• 제목/요약/키워드: Screw, Animal

검색결과 51건 처리시간 0.029초

Acute limb shortening and modified pantarsal arthrodesis for the treatment of a highly comminuted distal tibial articular fracture in a dog

  • Bruno Santos;Ines Gordo;Ronan Mullins
    • Journal of Veterinary Science
    • /
    • 제24권2호
    • /
    • pp.28.1-28.7
    • /
    • 2023
  • A three-year-old female spayed Lurcher was referred for the treatment of a highly comminuted distal tibial articular fracture. Resection of the area of comminution with a transverse osteotomy of the tibial diaphysis and talar ridges was performed, followed by modified pantarsal arthrodesis and a calcaneotibial screw. The treatment resulted in 7 cm of tibial shortening, equating to a 28% reduction in the total tibial length. Radiographic union of the arthrodesis was successful. Fair use of the pelvic limb was documented long-term. Combined acute limb shortening and modified pantarsal arthrodesis resulted in an acceptable outcome and could be considered in cases of highly comminuted distal tibial fractures.

개에서 Poly-L-lactic-acid 이식물의 생분해성과 생체적합성에 관한 연구 (Study of Bio-absorbability and Bio-compatibility of Poly-L-lactic-acid Implant in Dogs)

  • 박보영;김영기;박종윤;박종만;고필옥;장홍희;이희천;이효종;연성찬
    • 한국임상수의학회지
    • /
    • 제24권2호
    • /
    • pp.182-191
    • /
    • 2007
  • Bioabsorbable devices have been utilized and experimented in many aspects of orthopaedic surgery. Depending upon their constituent polymers, these materials can be tailored to provide sufficient rigidity to allow bone healing, retain mechanical strength for certain period of time, and then eventually begin to undergo degradation. The objective of this study was to estimate extent in which Poly-L-latic acid (PLLA) implants had bioabsorbability and biocompatibility with bone and soft tissue in dogs and also to develop bioabsorbable, biocompatible materials with the appropriate strength and degradation characteristics to allow for regular clinical use for treating orthopedic problems in humans as well as animals. Eighteen dogs were used as experimental animals and were inserted two types of PLLA implants. PLLA rods were inserted into subcutaneous tissue of back or the abdomen wall. And the rods were tested for material properties including viscosity, molecular weight, melting point, melting temperature, crystallinity, flexural strength, and flexural modulus over time. PLLA screws were inserted through cortical bone into bone marrow in the femur of the dogs and stainless steel screw was inserted in the same femur. Radiographs were taken after surgery to observe locations of screw. Histological variations including cortical bone response, muscular response, bone marrow response were analyzed over the time for 62weeks. The physical properties of PLLA rods had delicate balances between mechanical, thermal and viscoelastic factors. PLLA screws did not induce any harmful effects and clinical complications on bone and soft tissue for degradation period. These results suggest that PLLA implants could be suitable for clinical use.

압출성형 공정을 이용한 돈육과 계육스낵의 제조 (Manufacture of Pork Thigh and Chicken Meat Snack by Extrusion Cooking Process)

  • 양승용;김영호;김철진;이무하;이철호
    • 한국식품과학회지
    • /
    • 제22권4호
    • /
    • pp.456-460
    • /
    • 1990
  • 단일축 압출성형기를 이용한 meat snack의 제조특성을 조사하고자 하였다. 돈육과 계육을 원료로 하여 압출기 내의 스크류 회전속도(120, 190, 260rpm)를 변수로 하고 고기함량비(고기 : 옥분=1 : 3, 1 : 1, 2 : 1, 3 : 1)에 따른 extrudate의 가공 및 압출성형 특성을 조사한 결과는 다음과 같다. 고기함량이 증가할수록 팽화율, 수분흡착력, 명도 및 황색도는 감소하였다. 팽화율은 스크류 회전속도가 증가함에 따라 커지는 경향을 나타내었으나 고기함량이 높은 2 : 1 배합비에서는 반대 현상을 나타내었다. 그러나 수분흡착력은 고기함량이 적을때에는 스크류 회전속도 190rpm에서 최대치를 나타내었으나, 고기함량이 증가함에 따라 120rpm에서 최대치를 나타내었다. 밀도에 대한 압출물의 영향은 배합비가 1 : 1, 2 : 1과 3 : 1에서는 큰 유의성은 없었으나 1 : 3과 0.1의 배합비보다는 유의적으로 높은 밀도값을 나타냈다. 한편, 고기함량이 증가할수록 적색도는 커졌으며 절단력은 배합비 1:1에서 최대치를 나타내었고 스크류 회전속도가 커질수록 절단력은 감소하는 경향을 나타내었다.

