• Title/Summary/Keyword: Screen Door Effect

Search Result 16, Processing Time 0.023 seconds

The Effect of Platform Screen Doors on PM10 Levels in a Subway Station and a Trial to Reduce PM10 in Tunnels

  • Son, Youn-Suk;Salama, Amgad;Jeong, Hye-Seon;Kim, Suhyang;Jeong, Jin-Ho;Lee, Jaihyo;SunWoo, Young;Kim, Jo-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.38-47
    • /
    • 2013
  • $PM_{10}$ concentrations were measured at four monitoring sites at the Daechaung station of the Seoul subway. The four locations included two tunnels, a platform, and a waiting room. The outside site of the subway was also monitored for comparison purposes. In addition, the effect of the platform screen doors (PSDs) recently installed to isolate the $PM_{10}$ in a platform from a tunnel were evaluated, and a comparison between $PM_{10}$ levels during rush and non-rush hours was performed. It was observed that $PM_{10}$ levels in the tunnels were generally higher than those in the other locations. This might be associated with the generation of $PM_{10}$ within the tunnel due to the train braking and wear of the subway lines with the motion of the trains, which promotes the mixing and suspension of particulate matter. During this tunnel study, it was observed that the particle size of $PM_{10}$ ranged from 1.8 to 5.6 ${\mu}m$. It was revealed that the $PM_{10}$ levels in the tunnels were significantly increased by the PSDs, while those in the platform and waiting room decreased. As a result, in order to estimate the effect of ventilation system on $PM_{10}$ levels in the tunnels, fans with inverters were operated. It was found that the concentration of $PM_{10}$ was below 150 ${\mu}g/m^3$ when the air flow rate into a tunnel was approximately 210,000-216,000 CMH.

A study of improvement of uncertainty by repeated measurement for PSD(Platform Screen Door) Performance Test (승강장 스크린 도어 시스템 특성 시험의 반복 측정에 의한 불확도 개선 고찰)

  • Ohn, Jung-Ghun;Kim, Myung-Yong;Yun, Myung-Sang;Kim, Won-Kyong;Won, Si-Tae
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1671-1674
    • /
    • 2007
  • A PSD system has a lot of characteristic for safety. Trust of performance test is very important. But PSD performance test has an effect on trust by proficiency of test staff because it is difficult to automate. In that specially the effort test, manual opening and shutting test and abrasion measurement, test staff is demanded for proficiency. Therefore the paper repeated measurement in same condition and studied proficient factor of examiner according to increased measurement counter. As a result, measurement uncertainty has improved.

  • PDF

Visualization of Smoke Flow in the Subway Fire (지하철 화재발생시 역사내 화재연기 거동 가시화 연구)

  • Choi Chang Jin;Jung Hae Gon;Kim Sang Moon;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.64-68
    • /
    • 2005
  • In this study, the smoke flows of the inner subway station were visualized through a numerical analysis and visualization experiment in the subway fire. A transparent acrylic model was designed and installed as 1:25th scale-down as the actual subway station by using geometrical similarity The properties of subway fire were reconstructed according to Densimetric Froude Similarity. The 47 to 53 ratio of the mixed air and Helium was inputted in the inner acrylic model to describe 1MW fire intensity with reference to the experiment paper. For the same time, the fire smoke from a smoke generator was inputted in the inner acrylic model with the mixture. At this time, the buoyancy effect of Helium gas went up the smoke to the acrylic model. When the sheet beam of Ar-lon laser was given out to the top and stair of subway model, the digital camcorder took the images of the scattered cluster of smoke particles when applying the smoke management system and PSD.

