• Title/Summary/Keyword: Screen door

Search Result 132, Processing Time 0.032 seconds

A study on the optimal ventilation and smoke exhaust systems in case of fire in subway stations installed with PSD (PSD가 설치된 지하철 역사 내 화재 시 최적 배연시스템 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.527-539
    • /
    • 2018
  • The subway used by many passengers is required to maintain a safe and comfortable environment and PSD (Platform Screen Door) must be installed in the platform after reinforcing the standard in 2003. In the previous research, in case of subway fire to control it, it is necessary to design the optimal ventilation and smoke exhaust system according to equipment capacity of the smoke exhaust system. Therefore, in this study, based on the results of previous research, three-dimensional numerical analysis was performed for the CO gas and smoke flow by the subway ventilation system in case of platform fire. As a result of this study, it was found that in case of emergency, if only the upper-level smoke exhaust system is activated, the risk of evacuation is high due to CO gas (653.8 ppm) and smoke concentration ($768.4mg/m^3$). And when all the smoke exhaust systems are activated and only the fire side PSD is opened, CO gas (36.0 ppm) and smoke concentration ($26.2mg/m^3$) are detected and the propagation range of smoke flow was reduced. When all the smoke exhaust systems are activated and only the fire side PSD is closed, it was analyzed as the most effective ventilation mode in the evacuation environment due to the absence of smoke-recirculation.

Analysis of Cooling Air Current and Efficiency of Air Conditioning in the Underground Subway Station with Screen-Door Opening and Closing (도시철도 역사 스크린 도어 개폐에 따른 냉방 기류 해석 및 효율 비교 분석)

  • Jang, Yong-Jun;Ryu, Ji-Min;Jung, Ho-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.5
    • /
    • pp.328-335
    • /
    • 2014
  • Numerical prediction methods were applied to investigate the turbulent air currents and air-conditioning efficiency in an underground subway station, and the results compared to experimental data. The Shin-gumho Station($8^{th}$ floor underground and 43.6m in depth) in Seoul was selected for the analysis. The entire station was covered for simulation and the ventilation mode was ordinary. The ventilation diffusers were modeled as 95 square shapes of $0.6m{\times}0.6m$ in the lobby and as 222 square shapes in the platform. Cooling air of $47,316m^3/h$ was supplied and the returned air of $33,980m^3/h$ is exhausted in the lobby and the cooling air of $33,968m^3/h$ is supplied and the returned air of $76,190m^3/h$ was exhausted in the platform which is the same as the experimental data. The cases of the screen-door-closed and open were respectively investigated. A total of 7.5million grids were generated and the whole domain divided into 22 blocks for MPI efficiency of calculation. Large eddy simulation (LES) was applied to solve the momentum and energy equation.

Kinematic Envelope Analysis of the Urban Transit EMU based on PSD Installation (PSD 설치에 따른 도시철도차량의 동적 거동 분석)

  • Chung, Jong-Duk;Ohn, Jung-Ghun;Pyun, Jang-Sik;Park, Jang-Gon;Lee, Jong-Woo
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.6
    • /
    • pp.447-453
    • /
    • 2013
  • Since PSDs(Platform Screen Doors) are set up at many subway stations, their design related to safety has become gradually important. In particular, the interference check with a running railway vehicle is the most important of performance indices because the collision between PSDs and vehicles can be dangerous for passengers in the car and on platforms. When the train comes into a station with a curvature, the passenger car has a large translational and rotational motion and the displacement is enough for coming in contact with PSD. The performance is affected by many design parameters such as rail design parameters and vehicle velocity. This study proposes dynamic analysis models for railway vehicles and rails. Some parameters were also considered in the models to determine their influence on the performance.

Efficiency Evaluation of Operating Railroad with Subway Cabin Air Purifier (도시철도 객실 공기정화장치(SCAP)의 운행차량 효율평가)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;Cho, Goan-Hyun;NamGoong, Seok;Lee, Joo-Yeol;Kim, Tae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1303-1308
    • /
    • 2011
  • In the modern society various types of transportation mode are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day. Because of interests on the indoor air quality (IAQ) of underground public facilities, concerns on IAQ of subway system by many people are increasing. There are several approach to improve IAQ of subway station, such as installing platform screen door (PSD), frequent tunnel washing-out, and etc, however there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin since the problem of maintenance cost. Therefore, the ultimate object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. The subway cabin air purifier (SCAP) was developed for removing particulate matters and gases pollutants inside a cabin. The whole system was designed and the roll-filter device was manufactured based on numerical prediction results. It is expected that SCAP could reduce indoor air pollutants in the subway cabin practically and it can be applied to other part of transportation vehicles.

  • PDF

An Analysis of the Customer Demand for Digital Convergence of the Furniture in the Living Space of Ubiquitous Home (유비쿼터스 주택 거실 가구의 디지털 컨버젼스화를 위한 소비자 요구 분석)

  • Ryu, Hye-Ji
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.8 no.2
    • /
    • pp.29-37
    • /
    • 2008
  • The purpose of this study was to analyze the customer demand for design development of digital convergence furniture in the living space of the ubiquitous home. This study used the individual survey method and was collected from July 1 to 20, 2008. The frequency and percentage were used for data analysis by SPSS window's 12. The results of the study were as follows: The first, a lot of survey targets were 30-40 years old, university graduates, over 50,000,000 won in annual income and 30-40 pyung in house size. The second, what types of activity were carried out in the living room were acquisition of knowledge>entertainment activity>communication activity>household chores. The third, what types of furniture were used in the living room were A/V furniture>table>sofa>computer table>bookself. The forth, customers preferred to picture telephone service in sociality, home-theater service in entertainment and home appliances remote control service in information service. The fifth, the digital functions which can integrate with the living roon furniture, in the item for A/V furniture, was front door control function which recognizes visitors with the screen. In the item for table was function to search internet and for sofa was self purification function. Finally, the digital convergence furniture is not only for one activity but also for various types of activities that can comprehensively function to materialize the concept of comfortable furniture in the living space.

