• 제목/요약/키워드: Screen X

검색결과 323건 처리시간 0.035초

증감지에 따른 피사체 대조도의 변화 (Effect of Intensifying Screens to Subject Contrast)

  • 이인자;허준;강홍석;윤철호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제13권2호
    • /
    • pp.27-30
    • /
    • 1990
  • It is an experimental report about object contrast according to the Kinds of screen and obtained results as follows : 1. In the same object radiography, use acquired the difference of the object contrast between LT-II ($CaWO_{4}\;system$) and G4 (Gd system) screens. 2. object contrast more decreased in Gd system screen than $CaWO_{4}$, and object contrast controlled by X-ray tube voltage. 3. The difference of object contrast seen clearly in 80 kVp.

  • PDF

심장질환 교육을 위한 Computer Assisted Learning 시스템의 개발 (Development of Computer Assisted Learning System for the Cardiac Disease)

  • 이상훈;진성희;김영권;김동운;조명찬
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.305-310
    • /
    • 1996
  • The objective of this paper is to develop computer assisted learning system for the education of cardiac disease using multimedia. Total 20 cases of disease was selected and their asculation, X-Ray, ECG, Sanography, Angiogram and RI-Study results can be shown on the computer screen. The references about cardiology, surgical process can be also shown on the screen and the computer can test and score their records for the evaluation. This system will be widely applied for the education of medicine combined wi th the communication network.

  • PDF

Back Scatter Radiation이 CR영상(影像)에 미치는 영향(影響)

  • 이후민;김학성;조남수;고승일
    • 대한디지털의료영상학회논문지
    • /
    • 제2권1호
    • /
    • pp.92-95
    • /
    • 1996
  • Computed Radiography(CR) is a relatively new technology that relies on an image plate(IP) as an alternate x-ray sensor to screen/film. Standard CR cassettes do not have lead foil behind the IP to control scatter radiation. The result of this study indicate that such control is needed. In most screen/film cassettes, that lines the rear of the cassette eliminates back scatter radiation. This study was performed to Investigate on the effects of back scatter in CR images by size of exposure field, distance between the CR cassette and the wall of radiography room. 1. It showed artifacts from hinges and clips located on the back of CR cassette by back scatter radiation. 2. The greater effects of back scatter radiation in CR images was attributed to the greater size of exposure field and the longer distance between the CR cassette and the wall of radiography room.

  • PDF

복부 단순 X-선 촬영조건과 환자 피폭에 관한 조사 연구 (A Survey on Patient Dose and Exposure Conditions in Simple Radiography of the Abdomen)

  • 김성수;이선숙;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권2호
    • /
    • pp.59-65
    • /
    • 1996
  • We studied exposure techniques and exposure dose for simple abdomen A-P projection for 41 medical facilities that are located in Seoul area. 1. The range of tube voltage used was 60 to 84 kVp, the average tube voltage used was 74 kVp 2. Only 17% of added filter was used. 3. Tube current mostly used was 200 mA, some of them used 400 mA. 4. The grid ratio mostly was used 10 : 1, 54 % of the rare earth screen was used in most facilities. 5. The average skin entrance dose was 4.15 mSv and the dose range was 1.05 mSv to 11.0 mSv.

  • PDF

증감지의 X선 Spectra 의존성에 관한 연구 (Study on the X-ray Spectra Dependence for Intensifying Screens)

  • 김영근;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.93-96
    • /
    • 1998
  • The X-ray spectra dependence for intensifying screens of medical radiography was investigated through analysis of the absorbed coefficiency(${\mu}$), absorbed efficiency(η$\sub$${\alpha}$/) and absorbed ratio(R). It was found that the absorbed coefficiency was increased in the order of CaWO$_4$$_4$ screen showed the highest value.

