• 제목/요약/키워드: Screw retained prosthesis

검색결과 43건 처리시간 0.03초

보철물 조건에 따른 Periotest수치의 실험적 평가 (IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES)

  • 한중석
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

Implant-supported fixed restoration of post-traumatic mandibular defect accompanied with skin grafting: A clinical report

  • Noh, Kwantae;Choi, Woo-Jin;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권1호
    • /
    • pp.67-72
    • /
    • 2013
  • Traumatic defects are mostly accompanied by hard and soft tissue loss. This report describes the surgical and prosthetic treatment of a patient with post-traumatic mandibular defect. A split-thickness skin graft was performed prior to implant placement and prefabricated acrylic stent was placed to hold the graft in place. The esthetic and functional demands of the patient were fulfilled by implant-supported screw-retained fixed prosthesis using CAD-CAM technology.

설측 슬롯을 부여한 임플란트 고정성 보철물에서 내면 간격이 유지력에 미치는 영향 (Effect of internal gap on retentivity in implant fixed prosthesis with lingual slot)

  • 김태균;이규복
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.206-211
    • /
    • 2018
  • 목적: 최근 임플란트 고정성 보철물 제작 시 나사 유지형 보철물의 교합적, 심미적 단점을 해결하고, 시멘트 유지형 보철물에서 착탈 용이성을 확보하기 위하여 보철물 설측에 슬롯을 형성하는 방법이 소개되었다. 이 연구의 목적은 설측 슬롯을 부여한 시멘트 유지형 임플란트 보철물 제작 시에 내면 간격이 보철의 제거에 어떤 영향을 미치는지 알아보는 것이다. 재료 및 방법: 티타늄 지대주와 상부에 합착할 지르코니아 보철물 내면 간격을 30, 35, $50{\mu}m$의 3종류로 설정하여 종류별로 3개씩 총 15개를 제작하였다. 지르코니아 보철물은 티타늄 지대주의 선반 부위와 만나는 위치에서 1 mm의 공간이 생기도록 하여 탈착을 위한 슬롯(retrievable cement-type slot, RCS)을 형성하였다. 지대주와 지르코니아 보철물의 합착에는 자가 중합 레진 시멘트를 이용하였고, 합착 된 시편을 맞춤 제작된 장비를 이용하여 최대 제거 응력 값을 Ncm단위로 측정하였다. 통계적 분석으로 세 그룹을 비교하기 위해 Kruskal-Wallis 검정을 시행하였고 (${\alpha}=.05$), 사후검정으로 수정된 Mann-Whitney U-test와 Bonferroni correction 방법을 이용하여 차이를 보았다 (${\alpha}=.017$). 결과: 내면 간격이 $30{\mu}m$ 군과 $35{\mu}m$ 군간의 비교에 있어서 제거 응력에 통계학적으로 유의한 차이가 없었고 (P = .032), $30{\mu}m$군과 $50{\mu}m$군, $35{\mu}m$군과 $50{\mu}m$군간을 비교 할 때 유의한 차이가 나타났다 (P < .017). 결론: 그러므로 내면 간격은 지르코니아 보철물과 티타늄 지대주 사이의 유지력에 영향을 미쳤다.

임플란트 보철물 나사의 전하중 유지에 나사 표면에 따른 혐기성 나사 고정제의 효과 (Effects of anaerobic sealing agents on preload maintenance of screw-retained implant prosthesis with surface of screws)

