• Title/Summary/Keyword: Screen Use Detection

Search Result 70, Processing Time 0.027 seconds

Amperometric Detection of DNA by Electroreducation of O2 in an Enzyme-Amplified Two-Component Assay

  • Yoon Chang-Jung;Kim Hyug-Han
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.1
    • /
    • pp.44-48
    • /
    • 2004
  • The two-component type enzyme amplified amperometric DNA assay is described to use an ambient $O_2$ of the substrate of the DNA labeling enzyme. Although the assay detects DNA only at > 0.5M concentration, a concentration $\~10^6$ fold higher than the sandwich-type enzyme amplified amperometric DNA assay, it can be run with an always available substrate. The assay utilizes screen-printed carbon electrodes (SPEs) which were pre-coated by a co-electrodeposited film of an electron conducting redox hydrogel and a 37-base long single-stranded DNA sequence. The DNA in the electron conducting film hybridizes and captures, when present, the 37-base long detection-DNA, which is labeled with bilirubin oxidase (BOD), an enzyme catalyzing the four-electron reduction of $O_2$ to water. Because the redox hydrogel electrically connects the BOD reaction centers to the electrode, completion of the sandwich converts the film from non-electrocatalytic to electrocatalytic for the reduction of $O_2$ to water when the electrode is poised at 200 mV vs. Ag/hgCl. The advantage or the assay over the earlier reported sandwich type enzyme amplified amperometric DNA assay, in which the amplifying enzyme was horseradish peroxidase, is that it utilizes ambient $O_2$ instead of the less stable and naturally unavailable $H_2O_2$.

An User-Friendly Kiosk System Based on Deep Learning (딥러닝 기반 사용자 친화형 키오스크 시스템)

  • Su Yeon Kang;Yu Jin Lee;Hyun Ah Jung;Seung A Cho;Hyung Gyu Lee
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.29 no.1
    • /
    • pp.1-13
    • /
    • 2024
  • This study aims to provide a customized dynamic kiosk screen that considers user characteristics to cope with changes caused by increased use of kiosks. In order to optimize the screen composition according to the characteristics of the digital vulnerable group such as the visually impaired, the elderly, children, and wheelchair users, etc., users are classified into nine categories based on real-time analysis of user characteristics (wheelchair use, visual impairment, age, etc.). The kiosk screen is dynamically adjusted according to the characteristics of the user to provide efficient services. This study shows that the system communication and operation were performed in the embedded environment, and the used object detection, gait recognition, and speech recognition technologies showed accuracy of 74%, 98.9%, and 96%, respectively. The proposed technology was verified for its effectiveness by implementing a prototype, and through this, this study showed the possibility of reducing the digital gap and providing user-friendly "barrier-free kiosk" services.

Single Shot Detector for Detecting Clickable Object in Mobile Device Screen (모바일 디바이스 화면의 클릭 가능한 객체 탐지를 위한 싱글 샷 디텍터)

  • Jo, Min-Seok;Chun, Hye-won;Han, Seong-Soo;Jeong, Chang-Sung
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.1
    • /
    • pp.29-34
    • /
    • 2022
  • We propose a novel network architecture and build dataset for recognizing clickable objects on mobile device screens. The data was collected based on clickable objects on the mobile device screen that have numerous resolution, and a total of 24,937 annotation data were subdivided into seven categories: text, edit text, image, button, region, status bar, and navigation bar. We use the Deconvolution Single Shot Detector as a baseline, the backbone network with Squeeze-and-Excitation blocks, the Single Shot Detector layer structure to derive inference results and the Feature pyramid networks structure. Also we efficiently extract features by changing the input resolution of the existing 1:1 ratio of the network to a 1:2 ratio similar to the mobile device screen. As a result of experimenting with the dataset we have built, the mean average precision was improved by up to 101% compared to baseline.

A Study on the Implementation of A Fire Detection Monitoring System to Improve Data-Rate in WSN Environment (WSN 환경에서 전송률 향상을 고려한 화재감지 모니터링 시스템 구축에 관한 연구)

  • Lee, Jae-Soo;Yun, Chan-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.96-102
    • /
    • 2011
  • There are many problems with the fire detection devices being used in currently, because it is difficult to find location of the source of fire and determine where devices are working or not. In this paper, we proposed fire detection and rescue system using wireless sensor network that can be real-time monitoring and determine safe exit. Fire detection and rescue system based on ubiquitous sensor network can know exactly source of fire and help determine rescue tactics using sensing data from wireless sensor nodes. Transmitted wirelessly in real-time thermal sensor and gas sensor information to analyze the GUI to monitor the status information output to the screen by use of a system implemented in everyday life, looked at the possibility.