  • PDF

LIGA process를 이용한 micro CPL(Capillary Pumped Loop)제작 (manufacturing micro CPL (Capillary Pumped Loop)by using LIGA process)

  • 조진우;정석원;박준식;박순섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1881-1883
    • /
    • 2001
  • We manufactured a micro CPL by LlGA process, a new conceptual ultra-fine and precise forming method, using X-ray lithography process. We fabricated a BN X-ray mask having properties of good X-ray transmittance and large mechanical strength. Micro CPL was manufactured by dividing into an upper plate and a low plate. Each of plates was bonded by Ag paste screen printing. The upper plate was fabricated on glass wafer to observe flow and phase transformation of cooling solution. The lower plate was manufactured by Cu electroplating for good heat transmission. Precision of inner Parts, micro pin and micro channel, of manufactured micro CPL is under ${\pm}2{\mu}m$.

  • PDF

$BaTiO_3$계 후막의 유전특성에 관한 연구 (A Study on the Dielectric Properties of BSCT Thick Films)

  • 이성갑;김지헌;이영희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1504-1506
    • /
    • 2002
  • $(Ba_{0.6-x}-Sr_{0.4}Ca_x)TiO_3$ (x=0.10, 0.15, 0.20, y=$0.0{\sim}3.0$) powders were fabricated by the sol-gel method, and BSCT thick films were fabricated by the silk-screen printing method. Their structural and dielectric properties were investigated with variation of composition ratio. All BSCT thick films showed a homogeneous structure without presence of the second phase. BSCT film thickness, obtained by three cycle of printing, was approximately $80{\mu}m$. The dielectric constant and dielectric loss of the 3-coated BSCT(50/40/10) thick film were approximately 1700 and 0.07%, respectively.

  • PDF

New X-Y Channel Driving Method for LED Backlight System in LCD TVs

  • Cho, Dae-Youn;Oh, Won-Sik;Cho, Kyu-Min;Moon, Gun-Woo;Yang, Byung-Choon;Jang, Tae-Seok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.1001-1004
    • /
    • 2007
  • This paper proposes a novel RGB-LED (light emitting diode) backlight system, for 32" LCD TVs, accompanied by a new X-Y Channel driving method in which its row and column switches control the individual division screen. This proposed driving method is able to produce division driving effects such as image improvement and reduced power consumption. Not only that, the number of driver needed in this method, that is 3 power supplies with 3*(m+n) switches, is much fewer than that of cluster driving method, that is 3*(m*n) driver.

  • PDF

디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구 (Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography)

  • 김호경;조민국
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.

$Cu(In_{1-x}Ga_x)Se_2$ Thin Film Fabrication by Powder Process

  • Song, Bong-Geun;Cho, So-Hye;Jung, Jae-Hee;Bae, Gwi-Nam;Park, Hyung-Ho;Park, Jong-Ku
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2012년도 춘계학술발표대회
    • /
    • pp.92-92
    • /
    • 2012
  • Chalcopyrite-type Cu(In,Ga)Se2 (CIGS) is one of the most attractive compound semiconductor materials for thin film solar cells. Among various approaches to prepare the CIGS thin film, the powder process offers an extremely simple and materials-efficient method. Here, we present the mechano-chemical synthesis of CIGS compound powders and their use as an ink material for screen-printing. During the synthesis process, milling time and speed were varied in the range of 10~600 min and 100~300 rpm, respectively. Both phase evolution and powder characteristics were carefully monitored by X-ray diffraction (XRD) method, scanning electron microscope (SEM) observation, and particle size analysis by scanning mobility particle spectrometer (SMPS) and aerodynamic particle sizer (APS). We found the optimal milling condition as 200 rpm for 120 min but also found that a monolithic phase of CIGS powders without severe particle aggregation was difficult to be obtained by the mechano-chemical milling alone. Therefore, the optimized milling condition was combined with an adequate heat-treatment (300oC for 60 min) to provide the monolithic CIGS powder of a single phase with affordable particle characteristics for the preparation of CIGS thin film. The powder was used to prepare an ink for screen printing with which dense CIGS thin films were fabricated under the controlled selenization. The morphology and electrical properties of the thin films were analyzed by SEM images and hall measurement, respectively.

  • PDF