• 제목/요약/키워드: Scintillator

검색결과 276건 처리시간 0.027초

Photoluminescence Property of Lu2Si2O7:Ce3+ Powder for Scintillator

  • Kim, Kyung-Nam;Cao, Guozhong
    • 한국재료학회지
    • /
    • 제26권4호
    • /
    • pp.212-215
    • /
    • 2016
  • In this paper, cerium doped lutetium pyrosilicate (LPS) powders with cerium content (0.05 and 0.07 mol%) were prepared by sol-gel process. The formation of lutetium pyrosilicate (LPS) phase was confirmed by XRD analysis for the powders heated at $1,200^{\circ}C$; in these powders, a single phase of $Lu_2Si_2O_7$ (LPS) was observed. Cerium doped lutetium pyrosilicate (LPS) powder was agglomerated and constituted of small spherical particles with diameters of about 300 nm. The photoluminescence spectra of the $Lu_2Si_2O_7:Ce^{3+}$ powders showed the characteristic of excitation and there was an emission spectrum for $Ce^{3+}$ in the host of $Lu_2Si_2O_7$. The emission spectrum shows a broad band in the range of 350-525 nm; the broad wavelength on the right side of the spectra should be ascribed to the same 5d-4f transitions of $Ce^{3+}$, as in the case of cerium doped $Lu_2Si_2O_7$ single crystals.

광 도시메트리시스템을 이용한 치료용 6 MV X선 선량분포 평가 (Evaluation of Dose Distribution of 6 MV X-ray using Optical Dosimetry)

  • 김성환
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.925-932
    • /
    • 2019
  • 플라스틱 섬광체와 상용 50 mm, f1.8 렌즈 및 고감도 CMOS 카메라를 사용하여 방사선치료 시 흡수선량을 측정할 수 있는 광 도시메트리 시스템을 구축하였다. 아울러 촬영된 방사선 분포 영상에 대한 비네팅 보정, 기하학적 왜곡 보정, 스케일 보정을 통하여 화소값으로 선량을 교정하는 절차를 확립하였다. 개발된 광 도시메트리 시스템을 6 MV 의료용 선형가속기에 대하여 선량 특성 평가를 수행한 결과, 심부선량백분율은 이온챔버로 측정한 결과에 비하여 빌드 업 깊이 이상에서는 오차 범위 2% 이내로 일치하였으며, 90% 조사야에 대하여 2.8%의 평탄도가 측정됨에 따라 방사선치료선량 측정 시스템으로서의 충분한 활용가능성을 확인하였다.

섬광검출을 위한 플라스틱광섬유에서의 체렌코프 빛 측정 및 제거 (Measurement and removal of a cerenkov light in a plastic optical fiber to detect a scintillating light)

  • 조동현;장경원;유욱재;신상훈;이봉수;박병기;조효성;김신
    • 센서학회지
    • /
    • 제17권2호
    • /
    • pp.100-105
    • /
    • 2008
  • The objectives of this study are to measure and to remove Cerenkov lights generated in a fiber-optic radiation sensor by a charge-coupled device. we have fabricated a fiber-optic radiation sensor which comprises an organic scintillator, a plastic optical fiber and a charge-coupled device. Charge-coupled device as a light measuring tool has many advantages which are easy in multi-dimensional measurements, high spatial resolution and relatively low cost.

단열배관의 온라인 두께측정시스템 개발 (Development of Real Time On-Line Thickness Measuring System for Insulated Pipeline)

  • 장지훈;김병주;조경식;김기동
    • 연구논문집
    • /
    • 통권32호
    • /
    • pp.65-76
    • /
    • 2002
  • The intensity of x-ray or gamma-ray is attenuated according to density and thickness of the transmitted medium. In this study, by using this principle, on-line real-time radiometric system was developed using a 128 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses a Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer. This system collects and analyses the data from the detector array in real-time. The maximum measurable length of pipe is 120cm/mm. in the case of 1mm scanning interval.

