• 제목/요약/키워드: Screw cap

검색결과 13건 처리시간 0.03초

소형 Screw Cap Opener 개발에 관한 연구 (A Study on the Development of a Small Screw Cap Opener)

  • 손병창;신승헌;이용태
    • 대한인간공학회지
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2006
  • The effectivenes of the opener has also been evaluated. The developed opener increased the torque capability of the wrist by 3.2 times so that most of the elderly can open screw caps. In this study the range of the screw cap sizes tested were between 22.0~ 32.0m, which covers over 92.0% of the screw caps in the market that are difficult to open. This particular screw cap opener developed in this study applies to the aged asstrength.

위성용 소켓헤드 캡 스크류 개발 및 검증 (Development and Verification of Socket Head Cap Screw for Satellite Applicaiton)

  • 이춘우;조영준;이창호;황도순
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.129-137
    • /
    • 2010
  • 본 논문은 위성용으로 주로 사용되는 소켓헤드 캡 스크류에 대한 국산화 개발 절차를 소개하는 내용이다. 국산화 개발을 위한 소켓헤드 캡 스크류의 제조공정은 MIL-B-7838, ECSS-Q-70-46A, KS W 8168과 같은 항공우주 관련 규격 요구조건을 만족하기 위해서 헤드 포밍 공정, 열처리공정, 전조 공정 및 후처리 공정으로 구성하였다. 그리고 국산화 스크루에 대한 품질 검증을 위하여 여러 가지 종류의 품질검증시험을 성공적으로 완료하였다. 또한, 비국산화 해외 도입 스크류와의 비교 품질시험을 통하여, 국산화 소켓 헤드 캡 스크류 품질이 항공우주용으로 적용 가능한 우수한 품질 성능을 확인 하였다.

직결나사 연결 접합부에 관한 구조성능평가 연구 (A Study of Structural Performance of Self-Drilling Screw Connections)

  • 박기연;전상현;김영호;최성모
    • 한국강구조학회 논문집
    • /
    • 제25권5호
    • /
    • pp.543-553
    • /
    • 2013
  • 춤이 깊은 골형 데크는 그 단면의 형태가 개방형 단면(개단면(開斷面))으로 단면의 불안정성에 의한 휨비틀림 등의 구조적 문제를 일으킬 수 있다. 박판의 냉간성형강인 데크와 캡플레이트의 접합에 사용되는 연결재(파스너)는 볼트, 리벳, 용접 그리고 나사 접합이 있다. 이 연구는 냉간성형강을 사용한 춤이 깊은 데크와 보강용 캡플레이트간의 직결나사 접합부에 관한 실험적 연구로, 직결나사 접합부의 파괴거동과 최대내력에 영향을 주는 직결나사 배치방법, 직결나사 수, 직결나사 간격 그리고 직결나사 머리밑판의 두께변화를 실험변수로 하여 국외 설계기준식 비교 분석하고자 한다.

초소형 디플렉터 타입 볼스크류 개발을 위한 해석에 관한 연구 (A Study on the Analysis for Development of a Deflector Type Miniature Ball Screw)

  • 이춘만;문성호;이영훈;김준환
    • 한국정밀공학회지
    • /
    • 제33권12호
    • /
    • pp.979-984
    • /
    • 2016
  • Recently, ball screws have been used in machine tools, robot parts, and medical instruments. The demand for ball screws of high precision and reduced size is increasing because of the growth of high value-added industries. Three types of ball screws are typically used: deflector type, end-cap type, and tube type. They are also classified from C0 to C9 according to the precision level. A deflector type ball screw can reduce the variation of rotational torque and the size of the nut of the ball screw is minimized. To ensure the reliable design of ball screws, it is important to perform a structural analysis. The purpose of this study is to perform a stability evaluation through analysis of a deflector type miniature ball screw for weapon systems. The analysis is performed through Finite Elements Method (FEM) simulation to predict characteristics such as deformation, stress, and thermal effects. The interference between the shaft and the deflector for smooth rotation are also studied. Based on the results of the analysis, the development of the deflector type miniature ball screw for weapon systems is performed.

THE ASSESSMENT OF ABUTMENT SCREW STABILITY BETWEEN THE EXTERNAL AND INTERNAL HEXAGONAL JOINT UNDER CYCLIC LOADING

  • Lee, Tae-Sik;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jae-Bong;Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.561-568
    • /
    • 2008
  • STATEMENT OF PROBLEM: Currently, many implant systems are developed and divided into two types according to their joint connection: external or internal connection. Regardless of the connection type, screw loosening is the biggest problem in implant-supported restoration. PURPOSE: The purpose of this study is to assess the difference in stability of abutment screws between the external and internal hexagonal connection types under cyclic loading. MATERIAL AND METHODS: Each of the 15 samples of external implants and internal abutments were tightened to 30 N/cm with a digital torque gauge, and cemented with a hemispherical metal cap. Each unit was then mounted in a $30^{\circ}$ inclined jig. Then each group was divided into 2 sub-groups based on different periods of cyclic loading with the loading machine (30 N/ cm - 300 N/cm,14 Hz: first group $1{\times}10^6$, $5{\times}10^6$ cyclic loading; second group $3{\times}10^6$, $3{\times}10^6$ for a total cyclic loading of $6{\times}10^6$) The removal torque value of the screw before and after cyclic loading was checked. SPSS statistical software for Windows was used for statistical analysis. Group means were calculated and compared by ANOVA, independent t-test, and paired t-test with ${\alpha}$=0.05. RESULTS: In the external hexagonal connection, the difference between the removal torque value of the abutment screw before loading, the value after $1{\tims}10^6$ cyclic loading, and the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was not significant. The difference between the removal torque value after $3{\times}10^6$ cyclic loading and after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. In the internal hexagonal connection, the difference between the removal torque value before loading and the value after $1{\times}10^6$ cyclic loading was not significant, but the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was reduced and the difference was significant (P < .05). In addition, in the internal hexagonal connection, the difference between the removal torque value after $3{\times}10^6$ cyclic loading and the value after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. CONCLUSION: The external hexagonal connection was more stable than the internal hexagonal connection after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading (t = 10.834, P < .001). There was no significant difference between the two systems after $3{\times}10^6$, and additional $3{\times}10^6$ cycles.

