• Title/Summary/Keyword: Screw thread

Search Result 94, Processing Time 0.026 seconds

Experimental Study on the Safety of a Valve for a Special Gas Cylinder (특수가스용기용 밸브의 안전성에 관한 실험적 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.3
    • /
    • pp.14-19
    • /
    • 2013
  • This paper presents an experimental study on the safety of a valve for a special gas cylinder. The test valves that were randomly dismantled from the special gas cylinder were experimented on the gas leakage and operation safeties. The crack, wear and deformation of the valve body, screw thread, safety disk, vent hole, stem and handle components that may affect to the gas leakage safety of a used valve were not found in this experimental study. A painted handle of a valve was partly stripped from the coated surface, and the surface of PT screw of a used valve body was rusted. But, these paint and rust problems do not affected to the gas leakage safety of used valves. And there was no gas leakage in the dismantled valve, and the permanent deformation and partial scars of a valve stem and O-rings were observed on the rubbing surfaces. Thus, the valve seat and O-rings are recommended to be replaced for a gas leakage safety of a dismantled valve. And it is necessary to repair and inspect handle fastening forces for a safe opening and closing operations of a valve.

Evaluation of Bearing Strength of Self-Tapping Screws according to the Grain Direction of Domestic Pinus densiflora

  • LEE, In-Hwan;KIM, Keonho;SHIM, Kug-bo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • To evaluate the bearing strength of red pine cross-laminated timber (CLT) with self-tapping screw (STS), which is widely used as a fastener for connection in CLT building, the bearing test was conducted. Accoring to the STS's diameters (8, 10, 12 mm), the bearing test specimens with half hole were manufactured. Bearing strength was compared and reviewed in consideration of the configuration in STS and the loading direction to the grain of red pine. As a result of the bearing test on the STS's diameter, the yield bearing load increases as the larger diameter of the STS in all directions of the red pine. The bearing strength of the thread part (thread + tip) was higher than the shank part (shank + shank cutter). In compared with the directions to the grain of red pine, the bearing strength of the cross section parallel to the loading direction was the highest, and the tangent section was the lowest bearing strength. The average bearing strength of the loading direction in parallel to the grain was 23.43 MPa, which was about 45% higher than the average 16.16 MPa in perpendicular to the grain. The predicted bearing strength calculated by Eurocode (EN) and Korean Building Code (KBC)'s equation was lower than the experimental value. It is nessesary to propose the new equations of bearing strength reflected the configuration information of STS.

Experimental Study on Tensile Fatigue Strength of the High Strength Bolts (고장력볼트의 인장피로강도에 관한 실험적 연구)

  • Han, Jong Wook;Park, Young Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.165-170
    • /
    • 2008
  • New high strength bolts are required due to the development of the high strength steel, the ultra-thick steel plates, and the long-span bridge, though high strength bolts with tensile strength of 1,000 MPa are mainly used in construction site of every country. The high strength bolts are often subjected to a repeated tension-type of loading in which the fatigue failure is a major mode of failure. However, the theoretical and experimental study for the fatigue failure of tension bolt has not been well established in Korea. In this study, we performed a tensile fatigue test of F8T, F10T and F13T, F13T-N high strength bolts under tension. We proposed three fatigue strength specifications by performing 95% survival probability analysis for F8T, F10T, F13T, and F13T-N bolt under the $2{\times}10^6$ cycles of repeated loading. And the fatigue strength for the advanced screw thread shape bolt developed in this study are compared with the previous KS screw thread shape bolt.

Design of Cold Forging Process of Micro Screw for Mobile Devices (모바일 기기용 초소형 나사의 냉간 단조 공정 설계)

  • Choi, Du-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3692-3697
    • /
    • 2015
  • A screw is a type of fastener characterized by a helical ridge known as thread. The demands for screws with the miniaturization and weight reduction are increasing for the trend of small size of mobile devices. The successful designs of mold and process are very important to obtain screws with good mechanical properties and high precision. In this study, the design of cold forging process of micro screw was carried out by using finite element method. In particular, in order to investigate the effects of die geometries and friction, design of experiment method was adopted and it was revealed that the friction was the dominant factor of folding defects. From these results, the design of die was modified and experiments were carried out with the modified die. From the experimental results, it was found that the folding defects disappeared.

