• Title/Summary/Keyword: Screen model

Search Result 533, Processing Time 0.028 seconds

국가연구개발사업 중간평가방법 연구-선도기술개발사업에의 적용사례-

  • 임윤철;이철원
    • Journal of Technology Innovation
    • /
    • v.5 no.2
    • /
    • pp.126-154
    • /
    • 1997
  • This paper addresses a methodology for monitoring the first phase('92-94') progress and its implication fo Highly Advanced National R&D Projects (HAN or G7 project) in Korea. The authors suggest a three-stage life cycle model for the management of national R&D program; planning stage, implementing & monitoring stage, and evaluating & harvesting stage. The interim evaluation, the main focuses of this paper, is one of the key issues for the effective management of national R&D program at the implementing & monitoring stage. The conceptual framework of the interim evaluation was developed both through reviewing related literature and considering the characteristics of the HAN program. A stepwise procedure of interim evaluation was introduced: 'initial screen' and 'detailed examination'. At initial screen all 11 projects were reviewed in terms of both their relevance and performance in order to decide whether further detailed scrutiny is needed or not. If there exist critical problems on the relevance or on the intermediate progress of each project, it is to be under further detailed examination. Evaluation was initiated by the G7 Planning and Evaluation Committee, which was established for advising, directing, and monitoring the HAN Projects, with the help of large number of experts from industries, universities, and research institutes. The monitoring results were reported to the related ministries and project coordinating agencies, and reflected in the second phase.

  • PDF

Introduction of a VOD Mobile App for Promoting VOD Service of a Domestic Digital Cable Broadcasting (국내 디지털케이블 방송사의 VOD 서비스 활성화를 위한 VOD 모바일 앱 개발 사례)

  • Ko, Kwangil
    • Convergence Security Journal
    • /
    • v.14 no.2
    • /
    • pp.3-9
    • /
    • 2014
  • As the subscribers of the digital cable and IPTV broadcasting are increasing, the VOD service has established a solid foothold as a profit model of the broadcasting industries. And what's more, the VOD service is emerging as a key application of the N-screen technologies. In the circumstance, broadcasting companies are trying to provide mobile services to improve the satisfaction of their VOD services usage. The paper introduces a VOD mobile app (of a domestic digital cable broadcasting), which includes the functions of promoting the VOD programs printed on a VOD guide book, directly transmitting the information (e.g., book-marking, remote-control signals) generated by the VOD mobile app to a set-top box, and watching the video contents stored in the mobile device on TV.

Introduction of Mobile Supporting Functionalities for Promoting the VOD Service of a Digital Cable Broadcasting (디지털케이블방송사의 VOD 서비스 활성화를 위한 모바일 지원 기능 개발 사례)

  • Ko, Kwangil
    • Journal of Digital Contents Society
    • /
    • v.15 no.3
    • /
    • pp.339-346
    • /
    • 2014
  • VOD Service, which has established a solid foothold as a profit model of digital broadcasting companies, is emerging as a key application of the N-screen technologies and services. In the circumstance, broadcasting companies are trying to promoting their VOD services by providing mobile services for improving the VOD service usability. The paper introduces a VOD mobile app (of a domestic digital cable broadcasting), which includes the functions of promoting the VOD programs and events printed on a VOD guide book, directly transmitting the information (e.g., book-marking and remote-control signals) to a set-top box, and watching the video contents stored in the mobile device on TV.