  • PDF

CHARACTERISTICS EVALUATION AND GROWTH OF $BI_4GE_3O_{12}$ SINGLE CRYSTAL BY CZOCHRALSKI METHOD

  • Cho, Yun-Ho;Kim, Yong-Kyun;Lee, Woo-Gyo;Kang, Byoung-Hwi;Kim, Jong-Kyung;Lee, Dong-Hoon;Park, Jae-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.83-86
    • /
    • 2009
  • The single crystal scintillator of bismuth germinate ($Bi_4Ge_3O_{12}$:BGO) was successfully grown by the conventional Czochraski technique. The characteristics of the grown BGO were evaluated and presented on the excitation, emission responses and energy spectra of the $\gamma$-rays from $^{241}Am$, $^{133}Ba$, $^{57}Co$, $^{22}Na$, $^{137}Cs$ and $^{54}Mn$ radio-isotopes. The energy resolution of grown BGO, $\Delta$E/E, was estimated to be 12.1% at 662 keV of $\gamma$-ray for $^{137}Cs$ nuclide. Compared to the commercial BGO crystal, we confirmed that the grown BGO has a good performance and is comparable to reference one.

몬테카를로 시뮬레이션을 통한 다층 구조 엑스선 검출기의 특성 평가 (Monte-Carlo Simulation on Properties of X-ray Detector with Multi-layer Structure)

  • 신정욱;박지군;석대우;이채훈;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.427-430
    • /
    • 2003
  • The properties of digital X-ray detectors depend on the absorption extent of X-rays, the generated signal of each X-ray photon and the distribution of the generated signal between pixels. In digital X-ray detector with single layer, signal is generated by X-ray photon captured in photoconductor. In X-ray detector with multi structure that scintillator formed above the top of photoconductor, signal is generated both by X-ray photon captured each in scintillator and photoconductor. X-ray detector with multi structure is generated more signal than single layer detector. In this paper, we simulated absorption fraction of X-ray detector with multi-layer using Monte Carlo program. The results compared with single-layer detector to be formed scinillator or photoconductor.

  • PDF

Development of low-cost, compact, real-time, and wireless radiation monitoring system in underwater environment

  • Kim, Jeong Ho;Park, Ki Hyun;Joo, Koan Sik
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.801-805
    • /
    • 2018
  • In this study, an underwater radiation detector was built using a GAGG(Ce) scintillator and silicon photomultiplier to establish an underwater radiation exposure monitoring system. The GAGG(Ce) scintillator is suitable for small radiation detectors as it strongly absorbs gamma rays and has a high light emission rate with no deliquescent properties. Additionally, the silicon photomultiplier is a light sensor with characteristics such as small size and low applied voltage. Further, a program and mobile app were developed to monitor the radiation coefficient values generated from the detector. According to the results of the evaluation of the characteristics of the underwater radiation monitoring system, when tested for its responsiveness to radiation intensity and reactivity, the system exhibited a coefficient of determination of at least 0.99 with respect to the radiation source distance. Additionally, when tested for its underwater environmental temperature dependence, the monitoring system exhibited an increase in the count rate up to a certain temperature because of the increasing dark current and a decrease in the count rate because of decreasing overvoltage. Extended studies based on the results of this study are expected to greatly contribute to immediate and continuing evaluation of the degree of radioactive contamination in underwater environments.

Development of an energy and efficiency calibration method for stilbene scintillators

  • Kim, Chanho;Kim, Jaehyo;Hong, Wooseong;Yeom, Jung-Yeol;Kim, Geehyun
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3833-3840
    • /
    • 2022
  • A method for calibrating the energy scale and detection efficiency of stilbene scintillators is presented herein. This method can be used to quantitatively analyze the Compton continuum of gamma-ray spectra obtained using such scintillators. First, channel-energy calibration was conducted by fitting a semi-empirical equation for the Compton continuum to the acquired energy spectrum and a new method to evaluate the intrinsic detection efficiency, called intrinsic Compton efficiency, of stilbene scintillators was proposed. The validity of this method was verified by changing experimental conditions such as the number of sources being measured simultaneously and the detector-source distance. According to the energy calibration, the standard error for the estimated Compton edge position was ±1.56 keV. The comparison of the intrinsic Compton efficiencies calculated from the single- and two-source spectra showed that the mean absolute difference and the mean absolute percentage difference are 0.031 %p and 0.557%, respectively, demonstrating reasonable accuracy of this method. The feasibility of the method was confirmed for an energy range of 0.5-1.5 MeV, showing that stilbene scintillators can be used to quantitatively analyze gamma rays in mixed-radiation fields.