A comparison analysis of the stem lubricant performance for motor operated valve used in nuclear power plants (원자력발전소에서 사용중인 모터구동밸브 스템 윤활유의 성능 비교 분석)

  • Kim, Dae-Woong;Kim, Yang-Seok;Park, Chi Young;Lee, Sang Guk
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.2
    • /
    • pp.6-12
    • /
    • 2015
  • In this study, the performance test was carried out under various operation conditions targeting four representing types of lubricant which are mostly used in nuclear power plants, and mutually compared the characteristic and performance of lubricant. Especially, introducing the concept of the thread friction coefficient (hereinafter, TFC), which makes the friction relation between the stem nut and stem screw dimensionless. The test was performed to compare the lubricant performance for the four kinds of lubricant (Texaco, Alvania, Mobilux, MOVLL). In a test of the room temperature stem, the TFC of MOV Long Life shows the lowest value, next to Alvania EP2, Texaco EP2, and Mobilux EP0 in that order. And in a test of the high temperature stem, the TFC of Texaco EP2 shows the lowest, next to MOV Long Life, Alvania EP2, and Mobilux EP0 in that order. From the test result of the aging condition, three types of lubricant (MOV LL, Texaco EP2, Alvania EP2) show similar patterns up to 36 months, but in 60 months, the TFC of lubricant are increased rapidly.

FIT OF FIXTURE/ABUTMENT INTERFACE OF INTERNAL CONNECTION IMPLANT SYSTEM (내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구)

  • Lee Heung-Tae;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.192-209
    • /
    • 2004
  • Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.

A Study on Structural Safety Analysis of Hub Space (허브스페이스의 구조적 안전성 해석에 대한 연구)

  • Han, Moonsik;Cho, Jaeung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.3
    • /
    • pp.352-359
    • /
    • 2015
  • This study investigates the analysis result of structure and fatigue due to the models of the hub space with bolt joint at wheel and the existence or nonexistence of hub ring as the part of suspension system of vehicle. As the static analysis result, the structural vulnerability can be found at hub bolt and the center of wheel at three models. Model 2 and 3 have nearly same deformation and model 1 can be endured at the least load among three models. As the fatigue analysis result, fatigue lives of three models are same at the severest load of SAE bracket history. As many screw threads of weak bolts are jointed in case of model 1, model 1 is shown to be the weakest at fatigue damage among three models. By the result of this study, model 1 with bolt joint becomes most weakest among three models. As model 2 with no hub ring and model 3 with hub ring have the nearly same states of analysis results, hub ring is shown to have no influence on the safety of automotive driving.

Evaluation of the Structural Safety of a Vessel with Different Material(Cr-13)-Supplemented Screw Thread (이종재료가 보충된 나사산을 갖는 용기의 구조안전성 평가)

  • Choi, Yong Hoon;Bae, Jun Ho;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.375-382
    • /
    • 2015
  • The dome and neck part of a vessel is generally formed by a hot spinning process with a seamless tube. However, as studies on and design data from the hot spinning process are insufficient, this process has been performed based on trial and error and the experiences of field engineers. Changes in the inner diameter from the bottom to the top of the neck have occurred mainly because of the characteristics of the hot spinning process due to the high-speed rotation of the rollers. In this study, a theoretical and finite element analysis of the vessel is conducted with different material(Cr-13)-supplemented screw threads for tapping and to reduce shape errors. Based on the results, tne structural safety under the operating conditions is evaluated.

A Study on the In-Process Measurement of Rotary Body by Optical Technique (광학적 기법을 이용한 회전체 인프로세스 측정에 관한 연구)

  • So, Eui-Yeorl;Im, Young-Ho;Ryu, Bong-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.5
    • /
    • pp.148-156
    • /
    • 1996
  • Automatic product system is gradually increasing according to development of industrial society. On-line measurement makes a important role in view of economic and effective side in industrial product system. Syncronization system is developed to measure screw thread which is rotating. In-process measuring of rotating body have a lot of difficuties even thoufht using various method containing high speed camera. So, now we suggest one of the new method which is not so expansive. In this study, digital value was produced through the image processing algorithm from acquired orignal image. As a result, we have a good agreement between measuring values calculated from image conture and measuring values acquired from profile project by means of experiment, respectively.

  • PDF

Leakage-reduction Measures at a Joint between CPVC Piping for a Sprinkler System and a Pipe Expansion (스프링클러설비용 CPVC관과 신축배관 접속부분에서의 누수저감 대책에 관한 연구)

  • Lim, Chun-Ki;Lim, Yun-Tack;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.21-30
    • /
    • 2015
  • In this study, we try to suggest measures to reduce leakage at a joint between CPVC piping for a sprinkler system and a pipe expansion through reviews of domestic and foreign standards and related tests. The quality of the waterproof rubber packing material between a valve socket and pipe expansion nut was examined. In the leak test, the valve socket material over the expansion part of the metal pipe nut was found to use a metal part or a schlorinated polyvinyl chloride pipe nut part. In addition, the KS B 0221 standard for parallel pipe threads with threaded and thread inspection criteria and inspection standards in order to ensure an acceptable quality of valve socket, there is a need to amend the regulations to comply with the KS B 5223 (screw thread limit gauges parallel pipe threads). We do not have detailed standards for expansion piping nuts for waterproof rubber ring material, so we need to amend the relevant criteria for EPDM material to be used with excellent waterproofing, for which both NBR and EPDM are currently used.