• Title/Summary/Keyword: Scintillation camera

Search Result 45, Processing Time 0.027 seconds

Spatial resolution and natural image quality assessment evaluation of gamma camera image using pinhole collimator in lutetium-yttrium oxyorthosilicate scintillation detector

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2567-2571
    • /
    • 2023
  • Scintillator materials are widely used in the medical and industrial fields for imaging systems using gamma cameras. In this study, image evaluation is performed by modeling a gamma camera system based on a lutetium-yttrium oxyorthosilicate (LYSO) scintillation detector using a pinhole collimator that can improve the spatial resolution. A LYSO detector-based gamma camera system is modeled using a Monte Carlo simulation tool. The geometric concept of the pinhole collimator is designed using various magnification factors, and the spatial resolution is measured using the acquired source image. To evaluate the resolution, the full width at half maximum (FWHM) and natural image quality assessment (NIQE), a no-reference-based parameter, are used. We confirm that the FWHM and NIQE values decrease simultaneously when the diameter of the pinhole collimator increases. Additionally, we confirm that the spatial resolution improves as the magnification factor increases under the same pinhole diameter condition. Particularly, a 0.57 mm FWHM value is obtained using the modeled gamma camera system with a LYSO scintillation detector. In conclusion, our results demonstrate that a pinhole collimator with a LYSO scintillation detector is a promising gamma camera imaging system.

The Quality Control of Gamma Camera in Nuclear Medicine (핵의학분야(核醫學分野)에서의 Gamma Camera의 품질관리(品質管理)에 관(關)한 연구(硏究))

  • Kim, Jang-Hee;Hong, Seong-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.17 no.1
    • /
    • pp.79-84
    • /
    • 1983
  • 우리나라에 방사성동위원소가 진단 및 치료에 이용된지 20여년이 되였으며 특히 80년대에 들어와서는 Scintillation Camera의 급격한 증가가 이뤄지게 되었다. 그러나 많은 기기의 증가로 품질관리가 필요하게 되었다. 핵의학장비의 품질관리 목적은 장비기능의 정상여부를 조기에 발견하여 항상 균등한 질의 영상을 재현시켜 진단을 보다 정확하게 하는데 있다. 따라서 Scintillation Camera를 사용할 때 사용자는 기계의 기능과 성능을 항상 정확하게 파악하여 적절한 대책을 세워 보다 정확한 영상을 얻을 수 있도록 해야 한다. 저자들은 이러한 점을 고러하여 Scintillation Camera의 품질관리에 대한 원칙과 기술적인 문제점을 문헌고찰과 함께 보고하는 바이다.

  • PDF

Effects of Scintillation Crystal Surface Treatments on Gamma Camera Imaging (섬광체 옆표면처리가 감마카메라 영상에 미치는 효과)

  • Kim, J.H.;Choi, Y.;Oh, C.H.;Kim, J.Y.;Lee, M.Y.;Kim, S.E.;Choe, Y.S.;Joo, K.S.;Kim, B.T.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.303-304
    • /
    • 1998
  • We investigated the effects of scintillation crystal surface treatment on gamma camera imaging. The NaI(Tl) and CsI(Tl) (20 mm (dia.) $\times10mm$ (thick) plate) scintillators were chosen for this study. Two different surface treatments, white and black reflectors, were applied to NaI(Tl) and CsI(Tl). The optical properties of generated scintillation light were evaluated using Monte Carlo simulation and postion sensitive photo multiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of a gamma camera system with the scintillators coupled to a PSPMT. Based on the results, we concluded that the careful consideration of surface treatments of the scintillator was necessary in order to develop the gamma camera having good sensitivity and spatial resolution.

  • PDF

Estimation of Glomerular Filtration Rate Using $^{99m}Tc-DTPA$ and Gamma Scintillation Camera ($^{99m}Tc-DTPA$ 및 Gamma Scintillation Camera를 이용한 사구체 여과율의 측정)

  • Choe, Jae-Gol;Baik, Sei-Hyun;Lee, Min-Jae;Suh, Won-Hyuck
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.95-100
    • /
    • 1992
  • The radioisotopic measurement of glomerular filtration rate (GFR) has required analysis of serial blood or urine samples over several hours, and does not allow measurement of separate renal function unless separate catherterization of individual ureters is done. Gates described isotopic method for the measurement of global and unilateral GFR based on the determination by scintillation camera of the fraction of the injected dose of $^{99m}Tc-diethylenetriaminepentaacetic$ acid (DTPA) present in the kidneys 2-3 minutes after its administration. We calculated GFR according to Gates' method in 58 adult patients with various levels of global renal function using $^{99m}Tc$ DTPA and validated this technique by correlation with 24 hour creatinine clearance. A good correlation was observed between 24 hour creatinine clearance and GFR calculated by Gates' formula, with an r value of 0.91 (p<0.01). We concluded that determination of GFR according to the Gates' formula allows good and reproducible prediction of GFR with great rapidity and simplicity rendering this technique suitable for clinical practice.

  • PDF

Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

  • Kim, Ho Chul;Kim, Hee-Joung;Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.776-780
    • /
    • 2017
  • To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a $^{99m}Tc$ gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

Usefulness of New GAGG Scintillation Detector for Gamma Camera : A Monte Carlo Simulation Study (GAGG 섬광체 물질을 적용한 감마카메라 영상의 유용성 평가: 몬테카를로 시뮬레이션 연구)

  • Kim, Jung-Soo;Park, Chan Rok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.511-515
    • /
    • 2020
  • In this study, we evaluated image quality for new Gadolinium Aluminum Gallium Garnet (GAGG) scintillation material based on the Geant4 Application for Tomographic Emission (GATE) simulation tool. The gamma camera detectors with GAGG and NaI scintillation were designed. In particular, we modeled modified body phantom by National Electrical Manufacturers Association International Electrotechnical Commission to evaluate the simulated images. To analysis the image performance, the contrast to noise ratio (CNR) and coefficient of variation (COV) were used by drawn the region of interests, respectively. Based on the CNR and COV results, the CNR value for GAGG material is higher approximately 17 % than NaI material. In addition, the COV value for GAGG material is lower approximately 17 % than NaI material. In conclusion, we confirmed the performnace of GAGG based gamma camera is useful to improve the image quality for the nuclear medicine instrumentation.