• 제목/요약/키워드: Scintillation Screen

검색결과 11건 처리시간 0.029초

GYAGG/6LiF composite scintillation screen for neutron detection

  • Fedorov, A.;Komendo, I.;Amelina, A.;Gordienko, E.;Gurinovich, V.;Guzov, V.;Dosovitskiy, G.;Kozhemyakin, V.;Kozlov, D.;Lopatik, A.;Mechinsky, V.;Retivov, V.;Smyslova, V.;Zharova, A.;Korzhik, M.
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1024-1029
    • /
    • 2022
  • Composite scintillation screens on a base of Gd1.2Y1.8Ga2.5Al2.5O12:Ce (GYAGG) scintillator have been evaluated for neutron detection. Besides the powdered scintillator, the composite includes 6LiF particles; both are merged with a binder and deposited onto the light-reflecting aluminum substrate. Results obtained demonstrates that screens are suitable for use with a silicon photomultiplier readout to create a prospective solution for a compact and low-cost thermal neutron sensor. Composite GYAGG/6LiF scintillation screen shows a pretty matched sensitivity and γ-background rejection with a widely used ZnS/6LiF screens however, possesses forty times faster response.

고감도 형광판을 이용한 실시간 선량측정 가능성 연구 (Feasibility Study of the Real-Time IMRT Dosimetry Using a Scintillation Screen)

  • 임상욱;이병용;고영은;지영훈;김종훈;안승도;이상욱;신성수;권수일;최은경
    • Radiation Oncology Journal
    • /
    • 제22권1호
    • /
    • pp.64-68
    • /
    • 2004
  • 목적 : 고감도형광판을 이용하여 2차원적인 선량분포를 실시간으로 얻을 수 있는 quality assurance (QA) 장치의 개발 가능성을 알아보고자 한다. 대상 및 방법 : 고감도형광판을 삽입한 직경 25 cm의 물 팬톰을 제작하였으며 여기에 charge-coupled device (CCD) 카메라를 부착하여 방사선조사 시 형광판에서 발생되는 가시광선에 의한 영상을 얻었고 영상이 가지고 있는 세기정보를 계산하여 픽셀값에 따른 선량분포를 실시간으로 확인하였다. 회전치료 및 세기조절방사선치료를 각각 수행하여 형광판으로부터 얻은 등선량곡선을 치료계획장치에서 계산된 등선량곡선과 비교하였다 결과 : 선량당 빛의 세기의 관계그래프를 이용하여 형광판과 CCD의 감도 보정을 위한 커널(kernel)을 구하였는데 두 개의 에러함수 곱으로 표현할 수 있었다. 회전치료(Arc Therapy)와 intensity modulated radiation therapy (IMRT)에서 형광판으로 측정한 등선량곡선과 치료계획장치에서 계산된 등선량분포 비교에서 고선량에서 최대 8 mm 이내의 오차를 보였다. 결론 : 본 연구에서 개발한 2차원 선량계를 이용하여 물팬톰에서 선량과 빛의 세기와의 관계 및 방사선 조사시간과 빛의 양의 관계를 찾을 수가 있었고 세기조절방사선치료 QA를 위한 실시간 평면선량계로서의 사용 가능성을 보였다.

Mechanism analysis of Scintillation in Rear Projection TVs

  • KAGOTANI, Akihito;KAIZUKA, Tomoyoshi;IWATA, Satoshi;SHIMIZU, Yuichiro;MORONAGA, Kohei;TAKAHASHI, Susumu;MASUTOMI, Osamu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1239-1242
    • /
    • 2006
  • Scintillation that is grainy patterns appeared on a screen has been one of a biggest issues in a rear projection TVs. In this paper, with focusing on the average size of random particle, it was proved that the particle size of calculated speckle and the one of measured scintillation are almost the equal. This result shows speckle phenomenon is an important factor of scintillation.

  • PDF

섬광판을 사용하는 조사문영상기구의 기본적인 선량반응성 (Basic Dose Response of Fluorescent Screen-based Portal Imaging Device)

  • 여인환
    • Radiation Oncology Journal
    • /
    • 제17권3호
    • /
    • pp.249-255
    • /
    • 1999
  • 목적 : 본 연구의 목적은 섬광판을 사용하는 전자조사문영상장치의 기본적인 선량반응성을 연구하는 것이다. 대상 및 방법 : 팬텀의 두께와 구성 및 팬텀과 영상장치와의 거리를 변화시킴으로 영상장치에 입사하는 방사선질을 변화시켜가면서 조사면평면에서 신호를 읽었다. 또한 섬광에 의한 신호가 전체신호에 기여하는 상대적인 정도를 모사하였다. 결과 : 본 연구는 조사면평면상에서 선량분포가 팬텀과의 거리 및 팬텀의 두께의 함수임을 보였다. 팬텀의 구성에 따라 조사면영상장치에 의한 선량의 오차는 크게는 $7\%$ 에 달하는 것을 발견했다. 영상장치 내부에서 발생하는 섬광의 산란이 오차의 중요한 원인이 됨을 또한 발견했다. 결론 : 본 연구에서 우리는 조사면영상장치의 선량반응성의 기본적인 특성을 알았다. 또한 섬광판을 기초로 한 영상장치는 정확한 선량측정시스템이 되지 못함을 보았다.