전단파와 전자기파를 이용한 연약 지반의 실내 압밀 특성 평가 (Evaluation of Consolidation Properties in Soft Soils Using Elastic and Electromagnetic Waves)

  • 이창호;윤형구;김준한;이종섭
    • 한국지반공학회논문집
    • /
    • 제24권8호
    • /
    • pp.25-34
    • /
    • 2008
  • 연약 지반의 거동 특성 평가를 위하여 전단파 속도와 전기저항을 측정할 수 있는 새로운 압밀셀을 개발하였다. 전단파의 발진과 수신을 위한 벤더엘리먼트는 압밀셀의 상 하부판 및 벽면에 설치하였다. 국부적인 간극비 변화를 평가하기 위하여 이중 쐐기 형식의 전기저항 탐침을 적용하였다. 벤더 엘리먼트와 전기저항 탐침은 나일론 재질의 스크류 안에 고정하였다. 나일론 재질의 스크류는 압밀셀과의 임피던스 차이로 인하여 압밀셀을 통한 파의 직접적 전달을 최소화하며, 고장난 벤더 엘리먼트와 전기저항 탐침을 쉽게 교환하게 해준다. 전기저항-대수 시간 곡선의 기울기 및 전단파 속도의 변화로부터 일차 압밀 시간을 평가하였다. 교란 효과가 적을 경우, 입자 배열은 전단파 속도에 영향을 미치며 이로부터 흙의 고유 이방성을 평가할 수 있었다. 압밀 실험동안 침하량으로 산정한 간극비와 전기저항으로부터 계산된 간극비는 거의 유사한 것으로 나타났다. 본 연구는 전단퐈 속도와 전기저항이 일차 압밀, 고유 이방성, 간극비 등 연약 지반의 압밀 특성 파악을 위한 보완적인 정보를 제공해 줌을 보여준다.

MCCB 단자 접속부의 접촉불량에 의한 과열사고 방지기법에 관한 연구 (Research on Overheat Protection Techniques of Connection Parts of MCCB by Poor Contact)

  • 김동우;이기연;문현욱;김향곤;최충석
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.54-60
    • /
    • 2008
  • 본 논문에서는 MCCB 및 단자대 접속부의 접촉불량에 의한 소손특성을 분석하였으며, 발열을 감지하여 화재를 예방할 수 있는 다양한 기법들을 제시하였다. 첫째로, 열전대를 사용하는 방법과 적외선 열화상기를 사용하여 접촉불량 등의 원인에 의해서 발열을 감지하는 방법을 분석하였다. 또한, 접촉불량 발생시 변색여부로 쉽게 이상유무 판단이 가능한 서모캡의 특성을 분석하였으며, 공간 등의 제약을 덜 받으면서 접속부위에 상시 설치하고 감시할 수 있는 방식인 향 캡슐과 향 검지기를 사용하여 과열을 감지하는 시스템의 원리 및 특징을 분석하였다. 마지막으로, 가융합금의 용융특성을 응용한 접촉불량 감지나사를 제작하여 단자대에 적용 및 실험하여 성능을 검증하였다. 상기 제시된 기법들을 적절히 적용된다면 MCCB 및 단자대등의 접속부의 접촉불량에 의한 전기화재 예방에 기여할 수 있을 것으로 기대된다.

시편의 열화에 따른 가스터빈 로터볼트 기계적 강도평가 (Evaluation for mechanical hardness of gas turbine rotor bolt according to deterioration of specimen)

  • 길두송;안연식;박상기
    • 동력기계공학회지
    • /
    • 제15권4호
    • /
    • pp.19-24
    • /
    • 2011
  • The operational efficiency of domestic gas turbine is about 25% and it is now in the trend of the gradual growth in spite of the severe temperature, frequent starting and shutdown according to the environmental management and the energy-efficient use. Rotor bolts of gas turbine in power plants have been the cause of defects because these gas turbines have been operated for a long time under the high pressure and temperature environment experiencing the aging change and stress concentration of the bonded part. The connection parts of the bolt revealed various failure shape and these parts were elongated under very low pressure when operated in the relaxed condition. The cause is in the lack of the metal distribution in the bottle lack area and the cap screw of the bolt is broken totally in case that the nut is fastened in most cases. Gas turbine rotor bolts are connected to the rotor wheel and these bolts caused the vibration, the bulk accident of the rotor in the event that the coupling power among these bolts was relaxed. Therefore, we would like to evaluate the soundness of the main part of the gas turbine rotor bolt through the measurement of the inner condition change along with the mechanic deterioration and temperature, stress in the gas turbine rotor material.