A Case Study for Reasonable Emission Regulation of Odor Exhaust Stack (악취 배출구의 합리적인 배출규제를 위한 사례연구)

  • Park, Jeong-Ho;Lee, Hyung-Chun
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.155-161
    • /
    • 2016
  • In this study, field experiment, odor simulator, and dispersion modeling were used to evaluate the odor impact from J sewage sludge treatment facility. The height and flow rate of exhaust stack at this facility were 22.3 m and $100Nm^3/min$. The mean odor concentrations of the wet scrubber inlet and exhaust stack were $267{\pm}160$ and $93{\pm}44OU/m^3$, respectively. The odor removal efficiency of wet scrubber showed 65%. The odor simulator is used for the regulated standard calculation of the exhaust pipe(stack). Resulting odor emission rate(OER) by odor simulator was $2.4{\times}10^6(24,000OU/m^3)$. The forecasting result by Screen3 modeling showed that odor exhaust concentration up to $30,000OU/m^3$ was't exceeded maximum allowable emission level on site boundary($15OU/m^3$).

Isolation and Identification of Serratia sp. Producing Cephalosporin C Amidase (Cephalosporin C Amidase를 생산하는 Serratia sp. 균주의 분리와 동정)

  • 신중철;강용호;김영수
    • Microbiology and Biotechnology Letters
    • /
    • v.27 no.2
    • /
    • pp.96-101
    • /
    • 1999
  • Various side-chains are introduced to the 7-amino position of 7-aminocepha-losporanic acid (7-ACA) to make semi-synthetic cephalosporin antibiotics. In order to convert cephalosporin C (CPC) to 7-ACA, two enzymatic reactions are generally imployed. Glutary1-7-aminocephalosporanic acid (Gl-7-ACA) acylase is involved in the second step where the reaction intermediate, Gl-7-ACa is converted into 7-ACA. It was recently reported that CPC amidase can convert CPC directly into 7-ACA in a single enzymatic reaction. A study was undertaken to screen microorganisms conferring enzyme activity to convert Gl-7-ACA or CPC into 7-ACA by one or two enzymatic reactions. In order to screen the microorganisms rapidly, a non-$\beta$-lactam model compund, glutaryl-$\rho$-nitroanilide, was utilized in an early stage, thereafter the selected microorganisms were examined with real substrates. One microorganism exhibiting both Gl-7-ACA acylase and CPC amidase activities was obtained by the colorimetry method and HPLC assay, and was identified as a strain of Serratia species, designated as Serratia sp. N14.4. The optimal fermentation conditions for Serratia sp. N14.4 was pH9.0 and 3$0^{\circ}C$.

  • PDF

Fire Risk Assessment for Subway Station According to Supply and Exhaust Conditions (지하철 승강장 급배기 조건에 따른 화재 위험성 평가)

  • Kim, Ha-Young;Rie, Dong-Ho;Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.29-34
    • /
    • 2008
  • In this research, to establish the emission for the people who are clearing out, through the numerical analysis using the CFD model, the dangerousness has been investigated in the various emission conditions in a station platform. As a result of research, it is found out that the temperature variation falls between 65.37% and 74.97% to compare without installation of platform screen doors. In the addition, with the supply mode or push-pull mode, the warm current is generated in the platform so the temperature and the layer of smoke are stirred up and felled off. It will make the dangerousness when the people escape. Therefore, when the capacity of emission and the space of platform is set up, the design regards the properties of the fire emission.

Computational Fluid Dynamics Simulation of Flow Pattern Change in the Andong-Imha Reservoir Connecting Tunnel Due to Fish Exclusion Screens (어류 차단 스크린 설치에 따른 안동-임하호 연결터널 내 흐름변화에 대한 전산유체동역학 수치모의)

  • An, Sangdo
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.477-485
    • /
    • 2014
  • Imha Reservoir is connected to Andong Reservoir via a diversion tunnel allowing water to pass between. The diversion tunnel is equipped with screens to exclude exotic largemouth bass due to their predatory impacts on prey assemblages resulting in a degradation of species richness of local fish fauna and extinction of local fish populations in Korea. Flow pattern changes resulting from the fish screens and trash racks were investigated using a computational fluid dynamics (CFD) model. Numerical simulations showed that the decrease in the discharge capacity of the tunnel is approximately 8.6% and the headloss coefficient for fish screen at Andong intake tower was determined to be 1.5. In order not to allow the small fishes enough to pass through the wire openings enter into Imha Reservoir through tunnel, the velocity in the tunnel should be greater than 1.48 m/s which is a critical ascending velocity of the bass. This study suggests that it can keep the velocity higher enough to exclude largemouth bass when a gate opens with the condition of 1.0m difference in water stage between two reservoirs.