  • PDF

Simulation of a neutron imaging detector prototype based on SiPM array readout

  • Mengjiao Tang;Lianjun Zhang;Bin Tang;Gaokui He;Chang Huang;Jiangbin Zhao;Yang Liu
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3133-3139
    • /
    • 2023
  • Neutron imaging technology as a means of non-destructive detection of materials is complementary to X-ray imaging. Silicon photomultiplier (SiPM), a new type of optical readout device, has overcome some shortcomings of traditional photomultiplier tube (PMT), such as high-power consumption, large volume, high price, uneven gain response, and inability to work in strong magnetic fields. Its application in the field of neutron detection will be an irresistible general trend. In this paper, a thermal neutron imaging detector based on 6LiF/ZnS scintillation screen and SiPM array readout was developed. The design of the detector geometry was optimized by geant4 Monte Carlo simulation software. The optimized detector was evaluated with a step wedge sample. The results show that the detector prototype with a 48 mm × 48 mm sensitive area can achieve about 38% detection efficiency and 0.26 mm position resolution when using a 300 ㎛ thick 6LiF/ZnS scintillation screen and a 2 mm thick Bk7 optical guide coupled with SiPM array, and has good neutron imaging capability. It provides effective data support for developing high-performance imaging detectors applied to the China Spallation Neutron Source (CSNS).

알파선 측정용 ZnS(Ag) 섬광 복합체의 특성에 있어 도포방법이 미치는 영향 (Effect of Coating Technique on the Characteristics of ZnS(Ag) Scintillation Composite for Alpha-ray Detection)

  • 정연희;박소진;서범경;이근우;한명진
    • 공업화학
    • /
    • 제17권6호
    • /
    • pp.604-608
    • /
    • 2006
  • 폴리설폰 기저층에 무기섬광체인 ZnS(Ag)를 도포시켜 방사성 오염도를 측정하는데 사용될 수 있는 고분자 복합체를 제조하였다. 복합체는 방사성 오염물과 반응하여 섬광을 일으키는 무기섬광체의 활성층과 기계적 물성을 소지하여 전체적인 안정성을 부여하며 생성된 섬광의 광자들이 원활하게 투과될 수 있도록 하는 투명층의 폴리설폰 기저층으로 이루어져 있다. 기저층에 섬광체를 포함하는 활성층의 접착은 별도의 접착제 없이 기저 고분자와 동일한 폴리설폰을 바인더로 이용하여 도포시켰으며, 도포 방법으로는 어플리케이터를 이용한 제막방법과 스크린 프린팅을 이용하는 프린팅 기법을 사용하였다. 제조된 복합체는 기저층과 활성층이 일체형을 이루며 서로 완벽하게 접착되었음을 보였다. 제막방법을 통해 이루어진 복합체는 알파선을 탐지에 적합한 검출 특성을 보였으나, 도포 후 형상변형이 일어났으며 스크린 프린팅을 통해 제조된 복합체는 알파오염물에 대한 적절한 탐지특성 및 안정된 형상을 유지하는 것으로 나타났다.

고감도 보급형 방사선 측정센서 모듈 개발 (Development of High-Sensitivity and Entry-Level Radiation Measuring Sensor Module)