  • 류승범;허성주;곽재영;김성균
    • 대한치과보철학회지
    • /
    • 제58권2호
    • /
    • pp.103-109
    • /
    • 2020
  • 목적: 본 연구의 목적은 임플란트 지대주 나사에 혐기성 나사 고정제의 적용 유무와 나사 종류에 따른 풀림 토크 값의 차이를 평가하는 것이다. 재료 및 방법: 외부 육각형 임플란트 고정체를 사용하였고, 동일한 제조사의 지대주와 지대주 나사가 사용되었다. 지대주 나사는 두 종류로 티타늄 재질의 나사(티타늄 나사)와 텅스텐 카바이드 코팅된 나사(Ebony 나사)가 사용되었다. 티타늄 나사에 아무 처리하지 않은 군(TI군)과 티타늄 나사에 나사 고정제를 사용한 군(TI_AS군), Ebony 나사에 아무 처리하지 않은 군(EB군)과 Ebony 나사에 나사 고정제를 사용한 군(EB_AS군)에 대해 실험을 진행하였다. 총 4가지 군에서 각 10개씩의 임플란트 고정체-지대주 복합체가 사용되었다. 디지털 토크 측정 장비를 사용하여 풀림 토크 값을 측정한 뒤 통계 처리하여 각 군별 비교하였다. 정규성 분포를 만족하여 Two-way ANOVA test (α = .05)를 이용하여 통계 분석하였다. 결과: 각 군에 대한 결과를 살펴보면 TI 군은 20.3 ± 1.6 N.cm, TI_AS 군에서 32.4 ± 6.7 N.cm, EB 군은 20.2 ± 1.5 N.cm, EB_AS 군에서 30.4 ± 4.5 N.cm의 풀림 토크 값을 나타냈다. 결론: 혐기성 나사 고정제를 사용한 경우 티타늄 나사와 ebony 나사 모두에서 고정제를 사용하지 않은 경우 보다 풀림 토크 값이 높게 나타났다. 하지만 두 나사 군 간의 차이는 존재하지 않았다.

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).

THE MANAGEMENT OF A COMPLEX IMPLANT CASE USING CAD-CAM TECHNOLOGY: A CLINICAL REPORT

  • Park, Eun-Jin
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.634-638
    • /
    • 2008
  • PURPOSE: The application of computer-aided technology to implant dentistry has created new opportunities for treatment planning, surgery and prosthodontic treatment, but the correct selection and combination of available methods may be challenging in times. Hence, the purpose of this case report is to present a combination of several computer-aided tools as approaches to manage complicated implant case. MATERIAL AND METHODS: A 47 year-old female patient with severe dental anxiety, high expectations, financial restrictions and poor compliance presented for a fixed rehabilitation. A CT scan with a radiographic template obtained with software (SimPlant, Materialize, Leuven, Belgium) was used for treatment planning. The surgical plan was created and converted into a stereolithographic model of the maxilla with bone-supported surgical templates (SurgiGuide, Materialise, Leuven, Belgium), that allowed for the precise placement of 7 implants in a severely resorbed edentulous maxilla. After successful osseointegration, an accurate scan model served as the basis for the fabrication of a one-piece milled titanium framework using the Procera (Nobel Biocare, Gothenburg, Sweden) technology. The final rehabilitation of the edentulous maxilla was rendered in the form of a screw-retained maxillary metal-reinforced resin-based complete prosthesis. RESULTS: Despite challenging circumstances, 7 implants could be placed without bone augmentation in a severely resorbed maxilla using the SimPlant software for pre-implant analysis and the SurgiGuide-system as the surgical template. The patient was successfully restored with a fixed full arch restoration, utilizing the Procera system for the fabrication of a milled titanium framework.

Monolithic zirconia framework으로 제작된 fixed detachable prostheses를 이용한 심미적인 임플란트 전악 수복 증례 (Esthetic Full Zirconia Fixed Detachable Implant-Retained Restorations Manufactured from Monolithic Zirconia : Clinical Report)