Impact conditions of motorcyclists on road protection systems by numerical simulation

  • Peng, Li;Brizard, Denis;Massenzio, Michel
    • Structural Engineering and Mechanics
    • /
    • v.82 no.2
    • /
    • pp.233-244
    • /
    • 2022
  • Following a loss of control, the impact against a road barrier in a turn predominates among the most severe motorcyclist accidents. These road restraint devices can be equipped with a motorcycle screen, the function of which is to restrain the rider and minimize the consequences of the impact in terms of the severity of injuries. The performance of these screens is evaluated by the European normative procedure EN1317-8, which specifies the test conditions, based on one or two configurations. In practice, however, these impact conditions are very diverse, difficult to extrapolate from accident analysis and therefore poorly investigated. This study is interested in improving knowledge of these impact conditions in terms of impact speed, impact angle and particularly position of the rider. A finite element model has been developed to simulate the dynamic behavior of the rider from loss of control to impact on the screen. Statistical analysis of the results shows a high variability of the impact conditions, in particular with regard to the direction of turn (to the right or to the left). Some improvements are suggested in order to overcome the limitations inherent in standard procedures.

Optimum Failure Prediction Model of Steam Generator Tube with Two Parallel Axial Through-Wall Cracks (두개의 평행한 축방향 관통균열이 존재하는 증기발생기 세관의 최적 파손예측모델)

  • Lee, Jin-Ho;Song, Myung-Ho;Choi, Young-Hwan;Kim, Nak-Cheol;Moon, Seong-In;Kim, Young-Jin
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1186-1191
    • /
    • 2003
  • The 40% of wall criterion, which is generally used for the plugging of steam generator tubes, may be applied only to a single crack. In the previous study, a total of 9 failure models were introduced to estimate the local failure of the ligament between cracks and the optimum coalescence model of multiple collinear cracks was determined among these models. It is, however, known that parallel axial cracks are more frequently detected during an in-service inspection than collinear axial cracks. The objective of this study is to determine the plastic collapse model which can be applied to the steam generator tube containing two parallel axial through-wall cracks. Nine previously proposed local failure models were selected as the candidates. Subsequently interaction effects between two adjacent cracks were evaluated to screen them. Plastic collapse tests for the plate with two parallel through-wall cracks and finite element analyses were performed for the determination of the optimum plastic collapse model. By comparing the test results with the prediction results obtained from the candidate models, a plastic zone contact model was selected as an optimum model.

  • PDF

Optimum Global Failure Prediction Model of Inconel 600 Thin Plate with Two Parallel Through-Wall Cracks

  • Moon Seong In;Kim Young Jin;Lee Jin Ho;Song Myung Ho;Choi Young Hwan
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.316-326
    • /
    • 2004
  • The $40\%$ of wall criterion, which is generally used for the plugging of steam generator tubes, is applied only to a single crack. In a previous study, a total number of 9 failure models were proposed to estimate the local failure of the ligament between cracks, and the optimum coalescence model of multiple collinear cracks was determined among these models. It is, however known that parallel axial cracks are more frequently detected than collinear axial cracks during an in-service inspection. The objective of this study is to determine the plastic collapse model that can be applied to steam generator tubes containing two parallel axial through-wall cracks. Three previously proposed local failure models were selected as the candidates. Subsequently, the interaction effects between two adjacent cracks were evaluated to screen them. Plastic collapse tests for the plate with two parallel through-wall cracks and finite element analyses were performed to determine the optimum plastic collapse model. By comparing the test results with the prediction results obtained from the candidate models, a COD base model was selected as an optimum model.