  • PDF

단측성 외고정 기구를 이용한 개의 대퇴골 신연에 있어서 골수강내 K-강선 삽입의 효과 (Effects of Intramedullary K-wire Insertion on Femoral Lengthening in Canine with Monolateral External Fixator)

  • 황재민;김영기;진희택;석성훈;이희천;고필옥;장홍희;이효종;연성찬
    • 한국임상수의학회지
    • /
    • 제23권3호
    • /
    • pp.291-299
    • /
    • 2006
  • During long bone lengthening, there are many disadvantages including axial deviation, malalignment and re-fracture which are commonly encountered inspite of its proven abilities. To study the effects of intramedullary K-wire application on the lengthening of long bone, ten skeletally mature mongrel dogs were separated into two groups(Group I, II). Right femurs of group I(5 dogs) were fixed with only monolateral external fixator after subperiosteal osteotomy. Right femurs of group II(5 dogs) were fixed with mono lateral external fixator and intramedullary K-wire after subperiosteal osteotomy. Lengthening was started at 7 days after the surgery with the rate of 0.5 mm per day for 5 weeks and the dogs were sacrificed after 15 weeks postoperatively to examine histologic differences and evaluate bone mineral density. Radiographic examination at an interval of two weeks was done to evaluate the type of callus formed and to analyze complications including instability of external skeletal fixation and axial deviation. Bone mineral density at the lengthened area and contralateral nonlengthened area were measured using quantitative computerized tomography. Histological examination of regenerated bone was performed using Masson's trichrome stain method. The radiographs demonstrated poor callus formation, higher incidence of axial deviation and screw loosening in the group I compared to the group II. The bone mineral density at the lengthened area in the group II was higher than that of the group I(P<0.05). Histological examination showed that the new bone trabeculae in the group II were greater than that of the group I. In conclusion, the combination of monolateral external fixator and intramedullary K-wire can prevent pin loosening, axial deviation and reduce healing period in dogs.

성견 구개부 골내고정원 장치에 가해진 즉시 교정력이 주위조직에 미치는 영향 (An effect of immediate orthodontic force on palatal endosseous appliance$(C-Palatal\;Plate^{TM})$ in beagle Dog)

  • 김수정;이영준;정규림
    • 대한치과교정학회지
    • /
    • 제33권2호
    • /
    • pp.91-102
    • /
    • 2003
  • 이 연구는 구개부 골내고정원 장치 C-Palatal $Plate^{TM}$에 가해진 즉시 교정력이 장치 주위 골조직 및 연조직의 치유 반응에 미치는 영향을 조직학적으로 관찰하고자 시행되었다. 4마리의 비글 성견을 대상으로 정중 구개부에 장치를 식립한 후, 교정력을 전혀 가하지 않고 8주 경과된 한 마리를 대조군으로 하고, 식립 직후부터 8주간 지속적인 교정력을 받은 한 마리, 18주간 지속적인 교정력을 받은 한 마리, 그리고 18주간 지속적인 교정력을 받은 후 장치가 제거되고 이후 4주간의 치유기간을 거친 한 마리, 총 세마리를 실험군으로 하여 동요도 검사, 방사선 사진 관찰, 그리고 조직학적 관찰을 시행한 결과 다음과 같은 결론을 얻었다. 1. 희생 후 조직괴의 측면 방사선 사진상에서, 대조군에 비하여 즉시 교정력을 받은 군에서는 플레이트의 수직적 변위가 발생하였으나 경미하였고, 동요도 검사시 모든 군에서 초기 안정성이 확인되었으며 실험기간 중 동요도의 증가는 없었다. 2. 상부 연조직의 치유상태는 실험군과 대조군 모두 병리적 변화가 관찰되지 않았다. 3. 골유착은 교정력을 가한 8주군과 18주군 모두에서 관찰되었고 18주 경과시 골유착의 분포가 더욱 증가되었다. 그러나 압박측과 긴장측간에 골유착 분포의 차이는 관찰되지 않았으며, 대조군이 실험군에 비하여 골유착에 불리한 것으로 나타났다. 4. 스크류 경부의 변연골은 대조군에서는 뚜렷한 변화가 없었던 반면, 8주군과 18주군에서는 압박측, 긴장측과 무관하게 부분적으로 변연골 침착 및 흡수가 일어났으나 경미하였다. 5. 비강으로 관통된 스크류에서, 8주군과 18주군에서는 스크류 표면을 따라 비강측으로 신생골 침착이 관찰되었으나, 대조군에서는 관찰되지 않았다. 6. 장치 제거 4주 후, 상피층은 긴밀하게 재생되었으나 결합조직은 성글고 불규칙한 배열을 보였으며, 장치를 둘러쌌던 결합조직피막이 잔존하였다. 스크류가 식립되었던 골부위에서는 왕성한 골개조가 진행되고 있었다. 즉시 교정력에 대하여 C-Palatal $Plate^{TM}$는 임상적으로 뿐만 아니라 조직학적으로도 충분한 고정원 가치를 지니는 것으로 확인되었다.