몬테카를로 영상모의실험 코드를 이용한 Gd$_2$O$_2$S(Tb) 섬광체 및 광센서 어레이 기반 디지털 X-선 영상시스템의 화질평가 (Evaluation of Image Qualities for a Digital X-ray Imaging System Based on Gd$_2$O$_2$S(Tb) Scintillator and Photosensor Array by Using a Monte Carlo Imaging Simulation Code)

  • 정만희;정인범;박주희;오지은;조효성;한봉수;김신;이봉수;김호경
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권4호
    • /
    • pp.253-259
    • /
    • 2004
  • 본 연구에서는 디지털 X-선 영상시스템의 최적화 설계를 위하여 몬테카를로 방법을 이용한 영상모의실험용 코드를 visual $C^{++}$ 프로그래밍 언어를 사용하여 개발하였다. 디지털 X-선 영상시스템으로 Gd$_2$O$_2$S(Tb) 섬광체 및 광센서 어레이를 고려하였으며, 일반적인 실험 환경을 모사하기 위해 2차원 평행 그리드를 포함시켰다. X-선과 피사체, 그리드 및 섬광체와의 반응, 그리고 섬광체에서 발생된 빛의 거동 및 광센서 어레이에서의 수집을 몬테카를로 방법을 이용하여 모사하였다. Gd$_2$O$_2$S(Tb) 섬광체의 두께는 66$\mu\textrm{m}$로 설정하였으며, 광센서 어레이의 픽셀 피치는 48$\mu\textrm{m}$ 그리고 픽셀의 포맷은 256${\times}$256으로 가정하였다. 다양한 모의실험조건에서 X-선 영상을 획득한 후 객관적인 영상시스템의 성능평가 지표인 SNR(signal-to-noise ratio), MTF(modulation transfer function), NPS(noise power spectrum), DQE(detective quantum efficiency) 등을 계산하였으며, 이를 통해 화질을 평가하였다. 본 연구에서 개발된 영상모의실험 코드는 다양한 디지털 X-선 영상시스템에 대해 여러 설계변수들에 대한 성능을 예측함으로써 영상시스템 최적설계에 활용될 수 있다.

배관류 폐기물의 베타선 오염도 측정용 플라스틱 검출기 제작 및 특성평가 (Fabrication and estimation of the plastic detector for measuring the contamination for beta-ray level of the kind of duct waste)

  • 김계홍;오원진;이근우;서범경
    • 방사성폐기물학회지
    • /
    • 제3권3호
    • /
    • pp.159-165
    • /
    • 2005
  • 원자력 시설의 해체 시 발생되는 다양한 종류의 폐기물 중에서 배관류를 재활용하거나 처분하기 위해서는 배관 내부의 정확한 방사선학적인 오염 특성의 평가가 선행되어야 한다. 그러나 기존의 측정법인 survey-meter를 이용한 오염도의 직접 측정은 배관 내부와 같은 국소지역의 오염 특성을 정확하게 평가할 수 없으며, 간접법을 이용한 표면오염도 측정의 경우도 시료채취의 어려움뿐만 아니라 시료채취 시 작업자의 오염 가능성이 있기 때문에 적용성에 많은 문제점이 있다. 본 연구에서는 Monte Carlo 모사기법을 이용해 직경이 작은 배관 내부의 베타선 오염도를 측정하기 위하여 플라스틱 섬광체를 모사하였으며, 모사 결과에서 베타선 에너지를 효율적으로 측정할 수 있는 최적의 플라스틱 섬광체 두께 및 형상을 도출할 수 있었다. 이 전사모사 결과를 바탕으로 섬광체의 가공 및 배관 내부에서의 검출기 이송 문제를 고려해 검출기를 제작하였으며 그 특성을 평가하였다. 그 결과 배관 내부의 오염도 측정에 적합한 검출기 성능을 확인하였고, 파이프 내부처럼 국소 지역의 방사선학적 오염 특성 평가를 위한 검출기 개발 가능성을 확인하였다.

  • PDF