• Title/Summary/Keyword: Scintillation

Search Result 453, Processing Time 0.032 seconds

A Study on the Tracking Characteristics of Silicone Rubber Degraded by Accelerated UV Exposure (자외선 가속열화에 의한 실리콘 고무의 트래킹 특성 변화에 관한 연구)

  • Kim, Suk-Cheol;Lee, Jun-Ho;Hwang, Bo-Seung;Lee, Dong-Yeong;Han, Min-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.5
    • /
    • pp.302-309
    • /
    • 2000
  • The tracking characteristics of silicone rubber degraded by accelerated outdoor exposure employing a weather-o-meter were investigated. The tracking test was performed according to ICE Publ.587 method but the concentration of conductive solution was two times higher than IEC standard in order to accelerate the tracking failure. The number of large effective scintillation and the current of high voltage circuit were measured simultaneously. It was shown that the number of effective scintillation had valuable information of the tracking degradation state of silicone rubber, while the average current between electrodes could not provide information enough for diagnosis. Based upon the experimental results, it could be said that the key factor accelerating tracking failure was not Joule heating by current but pyrolysis by burning of silicone rubber, and that reduction of contact angle was due to chain scission which resulted in the free radicals of low molecules.

  • PDF

Detection algorithm of ionospheric delay anomaly based on multi-reference stations for ionospheric scintillation

  • Yoo, Yun-Ja;Cho, Deuk-Jae;Park, Sang-Hyun;Shin, Mi-Young
    • Journal of Navigation and Port Research
    • /
    • v.35 no.9
    • /
    • pp.701-706
    • /
    • 2011
  • Radio waves including GPS signals, various TV communications, and radio broadcasting can be disturbed by a strong solar storm, which may occur due to solar flares and produce an ionospheric delay anomaly in the ionosphere according to the change of total electron content. Electron density irregularities can cause deep signal fading, frequently known as ionospheric scintillation, which can result in the positioning error using GPS signal. This paper proposes a detection algorithm for the ionosphere delay anomaly during a solar storm by using multi-reference stations. Different TEC grid which has irregular electron density was applied above one reference station. Then the ionospheric delay in zenith direction applied different TEC will show comparatively large ionospheric zenith delay due to the electron irregularity. The ionospheric slant delay applied an elevation angle at reference station was analyzed to detect the ionospheric delay anomaly that can result in positioning error. A simulation test was implemented and a proposed detection algorithm using data logged by four reference stations was applied to detect the ionospheric delay anomaly compared to a criterion.

Scintillation properties of BaCl2 crystal (BaCl2 결정의 섬광특성)

  • Doh, Sih-Hong;Kim, Jung-In;Kim, Hong-Joo;Kang, He-Dong;Kim, Sung-Hwan;Oh, Moon-Young
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.217-222
    • /
    • 2008
  • $BaCl_2$ crystals were grown by using the Czochralski method, and their scintillation properties were measured. The emission spectrum was located in the range of $370{\sim}450$ nm, peaking at about 400 nm. The fluorescence decay time was approximately 75.9 ns for 662 keV ${\gamma}$-rays excitation. The energy resolution was about 24.4 % for $^{137}Cs$ 662 keV ${\gamma}$-rays, and the ${\alpha}/{\beta}$ ratio to $\alpha$ particles from a $^{210}Po$ 5.4 MeV was about 0.25.

Estimation of natural radionuclide and exhalation rates of environmental radioactive pollutants from the soil of northern India

  • Devi, Vandana;Chauhan, Rishi Pal
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1289-1296
    • /
    • 2020
  • The estimation of radioactivity level is vital for population health risk assessment and geological point of view and can be evaluated as rate of exhalation and source concentration (226Ra, 232Th and 40K). The present study deals with the soil samples for investigation of radionuclides content and exhalation rates of radon -thoron gas from different sites in northern Haryana, India. Absorbed dose and associated index estimated in the present study are the measures of environmental radioactivity to inhalation dose. Effective doses received by different tissues and organs by considering different occupancy and conditions are also measured. Exhalation rates of radon and thoron are measured with active scintillation monitors based on alpha spectroscopy namely scintillation radon (SRM) and thoron (STM) monitors respectively. Sample height was optimized before measurement of thoron exhalation rate using STM. Average values of radon and thoron exhalation are found 16.6 ± 0.7 mBqkg-1h-1 and 132.1 ± 2.6 mBqm-2s-1 respectively. Also, a simple approach was also adopted, to evaluate the thoron exhalation which accomplished a lot of challenges, the results are compared with the data obtained experimentally. The study is useful in the nationwide mapping of radon and thoron exhalation rates for understanding the environmental radioactivity status.