  • 홍준태;최유성;한세진;조인호
    • 구강회복응용과학지
    • /
    • 제28권3호
    • /
    • pp.253-268
    • /
    • 2012
  • 수직적, 수평적 골흡수가 심한 환자에서 임플란트를 이용한 전악수복의 경우 경조직과 연조직 이식을 통해서 임플란트를 원하는 위치에 식립할 수도 있지만, 치은과 치아의 기능과 심미를 회복할 수 있는 fixed detachable prostheses를 대체 술식으로 사용할 수도 있다. 이러한 증례에서 다양한 재료가 수복물의 제작에 사용 가능하지만, metal/acrylic 보철물에서는 레진치아의 파절 및 탈락이 일어날 수 있고, metal/ceramic 혹은 zirconia/ceramic 보철물에서는 도재의 chipping이나 파절과 같은 문제가 발생할 수 있다. 이에 최근에 심미적이면서도 기능적인 보철수복을 위해 zirconia에 도재를 축성하지 않고 임상적으로 적용가능한 monolithic zirconia framework이 출시되어 사용되고 있다. 본 임상 증례는 심미적인 요구도가 높은 완전 무치악 환자에서 임플란트를 식립하고 chipping이나 파절의 위험을 감소시키기 위해 monolithic zirconia framework을 이용해 만들어진 complete fixed detachable 보철물을 이용한 수복에 대해 보고하고자 한다. 이번 증례에서 보철물은 심미적, 기능적으로 만족스러웠으며, 2년 간의 정기검사에서 임상적인 합병증은 보고되지 않았다.

다수의 임플란트발거로 임플란트 고정성 보철이 실패한 환자에서의 잔존 임플란트를 이용한 부분 가철성 국소의치 수복증례 (Case report: Application of Implant Supported Removable Partial Denture due to Multiple Dental Implant Loss of the Fixed Implant Supported Prosthesis)

  • 강정경;남기훈
    • 대한심미치과학회지
    • /
    • 제23권1호
    • /
    • pp.34-40
    • /
    • 2014
  • 부분 무치악을 수복하는 데 있어서 선택할 수 있는 치료의 옵션으로는 전통적인 국소의치와 임플란트 지지-고정성 보철물 등이 있다. 하지만, 환자의 전신적 또는 구강의 상태(수술적인 술식이 제한되는 전신병력, 지지조직의 부족 그리고 골유착에 실패한 임플란트)와 치료비용에 대한 허용 정도에 따라 모든 옵션이 항상 가능한 것은 아니다. 가철성 국소의치는 임플란트 고정성 보철물에 비해 구강위생 관리 및 상,하악 악간관계의 부조화를 수정하기에 편리한 장점이 있다. 최근에는 전략적 위치에 임플란트를 식립하여 기존 악궁 형태에서는 제한되는 국소의치 디자인의 한계를 개선할 수 있는 임플란트지지형 RPD(Implant Supported Removable Partial Denture)가 새로운 방안으로 대두되고 있다. ISRPD는 전략적 위치에 임플란트를 식립하여 역학적인 한계를 극복할 수 있을 뿐 만 아니라 전악의 임플란트지지형 고정성 보철이 제한되는 환자에서 보다 경제적이고 현실적인 보철적 해결책이 될 수 있다. 따라서, RPD를 이용한 보철계획 수립시 전략적 위치에서의 임플란트의 사용은 고전적인 가철성 국소 의치에서보다 유지력과 안정성을 증진시키고 구강위생관리 또한 용이하여 환자의 적응도를 높이는 방안으로 고려될 수 있다. 본 증례는 상악 양측 구치부의 임플란트 고정성 보철,하악의 bar-type overdenture를 사용중이던 59세 남성환자에서 상악 #15i임플란트의 abutment screw fracture와 임플란트의 골유착 실패로 인한 다수 임플란트를 발거 후 남은 #15i,24i,25,26,i의 잔존 임플란트와 #23 자연치를 활용해 상악에 ISRPD를 적용한 경우이다. #23 surveyed crown, #24i=25i=26i surveyed bridge 및 #15i에 gold coping을 제작하여 국소의치의 지지와 유지,안정을 도모하였다.최종 보철물을 장착하고 2년간 주기적인 follow up 통해 예후를 관찰중이며 지대치로 사용한 임플란트에서 screw loosening이나 파절, 골흡수 등의 증상은 현재까지 관찰되지 않았다.

