• 제목/요약/키워드: Screw joint

검색결과 204건 처리시간 0.033초

족근-중족 관절 골절 탈구의 치료경험 (Treatment for Tarsometatarsal Fracture-Dislocation)

  • 정영기;유정한;박용욱;노동근;하성한
    • 대한족부족관절학회지
    • /
    • 제1권2호
    • /
    • pp.112-118
    • /
    • 1997
  • Tarsometatarsal fracture-dislocation is uncommon but severe lesion. Since this lesion is sometimes difficult to recognize by roentgenography, it is easily overlooked. Three patients were treated with open reduction and internal fixation with 3.5 mm cannulated screw and K-wire, two had treatment with open reduction and internal fixation with 3.5 mm cannulated screw only and two had treatment with dosed reduction and short leg cast only between January 1994 and May 1996. The duration of follow-up ranged from twelve to twenty-nine months after the diagnosis. Results were assessed by a subjective questiormaire, physical examination, and radiographic analysis. Multiple fixation techniques for maintaining the reduction of tarsometatarsl joint have been introduced. We recent]y used the 3.5 mm cannulated screw for internal fixation of the tarso-first and second metatarsal fracture-dislocation. We think cannulated screw fixation has several advantages; 1. The cannulated screw fixation is more rigid than the K-wire fixation. 2. There is an decreased risk of screw breakage with early weight bearing. 3. It is possible to compress the involved joints, if necessary. There were no disability in all patients. One patient who was treated with delayed open reduction and internal fixation with 3.5 mm cannulated screw and K-wire had a radiographic mild degenerative arthritis. And one patient who was treated with dosed reduction and short leg cast had a mild metatarsus adductus. But. these two patients were symptom free. There was no correlation between the severity of the diastasis and the patient s functional result.

  • PDF

임플란트 나사의 안정성 (Stability of implant screw joint)

  • 정재헌;곽종하;장두익
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.125-137
    • /
    • 2003
  • The use of screw-retaind prosthesis on an osseointegrated implant is a popular treatment modality offering relative ease in the removal of the restoration. One of the complications associated with this modality is the loosening of the abutment and coping screws. Loosening of the screws results in patient dissatisfaction, frustration to the dentist and, if left untreated, component fracture. There are several factors which contribute to the loosening of implant components which can be controlled by the restorative dentist and lab technician. This article offers pratical solutions to minimize this clinical problem and describes the factors involved in maintaining a stable screw joint assembly. To avoid joint failure, adherence to specific clinical, as well as mechanical, parameters is critical. With respect to hardware, optimal tolerance and fit, minimal rotational play, best physical properties, a predictable interface, and optimal torque application are mandatory. In the clinical arena, optimal implant distribution; load in line with implant axis; optimal number, diameter, and length of implants; elimination of cantilevers; optimal prosthesis fit; and occlusal load control are equally important.

Freehand S2 Alar-Iliac Screw Placement Using K-Wire and Cannulated Screw : Technical Case Series

  • Choi, Ho Yong;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권1호
    • /
    • pp.75-80
    • /
    • 2018
  • Objective : Among the various sacropelvic fixation methods, S2 alar-iliac (S2AI) screw fixation has several advantages compared to conventional iliac wing screw. However, the placement of S2AI screw still remains a challenge. The purpose of this study was to describe a novel technique of free hand S2AI screw insertion using a K-wire and cannulated screw, and to evaluate the accuracy of the technique. Methods : S2AI screw was inserted by free hand technique in sixteen consecutive patients without any fluoroscopic guidance. The gearshift was advanced to make a pilot hole passing through the sacroiliac joint and directing the anterior inferior iliac spine. A K-wire was placed through the pilot hole. After introducing a cannulated tapper along with the K-wire, a cannulated S2AI screw was installed over the K-wire. Results : Thirty-three S2AI screws were placed in sixteen consecutive patients. Thirty-two screws were cannulated screws, and one screw was a conventional non-cannulated screw. Thirty out of 32 (93.8%) cannulated screws were accurately positioned, whereas two cannulated screws and one non-cannulated screw violated lateral cortex of the ilium. Conclusion : The technique using K-wire and cannulated screw can provide accurate placement of free hand S2AI screw.

