• Title/Summary/Keyword: Screening system

Search Result 1,390, Processing Time 0.032 seconds

Building Living Lab for Acquiring Behavioral Data for Early Screening of Developmental Disorders

  • Kim, Jung-Jun;Kwon, Yong-Seop;Kim, Min-Gyu;Kim, Eun-Soo;Kim, Kyung-Ho;Sohn, Dong-Seop
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.8
    • /
    • pp.47-54
    • /
    • 2020
  • Developmental disorders are impairments of brain and/or central nervous system and refer to a disorder of brain function that affects languages, communication skills, perception, sociality and so on. In diagnosis of developmental disorders, behavioral response such as expressing emotions in proper situation is one of observable indicators that tells whether or not individual has the disorders. However, diagnosis by observation can allow subjective evaluation that leads erroneous conclusion. This research presents the technological environment and data acquisition system for AI based screening of autism disorder. The environment was built considering activities for two screening protocols, namely Autism Diagnostic Observation Schedule (ADOS) and Behavior Development Screening for Toddler (BeDevel). The activities between therapist and baby during the screening are fully recorded. The proposed software in this research was designed to support recording, monitoring and data tagging for learning AI algorithms.

A Study on the Effectiveness of Screening for Selective Breast Cancer Using Digital Mammography Centered on General Hospital (디지털 유방촬영술을 이용한 선별적 유방암 검진의 효용성에 대한 연구(2차 병원을 중심으로))

  • Kim, Hyeon-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.147-152
    • /
    • 2021
  • This study is a retrospective analysis of the results of tests at three general hospitals in Busan that perform mammography using digital mammography devices. There were 5,320 people in the study, and the results of their breast cancer screening were analyzed to verify the efficacy of breast cancer screening for digital mammography. The average age of patients who performed breast cancer screening was 57.7 years (range 30 to 87 years), and the cancer detection rate was 26, with 4.6 cases per 1,000 people. According to the cancer detection rate by risk factor in patients who conducted breast cancer screening, breast cancer was found in patients without underlying diseases more than in patients with underlying diseases. Additional ultrasound examinations show that the gastronomic rate identified is 3.6%, which is relatively very low compared to that of the Film-Screen system.

A Mixed 0-1 Linear Program for the Inspection Location Problem

  • Yum, Bong-Jin
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.10 no.1
    • /
    • pp.11-16
    • /
    • 1984
  • An economic model is developed for determining optimal locations of screening inspection stations in a multistage production system. The effect of screening inspection on the production rate is explicitly considered, and a fixed cost for maintaining an inspection station is assumed. The product is allowed to have multiple defects, each of which may be inspected at any inspection station after the defect-generating operation. The problem is formulated as a mixed 0-1 linear program which offers the advantage of versatility in handling various system constraints.

  • PDF

High Throughput Screening System for Kinetics of Brain Influx

  • Chung, Suk-Jae
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.88-89
    • /
    • 2002
  • Traditionally, kinetics of brain influx of drugs has been evaluated by a number of experimental techniques. Brain uptake index and in situ brain perfusion study have been used for the determination of the kinetics; However, these methods generally focus on the accuracy of the uptake rate into the brain rather than the speed of the determination. In addition, application of radiolabelled substrates (e.g., $_{14}$C-labelled sucrose) further impedes the wide spread acceptance of these techniques for the application of high throughput screening system. (omitted)

  • PDF

토양세척공법의 현장 적용을 통한 유류오염토양정화

  • 박인선;조종수;권오석;김영우;김석훈
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.148-151
    • /
    • 2003
  • Soil washing was applied as a supplementary step of soil remediation at a petroleum oil contaminated site. A soil washing system was designed, assembled, and operated at the site. A field screening method with PetroFlagTM was adopted at the site to find the exact boundary of contaminated area as soil excavation progressed and to verify the concentration of treated soil. The system operation showed the cleanup efficiency of 90% at the compatible cost compared to other methods.

  • PDF

Development of a Screening System for Drugs Against Human Papillomavirus-Associated Cervical Cancer: Based On E7-Rb Binding

  • Cho, Young-Sik;Cho, Cheong-Weon;Kang, Jeong-Woo;Cho, Min-Chul;Lee, Kyung-Ae;Shim, Jung-Hyun;Kwon, Our-Han;Choe, Yong-Kyung;Park, Sue-Nie;Yoon, Do-Young
    • BMB Reports
    • /
    • v.34 no.1
    • /
    • pp.80-84
    • /
    • 2001
  • The human papillomavirus E7 protein can form a specific complex with a retinoblastoma tumor suppressor gene product (p105-Rb) that results in the release of the E2F transcription factor, which is critical for the growth-deregulation and transforming properties of the viral E7 oncoprotein. In an attempt to apply interaction between the E7 oncoprotein and a target cellular protein Rb for an in vitro screening system for drugs against human papillomavirus infection, we primarily investigated the E7Rb binding through a pull down assay and enzyme-linked immunosorbent assay. The pull down assay showed that both glutathione S-transferase-tagged E7 and His-tagged E7 immobilized on resins specifically produced complexes with bacterially expressed Rb in a dose-dependent manner, as determined by immunoblot analyses. This result coincided with that of an enzyme-linked immunosorbent assay, which is a useful system for the mass screening of potential drugs. Taken together, this screening system (based on the interaction between E7 and Rb) can be a promising system in the development of drugs against cervical cancers caused by human papillomavirus infection.