성견에 있어서 정중구개봉합선의 급속확장에 따른 상악골 인접 봉합선부위의 육안적 관찰에 관한 연구 (AN EXPERIMENTAL STUDY ON GROSS REACTIONS OF SURROUNDING MAXILLARY SUTURES TO THE WIDENING OF MIDPALATAL SUTURE IN THE DOG)

  • 이인수;유영규
    • 대한치과교정학회지
    • /
    • 제11권2호
    • /
    • pp.135-142
    • /
    • 1981
  • This study was performed to observe the gross reactions of surrounding maxillary sutures to the widening of midpalatal suture in the dog. Three healthy dog were chosen for the experiment. One animal was used as control, and two were used as experimental animals. Midpalatal suture was expanded total 7mm with screw for 10 days. The following results were obtained : 1. Midpalatal suture was expanded with the most width, in which anterior was be more expanded than the posterior, and shape was wedge form. 2. Interincisive suture was definitely expanded. 3. Internasal suture and interfrontal suture were slightly expanded. 4. Expansion of frontomaxillary suture, frontoparietal suture, frontonasal suture, zygomatico temporal suture, zygomatico frontal suture, zygomatico maxillary suture, occipito mastoid suture, occipito parietal suture, naso incisive suture, naso maxillary suture, and incisive maxillary suture were not observed.

  • PDF

압출성형 공정을 이용한 돈피스낵의 제조 (Manufacture of Pork Rind Snack by Extrusion Cooking Process)

  • 양승용;김영호;김철진;이무하;이철호
    • 한국식품과학회지
    • /
    • 제22권4호
    • /
    • pp.451-455
    • /
    • 1990
  • 본 실험은 압출성형 공정을 이용하여 돈피스낵의 제조에 필요한 가공특성을 조사하고자 실시하였다. 주원료인 돈피에 옥수수가루를 첨가하여 중량비로 1 : 2, 1 : 1, 2 : 1, 3 : 1로 혼합하고 각 혼합물의 수분함량을 5, 10, 15%되도록 건조시켰다. 이 혼합물들을 single screw extruder를 사용하여 주 스크류 회전속도를 고정하고 압출시킨 extrudate의 가공 및 압출성형 특성은 다음과 같다. 돈피와 옥분혼합물의 팽화율은 돈피:옥분=1 : 1의 배합비에서 수분함량 5%구가 가장 높았으며, 혼합물 중 돈피의 함량이 증가될수록 조밀도, 수분흡착력, 절단력과 적색도가 증가하였고, 명도와 황색도는 감소하였다. 이상의 결과에서 돈피 : 옥분의 원료혼합비율이 1 : 2와 1 : 1에서의 extrudate는 팽화된 돈피스낵을 제조하기에 만족스러운 원료배합비를 보여주었다.

  • PDF

Useful Corrosion - Potential of Magnesium Alloys as Implants

  • Kaya, A. Arslan;Kaya, R. Alper;Witte, Frank;Duygulu, Ozgur
    • Corrosion Science and Technology
    • /
    • 제7권3호
    • /
    • pp.162-167
    • /
    • 2008
  • Degradable implants have been in use for bone surgery for decades. However, degradable metal implants are one of the new research areas of biomaterials science. Magnesium has good biocompatibility due to its low toxicity, and it is a corroding, i.e. dissolvable, metal. Furthermore, magnesium is needed in human body, and naturally found in bone tissue. There have been some published reports also asserting the potential bone cell activation or bone healing effect of high magnesium ion concentrations. The classic method for achieving intertransverse process fusion involves autogenous iliac crest bone graft. Several investigations have been performed to enhance this type of autograft fusion. However, there is no research which has been undertaken to investigate the efficiency of pure magnesium particles in posterolateral spinal fusion. In this study, corrosion behavior of magnesium metal at the bone interface, the possibility of new bone cell formation and the degree of effectiveness in producing intertransverse process lumbar fusion in a sheep model have been investigated. Cortical bone screws were machined from magnesium alloy AZ31 extruded rod and implanted to hip-bones of sheep via surgery. Three months after surgery, the bone segments carrying these screws were removed from the sacrificed animals. Samples were sectioned to reveal Mg/bone interfaces and investigated using optical microscope, SEM-EDS and radiography. Optical and SEM images showed that there was a significant amount of corrosion on the magnesium screw. The elemental mapping results indicate, due to the presence of calcium and phosphorus elements, that there exists new bone formation at the interface. Furthermore, sixteen sheep were subjected to intertransverse process spinal fusions with pedicle screw fixation at various locations along their spines. Each animal was treated with 5cc autograft bone at one fusion level and 1cc magnesium+5cc autograft bone at the other. Six months after surgery, bone formation was evaluated by gross inspection and palpation, and radiological, histological, scanning electron microscopic and x-ray diffraction analyses. It may be stated that the potential for using useful corrosion of magnesium alloys in medical applications is expected to be significant.

