• Title/Summary/Keyword: Screening Limits

Search Result 72, Processing Time 0.023 seconds

Development of Rapid, Safe Analytical Techniques of Aflatoxins and Their Current Regulation (Aflacxin에 대한 최신 분석법과 규제동향)

  • 정덕화
    • Journal of Food Hygiene and Safety
    • /
    • v.5 no.3
    • /
    • pp.131-138
    • /
    • 1990
  • Aflatoxins is a chemically diverse group of toxic secondary metabolites that are produced by fungi and often occur in agricultural commodities. Because of their wide range of toxic effects, Aflatoxins cause severe economic losses to farmers and livestock producers and pose a health to human consuming contaminated foods. Long term prospects for biotechnological control of Aflatoxins require elucidation of the specific steps and regulation of their biosynthetic pathways . Aflatoxin determinations can be approached many ways. It is essential to safely handle all experimental materials associated with aflatoxin analysis or aflatoxigenic fungi Visual screening of suspect samples, base on the presence of conidial head of the aspergillus flavus group, and screening samples for the presence of bright greenish yellow flourescence are not chemical tests and such screening techniques may allow aflactoxin contaminated lots into commerce. Microcolumn screening procedures should always be used in conjunction with a quantitative method. Several thin layer chromatography(TLC) and high performance liquid chromatography(HPLC) methods are suitable for quantitation and are in general use. Immunochemical Methods such as the ELISA or affinity column chromatography methods are being rapidly developed. The chemical and immunochemical methods can be reliable if care is taken, using suitable controls and personnel that are well trained . All analytical laboratories should stress safety and include suitable analytical validation procedure. Especially a worldwide enquiry was undertaken in recent to obtain up-to-date information about aflatoxin legislation in as many countries of the world as possible. The information concerns aflatoxin in foodstuffs. aflatoxin MI in dairy products, aflatoxins in animal feedstuffs. Limits and regulations for aflatoxin have been expended in recent with more countries having legislation on subject, more products, and more aflatoxins covered by this legislation.

  • PDF

Isolated 3-Methylcrotonyl CoA Carboxylase Deficiency Detected by Newborn Screening Program Using Tandem Mass Spectrometry (탠덤매스 신생아 스크리닝 검사로 발견된 Isolated 3-Methylcrotonyl CoA Carboxylase 결핍증 1례)

  • Kwak, Ju Young;Park, Jun Young;Nam, Kyung A;Son, Sang Hi;Seo, Son Sang
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.5
    • /
    • pp.561-564
    • /
    • 2005
  • Isolated deficiency of 3-methylcrotonyl CoA carboxylase is a rare disorder of the catabolic pathway for leucine and many patients have mild symptoms or no symptom. However, the introduction of tandem mass spectrometry in newborn screening has revealed an unexpectedly high incidence of this disorder. We report an asymptomatic premature infant with isolated 3-methylcrotonyl CoA carboxylase deficiency detected by newborn screening program using tandem mass spectrometry. She was born at preterm, 36 weeks of gestation and her birth weight was 1,912 gm. She was delivered by Cesarian section due to maternal preeclampsia and oligohydramnios. An elevation of 3-hydroxyisovalerylcarnitine in a blood sample obtained at Seven days was detected by tandem mass screening. Massively elevated excretion of 3-hydroxyisovalerate and 3-methylcrotonylglycine was detected in the urine collected at 15 days. L-carnitine(100 mg/kg/day) was administrated orally to correct sencondary carnitine deficiency. Carnitine is conjugated with metabolites, to decrease the potential toxic effects. She is asymptomatic to date, and her growth and development are within normal limits.

Rapid Screening of Salmonella spp. Using PBM BioSignTM Salmonella Test and Evaluation of the PBMS Test

  • Lim, J.Y.;Kwon, N.H.;Kim, J.M.;Jung, W.K.;Park, K.T.;Hong, S.K.;Park, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.12
    • /
    • pp.1746-1750
    • /
    • 2004
  • The PBM ${BioSign}^{TM}$ Salmonella (PBMS) test kit based on an mmunochromatographic method was evaluated for the screening of Salmonella spp. in pure cultures, and 80, 15, and 10 artificially and naturally contaminated, and negative controlled food samples, respectively. The PBMS test involves presumptive qualitative procedures, detecting the presence of Salmonella spp. in foods within 26 h total testing period and allowing the user to release negative products 70 h earlier than the conventional methods. The PBMS test using Buffered Peptone Water and Rappaport-Vassiliadis broth was evaluated for 10 different food types for various Salmonella spp. It showed detection limits of 1 to 25 colony forming units (CFU)/25 g. No cross-reaction was observed, particularly to other gramnegative bacteria. These results indicate the PBMS test is a rapid and inexpensive procedure for the screening of Salmonella spp. present at low concentrations (1 to 25 CFU/25 g) in foods.