임플랜트의 지대주 연결방식, 임플랜트의 직경 및 지대주 연결부위의 직경 차이에 따른 응력분포에 관한 삼차원 유한요소분석 (INFLUENCE OF IMPLANT-ABUTMENT INTERFACE DESIGN, IMPLANT DIAMETER AND PROSTHETIC TABLE WIDTH ON STRENGTH OF IMPLANT-ABUTMENT INTERFACE : THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS)

  • 오세웅;양재호;이선형;한중석
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.393-404
    • /
    • 2003
  • Statement of problem. Higher incidence of prosthetic complications such as screw loosening, screw fracture has been reported for posterior single tooth implant. So, there is ongoing research regarding stability of implant-abutment interface. One of those research is increasing the implant diameter and prosthetic table width to improve joint stability. In another part of this research, internal conical type implant-abutment interface was developed and reported joint strength is higher than traditional external hex interface. Purpose. The purpose of this study is to compare stress distribution in single molar implant between external hex butt joint implant and internal conical joint implant when increasing the implant diameter and prosthetic table width : 4mm diameter, 5mm diameter, 5mm diameter/6mm prosthetic table width. Material and method. Non-linear finite element models were created and the 3-dimensional finite element analysis was performed to see the distribution of stress when 300N static loading was applied to model at $0^{\circ},\;15^{\circ},\;30^{\circ}$ off-axis angle. Results. The following results were obtained : 1. Internal conical joint showed lower tensile stress value than that of external hex butt joint. 2. When off-axis loading was applied, internal conical joint showed more effective stress distribution than external hex butt joint. 3. External hex butt joint showed lower tensile stress value when the implant diameter was increased. 4. Internal conical joint showed lower tensile stress value than external hex butt joint when the implant diameter was increased. 5. Both of these joint mechanism showed lower tensile stress value when the prosthetic table width was increased. Conclusion. Internal conical joint showed more effective stress distribution than external hex joint. Increasing implant diameter showed more effective stress distribution than increasing prosthetic table width.

진행된 무지 강직증에서 생체흡수성 압박나사를 이용한 원위 중족골의 배측 쐐기 절골술 (The Distal Metatarsal Dorsal-Wedge Osteotomy Using Bio-Compression Screw for Advanced Hallux Rigidus)

  • 김용민;조병기;김동수;최의성;손현철;박경진;박지강;최승명
    • 대한족부족관절학회지
    • /
    • 제16권1호
    • /
    • pp.38-46
    • /
    • 2012
  • Purpose: This study was performed retrospectively to evaluate clinical outcomes of distal metatarsal osteotomy using bio-compression screw as the joint preservation method for advanced hallux rigidus. Materials and Methods: Eleven cases were followed up for more than 1 year after distal metatarsal dorsal wedge osteotomy for advanced hallux rigidus. The clinical evaluation was performed according to the American Orthopaedic Foot and Ankle Society (AOFAS) score and patient's satisfaction score. The range of motion, and the period to return to running exercise, tip-toeing gait, squatting, walking down the stairs were evaluated. As the radiographic evaluation, the interval of $1^{st}$ MTP (metatarsophalangeal) joint space and the period to union were measured. Results: The AOFAS hallux score had improved significantly from preoperative average 50.7 points to 87.6 points at the last follow-up (p=0.005). The subjective satisfaction score was average 90.6 points. There were no case of subsequent fusion or additional operation, and no complication associated with bio-compression screw. The period to return to running exercise, tip-toeing gait, squatting, walking down the stairs were average of 24.8 weeks, 20.4 weeks, 16.8 weeks, 18.5 weeks respectively. Dorsiflexion of $1^{st}$ MTP joint had improved significantly from preoperative average $17.5^{\circ}$ to $44^{\circ}$ (p<0.001). All cases achieved union of osteotomy site, and the period to union was average 10.4 weeks. The interval of $1^{st}$ MTP joint space had improved significantly from preoperative average 1.2 mm to 3.5 mm (p=0.014). Conclusion: Distal metatarsal osteotomy using bio-compression screw seems to be one of effective treatment methods for advanced hallux rigidus, because of restoration of the first MTP joint motion, and reliable pain relief, and needlessness of hardware removal.

볼나사 구동기를 이용한 다관절 로봇의 모델링 및 제어 (Modeling & Control of a Multi-Joint Robot actuated by the Ball Screw)

  • 최형식;김영식;전대원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.323-326
    • /
    • 1997
  • Conventional robots actuated by motors with the speed reducer such as harmonic drive had weakness in delivering loads, pressing, grinding, and cutting jobs. To overcome this, the developer a new type of robot actuated by the ball screw. The robot is an articulated shape, which is composed of four axes. The base axis is actuated similarly with conventional robot, but the others are actuated by four bars mechanism composed of the ball screw. We setup the dynamics model of the robot. The robot has parameter uncertainties and nonlinearlity due to the ball screw actuator. To coordinate the robot, we applied sliding-mode control.

