• Title/Summary/Keyword: Scratch 2.0

Search Result 87, Processing Time 0.027 seconds

SELECTED MECHANICAL PROPERTIES OF ORMOCER RESTORATIVE MATERIALS (Ormocer 계열 수복재의 물성에 관한 연구)

  • Lee, Dong-Soo;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.362-370
    • /
    • 2002
  • During the last two decades, many new filling materials and material groups have been developed. the number of available restoratives has increased dramatically, especially during the last 5 years. Ormocers are a new class of materials which are still under development with regard to dental applications. However, in the chemical literature these materials have been known for a long time and used for producing scratch resistant coatings on plastic spectacle lenses. It is a combination of inorganic and organic materials. 'Ormocer' is an abbreviation for 'Organically Modified Ceramics'. These compounds are also known in the literature as 'Ormosils' (organically modified silicates). Their chemistry is comparable to that of silicones and organic polymers. The purpose of this study was to determine of compressive strength and flexural strength of a ormocer (Admira) and to investigate the effects of water absorption in comparison with three composite resins(Z-100, Tetric Ceram, Surefil) and one compomer(Dyract AP). The following results were obtained ; 1. Admira had the lower compressive strength than Surefil, but no statistically difference with other materials at 1 day(p>0.05). 2. Admira had the lower flexural strength than all other materials at 1 day. From 2 days, Admits showed lower flexural strength than three composite resin(p<0.05). 3. There was not statistically significant difference of compressive and flexural strengths between hybrid composite resin group(Z-100, Tetric Ceram) and Packable resin group(Surefil) for experimental period(30 days)(p>0.05). 4. All five materials showed an increase in compressive and flexural strength till 2 days and showed a decrease from 7 days in water(p<0.05). 5. Each materials had the statistically similar behavior of compressive and flexural strengths over time(p>0.05).

  • PDF

Relationship between Functional Fitness and Break Response in Elderly Drivers: Comparison with Young Driver

  • Kim, Ga Eun;Choi, Ye Eun;Yang, Su Seong;Kim, Sun A;Bae, Young Sook
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.5
    • /
    • pp.187-192
    • /
    • 2018
  • Purpose: This study compared the functional fitness and brake response of elderly and young drivers to confirm the correlation between the functional fitness and brake response. Methods: This study was a cross sectional observational design. Older drivers (>65age, n=21) and young adult drivers (20-40aged, n=20) were enrolled as subjects. The functional fitness of the subjects was measured using a senior fitness test consisting of a back scratch (BS), chair sit and reach (CSR), arm curl (AC), chair stand up (CSU), foot up and go (8-FUG), and 2-minute step (2-MS). The brake response used the virtual driving simulator to measure the brake reaction time (BRT) and braking distance (BD) according to the pedestrian protection and traffic signal compliance. Results: The older drivers had a lower BS (p<0.000), CSU (p=0.040), and 8-FUG (p=0.011) than the young adult drivers. BS and 8-FUG showed a significant positive correlation with the BRT and BD of pedestrian protection and traffic signal compliance. CSU showed a significant negative correlation with the BRT of pedestrian protection and traffic signal compliance. Conclusion: These findings suggest that the flexibility of the upper extremity, lower extremity strength, and agility are strongly correlated with the driving performance of elderly drivers.

Effects of 36 Weeks of Resistance Training on Body Composition, Fitness and Blood Lipid Profiles in the Obese Elderly (36주간 저항성 운동이 비만노인의 신체구성, 체력 및 혈중 지질에 미치는 영향)

  • So, Wi-Young;Song, Mi-Soon;Cho, Bi-Long;Park, Yeon-Hwan;Lim, Jae-Young;Kim, Seon-Ho;Song, Wook
    • Journal of Korean Public Health Nursing
    • /
    • v.24 no.1
    • /
    • pp.39-48
    • /
    • 2010
  • Purpose: To examine the effects of a 36-week resistance training program on body composition, fitness and blood lipid profiles in the obese elderly. Method: fourteen subjects were assigned into the resistance training group. The 12-16 exercise sessions were performed for 60min with 15-25 repetitions twice per week for 36 weeks. Data were analyzed by paired t-test with SPSS version 12.0 for Windows. Results: Significant changes were evident in weight (t=5.983, p<.001), body mass index (t=5.922, p<.001), % body fat (t=3.480, p=.004), and fat free mass (t=-2.592, p=.022). Concerning exercises, no significance was noted for back scratch (t=-1.814, p=.093), but were for 2-min step (t=-3.075, p=.009), arm curl (t=-2.223, p=.045), chair stand (t=-3.671, p=.003), chair sit and reach (t=-2.508, p=.026), and 8-ft up and go (t=5.545, p<.001). No significant changes were evident in total cholesterol (t=1.189, p=.279), and total glucose (t=0.689, p=.517), while the change in high-density lipoprotein was significant (t=3.535, p=.012). Conclusion: The 36-week resistance training program enhanced body composition and physical fitness, but not blood lipid profiles in obese elderly subjects.