  • PDF

Development of ELISA System for Screening of Specific Binding Inhibitors for Src Homology (SH)2 Domain and Phosphotyrosine Interactions

  • Lee, Sang-Seop;Lee, Kyung-Im;Yoo, Ji-Yun;Jeong, Moon-Jin;Park, Young-Mee;Kwon, Byoung-Mog;Bae, Yun-Soo;Han, Mi-Young
    • BMB Reports
    • /
    • v.34 no.6
    • /
    • pp.537-543
    • /
    • 2001
  • In the present study, an in vitro ELISA system to assess the interaction between Src homology (SH)2 domains and phosphotyrosine that contain peptides was established using purified GST-conjugated SH2 proteins and synthetic biotinylated phosphotyrosine that contain oligopeptides. The SH2 domains bound the relevant phosphopeptides that were immobilized in the streptavidin-coated microtiter plate in a highly specific and dose-dependent manner. The epidermal growth factor receptor (EGFR)-, T antigen (T Ag)-, and platelet-derived growth factor receptor (PDGFR)-derived phosphopeptides interacted with the growth factor receptor binding protein (Grb)2/SH2, Lck/SH2, and phosphatidyl inositol 3-kinase (PI3K) p85/SH2, respectively. No cross-reactions were observed. Competitive inhibition experiments showed that a short phosphopeptide of only four amino acids was long enough to determine the binding specificity. Optimal concentrations of the GST-SH2 fusion protein and phosphopeptide in this new ELISA system for screening the binding blockers were chosen at 2nM and 500nM, respectively. When two candidate compounds were tested in our ELISA system, they specifically inhibited the Lck/SH2 and/or p85/SH2 binding to the relevant phosphopeptides. Our results indicate that this ELISA system could be used as an easy screening method for the discovery of specific binding blockers of protein-protein interactions via SH2 domains.

  • PDF

Evaluation of a New Episomal Vector Based on the GAP Promoter for Structural Genomics in Pichia pastoris

  • Hong In-Pyo;Anderson Stephen;Choi Shin-Geon
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.9
    • /
    • pp.1362-1368
    • /
    • 2006
  • A new constitutive episomal expression vector, pGAPZ-E, was constructed and used for initial screening of eukaryotic target gene expression in Pichia pastoris. Two reporter genes such as beta-galactosidase gene and GFPuv gene were overexpressed in P. pastoris. The expression level of the episomal pGAPZ-E strain was higher than that of the integrated form when the beta-galactosidase gene was used as the reporter gene in P. pastoris X33. The avoiding of both the integration procedure and an induction step simplified the overall screening process for eukaryotic target gene expression in P. pastoris. Nine human protein targets from the Core 50, family of Northeast Structural Genomics Consortium (http://www.nesg.org), which were intractable when expressed in E. coli, were subjected to rapid screening for soluble expression in P. pastoris. HR547, HR919, and HR1697 human proteins, which had previously been found to express poorly or to be insoluble in E. coli, expressed in soluble form in P. pastoris. Therefore, the new episomal GAP promoter vector provides a convenient and alternative system for high-throughput screening of eukaryotic protein expression in P. pastoris.

Improving Imaging Quality Assessment of Cabinet X-Ray Security Systems (캐비닛 엑스선 검색장비 이미지품질평가 고도화 방안 연구)

  • Yoon, Yeon Ah;Jung, Jin Hyeong;Kim, Yong Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.49 no.1
    • /
    • pp.47-60
    • /
    • 2021
  • Purpose: This study proposes methods and procedures for evaluating imaging security systems quality of cabinet x-ray screening system to enhance performance certification technology. Also, conducted a comparative analysis of the literature of test-kit for imaging security quality evaluation. Methods: Comparative analysis of the test-kits and related documents for image quality assessment of cabinet x-ray screening equipment. This allows assessment items were selected and the methods for each assessment item were proposed. In addition, the configuration method of the assessment team was established by applying the technology readiness assessment(TRA). Results: Four of the assessment items were selected when estimate image quality by a comparative analysis of literature. For each assessment item, the evaluation method and minimum level of availability were determined. Finally, this paper proposes an imaging quality assessment of cabinet X-ray imaging security systems. Conclusion: Development of imaging security systems evaluation procedures for cabinet X-ray screening systems can be help improve performance certification of aviation security equipment.