  • 오승진;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.510-514
    • /
    • 2022
  • 본 논문에서는 고감도 보급형 방사선 측정센서 모듈 개발을 제안한다. 제안하는 측정센서 모듈은 섬광체+광증배소자(SiPM) 센서 최적화 구조설계, 센서 드라이버용 증폭과 필터 및 제어회로 설계, 근거리 통신을 포함한 제어회로 설계, 센서 기구설계 및 제작, 시제품에 적용되는 GUI 개발 등으로 구성된다. 섬광체+광증배소자(SiPM) 센서 최적화 구조 설계는 센서 구조 설계를 위한 섬광체와 광증배소자(SiPM)의 특성을 확인하여 설계한다. 센서 드라이버용 증폭과 필터 및 제어회로 설계는 SiPM을 이용하여 섬광체로 방사선에 의해 발생하는 미세 섬광신호를 처리하도록 설계한다. 근거리 통신을 포함한 제어회로 설계는 근거리 무선통신 기능을 지원하기 위한 MCU 설계 및 유선 통신 지원을 통해 데이터 전송이 가능하도록 설계를 수행한다. 센서 기구설계 및 제작은 플라스틱 섬광체에서 발생한 미세 섬광 신호를 광증배소자(SiPM)에 전달하기 위해 플라스틱 섬광체 외부에 반사지(미러링)를 감싸 발생한 섬광이 반사되어 효율을 높이도록 설계한다. 시제품에 적용되는 GUI 개발은 각 화면에 따라 상단에 날짜와 시간을 표현하며, 측정단위 및 시간, 초, 알람 레벨, 통신상태, 배터리 용량 등이 표현되도록 한다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 방사선량 측정 범위가 30𝜇Sv/h ~ 10mSv/h로 측정되어서, 현재 국내외에서 상용으로 판매되는 제품들 중에서 최고수준 범위와 같은 결과가 산출되었다. 또한, ±7.4%의 측정 불확도가 측정되어서 국제 표준인 ±15% 이하에서 정상동작 됨이 확인되었다

Gamma Scanning Test에 의한 대단위 차폐체의 결함 평가 연구 (A Evaluation of Shielding Deficiency by Means of Gamma Scanning Test)

  • 이봉재;서경원
    • 비파괴검사학회지
    • /
    • 제14권4호
    • /
    • pp.228-236
    • /
    • 1995
  • 본 연구에서는 비파괴검사 방법의 하나인 gamma scanning test에 의한 대단위 차폐체의 결함을 평가하는 방법을 제시하고 방사선 차폐를 해석하는 유용한 방법중의 하나인 Monte Carlo 코드로 이에 대한 검증을 하였다. Gamma scanning test로 차폐체의 결함을 평가하기 위한 모델은 원통형 차폐체를 대상으로 하였다. 먼저 방사성물질 운반용기에 대한 설계기준에 따라 기준차폐체를 설치하여 Co-60 선원과 섬광계수기로 기준치를 측정하고, 그 다음 실물의 원통형 차폐체를 측정하였다. 기준치로 원통형 차폐체의 납두께를 환산한 결과 결함두께는 최대 12mm로 평가되었다. 이를 검증하기 위한 MCNP 코드의 계산에서는 결함두께가 실험적 결과에 비해 4.1%에 해당하는 최대 11.6mm를 나타내었으며, 두 결과가 만족할 정도로 일치함을 보여주고 있다. 따라서 이러한 평가방법은 방사성물질을 사용하는 시설에 설치되는 대단위 방사선 차폐체나 대용량의 운반용기 차폐능 검사시 현장에서 적용시킬 수 있으며 측정치의 신뢰도를 제고할 수 있다. 앞으로 보다 정확한 측정을 위하여 차폐체의 두께 측정결과가 화면에 직접 표시되는 측정장치의 연구 개발이 요구된다.

  • PDF

Colonic mucin-binding assay를 이용한 장내 우수 점착능 유산균주의 선별 (Screening of Lactic Acid Bacteria with Potent Adhesive Property in Human Colon using Colonic Mucin-binding Assay)

  • 김성영;신광순;이호
    • 한국식품과학회지
    • /
    • 제36권6호
    • /
    • pp.959-967
    • /
    • 2004
  • 인간의 대장내 점막에 대하여 우수한 점착특성을 갖는 probiotic 유산균주를 선별할 목적으로, colonic mucin-binding assay를 고안하고 최적의 분석 조건을 검토한 결과, microtiter plate의 well에 대한 colonic mucin의 부착은 pH 4.8, biotinylated SLP의 농도는 $5.0\;{\mu}g/mL$, 시판 HRP-conjugated streptoavidin은 24,000배 희석용액, TMB의 발색시간은 10분의 조건에서 측정시 최적의 결과를 나타냈다. 동 조건에서 본 assay system을 이용할 경우, 장내 점착능 측정 및 우수 유산균주의 선별에 있어 신속하고 재현성 있는 결과를 제공할 수 있으며, 인간의 대장에 대한 유산균의 점착특성을 정량적으로 분석할 수 있음을 보여주었다. 공시균주 32종 및 유아 분변 유래의 분리균주 18종을 포함한 총 50종의 유산균주에 대하여, colonic mucin-binding assay를 이용하여 대장 mucin에 대한 결합능을 비교한 결과, L. species FSB-1이 가장 높은 결합능을 보여주었다. 따라서 L. species FSB-1을 대상으로 형태학적 특성, 생리 및 생화학적 특성과 16S rDNA에 대한 부분 염기서열 분석을 포함한 동정실험을 수행한 결과, 장내 점착능 우수균주로 선별된 L. species FSB-1은 Lactobacillus brevis로 최종 동정되었다.