A study on the ATC(Available Transfer Capabilily) calculation using an Energy Function Method (에너지함수법을 이용한 가용송전용량(ATC) 계산에 관한 연구)

  • Kim, Jae-Hyeon;Jeong, Sung-Won;Kim, Yong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.94-100
    • /
    • 2008
  • Available transfer capability(ATC) quantifies the viable increase in real power transfer from one point to another in a power system. ATC calculation has predominantly focussed on steady-state viability. But ATC assessment with transient stability constraints has a dominant part in overall ATC calculation. ATC assessment requires a reputation of (n-1) security assessment with constraints of thermal limits, voltage stability and dynamic stability. An estimation of determinant contingency screening method is used for computing eigenvalue of Jacobian matrix. This paper proposed a methods to ATC calculation using energy function. Constraints is used thermal limits, voltage stability and transient stability.

Screening of Nitrosamine Impurities in Sartan Pharmaceuticals by GC-MS/MS

  • Chang, Shu-Han;Ho, Hui-Yu;Zang, Chi-Zong;Hsu, Ya-Hui;Lin, Mei-Chih;Tseng, Su-Hsiang;Wang, Der-Yuan
    • Mass Spectrometry Letters
    • /
    • v.12 no.2
    • /
    • pp.31-40
    • /
    • 2021
  • Probable human carcinogenic compounds nitrosamines, have been detected as by-product impurities in sartan pharmaceuticals in recent years which has drawn worries for medication safety. To provide a sensitive and effective method for the quality control of sartan pharmaceuticals, this study established a feasible gas chromatography-tandem mass spectrometry (GC-MS/MS) method for simultaneous determination of 13 nitrosamines. The target analytes were separated on a DB-WAX Ultra Inert column (30 m × 0.25 mm; i.d., 0.25 ㎛) and were then subjected to electron impact ionization in multiple reaction monitoring mode. The established method was validated and further employed to analyze authentic samples. Limits of detection (LODs) and limits of quantification (LOQs) of the 13 nitrosamines were 15-250 ng/g and 50-250 ng/g, respectively, which also exhibited intra-day and inter-day accuracies of 91.4-104.8%, thereby satisfying validation criteria. Five nitrosamines, viz., N-nitrosodiethylamine, N-nitrosodimethylamine, N-nitrosodiphenylamine, N-nitrosomorpholine, and N-nitrosopiperidine were detected at concentrations above their LODs in 68 positive samples out of 594 authentic samples from seven sartans.

Security Constrained Optimal Power Flow by Hybrid Algorithms (하이브리드 알고리즘을 응용하여 안전도제약을 만족시키는 최적전력조류)

  • Kim, Gyu-Ho;Lee, Sang-Bong;Lee, Jae-Gyu;Yu, Seok-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.6
    • /
    • pp.305-311
    • /
    • 2000
  • This paper presents a hybrid algorithm for solving optimal power flow(OPF) in order to enhance a systems capability to cope with outages, which is based on combined application of evolutionary computation and local search method. The efficient algorithm combining main advantages of two methods is as follows : Firstly, evolutionary computation is used to perform global exploitation among a population. This gives a good initial point of conventional method. Then, local methods are used to perform local exploitation. The hybrid approach often outperforms either method operating alone and reduces the total computation time. The objective function of the security constrained OPF is the minimization of generation fuel costs and real power losses. The resulting optimal operating point has to be feasible after outages such as any single line outage(respect of voltage magnitude, reactive power generation and power flow limits). In OPF considering security, the outages are selected by contingency ranking method(contingency screening model). The OPF considering security, the outages are selected by contingency ranking method(contingency screening model). The method proposed is applied to IEEE 30 buses system to show its effectiveness.

  • PDF

Clinical Experience and Sensitivity of the AutoPap 300 QC System in Cervicovaginal Cytology (자궁경부세포진에 있어서 AutoPap 300 QC System의 임상경험과 민감도 검사)