GAMMA-SPECTROMETRY IN ENVIRONMENTAL MONITORING OF NUCLEAR POWER

  • Cechak, Tomas;Gerndt, Josef;Kluson, Jaroslav;Musilek, Ladislav;Thinova, Lenka
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.203-206
    • /
    • 2001
  • The mathematical processing (unfolding) of pulse height spectra from a scintillation detector helps to calculate the photon fluence rate energy distribution in a measured photon field. The data processing is based on the knowledge of detection system response function and directional dependence respectively. The experimental results of the photon fields measurements in the vicinity of the spent fuel temporary storage and inside the storage hall are presented. The containers Castor 440 are used for temporary storing of the burnt up fuel assemblies in the Czech nuclear power plant Dukovany. A set of periodical measurements was performed in order to get basic information on the time dependence of the photon fields spatial distributions and spectral characteristics in the temporary storage hall and its vicinity. The photon fields were measured by the scintillation system. The obtained photon fields spatial distributions and spectral characteristics present the information on the radiation hazard in the storage.

  • PDF

Line Image Correction of the Positron Camera in the Secondary Beam Course of HIMAC

  • Iseki, Yasushi;Mizuno, Hideyuki;Kanai, Tatsuaki;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Suda, Mitsuru;Tomitani, Takehiro;Urakabe, Eriko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.195-198
    • /
    • 2002
  • A positron camera, consisting of a pair of Anger-type scintillation detectors, has been developed for verifying the ranges of irradiation beams in heavy-ion radiotherapy. Images obtained by a centroid calculation of photomultiplier outputs exhibit a distortion near the edge of the crystal plane in an Anger-type scintillation detector. The images of a $\^$68/Ge line source were detected and look-up tables were prepared for the position correction parameters. Asymmetry of the position distribution detected by the positron camera was prevented with this correction. As a result, a linear position response and a position resolution of 8.6 mm were obtained over a wide measurement field.

  • PDF

Properties and Peculiar Features of Application of Isoelectronically Doped $A^2B^6$ Compound-Based Scintillators

  • Ryzhikov, V.;Starzhinskiy, N.
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.77-84
    • /
    • 2005
  • The authors submit the data concerning the methods of obtaining semiconductor scintillators on the basis of the zinc chalcogenide crystal doped with impurities (Te, Cd, O, $Me^{III}-metals$ Al, In, etc.). Characteristics of such crystals and mechanisms for the semiconductor scintillator luminescence are described as well. The scintillator luminescence spectra maximums are located within the range 450-640nm, which depends on the method of preparing the scintillator. The luminescence decay time ranges within $0.5-10{\mu}s\;and\;30-150{\mu}s$. The afterglow level is less than 0.01% after $10-20{\mu}s$, and the radiation stability is ${\geq}5{\cdot}10^8$ rad. Thermostability of the output characteristics of new semiconductor scintillators on the basis of zinc selenide is prescribed by thermodynamic stability of the principal associative radiative recombination centers that come into existence due to the crystal lattice inherent imperfections. Certain application fields of the new scintillators are examined taking into account their particular qualities.

The study of Na Doping rate for application CsI:Na in the amorphous selenium (비정질 셀레늄 기반에서 CsI:Na 응용을 위한 Na의 조성비 연구)

  • Cha, Byung-Youl;Park, Ji-Koon;Kang, Sang-Sik;Lee, Kyu-Hong;Nam, Sang-Hee;Choi, Heung-Kook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.412-414
    • /
    • 2003
  • This paper is about research of scintillator layer, which is used for Hybrid method to increase electric signals in a-Se, the material of Direct method. In case of the thermal evaporation, CsI has column structure which is an disadvantage as scintillator. But it decreases scattering of incident X-ray, has better Light output intensity than other scintillation materials. CsI was made by Thermal evaporation. The Doping material, Na, 0.1, 0.3, 0.5, 0.7g were added in each sample. Analysis of absorbed wavelength, PL(Photoluminescence), Light output intensity, SEM, and XRD analysis were performed to analyze optical characteristics. Doping rate of CsI:Na to use as scintillation layer in a-Se based detector could be optimized.

  • PDF