Development of Robot Vision Technology for Real-Time Recognition of Model of 3D Parts (3D 부품모델 실시간 인식을 위한 로봇 비전기술 개발)

  • Shim, Byoung-Kyun;Choi, Kyung-Sun;jang, Sung-Cheol;Ahn, Yong-Suk;Han, Sung-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.16 no.4
    • /
    • pp.113-117
    • /
    • 2013
  • This paper describes a new technology to develop the character recognition technology based on pattern recognition for non-contacting inspection optical lens slant or precision parts, and including external form state of lens or electronic parts for the performance verification, this development can achieve badness finding. And, establish to existing reflex data because inputting surface badness degree of scratch's standard specification condition directly, and error designed to distinguish from product more than schedule error to badness product by normalcy product within schedule extent after calculate the error comparing actuality measurement reflex data and standard reflex data mutually. Developed system to smallest 1 pixel unit though measuring is possible 1 pixel as $37{\mu}m{\times}37{\mu}m$ ($0.1369{\times}10-4mm^2$) the accuracy to $1.5{\times}10-4mm$ minutely measuring is possible performance verification and trust ability through an experiment prove.

Plating of Cu layer with the aid of organic film on Si-wafer (유기박막을 이용한 Si기판상의 구리피복층 형성에 관한 연구)

  • Park Ji-hwan;Park So-yeon;Lee Jong-kwon;Song Tae-hwan;Ryoo Kun-kul;Lee Yoon-bae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.50-53
    • /
    • 2004
  • 본 논문에서는 Si wafer와 Cu사이의 밀착력을 증가시키기 위해 Si wafer전처리 후 plasma와 SAMs처리 방법에 의한 Cu도금의 형성에 관한 방법을 설명하였다. Si wafer를 Piranha solution과 $0.5\%$ HF처리 후 유기박막인 SAMs과 plasma를 이용하는 방법으로 wafer와 Cu층 사이의 밀착력을 증가시켰다. 도금층의 밀착력은 scratch test 로 측정하였으며, AEM을 이용해 시편에 형성된 패턴의 형태를 관찰하고 SEM과 EDS를 이용해 시편의 조직을 관찰하였다. 그 결과 Si wafer를 O2, He, SAMs를 혼합처리 했을 때 밀착성이 가장 우수하였다.

  • PDF

Evaluation of Age-Hardening Characteristics of Rheo-Cast A356 Alloy by Nano/Micro Hardness Measurement (나노/마이크로 경도 측정에 의한 레오캐스트 A356 합금의 시효경화특성 평가)

  • Cho S. H.;Youn S. W.;Kang C. G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.471-474
    • /
    • 2005
  • This study investigates the nano/microstructure, the aging response, and the mechanical/tribological properties of the eutectic regions in rheoformed A356 alloy-T5 parts using nano/micro-indentation and mechanical scratching, combined with optical microscopy and atomic force microscope (AFM). Most eutectic Si crystals in the A356 alloy showed a modified morphology as fine-fibers. The loading curve for the eutectic region was more irregular than that of the primary Al region due to the presence of various particles of varying strength. The aging responses of the eutectic regions in the rheoformed A356 alloys aged at $150^{\circ}C$ for different times (0, 2, 4, 8, 10, 16, 24, 36, and 72 h) were investigated. Both Victors hardness $(H_v)$ and indentation $(H_{IT})$ test results showed a similar trend of aging curves, and the peak was obtained at the same aging time of 10 h. A remarkable size-dependence of the tests was found.

  • PDF

Effect of Rolling Conditions on the Sticking Phenomena of Ferritic Stainless Steel (페라이트계 스테인레스강의 Sticking 현상에 미치는 열간압연조건의 영향)

  • Jin, Won;Choi, Joem-Yong
    • Transactions of Materials Processing
    • /
    • v.6 no.2
    • /
    • pp.110-117
    • /
    • 1997
  • Sticking behavior under the hot rolling conditions for ferritic stainless steels have been studied. Sticking, which is a phenomenon that the naked metal exposed to the surface by scale breakaway during hot rolling sticks to the roll surface, was affected by both high temperature tensile strength and oxidation resistance of the steels. A steel having higher tensile strength and lower oxidation resistance exhibits better resistance to the sticking. It is due to that higher tensile strength increases localized deformation resistance and lower oxidation resistance creates lower friction between steel and roll by forming thicker scale as a lubricant during hot rolling. So, the sticking tends to occur more severely in the order of 430J1L, 436L, 430 and 409L. The most sensitive temperature to the sticking was found to be 90$0^{\circ}C$ for all grade of steels. It was also found that the high speed steel(HSS) roll compared to the Hi-Cr roll was more beneficial to prevent sticking. Because higher surface hardness of HSS roll compared to that of Hi-Cr roll provides less nucleation sites for sticking such as scratch on the roll surface.