THE EFFECT OF ABUTMENT HEIGHT ON SCREW LOOSENING IN SINGLE IMPLANT-SUPPORTED PROSTHESES AFTER DYNAMIC CYCLIC LOADING

  • Kim Nam-Gun;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.664-670
    • /
    • 2004
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection. Purpose. The purpose of this study was to examine the changes of detorque values of abutment screws with external connection in different abutment heights. Materials and methods. After cyclic loading on three different abutment heights, detorque values were measured. Abutments were retained with titanium abutment screws tightened to 30 Ncm (30.5 kgmm) with digital torque gauge as recommended by the manufacturer. Replacing abutments, implants and titanium abutment screws with new ones at every measurement, initial detorque values were measured six times. In measuring de torque values after cyclic loading, Avana Cemented Abutments of 4.0 mm collar, 7.0 mm height (Osstem Co., Ltd., Seoul, Korea) were used with three different lengths of 5.0, 8.0, 11.0 mm. Shorter abutments were made by milling of 11.0 mm abutment to have the same force-exercised area of 4.5 mm diameter. Sine curve force (20N-320N, 14Hz) was applied, and detorque values were measured after cyclic loading of 2 million times by loading machine. Detorque values of initial and after-loading were measured by digital torque gauge. One-way ANOVA was employed to see if there was any influence from different abutment heights. Results. The results were as follows: 1. The initial detorque value was 27.8$\pm$0.93 kgmm, and the ratio of the initial detorque value to the tightening torque was 0.91(27.8/30.5). 2. Measured detorque values after cyclic loading were declined as the height of the abutment increased, that was, 5.0 mm; 22.3$\pm$0.82 kgmm, 8.0 mm; 21.8$\pm$0.93 kgmm, and 11.0 mm; 21.3$\pm$0.94 kgmm. 3. One-way ANOVA showed no statistically significant differences among these (p>0.05). 4. Noticeable mobility at the implant-abutment interface was not observed in any case after cyclic loading at all.

Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants

  • Young-Min Kim;Jong-Bin Lee;Heung-Sik Um;Beom-Seok Chang;Jae-Kwan Lee
    • Journal of Periodontal and Implant Science
    • /
    • 제52권6호
    • /
    • pp.496-508
    • /
    • 2022
  • Purpose: This study aimed to compare the long-term survival rate and peri-implant marginal bone loss between different types of dental implant-abutment connections. Methods: Implants with external or internal abutment connections, which were fitted at Gangneung-Wonju National University Dental Hospital from November 2011 to December 2015 and followed up for >5 years, were retrospectively investigated. Cumulative survival rates were evaluated for >5 years, and peri-implant marginal bone loss was evaluated at 1- and 5-year follow-up examinations after functional loading. Results: The 8-year cumulative survival rates were 93.3% and 90.7% in the external and internal connection types, respectively (P=0.353). The mean values of marginal bone loss were 1.23 mm (external) and 0.72 mm (internal) (P<0.001) after 1 year of loading, and 1.20 mm and 1.00 mm for external and internal abutment connections, respectively (P=0.137) after 5 years. Implant length (longer, P=0.018), smoking status (heavy, P=0.001), and prosthetic type (bridge, P=0.004) were associated with significantly greater marginal bone loss, and the use of screw-cement-retained prosthesis was significantly associated (P=0.027) with less marginal bone loss. Conclusions: There was no significant difference in the cumulative survival rate between implants with external and internal abutment connections. After 1 year of loading, marginal bone loss was greater around the implants with an external abutment connection. However, no significant difference between the external and internal connection groups was found after 5 years. Both types of abutment connections are viable treatment options for the reconstruction of partially edentulous ridges.