The effect of fixation plate use on bone healing during the reconstruction of mandibular defects

  • Hong, Khang Do Gia;Kim, Seong-Gon;Park, Young-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권5호
    • /
    • pp.276-284
    • /
    • 2019
  • Objectives: This study sought to compare efficiency results between the use of a customized implant (CI) and a reconstruction plate (RP) in mandibular defect reconstruction in an animal model. Materials and Methods: Fifteen rabbits underwent surgery to create a defect in the right side of the mandible and were randomly divided into two groups. For reconstruction of the mandibular defect, the RP group (n=5) received five-hole mini-plates without bone grafting and the CI group (n=10) received fabricated CIs based on the cone-beam computed tomography (CBCT) data taken preoperatively. The CI group was further divided into two subgroups depending on the time of CBCT performance preoperatively, as follows: a six-week CI (6WCI) group (n=5) and a one-week CI (1WCI) group (n=5). Daily food intake amount (DFIA) was measured to assess the recovery rate. Radiographic images were acquired to evaluate screw quantity. CBCT and histological examination were performed in the CI subgroup after sacrifice. Results: The 1WCI group showed the highest value in peak average recovery rate and the fastest average recovery rate. In terms of reaching a 50% recovery rate, the 1WCI group required the least number of days as compared with the other groups ($2.6{\pm}1.3days$), while the RP group required the least number of days to reach an 80% recovery rate ($7.8{\pm}2.2days$). The 1WCI group showed the highest percentage of intact screws (94.3%). New bone formation was observed in the CI group during histological examination. Conclusion: Rabbits with mandibular defects treated with CI showed higher and faster recovery rates and more favorable screw status as compared with those treated with a five-hole mini-plate without bone graft.

Accuracy of Thoracolumbar Spine K-Wire Placement in Toy, Small and Medium Breed Dogs: Novice Surgeons with 3D Printed Patient-Specific Guide versus an Experienced Surgeon with Freehand Techniques

  • Hwa-Joeng Shin;Hae-Beom Lee;Yoon-Ho Roh
    • 한국임상수의학회지
    • /
    • 제39권6호
    • /
    • pp.294-301
    • /
    • 2022
  • Three-dimensional (3D) printing technique has been widely used for accurate screw and pin placement in orthopedic surgery and neurosurgery. However, there are few reports comparing the accuracy between the patient-specific guides and freehand Kirschner wire (K-wire) placement in toy, small and medium breed dogs. This study aimed to assess the accuracy of 3D printed patient-specific guides (PSGs) in pin insertion in the thoracolumbar vertebrae of toy breed dogs and compare the outcomes between novice and experienced surgeons. The experiment was conducted on the thoracolumbar vertebrae of 21 euthanized toy breed dogs (median weight, 5.95 kg). The optimal insertion angle placement was determined and patient-specific guides for K-wire insertion were designed and 3D printed using computed tomography (CT) and a 3D computer-aided design program of three vertebrae (Thoracic 12-Lumbar 1). K-wire tracts were made by experienced and novice surgeons and compared to assess the accuracy based on postoperative CT. Based on postoperative CT, in the experienced group, 61 out of 63 pins (96.8%) were fully contained inside the vertebral body and lamina, whereas two pins (3.2%) had perforated the vertebral canal (grade 3, 2-4 mm breach). However, all the pins in the novice group were fully contained. The use of 3D printed PSGs for pin insertion in the thoracolumbar region is an accurate and safe alternative to freehand screw placement by novice surgeons in toy, small and medium breed dogs. Operations with 3D printed PSGs allow novice surgeons to achieve better or similar outcomes in accurate placement of pin/screws in vertebrae.