irrigation canal, as a irrigation structures of agriculture, have shown serious problems such as corrosion, defect, inconvenience of operation, etc. Accordingly, handy devices of diversion gate have been developed and then tested in the laboratory. The operating types of the prototype were a rack-and-pinion type, an improved screw type that only gate plate was moved up and down while the screw axis was unmoved, and a remote control type which can be controlled from 50m away using a remote control system. Those 3 types were developed, and the improved screw type was shown the best operation through the laboratory tests.

  • PDF

THE STUDY ON THE IMPLANT GEOMETRY (3종의 임프란트 형태에 관한 연구)

  • Lee, Yong-Chan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.2
    • /
    • pp.245-252
    • /
    • 1996
  • The purpose of this study was to develop the implant which has superior stress distribution and primary stability to others by using Instron test and finite element method. The model used in the experiment were cylinder type implant, tapered screw type implant, screw type implants. Recognizing that the number of samples were small and the lack of applying press-fit conditions to the cylinder type, we can make the following conclusions.

  • PDF

Ozone Production Characteristics of the DBD Discharge the Electrode Shape at the Same Electrode surface area (동일한 전극 표면적에서 DBD방전형 내부전극 형상에 따른 오존생성특성 연구)

  • Kwon, Young-Hak;Park, Hyunmi;Song, HyunGig;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.71-77
    • /
    • 2016
  • The dielectric barrier discharge (DBD) has low efficiency due to about 70% input power is consumed as thermal energy in the discharge space. However, because of the usage of DBD ozone generator is easier than other methods. The DBD ozone generator has been widely applied for high concentration ozone generation in the industrial application. But, the low-capacity compact DBD ozone generator is not applied so far. Therefore, the DBD ozone generator is necessary to improve ozone production efficiency and reduce the capacity. In this paper, the stainless steel pipe inner electrode was designed with hall type and screw type to improve the ozone production yield. The manufactured two inner electrodes were experimented with normal type for comparison of the discharge characteristics and the ozone generating characteristics. As the experimental results, the discharge current effective value of designed inner electrodes with hall type and screw type are higher than the normal type, due to unequal electric field is formed at the boundary. However, the difference of designed and original electrodes is less than 0.1mA that has no effect on the discharge characteristic. On the other hand, the screw type inner electrode increased higher than original model about 7 times when the flow rate of the oxygen source gas was increased from $0.6{\ell}/min$ to $1.0{\ell}/min$ The reason was assumed by the flow rate of the raw gas through the inner electrode was became fast that has a cooling effect. The designed hall type and screw type inner electrodes have shown good performances in ozone generation and ozone production that better than normal type in the same electrode surface area.

Analysis of implant strain value exerted using different screw tightening protocols in screw-retained 3-unit prostheses (3본 나사 유지형 임플란트 보철물의 고정 방식에 따른 임플란트 고정체 치경부에 발생하는 변형율 비교분석)

  • Kim, Sang-Beom;Lee, Du-Hyeong;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.321-327
    • /
    • 2020
  • Purpose: The purpose of this study was to measure and compare the strain value exerted on the cervical area using different screw tightening protocols in implant-supported, screw-retained 3-unit prostheses. Materials and methods: Strain gauges were attached to four implants: two external and two internal. Thereafter, two study model were designed each type using acrylic resin. CAD-CAM was used to design hex and nonhex abutments for each group (EH, ENH, IH, and INH group) and Screw-cement-retained prostheses were also designed using a nonprecious base metal. Abutment was fixed with 10 Ncm torque, and the prosthesis was cemented. Screws were fixed with 30 Ncm torque using different three protocols. After 5 min, the strain gauge level was measured, and group analysis was performed (α=.05). Results: External group showed significantly lower strain values than internal group and the EH group showed significantly lower strain values than the ENH group (P<.05). There was no difference in strain value based on the types of screw tightening protocols in same group (P>.05). The IH group exhibited significantly higher strain values than the INH group and the IH group showed a significant difference in strain values based on the types of screw tightening protocols used (P<.05). Conclusion: There was no significant effect on the external type in the implant-supported, screw-retained prostheses. However, strain values were high in the internal type, and the types of screw tightening protocol significantly affected these implants.