  • PDF

Visualization of Smoke Flow in the Subway Fire (지하철 화재발생시 역사내 화재연기 거동 가시화 연구)

  • Choi Chang Jin;Jung Hae Gon;Kim Sang Moon;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.64-68
    • /
    • 2005
  • In this study, the smoke flows of the inner subway station were visualized through a numerical analysis and visualization experiment in the subway fire. A transparent acrylic model was designed and installed as 1:25th scale-down as the actual subway station by using geometrical similarity The properties of subway fire were reconstructed according to Densimetric Froude Similarity. The 47 to 53 ratio of the mixed air and Helium was inputted in the inner acrylic model to describe 1MW fire intensity with reference to the experiment paper. For the same time, the fire smoke from a smoke generator was inputted in the inner acrylic model with the mixture. At this time, the buoyancy effect of Helium gas went up the smoke to the acrylic model. When the sheet beam of Ar-lon laser was given out to the top and stair of subway model, the digital camcorder took the images of the scattered cluster of smoke particles when applying the smoke management system and PSD.

  • PDF

Experimental Investigation about Optimum Smoke Extraction System for Underground Station (축소 모형 실험을 통한 정거장내 적정 배연방식에 관한 연구)

  • Lee, Ho-Keun;Kim, Myoung-Woo;Lee, Phill-Young;Kim, Nam-Suk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.53-59
    • /
    • 2008
  • If fire is occurred in the subway, the train must be moved to the closest station and make passengers get off the train. As a matter of fact, the Fire of Dae-gu Subway was coped with this way. But, the fire smoke extraction system of real subway stations have not designed to deal with fire of trains yet. Therefore, we have to establish a plan of station railroad for preventing from unexpected damage when the fired train comes to the station. The purpose of this study is to establish the effective smoke extraction measure that is to prevent stations from damage by the scale-down experiment.

Development of Ecological Interface Design Prototype on Integrated Safety Management System Display in Subway Station Office (도시철도 역무실 통합 안전관리시스템 디스플레이의 Ecological Interface Design Prototype 개발)

  • Lee, Bong-Geun;Back, Ji-Seung;Jo, Sung-Sik;Myung, Ro-Hae;Lee, Duck-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.661-665
    • /
    • 2010
  • Current subway station's office employee must perform safety management tasks by monitoring the various safety management systems. But these monitoring systems are limited in effective situational awareness and response to a state of emergency immediately. It is necessary to develop an integrated safety management system display. In this study, we developed subway station safety management system's (CCTV, fire detection & alarm system, screen door control equipment) integrated prototype display with ecological interface design framework and evaluated prototype display interface's usability with GOMS model. The result was that the ecological interface's performance was better than existing safety management system's interface.

A Study on the Unification of the Grounding System of SeoulMetro (서울메트로 접지설비 표준화 방안 연구)

  • Kim, Gyun-Sig;Park, Han-Yeong;Back, Yu-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1027-1036
    • /
    • 2007
  • Since the opening of the Seoul Metro in 1974, the electric railway passengers have been increased rapidly and as the advanced equipments(OC,PSD) were introduced, additional power facilities were built in a limited area for the comfortable transportation environment. Present grounding system were built according to old Electric equipment standards and all the electric signal, communication and electronic equipments were built only for the purposes of protecting building structure, people and electronic equipments. Grounding system which was additionally built in the limited area caused problems with the building structure and it caused secondary damages when earth fault happens. One of the problems is grounding system of the building structure; grounding system does not work properly since grounding equipments are not separated from each other. So, existing grounding system needs to be improved and unified grounding system in the building should be established. The purposed of this study is to analyze all the grounding systems that had been built in different year and to establish unified grounding system of Seoul Metro.

  • PDF

Detection Method Analysis for Train Correct Position Stop in Manual Operation for PSD System (수동운전 방식에서의 PSD시스템을 위한 정위치정차 판독방법 분석)

  • Lee, Moo-Ho;Yang, Gi-Hee;Park, Jung-Soun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1678-1684
    • /
    • 2007
  • Platform Screen Door(PSD) has been installed in train manual operation section(ATS/ATC) by SeoulMetro since 2005. PSDs are now operating at 17 stations in SeoulMetro lines. As a result, it increases the safety of passenger, makes a comfortable platform and saves the energy of air conditioning. For PSD operation, train shall stop within 600mm of the train stop reference point. In train manual operation section, the detection system of train position is required to notify the train driver of train position and to ensure the condition that train stops the correct position for PSD operation. To detect the train stop position, the optical sensor shall be installed at platform. However, in case of SeoulMetro lines, the detection criterions of the train correct position stop are different because of using various types of trains which have different size and shape of front cars. In this paper, to solve this problem, the precise detection algorithm of the train stop at the correct position is used, and Laser distance measure sensor is introduced to notify the distance form the reference point of the train correct stop to train driver. This system has been applying to Seoul Metro line total.

  • PDF