Development of Immunostrip for DDT Detection

  • Hong, Ji-Youn;Kim, Joung-Hyun;Lee, Eun-Ah;Choi, Myung-Ja
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.407.1-407.1
    • /
    • 2002
  • To develop immunostrip of DDT (4.4'-dichlorodiphenyl-2.2,2-trichloroethane) and its metabolites, DDT derivatives (DDA-. DDHP-. DDCP-. DDHH-. and DDHHAP-) were conjugated to carrier proteins (OVA and BSA) and three DDT derivatives (DDA. DDHP. DDCP) were conjugated to KLH for the use of coating ligand and immunogen. respectively. To screen the immunoreactivity of antibody to DDT derivatives, the coating ligand was evaluated by a competitive ELISA and DDHP-OVA was selected. (omitted)

  • PDF

Fingertip Touch Recognition using Shadow Information for General Wall Touch Screen (일반벽 터치 스크린의 손가락 터치 판별을 위한 그림자 정보의 사용)

  • Jeong, Hyun-Jeong;Hwang, Tae-Ryang;Choi, Yong-Gyun;Lee, Suk-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.12
    • /
    • pp.1430-1436
    • /
    • 2014
  • We propose an algorithm which detects the touch of the fingertip on a general wall using the shadow information. Nowadays, there is a demand for presentation systems which can perceive the presenter's action so that the presenter can use natural movements without extra interface hardware. One of the most fundamental techniques in this area is the detection of the fingertip and the recognition of the touch of the fingertip on the screen. The proposed algorithm recognizes the touch of the fingertip without using the depth information, and therefore needs no depth or touch sensing devices. The proposed method computes the convex hull points of both the fingertip and the shadow of the fingertip, and then computes the distance between those points to decide whether a touch event has occured. Using the proposed method, it is possible to develop a new projector device which can perceive a fingertip touch on a general wall.

Lung Cancer Detection by Screening - Presenting Circulating miRNAs as a Promising Next Generation Biomarker Breakthrough

  • Ramshankar, Vijayalakshmi;Krishnamurthy, Arvind
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2167-2172
    • /
    • 2013
  • Lung cancer remains a major cause of morbidity and mortality worldwide, accounting for more deaths than any other cause. All the clinical practice guidelines recommended against routine screening for lung cancer have cited lack of robust evidence, at least until a few years back. However, the potential to screen lung cancers has received renewed interest due to superior performance of low dose CT (LD-CT) in detecting early stage cancers. The incremental costs and risks involved due to the invasive procedures in the screened population due to a high false positivity rate questions the use of LD-CT scan as a reliable community based screening tool. There is therefore an urgent need to find a less invasive and a more reliable biomarker that is crucial to increase the probability of early lung cancer detection. This can truly make a difference in lung cancer survival and at the same time be more cost and resource utilization effective. Sampling blood serum being minimally invasive, low risk and providing an easy to obtain biofluid, needs to be explored for potential biomarkers. This review discusses the use of circulatory miRNAs that have been able to discriminate lung cancer patients from disease free controls. Several studies conducted recently suggest that circulating miRNAs may have promising future applications for screening and early detection of lung cancer.

Electrochemical Immunoassay for Detecting Hippuric Acid Based on the Interaction of Osmium-Antigen Conjugate Films with Antibody on Screen Printed Carbon Electrodes

  • Choi, Young-Bong;Jeon, Won-Yong;Kim, Hyug-Han
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1485-1490
    • /
    • 2012
  • An electrochemical immunoassay based on osmium-hippuric acid (HA) conjugate films onto the electrode is presented for the detection of urinary HA. This is the first report on the use of the oxidative electropolymerization of 5-amino-1,10-phenanthroline (5-$NH_2$-phen) for immobilizing an antigen, osmium-conjugated HA. As a redox mediator, [Os(5-amino-1,10-phenanthroline)$_2$(4-aminomethylpyridine-HA)Cl]$^{+/2+}$ (Os-phen-HA) was successfully synthesized and electropolymerized onto the screen-printed carbon electrodes (SPCEs). The interaction between osmium-HA conjugate films and antibody-HA ($anti$-HA) was performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The electrical signals were linearly proportional to urinary HA in the range of 0.1-5.0 mg/mL, which is sufficient for use as an immunosensor using a cutoff concentration of 2.0 mg/mL in urine samples. The proposed electrochemical immunoassay method can be extended to various applications for detecting a wide range of different small antigens in the health care area.

A Study on Touch Recognition Improvement using Contrast Detection Method (대비검출방식을 이용한 터치 인식 개선방법에 관한 연구)

  • Park, jae-wan;Song, dae-hyeon;Kim, jong-gu;Kim, dong-min;Lee, chil-woo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.169-172
    • /
    • 2009
  • In this paper, we propose the method to improving touch recognition using edge mask on a touched object at vision-based touchscreen. Because vision-based touchscreen recognizes touch using threshold simply, noise occur in fist or wrist in case of touch directly with hand, correct touch recognition was difficult. However, in this paper, we execute morphology and extract surrounding mask in object that approximate to touchscreen, use change of contrast for the mask. When we touch screen to use these dynamic information, prevent noise. The goal of this paper is when hand was touched on screen it can recognize to touch.

  • PDF

Urban Growth Monitoring using Multi-temporal Satellite Images and Geographic Information

  • Lee, Kwang-Jae;Kim, Youn-Soo;Kim, Byung-Kyo
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.470-472
    • /
    • 2003
  • The primary goal in this paper is to analyze urban growth patterns using multi-temporal remote sensing images and geographic information data. In order to accomplish this purpose, firstly data pre-processing is carried out, and then land-use maps are generated with ancillary data source by heads-up on-screen digitizing. Lastly, using the results of the previous stages, the patterns of land-use and urban changes are monitored by the proposed scheme. In this research, using the multi-temporal images and geographic information data, monitoring of urban growth was carried out with the application of urban land-use changes.

  • PDF