  • Hong, Sung-Ran;Park, Jong-Sook;Jang, Hoi-Sook;Kim, Yee-Jeong;Kim, Hy-Sook;Park, Chong-Taik;Park, In-Sou
    • The Korean Journal of Cytopathology
    • /
    • v.9 no.1
    • /
    • pp.37-44
    • /
    • 1998
  • OBJECTIVE: False negatives of cervical smears due to screening errors pose a significant and persistent problem. AutoPap 300 QC System, an automated screening device, is designed to rescreen conventionally prepared Pap smears initially screened by cytotechnologists as normal. Clinical experience and sensitivity of the AutoPap 300 QC System were assessed and compared with current 10% random qualify control technique. MATERIALS AND METHODS: In clinical practice, a total of 18,592 "within normal limits" or "benign cellular changes" cases classified by The Bethesda System were rescreened by the Autopap System. In study for sensitivity of The AutoPap System to detect false negatives, a total of 1,680 "within normal limits" or "benign cellular changes" cases were rescreened both manually and by the AutoPap System. The sensitivity of the AutoPap System to these false negatives was assessed at 10% review rate to compare 10% random manual rescreen. RESULTS: In clinical practice, 38 false negatives were identified by the AutoPap System and we had achieved 0.2% reduction in the false negative rate of screening error. In study for sensitivity, 37 false negatives were identified by manual rescreening, and 23 cases(62.2%) of the abnormal squamous cytology were detected by the AutoPap System at 10% review rate. CONCLUSONS: The AutoPap 300 QC System is a sensitive automated rescreening device that can detect potential false negatives prior to reporting and can reduce false negative rates in the laboratory. The device is confirmed to be about eight times superior to the 10% random rescreen in detecting false negatives.

  • PDF

The Aurora Kinase Inhibitor CYC116 Promotes the Maturation of Cardiomyocytes Derived from Human Pluripotent Stem Cells

  • Sijia, Ji;Wanzhi, Tu;Chenwen, Huang;Ziyang, Chen;Xinyue, Ren;Bingqing, He;Xiaoyan, Ding;Yuelei, Chen;Xin, Xie
    • Molecules and Cells
    • /
    • v.45 no.12
    • /
    • pp.923-934
    • /
    • 2022
  • Human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs) have great potential in applications such as regenerative medicine, cardiac disease modeling, and in vitro drug evaluation. However, hPSC-CMs are immature, which limits their applications. During development, the maturation of CMs is accompanied by a decline in their proliferative capacity. This phenomenon suggests that regulating the cell cycle may facilitate the maturation of hPSC-CMs. Aurora kinases are essential kinases that regulate the cell cycle, the role of which is not well studied in hPSC-CM maturation. Here, we demonstrate that CYC116, an inhibitor of Aurora kinases, significantly promotes the maturation of CMs derived from both human embryonic stem cells (H1 and H9) and iPSCs (induced PSCs) (UC013), resulting in increased expression of genes related to cardiomyocyte function, better organization of the sarcomere, increased sarcomere length, increased number of mitochondria, and enhanced physiological function of the cells. In addition, a number of other Aurora kinase inhibitors have also been found to promote the maturation of hPSC-CMs. Our data suggest that blocking aurora kinase activity and regulating cell cycle progression may promote the maturation of hPSC-CMs.

A Study on the Case Analysis by Type of the Cadastral Surveying Screening (지적측량 적부심사 유형별 사례분석에 관한 연구)

  • OH, Yi-Kyun
    • Journal of Cadastre & Land InformatiX
    • /
    • v.52 no.2
    • /
    • pp.137-152
    • /
    • 2022
  • The cadastral boundary points which cadastral surveyor presented on the ground by conducting cadastral surveying represents the limits of land ownership and give binding force and determination power. However the land disputes have increased these days mainly due to cadastral registration errors, surveying errors and land owners recognition error. In these cases, the cadastral survey interests try to find solution by either a administrative procedures by appealing civil complaint or border determination litigation through court. The neighboring residents and related organization have difficulties in resolving the civil complaints. In this study cadastral surveying and cadastral boundary determination process has been reviewed and the results of cadastral surveying screening by Central Cadastre Committee from 2016 to 2021 have been classified. The outcomes of this research will be used for cadastral surveying and contribute for reducing land disputes and improve reliablity of cadastral surveying.

A Study on the NOx Removal in Multiple Plasma/Catalyst Combined Reactor (플라즈마/촉매 복합 다단 반응기를 이용한 NOx 저감)

  • 문승현;전상구
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.83-90
    • /
    • 2004
  • Plasma/catalyst combined reactor was designed to overcome the limits of plasma and catalyst technologies. Optimum reductant and catalyst was selected from screening test. Experiments about the concentrations of reactant and $H_2O$ and the effect of temperature were carried out. Hydrocarbons with double bond such as propylene and so on were more reactive than any other reductants in plasma/catalyst condition. Photocatalyst, especially hombikat >$TiO_2$ with the largest surface area among the catalysts tested, showed the highest DeNOx efficiency in plasma/catalyst reaction. As the concentration of $H_2O$ increased, the removal of NO was enhanced. The increased concentration of >$O_2$ promoted the reaction of NO which was oxidized to$NO_2$.