  • PDF

경비 인대 결합 나사못의 이상적인 삽입부위 (Ideal Insertion Position of Ankle Syndesmosis Screw)

  • 박홍기;문선상
    • 대한족부족관절학회지
    • /
    • 제6권1호
    • /
    • pp.60-65
    • /
    • 2002
  • Purpose: The purposes of the present study were to find the ideal insertion position syndesmosis screw and relation to the surrounding anatomical structures when indirectly inserting the screw anteriorly at a 30 angle at 3 cm proximal portion of the ankle join t. Materials and Methods: We performed computed tomography from the axial view in 20 normal individuals at 3 cm proximal portion of the ankle joint and divided the lateral side of the fibula into 4 sections. We drew a line from the middle of each of these 4 sections to the posterolateral tibia at a 30 angle and determined the relationship between each of these lines and the surrounding anatomical structures and confirmed the site at which each of these 4 lines passed through the posterolateral tibia which divided into 3 sections and the site of the fibula at which each of these lines passed through the middle 1/3 portion of the tibia. Results: The posterior 3/4 portion of the fibula that passed through the middle 1/3 portion of the posterolateral tibia in 18 cases. The portion did not approach the surrounding anatomical structures(Peroneal vessels and the muscular portion of FHL). Conclusion: The ideal insertion position of syndesmosis screw at 3 cm proximal portion of the ankle joint at a 30 angle is the posterior 3/4 portion of the lateral side of the fibula, and injury to the surrounding anatomical structures could be avoided when the screw passes through the middle 1/3 portion of the posterolateral tibia.

  • PDF

무지 외반증의 치료에서 단일 나사못을 이용한 근위 중족골 쐐기 절골술 (Proximal Metatarsal Wedge Osteotomy with Single Screw Fixation in Treatment of Hallux Valgus)

  • 최재열;신헌규;장일성;강동호
    • 대한족부족관절학회지
    • /
    • 제9권1호
    • /
    • pp.87-93
    • /
    • 2005
  • Purpose: We conducted this study to examine the clinical results of the proximal metatarsal wedge osteotomy using a single screw fixation and the distal soft tissue procedure in patients with moderate to severe hallux valgus deformity. Materials and Methods: Between February 2002 and February 2004, we performed these procedures on 12 patients (15 cases). The 6 cases of all patients had mild to moderate instability in the first MTC (metatarsocuneiform) joint. We estimated the clinical outcomes, the radiological findings and complications. Results: AOFAS score was improved from preoperative 41.5 points to 87.7 points lastly on average. The mean correction angle of HVA and IMA was $23.8^{\circ}$ and $6.6^{\circ}$, respectively. The mean position of tibial sesamoid was 2.67 before surgery and 0.87 after surgery. The mean shortening of the first metatarsal bone was 3.07 mm after surgery. There was no pain and complications on the first MTC joint except the breakage of screw in one case and instability of the first MTC joint was improved postoperatively. Conclusion: We obtained good clinical and radiographic outcomes in our series. So, proximal metatarsal wedge osteotomy using a single screw fixation and distal soft tissue procedure seems one of the good surgical treatments for moderate hallux valgus deformity.

  • PDF

하악 과두 골절 환자에서 Lag Screw를 이용한 치료시 예후에 관한 임상적 연구 (CLINICAL STUDY OF PROGNOSIS USING LAG SCREW OSTEOSYNTHESIS IN MANDIBULAR CONDYLE FRACTURE)

  • 이동근;민승기;배진오;양희창
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제19권2호
    • /
    • pp.157-166
    • /
    • 1997
  • Treatment of condylar fracture is still controversial, but the indication of surgical mangement is increased due to improved fixation methods and surgical techniques. In this article, we report our clinical and radiological results with the use of lag screw osteosynthesis for fixation of fractured mandibular condyle. 12 case of condyle fracture treated by open reduction and fixation with lag screw were monitored for an average of 10 months (range from 6 months to 19 months) postoperatively. The obtained results are as follows : 1. Postoperative maximum mouth opening is achieved over 40mm except one patient. 2. Although slight crepitus and deviation of mandible during mouth opening were found, Temporomandibular joint problem is satisfactory in all but one patient. 3. Distal migration of screw and resorption of fractured fragment were found in each 2 patients, but good functional recovery was achieved in all. According to the above results, we think that lag screw osteosynthesis is relatively indicated in level III or IV condylar fracture.

  • PDF

EFFECT OF TIN COATING OF ABUTMENT SCREW ON DETORQUE FORCE

  • Kim, Hee-Jung;Choe, Han-Cheol;Chung, Chae-Heon
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.329-338
    • /
    • 2007
  • Purpose. The aim of this study is to evaluate the effect of TiN coating of abutment screw on the unscrewing torque. Material and methods. Titanium and Gold-Tite abutment screws were classified into two groups, Group A and C respectively, as control groups. Titanium abutment screws with TiN coatings were also classified into two groups, Group B and D, as experimental ones. Group A and B were tightened to 20 Ncm input torque, and Group C and D were tightened to 32 Ncm torque. Detorque values were measured with digital torque gauge during repeated closing and opening experiment. Results. Abutment screws with TiN coating (Group B and D) showed statistically significant higher mean detorque values than those of Group A and C. Discussion. Physical properties of TiN coating, such as low friction coefficient, high hardness and wear resistance, might contribute to higher detorque values. Conclusion. It is suggested that TiN coating of abutment screw help to reduce the risk of screw loosening and improve the stability of screw joint.