  • PDF

Effects of Cryogenic Temperature on Wear Behavior of 22MnB5 Under Cold Stamping (극저온이 22MnB5강의 냉간 스탬핑 마모에 미치는 영향)

  • Ji, Min-Ki;Noh, Yeonju;Kang, Hyun-Hak;Jun, Tea-Sung
    • Tribology and Lubricants
    • /
    • v.38 no.6
    • /
    • pp.241-246
    • /
    • 2022
  • This paper presents the effects of cryogenic temperature on the wear behavior of 22MnB5 blank under cold stamping. After immersing the blank in liquid nitrogen (LN2) for 10 min, a strip drawing test was performed within 10 s. The hardness was measured using the Rockwell hardness test, which increased from 165 HV at 20℃ to 192 HV at cryogenic temperature. The strip drawing test with 22MnB5 blank and SKD61 tool steel shows that for the different wear mechanisms on the tool surface with respect to temperature; adhesive wear is dominant at 20℃, but abrasive wear is the main mechanism at cryogenic temperature. As the friction test is repeated, sticking gradually increases on the tool surface at 20℃, whereas the scratch increases at cryogenic temperature. For the friction behavior, the friction coefficient rapidly increases when adhesive wear occurs, and it occurs more frequently at 20℃. The results for nanoindentation near the worn blank surface indicate a difference of 1.3 GPa at 20℃ and 0.8 GPa at cryogenic temperature compared to the existing hardness, indicating increased deformation by friction at 20℃. This occurs because thermally activated energy available to move the dislocation decreases with decreasing temperature.

Synthesis of WC-CrN superlattice film by cathodic arc ion plating system

  • Lee, Ho. Y.;Han, Jeon. G.;Yang, Se. H.
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.5
    • /
    • pp.421-428
    • /
    • 2001
  • New WC-CrN superlattice film was deposited on Si substrate (500$\mu\textrm{m}$) using cathodic arc ion plating system. The microstructure and mechanical properties of the film depend on the superlattice period (λ). In the X-ray diffraction analysis (XRD), preferred orientation of microstructure was changed according to various superlattice periods(λ). During the Transmission Electron Microscope analysis (TEM), microstructure and superlattice period (λ) of the WC - CrN superlattice film was confirmed. Hardness and adhesion of the deposited film was evaluated by nanoindentation test and scratch test, respectively. As a result of nanoindentation test, the hardness of WC - CrN superlattice film was gained about 40GPa at superlattice period (λ) with 7nm. Also residual stress with various superlattice period (λ) was measured on Si wafer (100$\mu\textrm{m}$) by conventional beam-bending technique. The residual stress of the film was reduced to a value of 0.2 GPa by introducing Ti - WC buffer layers periodically with a thickness ratio ($t_{buffer}$/$t_{buffer+superlattice}$ ). To the end, for the evaluation of oxidation resistance at the elevated temperature, CrN single layer and WC - CrN superlattice films with various superlattice periods on SKD61 substrate was measured and compared with the oxidation resistance.

  • PDF

Effects of TiN and ZrN Coating on Surface Characteristics of Orthodontic Wire (교정용 와이어의 표면특성에 미치는 TiN 및 ZrN 코팅영향)

  • Kim, W.G.;Kim, D.Y.;Choe, H.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.4
    • /
    • pp.147-155
    • /
    • 2008
  • The dental orthodontic wire provides a good combination of strength, corrosion resistance and moderate cost. The purpose of this study was to investigate the effects of TiN and ZrN coating on corrosion resistance and physical property of orthodontic wire using various instruments. Wires(round type and rectangular type) were used, respectively, for experiment. Ion plating was carried out for wire using Ti and Zr coating materials with nitrogen gas. Ion plated surface of each specimen was observed with field emission scanning electron microscopy(FE-SEM), energy dispersive X-ray spectroscopy(EDS), atomic force microscopy(AFM), vickers hardness tester, and electrochemical tester. The surface of TiN and ZrN coated wire was more smooth than that of other kinds of non-coated wire. TiN and ZrN coated surface showed higher hardness than that of non-coated surface. The corrosion potential of the TiN coated wire was comparatively high. The current density of TiN coated wire was smaller than that of non-coated wire in 0.9% NaCl solution. Pit nucleated at scratch of wire. The pitting corrosion resistance $|E_{pit}-E_{rep}|$ increased in the order of ZrN coated(300 mV), TiN coated(120 mV) and non-coated wire(0 mV).