A Study on Pullout Characteristics of Pedicle Screw Design Considering Anatomical Structure of the Lumbar Spine (척추의 해부학적 요소를 고려한 척추경 나사못 디자인의 Pullout 특성 연구)

  • Yoo, Kyeong-Joo;Park, Kwang-Min;Ahn, Kyoung-Gee;Ahn, Yoon-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Recently, various types of pedicle screws have been developed considering the anatomical structure of the spine. The purpose of this study was to evaluate the pullout stiffness and strength of two types of commercial pedicle screws. The design of two type screws were single pitched thread (ST) pedicle screw and dual pitched thread (DT) pedicle screw, respectively. The tests were conducted in accordance with the ASTM standards using polyurethane (PU) test blocks which has anatomical structure of the spine. There was no significant difference in pullout stiffness between two types of screw. However, DT exhibited higher pullout strength than ST (p<0.05). Pedicle screw with dual pitched thread showed higher pullout strength without decrease in pullout stiffness compared to the standard pedicle screw. In conclusion, dual pitched thread design of the pedicle screw is considered to be more suitable than the single pitched thread for the anatomical structure of the spine.

Percutaneous Acutrak Screw Fixation of Intra-articular Tongue Type Fracture of Calcaneus (설상형 관절내 종골 골절에 있어서 경피적 Acutrak 나사 고정을 이용한 수술적 치료)

  • Lee, Seong-Joo;Choi, Shin-Kwon;Yim, Moon-Sup;Hwang, Yoon-Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.1
    • /
    • pp.71-75
    • /
    • 2006
  • Purpose: To evaluate the results of treatments by percutaneous Acutrak screw fixation for intra-articular tongue type fracture of calcaneus, especially in elderly patient or patients with underlying disease including diabetes mellitus. Materials and Methods: Seven cases with intra-articular tongue type fracture of calcaneus, from November 2003 to February 2005, were reviewed. There were 6 males and 1 female with 65 years old mean age (range: $61{\sim}71$ years old). The average follow-up period was 16 months (range: $10{\sim}25$ months). Two Steinmann pins were used for closed reduction. After closed reduction was done like Essex-Lopresti's method, two Acutrak screws were inserted. The third Acutrak screw was inserted at the sustentaculum tali away from sinus tarsi to fix the primary fracture line. The patients were evaluated with Salama scale, the extent of recovery of Bohler angle, state of subtalar joint. Results: Clinical results according Salama scale were excellent in 5 cases, and good in 2 cases. Average preoperative Bohler angle was $13^{\circ}$ (range: $12{\sim}15^{\circ}$). Average postoperative Bohler angle was 31o (range: $23^{\circ}-40^{\circ}$). There were no soft tissue complications. There were two mild subtalar arthritis. Conclusions: We think that percutaneous Acutrak screw fixation is a good option for tongue type fracture of calcaneus in elderly patient or patients with underlying disease including diabetes mellitus.

  • PDF

A comparison of fixation methods using three-dimensional finite element analysis following anterior segmental osteotomy

  • Yun, Kyoung In;Park, Min-Kyu;Park, Myung-Kyun;Park, Je Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.6
    • /
    • pp.332-336
    • /
    • 2012
  • Objectives: This study sought to evaluate fixation methods and determine the best method for the postoperative stabilization of maxillary osteotomy. For our analysis we performed a three-dimensional finite element analysis of stress distribution on the plate, screw, and surrounding bone, as well as displacement onto the plate. Materials and Methods: We generated a model using synthetic skull scan data; an initital surface model was changed to a solid model using software. Modified anterior segmental osteotomy (using Park's method) was made using the program, and four different types of fixation methods were used. An anterior load of 100 N was applied on the palatal surface of two central incisors. Results: The Type 1 (L-shaped) fixation method gave stresses of 187.8 MPa at the plate, 45.8 MPa at the screw, and 15.4 MPa at the bone around the plate. The Type 2 (I-shaped) fixation method gave stresses of 186.6 MPa at the plate, 75.7 MPa at the screw, and 13.8 MPa at the bone around the plate. The Type 3 (inverted L-shaped) fixation method gave stresses of 28.6 MPa at the plate, 29.9 MPa at the screw, and 15.3 MPa at the bone around the plate. The Type 4 (I-shaped) fixation method gave stresses of 34.8 MPa at the plate, 36.9 MPa at the screw, and 14.9 MPa at the bone around the plate. The deflection of the plates for the four fixation methods was 0.014 mm, 0.022 mm, 0.017 mm, and 0.018 mm, respectively. Conclusion: The Type 3 (inverted L-shaped) fixation method offers more stability than the other fixation methods. We therefore recommend this method for the postoperative stabilization of maxillary osteotomy.