  • PDF

Rotating Brush Strokes to Track Movement for Painterly Rendering (회학적 렌더링에서 움직임을 따라 회전하는 붓질 기법)

  • Han, Jeong-Hun;Gi, Hyeon-U;Kim, Hyo-Won;O, Gyeong-Su
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.426-432
    • /
    • 2008
  • We introduce a method of rendering a scene lying 3D objects which is like that artist draw on a canvas by brushing. Painting is the art area presenting something created by color and line on 2D plane. We are brushing on billboards on screen space for the 2D brushing effect according to the definition of "Painting". Brushing orientation is haven to rotate for preventing the orientation in the first scene in the case that object or camera are moving. If the brushing isn't rotated, shower-door effect is watched on the scene as undesirable result We present a brushing rotating method for keeping the orientation changing the direction of view and object rigid animation. The brushing direction is computed with Horn's 2D similarity transform by least-square solution. We watched the changing brushing to track the motion of object and view.

  • PDF

Research Study on Indoor Air Quality (IAQ) inside of the Subway Cabin in Seoul Metropolitan City (지하철 전동차 객실 내부 공기질 조사 연구)

  • Lee, Kyoung Bin;Kim, Jin Sik;Bae, Sung Joon;Kim, Shin Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.2
    • /
    • pp.175-187
    • /
    • 2014
  • The subways play an important part in serious traffic problems. Almost seven million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan city in 2012. However, the subway system is a semi-closed environment, so many serious problems occurred in subway stations and injured passengers' health. Platform screen doors (PSD) are expected to prevent negligent accident such as injury or death from falling and improve the air quality of the subway station. Installation of PSD at stations in Seoul metropolitan subway had been completed in December 2009. Consequently, the underground transportation system became a closed environment, so the air quality has improved the platforms, but it has deteriorated in the tunnels. Especially, the subway cabin has many doors, and the doors are frequently opened and closed. For this reason, the effect of door opening on subway cabin, dust flow inside the subway cabin. In this process, the maintenance work may influence the health of people who work underground, as well as that of subway users (passengers). In this study, we measured air quality inside and outside of the subway cabin line 2 in Seoul, Korea. This study focused on the investigation of Indoor Air Quality (IAQ) and measurement target pollutants are PM10, CO, $CO_2$, $NO_2$, $O_3$. It was found that levels of PM10, $CO_2$, and $NO_2$ inside subway cabin line 2 exceeded the Korea IAQ standard. Concentrations of PM10, $CO_2$, and $NO_2$ inside of the cabin are higher than outside of the cabin (Indoor Outdoor ratio is higher than 1.). Concentrations of CO, $O_3$ inside of the cabin are lower than outside of the cabin (Indoor Outdoor ratio is lower than 1.). There is a high correlation between $CO_2$ and passengers inside of the cabin and PM10 is only the weakest correlation with passengers. Therefore, it is important to find out the emission source of $NO_2$. The results of this study will be useful as fundamental data to study indoor air quality of a subway cabin.

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screens Doors are Installed - Analysis on Smoke Control Performance by Fans equipped in Tunnel (스크린도어가 설치된 대심도 지하역사의 제연 실험 - 터널 송풍기에 의한 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.9
    • /
    • pp.721-736
    • /
    • 2019
  • In this paper, the behavior of the fire smoke due to the operation of the ventilation systems when the fire occurred in the underground station (6 basement floors) and the tunnel at the great depth was measured. Fire smoke was generated by using a smoke generator which realized heat buoyancy effect by using hot air blower. The two locations of the fire were selected on the platform and on the platform of the tunnel located outside the screen door. A ventilation mode is generally used in which smoke is exhausted through a vent hole provided in a platform when a platform fire occurs. The tests were performed by operating the exhaust through the ventilation holes of the tunnel part located at both ends of the platform. The smoke density and the wind speed/velocity were measured at various positions, and the videos were taken to analyze the movement and smoke of the smoke. In both cases for fire inside the platform and in the railway tunnel, due to the ventilation mode operation of the fan for the platform and the exhaust of the fans in the tunnel smoke were well exhausted and the smoke propagation to the area near the smoke zone was suppressed. The smoke-control mode, which is applied to both fans for the platform and fans for in the tunnel at both ends of the platform, can provide a safer evacuation environment to the passengers from the fire smoke when the platform fire or fire train stops.